• Title/Summary/Keyword: ground freezing

Search Result 154, Processing Time 0.029 seconds

Evaluation of durability of an ECC(Engineered Cementitious Composite) designed with ground granulated blast furnace slag (고로슬래그 미분말이 혼입된 ECC(Engineered Cementitious Composite)의 내구성 평가)

  • Kim, Jeong-Su;Kim, Yun-Yong;Kim, Jin-Keun;Ha, Gee-Joo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.329-332
    • /
    • 2006
  • This paper presents the experimental results for durability of an ECC designed with ground granulated blast furnace slag (BFS) through the test method of chloride ion resistance and freezing-thawing resistance. In order to compare with ECC, normal mortar was also tested. Test results showed that BFS ECC exhibited higher durability performance than ordinary mortar. These results suggest that by adding BFS in ECC, its matrix density is increased which results in decreased of deterioration and it also adds to the fiber bridging that contributes in control of cracking.

  • PDF

Analysis of Penetration Depths in Pavement in Korea (포장도로에서의 동결심도 조사분석)

  • Kim, Young-Chin;Hong, Seung-Seo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.475-482
    • /
    • 2005
  • Many public facilities including roadway, railway, and embedded pipe lines in this country have been damaged by the repeated freezing and thawing of the soil during winter and spring every year. However, there are only few research results in field of frozen ground in this country. Also, there are no the formulation of the reasonable equation for frost penetration depths and of the criterion for identifing potentially frost-susceptible soil in design manual of pavement yet. Through this study it is anticipated to asses the frost action problem in roadway, railway, and water suppply lines and to establish the design criterion about pavement in seasonal cold region.

  • PDF

The Optimum Temperature of Brine Heating System for LNG Storage Tank (LNG 저장탱크용 Brine Heating System의 최적온도 설정)

  • Oh, B.T.;Hong, S.H.;Yang, Y.M.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.361-366
    • /
    • 2001
  • The purpose of installation of the brine heating system for LNG storage tank is the prevention of ground freezing. If the ground of LNG tank areas is frozen, it is caused by safety problems. The design of brine heating system for LNG storage tank which is constructing in our country is not well considered about domestic weather conditions and economical efficiency. Therefore, this paper reports on the study of the optimized temperature of inside pipes and cooling process through the transient analysis by using the existing brine heating system.

  • PDF

A Study on the Minimization of Ground Resistance Variance by Temperature and Freezing of Ground (온도변화 및 토양동결에 의한 접지저항값 변화 최소화에 관한 연구)

  • Kim, Geun-Hwan;Wong, Yoon-Chan;Park, Jung-Shin
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.73-73
    • /
    • 2006
  • 본 연구의 목적은 배전선로 접지극의 온도변화 및 토양동결 상태에 따른 접지저항값의 변화를 관찰하고, 영상과 영하의 온도와 접지저항값 변화의 상관관계를 분석하여 접지저항값 변화를 최소화하는 데 있다. 온도변화에 따른 접지저항값 변화의 최소화를 이루기 위하여 접지극과 토양의 접촉저항을 최소화하는 방안을 연구 하였으며, 이를 현장에 적용하여 검증한 결과, 접지저항값의 변화가 최소화되는 우수한 성과를 거양하여 각종 접지공사의 설계시 활용할 수 있도록 하였다.

  • PDF

A Study on the Depth of Frost Penetration in Korea (우리나라의 동결심도(凍結深度)에 관한 연구(研究))

  • Hong, Won Pyo;Kim, Myung Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.147-154
    • /
    • 1988
  • Korea has the ground which freezes in winter and melts in warmer seasons by turns. Therefore, in designing civil-structures or buildings on such ground, the depth of seasonal frost penetratio must be considered. In this paper, approximate contours of the maximum depth of frost penetration in Korea is presented. It was found that the maximum depth of frost penetration did not have the linear relationship to square root of the freezing index. In order to establish more reliable method to estimate the maximum depth of frost penetration, a new empirical equation is introduced. In the presented equation, the dry unit weight and water content of soil are considered in addition to the freezing index. And the equation is compared with other previous equations used so far.

  • PDF

Physical and Mechanical Characteristics of the Antarctic Rocks Exposed to the Extreme Environment (극한환경에 노출된 남극 암석의 물리적·역학적 특성)

  • Kim, Kiju;Kim, YoungSeok;Hong, Seung Seo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6C
    • /
    • pp.275-284
    • /
    • 2012
  • The Antarctic continent exposed to strong wind, very low temperature, and extremely dry condition. The freezing-thawing cycles under this extreme environment change the mechanical characteristics of rocks near the ground surface. To investigate the effect of freezing-thawing cycles under the extreme environment understand on geotechnical properties of rocks, rocks from the Antarctica were collected from two places: (1) West Antarctic Cape Burks and (2) East Antarctic Terra Nova Bay areas. The rock characteristics of these two areas were described and compared. For Terra Nova Bay area, rock characteristics of rocks near the surface and depths exceeding 2.9 m were examined. The 'near-the-surface rocks' averages of absorption rate, P-wave velocity, and unconfined compressive strength were 0.56%, 3,717 m/s, and 109MPa, respectively; while, those values of 'deep-sited rocks' were 0.24%, 4,670 m/s, and 88MPa. From the measurements, it was found that the effects of weathering were not significant on mechanical characteristics (strength) but were pronounced on physical characteristics(absorption and P-wave velocity).

The Effect of Rapid Freeze Pretreatment on Grinding of Organic Ion Exchange Resins (금속동결 전처리에 의한 유기이온 교환수지의 분쇄효과)

  • Yim, Sung-Pal;Kim, Joun-Hyeong;Son, Jong-Sik
    • Applied Chemistry for Engineering
    • /
    • v.1 no.1
    • /
    • pp.23-29
    • /
    • 1990
  • The effect of a rapid freeze pretreatment of organic ion exchange resins on their grinding properties was studied. It was found that the structure of ion exchange resins was defected by freezing pressure formed in the process of rapid freezing. The defected resins didn't recover their own structure after thawing and those could be easy to be broken at room temperature by small force. Therefore, organic ion exchange resins could be ground readily at room temperature after rapid-freezing the fully swelled resins using by solid carbon dioxide, or liquid nitrogen. The rapid freeze pretreatment of cation exchange resins was very effective on grinding in particular. However, the effect of the pretreatment of anion exchange resins on grinding was less than that of cation exchange resins. In case of anion exchange resins, the ionic form of affected the grindability remarkably.

  • PDF

Analysis of the Relationship between Unconfined Compression Strength and Shear Strength of Frozen Soils (동결토의 일축압축강도와 전단강도 상관관계 분석에 관한 연구)

  • Kang, Jae-Mo;Lee, Jang-Guen;Lee, Joonyong;Kim, YoungSeok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.3
    • /
    • pp.23-29
    • /
    • 2013
  • The mechanical behavior of frozen soils is different from that of unfrozen soils due to the phase change between water and ice. The strength characteristics of frozen soils are governed by the intrinsic material properties such as grain size, ice and water content, air bubbles, and by externally imposed testing conditions such as temperature, freezing time, and strain rate. Especially, the strength of the frozen soils is generally higher than that of unfrozen soils due to ice binding capacity with soil particles, and is strongly affected by a highly complex interaction between the solid soil skeleton and the pore matrix, composed of ice and unfrozen water. In this study, the direct shear test and unconfined compression test are carried out inside of a large-scaled freezing chamber, and the relationships between cohesion and unconfined compression strength under various freezing temperature conditions are discussed.

Design of Replacement Method on Anti-freeze Process of L Type Retaining Wells (L형 옹벽의 동상대책에 있어서 치환공법의 설계)

  • Rui, Da-Hu;Kim, Young-Su;Suzuki, Teruyuki
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.9
    • /
    • pp.19-27
    • /
    • 2009
  • In order to investigate anti-freeze process of precast concrete L-type retaining walls in cold regions, test walls were installed in the campus of Kitami Institute of Technology (KIT, Hokkaido, Japan). The wall consists of following three sections, i) back filled with frost susceptible clay soil, ii) using thermal insulation material, and back filled with frost susceptible soil, iii) back filled with frost-unsusceptible soil. The freezing front distribution and ground temperature within the backfill were observed and deflections of the walls were measured over three freeze-thaw seasons. Some understanding of the mechanisms of the build-up of frost heave pressure was gained, and the effectiveness of replacement method was observed. A simulation was performed to predict the shape of the freezing front in the backfill behind L-type walls with various cross sections. These findings were employed to propose a method for determining the appropriate zone to be replaced with frost unsusceptible backfill material in cold regions.

The Evaluation of Surface Scaling and Resistance of Concrete to Frost Deterioration with Freezing-Thawing Action by Salt Water (염화물이 함유된 동결수의 동결융해 작용에 따른 콘크리트의 내동해성과 표면열화 평가)

  • Kim, Gyu-Yong;Kim, Moo-Han;Cho, Bong-Suk;Lee, Seung-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.143-151
    • /
    • 2007
  • This study presents the experimental results of frost durability including resistance to freezing-thawing and surface scaling of concrete. Mixing design was proportioned with the various water-binder ratio between 0.37 and 0.47 and three different binder compositions corresponding to Type I cement without any supplementary cementitious materials(OPC), Type II cement with 50% blast-furnace slag replacement(BFS50), and ternary cement with Type III cement, 15% fly ash, and 35% slag replacement (BFS35%+FA15%). Test results showed that the mixing design with BFS50% and BFS35%+FA15% exhibited higher durability factor than that made with OPC only. Finally, the use of blend cement containing slag can be used effectively in terms of frost durability of the concrete exposed to severe condition under coastal environment like as flying salt, sea water spray, etc.