• Title/Summary/Keyword: grip force

Search Result 110, Processing Time 0.022 seconds

Presence evaluation of virtual refrigerator doors in opening and closing (가상환경에서의 냉장고 도어 개폐의 현실감 평가)

  • 박재희;이인석;김진욱;고희동
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2003.05a
    • /
    • pp.90-93
    • /
    • 2003
  • This study aims to validate the effectiveness of VE system with an arm-master in the evaluation of virtual prototype. A virtual kitchen with a refrigerator was presented in a CAVE system. Subjects put in and pull out virtual objects by using the arm-master. Twelve subjects participated in six experimental conditions: three types of refrigerator door grips and two reaction forces. After each trial, subjects evaluated a virtual refrigerator in terms of easiness of operation, similarity in force, presence etc. The results show the subjects preferred vertical grip than horizontal grip and light reaction force than heavy one. The VE system with the arm-master will be very helpful in the design evaluation of virtual prototypes.

  • PDF

Development of Intelligent Gripper Control Device to Safely Grip Unknown Objects (미지물체를 안전하게 잡기 위한 지능형 그리퍼의 제어장치 개발)

  • Kim, Han-Sol;Kim, Gab-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.4
    • /
    • pp.31-38
    • /
    • 2022
  • In this study, we designed and manufactured an intelligent gripper-control device to safely grip unknown objects. The gripper control device consists of a DSP circuit, power supply circuit, communication circuit, and amplifier circuit diagrams. The DSP is used because the values of the 3-axis force sensor to which the gripper is attached are measured and calculated at high speeds. The gripping force is determined based on this value, and the object must be safely gripped with the determined value. A basic characteristic test of the control device of the manufactured intelligent gripper was conducted, and it was confirmed that it operated safely.

Effects of the Abdominal Drawing-in Maneuver and the Abdominal Expansion Maneuver on Grip Strength, Balance and Pulmonary Function in Stroke Patients

  • Yoon, Mi-Ra;Choi, Ho-Suk;Shin, Won-Seob
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.147-153
    • /
    • 2015
  • Purpose: The purpose was to determine whether the application of the abdominal drawing-in maneuver (ADIM) and abdominal expansion maneuver (AEM) to stroke patients would affects their trunk stability, balance, pulmonary function, and grip strength. Methods: The subjects were 36 stroke patients who were randomly and equally assigned to an ADIM group (n=12), an AEM group (n=12), and a control group (n=12). The intervention was applied to each group three times per week, 30 minutes each time, for four weeks. Outcome measures were grip strength, modified functional reach test (mFRT) and pulmonary function. Pulmonary function were measured force expiratory volume at one second (FEV1), forced vital capacity (FVC), FEV1/FVC and peak expiratory flow (PEF) values. Results: The results of the three groups showed statistically significant improvements in grip strength. The AEM group showed significantly greater differences in grip strength than either the ADIM group or the control group. In the anterior mFRT, the ADIM group showed significantly improvements than the control group. The ADIM and AEM groups were showed statistically significant greater improvements in PEF between the baseline and post-intervention and the post-analysis revealed that the AEM group showed significantly greater improvements than the control group. Conclusion: The results of this study indicate that the ADIM and AEM were effective in improving the PEF of pulmonary function. The ADIM was more effective than AEM in trunk stabilization.

EEG Analysis Following Change in Hand Grip Force Level for BCI Based Robot Arm Force Control (BCI 기반 로봇 손 제어를 위한 악력 변화에 따른 EEG 분석)

  • Kim, Dong-Eun;Lee, Tae-Ju;Park, Seung-Min;Ko, Kwang-Eun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.2
    • /
    • pp.172-177
    • /
    • 2013
  • With Brain Computer Interface (BCI) system, a person with disabled limb could use this direct brain signal like electroencephalography (EEG) to control a device such as the artifact arm. The precise force control for the artifact arm is necessary for this artificial limb system. To understand the relationship between control EEG signal and the gripping force of hands, We proposed a study by measuring EEG changes of three grades (25%, 50%, 75%) of hand grip MVC (Maximal Voluntary Contract). The acquired EEG signal was filtered to obtain power of three wave bands (alpha, beta, gamma) by using fast fourier transformation (FFT) and computed power spectrum. Then the power spectrum of three bands (alpha, beta and gamma) of three classes (MVC 25%, 50%, 75%) was classified by using PCA (Principal Component Analysis) and LDA (Linear Discriminant Analysis). The result showed that the power spectrum of EEG is increased at MVC 75% more than MVC 25%, and the correct classification rate was 52.03% for left hand and 77.7% for right hand.

A Systematic Review on the Association between Cognitive Function and Upper Extremity Function in the Elderly (노인의 인지기능과 상지기능의 관련성에 관한 체계적 고찰)

  • Moon, Mi-Sook;Jung, Min-Ye
    • Therapeutic Science for Rehabilitation
    • /
    • v.5 no.2
    • /
    • pp.23-33
    • /
    • 2016
  • Objectives: The aim of this study was to investigate the association between cognitive function and upper extremity function in the elderly. The articles were analyzed based on patient, intervention, comparison, and outcome using the P.I.C.O. principle. Methods: We systematically examined papers from January, 2000 to November, 2015 published papers through the foreign journals which were Medline & Pubmed for three months. mainly used key words were elderly, dementia, Alzheimer's disease, Mild cognitive impairment, age-related, aging, cognitive, upper extremity function, hand function, hand-grip strength, grip force, complex motor function, bimanual, dexterity, UE performance, and coordination. Results: The number of discovered outcomes for association between cognitive function and upper extremity function in the elderly was 7; grip strength & sex are impact on manipulation object, 1. The results show that cognitive function is associated with upper extremity function in the elderly. Conclusion: This study is expected to help selecting intervention, assessment tools according to the individual's degree of cognitive level and upper extremity function. In future domestic research, variety assessment tools need to be used and more qualitative level experiment will be carried out.

Evaluation of control feel in opening and closing the doors of a virtual refrigerator in the CAVE system with an Arm-Master (CAVE 공간에서 Arm-Master를 이용한 가상냉장고 도어 개폐의 조작감 평가)

  • 박재희;이인석;김진욱;고희동
    • Science of Emotion and Sensibility
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • This study aims to validate the effectiveness of CAVE system with an Arm-Master in the evaluation of virtual prototypes. A virtual kitchen with a refrigerator was presented in the CAVE system. Subjects put in and pull out virtual objects by using the Arm-Master. Twelve subjects, six males and six females, participated in the six experimental conditions : three types of refrigerator door grips and two reaction forces. After each trial, subjects evaluated a door grip of the virtual refrigerator in terms of easiness of operation, similarity in force, presence etc. The results show the mean values of vortical-type door grips are greater than the horizontal pocket-type door grip. Also the subjects preferred 5N in the reaction force of the Arm-Master rather than 15 N when they open and close virtual door. Unexpectedly, female subjects significantly marked low scores in the evaluation terms compared ruth mali subjects. It explains the Arm-Master should be modified much more if it works effectively in design evaluation.

  • PDF

Anxiolytic-Like Effects of Cyclopeptide Fraction Alkaloids of Zizyphi Spinosi Semen: Possible Involvement of GABAA Receptors

  • Han, Huishan;Ma, Yuan;Eun, Jae-Soon;Hong, Jin-Tae;Oh, Ki-Wan
    • Biomolecules & Therapeutics
    • /
    • v.16 no.3
    • /
    • pp.261-269
    • /
    • 2008
  • This experiment was performed to investigate the anxiolytic-like effects of cyclopeptide fraction alkaloids of Zizyphi Spinosi Semen (CFAZ), by using the experimental paradigms of anxiety, and compared with those of a known anxiolytic, diazepam. CFAZ (8.0 mg/kg, p.o.) increased the percentage of time spent on the open arms and the number of open arms entries in the elevated plus-maze test, increased the number of head dips in the hole-board test, and increased the percentage of center zone ambulatory time in the open-field box. However, CFAZ has no effect on the locomotor activity, while diazepam (2.0 mg/kg, p.o.) significantly reduced locomotor activity. CFAZ did not influence the grip force in the grip strength meter test, either. From the molecular experiments, CFAZ increased chloride influx in cultured cerebellar granule cells. In addition, $GABA_A$ receptors $\gamma$-subunit were over-expressed by CFAZ in cultured cerebellar granule cells. It is concluded that CFAZ may have anxiolytic-like effects, and these effects may be mediated by $GABA_A$ receptors.

SW05 Rotor Lift of an Unmanned Helicopter for Precise ULV Aerial Application (초미량 정밀살포용 무인헬리콥터의 SW05 로터 양력시험)

  • Koo, Young-Mo;Seok, Tae-Su;Shin, Shi-Kyoon
    • Journal of Biosystems Engineering
    • /
    • v.35 no.1
    • /
    • pp.31-36
    • /
    • 2010
  • A small unmanned helicopter was suggested to replace the conventional spray system. Aerial application using an agricultural helicopter helps precise and timely spraying, and reduces labor intensity and environmental pollution. In this research, a rotor system (SW05) was developed and its lift capability was evaluated. Lift force for the dead weight of the helicopter was obtained at the grip pitch angle of $12^{\circ}$. As the pitch angle increased to $14^{\circ}$ and $16^{\circ}$, the payload increased to 176 N and 216 N, respectively. Compared with SW04 airfoil performance in the total lift, the SW05 airfoil showed nearly the same capacity, but the payload of the SW05 was reduced because of the increased dead weight. A rated flight condition was defined as lifting mean payload of 294 N with the grip pitch angles of $16{\sim}17^{\circ}$ at the rotor rotating speed of 850~950 rpm for the adjusted engine power. The fuel consumption would be 4.8~6.0 L/hr, and the air temperature of cooling fan should be kept below $160^{\circ}C$.

Evaluation of Glove Designs Applying Change in Hand Length Dimensions by Hand Motion (손동작에 따른 손체표 길이 변화를 적용한 장갑 설계 평가)

  • Kwon, O-Chae;Sun, Mee-Sun;Jung, Ki-Hyo;Lee, Min-Jeong;Yeon, Soo-Min;You, Hee-Cheon;Kim, Hee-Eun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.15-21
    • /
    • 2005
  • Use of a glove made of materials with a low elasticity decreases the performance of the hand such as agility, dexterity, range of motion, and grip strength. The present study examined if the adverse effects of a low-elastic glove can be reduced by a design which accommodates the changes of hand surface lengths by hand motion. Two glove designs which provide patches of elastic cloth and pleats at the finger joints and knuckle were developed by considering the hand surface length changes, and then compared with two conditions(bare hand and conventional glove design that does not consider the dynamic characteristics of the hand dimensions) in terms of completion time in peg board insertion task, maximum grip strength, discomfort in hand motion, discomfort in force exertion, and overall discomfort by 24 right-handed participants. The test results confirmed that wearing of a glove significantly reduced the agility and grip strength capability of the hand and indicated that the novel designs were effective to lessen the performance decreases compared to the conventional design. Also, of the glove designs, the pleat glove design was found most preferred for both better hand performance and less subjective discomfort.