• 제목/요약/키워드: grid filter

검색결과 360건 처리시간 0.021초

계통연계형 인버터의 LCL필터 최적 설계기법 (Optimized LCL filter Design Method of Utility Interactive Inverter)

  • 정상혁;최세완
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.103-109
    • /
    • 2013
  • The conventional LCL filter design method of the utility interactive inverter considers only harmonics attenuation of the current injected to the grid. However, in case of utility-interactive inverter with critical load the voltage quality of the critical load should also be considered for LCL filter design. Also, considering cost and volume of LCL filters. it is important to have minimum values of inductance and capacitance as far as the harmonic standards are satisfied. In this paper a LCL filter design method is proposed to satisfy not only the harmonic standards of the grid current during the grid-connected mode but the voltage quality of the critical load during grid-connected mode and stand-alone mode. With the proposed method optimized values of LCL filters could be obtained by applying weighting factor to voltage ripple across the critical load, inductor volume, amount of reactive current and system bandwidth.

순시전력이론을 통한 계통연계 PWM 인버터 시스템의 능동댐핑 기법 (An active damping method of a grid-connected PWM Inverter using an instantaneous power theory)

  • 정해광;이교범;강신일;이현영;권오정;송승호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.85-87
    • /
    • 2008
  • The demand of a three phase PWM inverter for the purpose of power control or grid-connecting is increasing. This inverter is connected to a grid through an L-filter or LCL-filter to reduce the harmonics caused by switching. An LCL-filter can reduce the harmonic of a low switching frequency and generate a satisfactory level of grid side current with a relatively low-inductance than an L-filter. But the additional poles caused by the LC part affects a stability problem due to induced resonance of the system. This paper presents a compensation method using a power theory to improve performance, the designed LCL-filter system and to reduce the stability problems caused by resonance. The effectiveness of the proposed algorithm is verified by simulations.

  • PDF

An Improved Multi-Tuned Filter for High Power Photovoltaic Grid-Connected Converters Based on Digital Control

  • Sun, Guangyu;Li, Yongli;Jin, Wei
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.160-170
    • /
    • 2018
  • For high power photovoltaic (PV) grid-connected converters, high order filters such as multi-tuned filters and Traps+RC filters with outstanding filtering performance have been widely researched. In this paper, the optimization of a multi-tuned filter with a low damping resistance and research on its corresponding control scheme have been combined to improve the performance of the proposed filter. Based on the characteristics of the switching harmonics produced by PWM, the proposed filter is optimized to further improve its filtering performance. When compared with the more common Traps+RC filter, the advantages of the proposed filter with low damping resistances in attenuating the major switching harmonics have been demonstrated. In addition, a simpler topology and reduced power loss can be achieved. On the other hand, to make the implementation of the proposed filter possible, on the base of the unique frequency response characteristic of the proposed filter, a digital single-loop control scheme has been proposed. This scheme is a simple and effective means to suppress the resonance peak caused by a lack of damping. Therefore, a smaller volume, better efficiency of the proposed filter, and easy implementation of the corresponding control scheme can be realized. Finally, the superiority of the proposed filter topology and control scheme is verified in experiments.

Design Methodology of Passive Damped LCL Filter Using Current Controller for Grid-Connected Three-Phase Voltage-Source Inverters

  • Lee, Jun-Young;Cho, Young-Pyo;Kim, Ho-Sung;Jung, Jee-Hoon
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1178-1189
    • /
    • 2018
  • In grid-connected voltage-source inverters (VSIs), when compared with a simple inductive L filter, the LCL filter has a better performance in attenuating the high frequency harmonics caused by the pulse-width modulation of power switches. However, the resonance peaks generated by the filter inductors and capacitors can make a system unstable. In terms of simplicity and filter design cost, a passive damping method is generally preferred. However, its high power loss and degradation in high frequency harmonic attenuation are significant demerits. In this paper, a mathematical design solution for a passive LCL filter to derive filter parameters suppressing the high frequency current harmonics to 0.3% is proposed. The minimum filter inductance can be obtained to reduce the size of the filter. Furthermore, a minimum damping resistance design considering a current controller is analyzed for a stable closed-loop system. The proposed design method is verified by experimental results using a 5-kW three-phase prototype inverter.

스마트그리드 IED용 대역통과여파기 소형화를 위한 메타재질구조 설계법 연구 (Study on the Metamaterial Design Methodology to Reduce the Size of the Bandpass Filter for the Smart Grid IED)

  • 강승택;김형석
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2299-2304
    • /
    • 2011
  • In this paper, we propose the methodology to make the bandpass filters for the Smart Grid IED(Intelligent Electronic Device) smaller than the conventional bandpass filters. The size-reduction of the filters and the filter performances are indebted to devising small CRLH(composite right- and left-handed) resonators and coupling them as the metamaterial structures. The design methodology is validated by the equivalent circuit to be compared with the reliable full-wave EM simulation, and the proposed metamaterial filter outperforms the standard parallel-edge coupled filter with respect to the miniaturization and frequency response.

A Capacitance Estimation of Film Capacitors in an LCL-Filter of Grid-Connected PWM Converters

  • Heo, Hong-Jun;Im, Won-Sang;Kim, Jang-Sik;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.94-103
    • /
    • 2013
  • A capacitor deterioration of LCL-filter grid-connected PWM converters is progressed by the self-healing mechanism. It leads to the degradation of the filter performance and drop of power factor. Thus, it is required to diagnose fault-point of capacitors and determine the replacement time. Typically, the fault of capacitors is determined when the capacitance is reduced up to 80% from initial value. This paper proposes algorithm to the determine capacitor replacement time of an LCL filter. The algorithm takes the advantage of change of the response on the injected resonant frequency corresponding to 80% value from the initial capacitance. The results of the algorithm are demonstrated through simulations and experiments.

A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters

  • Geng, Yiwen;Qi, Yawen;Zheng, Pengfei;Guo, Fei;Gao, Xiang
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1555-1566
    • /
    • 2018
  • Proportional capacitor-current-feedback active damping (AD) is a common damping method for the resonance of LCL-type grid-connected inverters. Proportional capacitor-current-feedback AD behaves as a virtual resistor in parallel with the capacitor. However, the existence of delay in the actual control system causes impedance in the virtual resistor. Impedance is manifested as negative resistance when the resonance frequency exceeds one-sixth of the sampling frequency ($f_s/6$). As a result, the damping effect disappears. To extend the system damping region, this study proposes a virtual resistor-inductor-capacitor (RLC) AD method. The method is implemented by feeding the filter capacitor current passing through a band-pass filter, which functions as a virtual RLC in parallel with the filter capacitor to achieve positive resistance in a wide resonance frequency range. A combination of Nyquist theory and system close-loop pole-zero diagrams is used for damping parameter design to obtain optimal damping parameters. An experiment is performed with a 10 kW grid-connected inverter. The effectiveness of the proposed AD method and the system's robustness against grid impedance variation are demonstrated.

DFT를 이용한 계통연계 인버터 시스템의 고정밀 계측 (High Precise Measurement of Grid-Connected Inverter using DFT)

  • 이상혁;강필순;이상훈;조수억;이태원;박성준
    • 전력전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.93-98
    • /
    • 2012
  • A precise measurement of the grid voltage is one of the essential techniques, which is required to connect a renewable energy to the grid. In general, when a filter is used to eliminate unnecessary harmonics and noises, a signal is distorted by phase delay, amplitude attenuation, and other distortions. And the response characteristic of a controller is directly affected by bandwidth of cut-off frequency of the filter. To alleviate this problems, we propose an effective algorithm based on DFT(Discrete Fourier Transform) instead of approaching the filter application. The proposed algorithm ensures high precise measurement of the grid voltage because it can extract the fundamental and harmonics from the raw signal without any distortions. The high performance of the proposed algorithm is verified by PSIM simulation and experiments of Grid-Connected VSI.

다중 배열 니들 코팅을 이용한 LED 스크린용 Anti-Moiré 필터 제작 (Fabrication of Anti-Moiré Filter Using Multi-Array Needle Coating for LED Screens)

  • 전경준;이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제20권1호
    • /
    • pp.77-82
    • /
    • 2021
  • Using a multi-array needle module developed for coating of high-density cylindrical microlens array (C-MLA), we have fabricated an anti-Moiré filter for LED screens. The Moiré phenomenon appears due to the interference between the array pattern of image sensors in a camera and the non-emission area (grid pattern) of a LED screen. To suppress it, we have employed poly(methyl methacrylate) (PMMA) and coated it on a glass substrate in the form of a grid and non-grid (parallel lines). We have rotated the needle module in order to increase the number of C-MLAs. With this scheme, we have fabricated the 150 mm × 150 mm anti-Moiré filters where 836 microlens lines are formed. They show the average width of 255.4 ㎛, the average distance between CMLs of 94.6 ㎛, and C-MLA width non-uniformity of 4.7%. We have shown that the Moiré patterns still appear in the presence of the parallel (non-grid)-type filter, whereas they disappeared completely by the grid-type filter. It is due to the fact that the Moiré patterns are diffused more effectively by the grid-type C-MLA.

DC Injection Control for Grid-Connected Single-Phase Inverters Based on Virtual Capacitor

  • Wang, Wei;Wang, Ping;Bei, Taizhou;Cai, Mengmeng
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1338-1347
    • /
    • 2015
  • DC injection is a critical issue in transformerless grid-connected inverters. DC injection control based on virtual capacitor has the advantages of low cost, low loss, high accuracy and easy implementation. In this paper, the principle of DC injection control based on virtual capacitor was analyzed. In addition, the applicable conditions, working process, steady state error and advantages were also discussed in detail. The design of the control parameters based on virtual capacitor was proposed in a grid-connected inverter with LCL filter. The robustness of the control parameters was also discussed. Simulation and experimental results verify the validity of the analysis and demonstrate that this research has a certain value in engineering applications.