• 제목/요약/키워드: grid connected PWM inverter

검색결과 76건 처리시간 0.019초

PWM 방식에 따른 계통연계 양방향 인버터의 손실양상 비교 및 분석 (Loss Analysis and Comparison of Grid-connected Bidirectional Inverter with Different Types of PWM Schemes)

  • 허성준;안효민;변종은;이병국
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.547-550
    • /
    • 2017
  • This paper presents a loss analysis and compares three pulse width modulation (PWM) methods applied in a three-phase grid-connected bidirectional inverter for an energy storage system. The losses in switching devices and output low pass filters are theoretically analyzed by using PWM control techniques. Grid-connected bidirectional inverters are designed by using PWM techniques, and the designed inverters are simulated to verify the analysis results.

DPWM 방식을 적용한 3상 계통 연계 인버터의 LCL-필터 설계 (Design of LCL-filter for Grid-Connected Three-Phase Inverters Using a Discontinuous PWM Method)

  • 이정록;서승규;이교범
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.419-427
    • /
    • 2016
  • This paper proposes a design method of LCL-filter for a grid-connected three-phase inverter using a discontinuous PWM (DPWM) method. When using a DPWM method, many harmonic voltages are generated in the inverter output compared to a continuous PWM (CPWM) method. Therefore, an optimized grid-connected filter design is required for a DPWM method. The proposed design method provides generalized formula to design accurate LCL-filter without trial and error procedures. An inverter side inductance is designed by analyzing the current ripple injected to the grid. The Optimized parameters of LCL-filter can be designed by analyzing the total harmonic distortion (THD) and the ripple attenuation factor of the output current. The proposed LCL filter design method is demonstrated by simulation and experimental results.

계통 연계를 위한 병렬 LCL 여파기용 Interleaved PWM 인버터 (Interleaved PWM Inverter with Paralleled LCL Filter for Grid Connection)

  • 김현동;전성즙
    • 전력전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.275-282
    • /
    • 2022
  • In this study, an inverter system connected to a grid through a paralleled LCL filter is proposed. The system consists of two inverters paralleled and operated with interleaved PWM for powering up and performance improvement. Two LCL filters have two separate filter inductors and one set of filter capacitor and grid inductor in common. The differential mode current circulates through two inverters and two filter inductors. The differential mode current is removed from the filter capacitor and the power grid. Accordingly, performance improvement can be achieved due to the reduced currents in the filter capacitor and the reduced harmonics into a grid. A single-phase prototype has been made and tested, and the proposal has been verified.

공통 모드 전압 및 THD를 고려한 계통연계형 3레벨 NPC 인버터의 운용 알고리즘 연구 (A Study on Operation Algorithm of Grid-Connected 3-Level NPC Inverter Considering Common-Mode Voltage and THD)

  • 김혜천;박정욱
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.1-7
    • /
    • 2023
  • A grid-connected 3-level NPC inverter is a power conversion device that connects renewable energy generators, such as photovoltaic or wind turbines to the grid. Although many studies have focused on this inverter, commercializing it requires strictly satisfying various safety and power quality-related standards. Among many standards, leakage current and grid current total harmonic distortion(THD) can be affected by external factors such as installation environment, aging, and grid conditions. Hence, inverter operations that can satisfy these standards need to be explored. In this study a 3-level NPC inverter operation algorithm using the Phase Opposition Disposition-PWM method that can effectively reduce leakage current and switching frequency adjustment to reduce THD effectively has been proposed.

Voltage Distortion Approach for Output Filter Design for Off-Grid and Grid-Connected PWM Inverters

  • Husev, Oleksandr;Chub, Andrii;Romero-Cadaval, Enrique;Roncero-Clemente, Carlos;Vinnikov, Dmitri
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.278-287
    • /
    • 2015
  • This paper proposes a novel voltage distortion approach for output filter design based on the voltage transfer function for both off-grid and grid-connected Pulse Width Modulation (PWM) Inverters. The method explained in detail is compared to conventional methods. A comparative analysis is performed on an example of L and LCL-filter design. Simulation and experimental results for the off-grid and the grid-connected single phase inverter prove our theoretical predictions. It was found that conventional methods define redundant values of the output filter elements. Assumptions and limitations of the proposed approach are also discussed.

순시전력이론을 통한 계통연계 PWM 인버터 시스템의 능동댐핑 기법 (An active damping method of a grid-connected PWM Inverter using an instantaneous power theory)

  • 정해광;이교범;강신일;이현영;권오정;송승호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.85-87
    • /
    • 2008
  • The demand of a three phase PWM inverter for the purpose of power control or grid-connecting is increasing. This inverter is connected to a grid through an L-filter or LCL-filter to reduce the harmonics caused by switching. An LCL-filter can reduce the harmonic of a low switching frequency and generate a satisfactory level of grid side current with a relatively low-inductance than an L-filter. But the additional poles caused by the LC part affects a stability problem due to induced resonance of the system. This paper presents a compensation method using a power theory to improve performance, the designed LCL-filter system and to reduce the stability problems caused by resonance. The effectiveness of the proposed algorithm is verified by simulations.

  • PDF

분산 발전 시스템에서 계통연계 인버터의 매끄러운 모드 전환 (Grid Connected Inverter of ESS for Seamless mode Transition)

  • 홍창표;김학원;조관열
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.364-372
    • /
    • 2016
  • In this paper, a voltage controller for the seamless transition of a grid-connected inverter for ESS is proposed. The single-phase inverter is operated as a current controller when the grid is connected and as a voltage controller in the stand-alone mode when the grid is disconnected. Generally, in the case of grid recovery, the overcurrent may flow into the system because of the mismatch phase between the inverter output and grid voltages. The proposed controller resolves the overcurrent problem through phase delay problems with initial value feed-forward control of the integrator when the grid voltage is restored. The effects of the control method are simulated through PSIM, and the usefulness of the control method is verified through experiments.

A Modified Single-Phase Transformerless Z-Source Photovoltaic Grid-Connected Inverter

  • Liu, Hongpeng;Liu, Guihua;Ran, Yan;Wang, Gaolin;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1217-1226
    • /
    • 2015
  • In a grid-connected photovoltaic (PV) system, the traditional Z-source inverter uses a low frequency transformer to ensure galvanic isolation between the grid and the PV system. In order to combine the advantages of both Z-source inverters and transformerless PV inverters, this paper presents a modified single-phase transformerless Z-source PV grid-connected inverter and a corresponding PWM strategy to eliminate the ground leakage current. By utilizing two reversed-biased diodes, the path for the leakage current is blocked during the shoot-through state. Meanwhile, by turning off an additional switch, the PV array is decoupled from the grid during the freewheeling state. In this paper, the operation principle, PWM strategy and common-mode (CM) characteristic of the modified transformerless Z-source inverter are illustrated. Furthermore, the influence of the junction capacitances of the power switches is analyzed in detail. The total losses of the main electrical components are evaluated and compared. Finally, a theoretical analysis is presented and corroborated by experimental results from a 1-kW laboratory prototype.

단상 계통연계 인버터의 SRF 전력제어 방법 (A SRF Power Flow Control Method for Grid-Connected Single-Phase Inverter Systems)

  • 박한얼;김은석;송중호
    • 조명전기설비학회논문지
    • /
    • 제24권5호
    • /
    • pp.129-135
    • /
    • 2010
  • 화석에너지의 고갈과 환경오염 문제를 해결하기 위한 대안인 신재생 에너지를 이용하는 분산발전 시스템은 핵심 구성 요소인 PWM 인버터의 전력제어가 요구된다. 본 논문에서는 단상 계통연계 인버터 시스템의 전력제어를 위해 계통 임피던스를 고려한 SRF(synchronous-reference-frame) 전력제어 방법을 제안한다. 제안한 SRF 전력제어 방법은 복잡한 계통 임피던스의 추정 없이 계통 임피던스의 공칭값(nominal value)에 기반해 단상 인버터에 전압 기준값(reference)을 제공하여 독립운전 모드와 계통연계 모드에서 모두 운전이 가능함을 나타내었다. 또한, 유효전력과 무효전력의 독립적인 제어가 가능한 장점을 가진다. 계통을 포함하는 시뮬레이션을 통해 제안한 SRF 전력제어 방법의 타당성을 검증한다. 시뮬레이션 결과는 제안한 SRF 전력제어 방법을 통해 단상 계통연계 인버터 시스템의 전력 흐름을 적절히 제어할 수 있음을 보여주고 있다.

계통연계형 단상인버터의 Common Mode Noise 저감을 위한 Switching 방법 (A Switching Method of Single Phase Grid Connected Inverter for Common Mode Noise Reduction)

  • 이승주;홍창표;김학원;조관열
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.27-33
    • /
    • 2016
  • A pulse-width modulation (PWM) method for common mode noise reduction in a PWM inverter connected to a single-phase grid is proposed in this study. The extensively used conventional switching method may experience common mode voltage problems, which generate current leakage and electromagnetic induction problems. In the proposed switching method, the neutral point of the output voltage is always fixed at both ends of the input voltage to reduce common mode noise. The validity of the proposed method is proven through simulation and experimental results.