• Title/Summary/Keyword: grade-band

Search Result 79, Processing Time 0.028 seconds

A Comparative Analysis of Production Process between Manufacturers and References of Clothing Construct in Universities - Focused on Skirts and Slacks- (대학의 의복구성 교육 교재 내용과 업계 생산공정의 차이에 관한 비교연구 - 스커트와 슬랙스를 중심으로 -)

  • 박상희
    • Journal of the Korean Home Economics Association
    • /
    • v.41 no.5
    • /
    • pp.179-191
    • /
    • 2003
  • The study is to suggest easier making method of skirts and slacks as to compare production process between manufacturers and references of clothing construct in universities. Skirts and slacks have simple production process and they are basic subjects in clothing construct class. But most references have just contents which are to make basic styles of skirts and slacks made basic materials. Continuous development of new material and variety of style request more efficient and easer making method in the reference of clothing construct. So the making methods of references and manufacturers are compared and analyzed in this study In references, there are many hand work and sub-work because they are for a person who make own clothes. In contrast, manufacturers have to product many variety clothes of good quality for many people and think the production cost of clothes. They use more simple and efficient method that include their know-how to meet changing fashion situation. In making methods of skirts and slacks, differences between references and manufacturer are in sewing of waist band and zippers and location of interlining. Manufacturers use variedly sewing method of waist band according to material and their experience. Especially handling for wrong side inseam of waist band is distinct between references and manufacturers. References have basic and detail work and manufacturers know processing order having even grade work to keep continuous production. The making method of clothes have to change and improve according to the situation. The more useful making method get to include their merits and references need to add more practical method and knowledge.

Compact Broad Band-pass Filter with SIR-Parallel Coupled Structure (SIR 평행결합 선로를 갖는 소형 광대역 대역통과 필터)

  • Hong, Tae-Ui;Lee, Jeong-Hun;Yoon, Ki-Cheol
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.11
    • /
    • pp.84-90
    • /
    • 2010
  • In this paper, the reduced size of broad bandpass filter with parallel coupled line structure is presented. This proposed filter can control bandwidth of narrow to broadband by adjusting the coupling coefficient. The conventional filter is operated with a narrow band. If a higher bandwidth is desired than the conventional narrow bandwidth, it is hard to realize due to the coupling coefficient between feeding line and resonator. In this paper, to overcome this limitation, a proposed bandpass filter is designed with reduced size due to SIR(Stepped Impedance Resonator) and multi-grade type structures than conventional one, and it has characteristics of adjusting bandwidth freely as per quantity of coupling coefficient. The proposed bandpass filter that, experimental results of insertion and return losses are 0.42 dB and 20.9 dB with bandwidth of 60 % at the center frequency of 5.8 GHz, respectively.

Optimization and Performance Evaluation for the Science Detector Systems of IGRINS

  • Jeong, Ueejeong;Chun, Moo-Young;Oh, Jae-Sok;Park, Chan;Yu, Young Sam;Oh, Heeyoung;Yuk, In-Soo;Kim, Kang-Min;Ko, Kyeong Yeon;Pavel, Michael;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.91.1-91.1
    • /
    • 2014
  • IGRINS (the Immersion GRating INfrared Spectrometer) is a high resolution wide-band infrared spectrograph developed by the Korea Astronomy and Space Science Institute (KASI) and the University of Texas at Austin (UT). This spectrograph has H-band and K-band science cameras, both of which use Teledyne's $2.5{\mu}m$ cutoff $2k{\times}2k$ HgCdTe HAWAII-2RG CMOS science grade detectors. Teledyne's cryogenic SIDECAR ASIC boards and JADE2 USB interface cards were installed to control these detectors. We performed lab experiments and test observations to optimize and evaluate the detector systems of science cameras. In this presentation, we describe a process to optimize bias voltages and way to reduce pattern noise with reference pixel subtraction schemes. We also present measurements of the following properties under optimized settings of bias voltages at cryogenic temperature (70K): read noise, Fowler noise, dark current, and reference-level stability, full well depth, linearity and conversion gain.

  • PDF

MR Imaging Findings of Cortical Dysplasia of the Brain: Correlation with Pathologic Grades and Subtypes (뇌피질 이형성증의 자기공명영상소견: 병리적 등급 및 유형과의 연관성에 대하여)

  • Bae Ju Kwon;Kee-Hyun Chang;Chun-Kee Chung;Moon Hee Han;Yoon La Choi;Je G. Chi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.47-55
    • /
    • 2003
  • Purpose : Cortical dysplasia is known to be of variety of MR imaging findings. We attempted to classify MR imaging findings of cortical dysplasia into several types and to correlate those with histopathologic grades and subtypes. Materials and Methods : Preoperative MR images of 97 patients with pathologically-proven cortical dysplasia were retrospectively reviewed with knowledge of the diagnosis and operative sites. The patients were divided into MR-positive and MR-negative groups based on the presence or absence of MR imaging abnormalities. In MR-positive group, MR imaging features were arbitrarily classified into four types (atrophic, cortical-band, inward-rounding, and nonspecific types) on the basis of size of the gyrus and adjacent CSF space, cortical thickness, signal intensity of the subcortical white matter, and blurring of the gray-white matter junction. The pathologic findings were also retrospectively reviewed without knowledge of MR imaging findings and divided into three grades (mild, moderate, and severe) and two subtypes (nonballoon-cell and balloon-cell). Pathologic grades and subtypes we re compared between MR-positive and MR-negative groups. Four MR types of the MR-positive group were correlated with the pathologic grades and subtypes. Results : MR-positive and MR-negative groups consisted of 39 (40%) and 58 (60%) patients, respectively. Of the MR-positive group, atrophic type was seen in 13 patients (33 %), cortical-band type in 9 (23%), inward-rounding type in 9 (23%), and nonspecific type in 8 (21%). There was no significant difference in the pathologic grades between MR-positive and MR-negative groups, although MR-positive group tended to have higher pathologic grades than MR-negative group did. Balloon-cell subtype was found significantly higher in MR-positive group than in MR-negative group (p<0 .05): 21% (8/39) versus 5% (3/58). The inward-rounding type corresponded to the pathologically severe grade and balloon-cell subtype in 78% (7/9) and 56% (5/9) of the patients, respectively, while the atrophic type to the mild grade and nonballoon-cell subtype in 77% (10/13) and 100% (13/13), respectively. Conclusion : A variety of MR imaging abnormalities were found in 40% of the patients with cortical dysplasia and those were classified into four types (atrophic, cortical-band, inward-rounding, and nonspecific types), of which the inward-rounding type correlated well with the pathologically severe grade and balloon-cell subtype, whereas the atrophic type with the mild grade and nonballoon-cell subtype.

  • PDF

A Comparative Analysis on the Current Housing Unit Plans of Korea and China (${\cdot}$중 현대 집합주거 단위평면 비교연구)

  • Jung Byung-Moon;Kim Hyeon-Ji;Lee Sang-Hong
    • Journal of the Korean housing association
    • /
    • v.16 no.6
    • /
    • pp.65-72
    • /
    • 2005
  • The purpose of this study is to get preeminent data from comparative analysis of multi-family housing unit plans between Korea and China nowadays. Even though Korea and China belong to common cultured band in Asia, there are many different Housing aspects and unit plans. Through this study we want to grasp the characteristics of both nation's apartment unit plans and to contribute for advance into the China apartment market. Analysis target is constructing and lotting out apartment at South Korea and China in 2004, and the space syntax model is used as an analysis tool. First, analyze kind, number and special quality of each room by use area, and second, analyze area and scale of the rooms. Through the integration analysis we know the grade of rank and centrality of each rooms, and search difference of South Korean and Chinese apartment.

Relationship between Oxidation and Wear of Ultra-High Molecular Weight Polyethylene for Total Joint Arthroplasty

  • Lee, Kwon-Yong
    • KSTLE International Journal
    • /
    • v.2 no.1
    • /
    • pp.55-58
    • /
    • 2001
  • The most widely-used orthopaedic grade polymer bearing liner material, ultrahigh molecular weight polyethylene (UHMWPE), for the total joint arthroplasty degrades after gamma-irradiation sterilization through the progressive oxidation in a shelf and in vivo. Oxidative degradation makes UHMWPE brittle and leads to decrease in mechanical properties. In this study the relationship between post-gamma-irradiation aging time and wear of UHMWPE was investigated. Six retrieved polyethylene hip liners implanted for 3-16 years and then stored in air for 1.5-6.5 years until tests were used. Two types of pin-on-disk wear testing were conducted by the uni-directional repeat pass rotating and by the linear reciprocating stainless steel disks against stationary polyethylene pins under 4Mpa at 1Hz with bovine serum lubrication in ambient environment. Wear of retrieved polyethylene hip liners does not have direct correlation with in vivo or total aging time. Linear reciprocal sliding motion generated more remarkable wear than uni-directional repeat pass sliding motion. It indicates that kinematic motion affects very crucially on the wear of aged UHMWPE having brittle white band region.

  • PDF

A Study on the historical research of the leading man's Costume in 'Chun hyangjeon' ('춘향전(春香傳)'에 등장(登場)하는 주요(主要) 남자(男子) 복식(服飾) 고증(考證) 연구(硏究))

  • Kim, Moon-Ja
    • Journal of Fashion Business
    • /
    • v.9 no.4
    • /
    • pp.79-93
    • /
    • 2005
  • 'Chunhyangjeon' was written by an anonymous author in the mid-period of Chosun Dynasty. The personalities of characters and the styles of dress of men in 'Chunhyangjeon' recreated their clothing to one that is more similar to the descriptions in the literature text can be described as follows. Lee, Mongyong was a young man, but he was a man of integrity and honor. In outwear he wore 'Hat(Heulip)' and 'Dopo' and Taesahae. When he earned his title, he wore 'Pokdu' with flowers and 'Angsam(ceremonial robe)'. After he became a secret royal inspector, in order to disguised on himself as a poor man he wore worn-out 'Heuklip' and 'Dopo' and Jipsin. Bangja who was a servant of Lee, Mongyong wore 'Beonggeoji' and 'Kwaeja' and 'Mituli'. Byun, Hacdo was a rash and greedy character, he wore 'Oklolip' and 'Cheopli' and 'mokhwa' when he was on the way to his post. Yeokjol was low grade official wore 'Jeonlip' and 'Cheopli' and 'Red shoulder band' and 'Mituli'.

The Development of HFPD System for Mibile-loading Vehicles (차량탑재형 HFPD의 개발)

  • Kim, Deok-Geun;Im, Jang-Seop;Yeo, In-Seon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.33-37
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

Extrusion of CP Grade Titanium Powders Eliminating the need for Hot Pre-compaction via Hot Isostatic Pressing

  • Wilson, Robert;Stone, Nigel;Gibson, Mark
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1273-1274
    • /
    • 2006
  • Chemically pure, hydride/dehydride titanium powders were cold pre-compacted then extruded at $850^{\circ}C$ and $\sim450MPa$ under argon. The extrusions were 100% dense with a narrow band of surface porosity and equiaxed microstructure of similar magnitude to the starting material. The tensile properties of the bars were better than conventionally extruded CP titanium bar product. Outcomes from this study have assisted in the identification of a number of key characteristics important to the extrusion of titanium from pre-compacted CP titanium powders, allowing the elimination of canning and hot isostatic pressing (HIPping) of billets prior to extrusion as per conventional PM processes.

  • PDF

A Study on the Thermal Conductivity and Floor Impact Sound of Polyurethane Concrete (폴리우레탄 콘크리트의 열전도율과 바닥충격음에 관한 연구)

  • 강재홍;조영국;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.676-681
    • /
    • 1997
  • The purpose of this study is to evaluate the thermal Conductivity and Foolr Impact Sound of Polyurethane Concretes. The Polyurethane Concretes are prepared with various resin content, Fine and Coarse aggregates content, and its thickness, and tested for the Thermal Conductivity and Impact Sound. From the test results. the sound insulation grade of polyurethane concretes by the floor impact sound test on high frequency band is L-60, and its effect is considerable Polyurethane concretes have high degree of solidity compared with other heat shield materials, and its thermal conductivity is 0.05kcal/$mh^{\cire}C$. And it is suitable for sound proof floor materials.

  • PDF