• 제목/요약/키워드: goniometer

검색결과 252건 처리시간 0.022초

엄지발가락휨각도 측정을 위한 각도계의 신뢰도와 타당도 (Reliability and Validity of the Goniometer for Hallux Valgus Angle Measurement)

  • 정성대;강선영;김문환;원종혁
    • 한국전문물리치료학회지
    • /
    • 제20권2호
    • /
    • pp.46-51
    • /
    • 2013
  • The purpose of this study was to investigate the reliability and validity of goniometer measurements of the hallux valgus angle (HVA) compared to radiographic measurements, which are the current standard. Twenty subjects (10 female, 10 male) were recruited for this study (40 feet). The HVA of the subjects was measured using goniometer and radiographic measurement. In three trials, measurements were taken of each subject by two examiners using goniometer and radiographic measurements using radiography in a standing position. The reliability of the measurements was investigated using intraclass correlation coefficients (ICC(3,1)), and the validity was tested using the Pearson product-moment correlation coefficient and an independent t-test. The intra-rater reliability of left and right HVAs were poor (ICC=.409 and .341, respectively). The inter-rater reliability of left and right HVAs were poor and moderate (ICC=.303 and .501, respectively). Left and right HVAs measured using goniometer and radiographic measurements were also poor and moderate (Pearson r=.246 and .544, respectively). These results suggest that goniometer measurements of the HVA are inaccurate and have unacceptable validity compared to radiographic measurements.

고관절 내외회전 가동범위 검사에 대한 범용플라스틱 측각기의 동시타당도와 임상적 유용성 (Concurrent Validity and Clinical Usefulness of Universal Plastic Goniometer for Hip Internal and External Rotation Range Measurement)

  • 김용욱
    • 대한물리의학회지
    • /
    • 제13권1호
    • /
    • pp.99-105
    • /
    • 2018
  • PURPOSE: The aim of this study was to evaluate the concurrent validity and clinical usefulness of the universal plastic goniometer to measure the range of motion of the internal and external rotation of the hip joint using the three dimensional motion analysis which can analyze the joints and segment movements in the most objective and quantitative method. METHODS: Clinical and kinematic data were collected from thirty individuals using a universal plastic goniometer and a ten camera motion analysis system. Passive hip rotation range was obtained three trials for left and right hip joints using two measure methods simultaneously. RESULTS: There were significant differences between all matching measures of the two measures of internal and external rotation of the hip joint (p<.05). The relationship between the two tests for all measurements of the internal and external rotation of the hip was statistically significant with correlation coefficient form r=.87 to .96. (p<.01). CONCLUSION: Clinical measurement of the internal and external rotation of the hip using a universal plastic goniometer is effective to assess the hip condition. However, application of universal plastic goniometer requires careful attention in more accurate evaluation and research verification of the internal and external rotation of hip joint.

뇌졸중 환자의 수동적 어깨 관절 가동범위 측정에 관한 스마트폰과 측각기의 측정자내, 측정자간 신뢰도 연구 (Intra- and Inter-Rater Reliability of Measuring Passive Range of Shoulder Motion With Smartphone and Goniometer in Patients With Stroke)

  • 박일우;임원빈;박규남;이충휘
    • 한국전문물리치료학회지
    • /
    • 제21권1호
    • /
    • pp.1-12
    • /
    • 2014
  • The purpose of this study were to determine the intra-rater and inter-rater reliability of shoulder passive range of motion measurement using the "Clinometer + bubble level", a smartphone application and to compare with the intra-rater and inter-rater reliability of measurement using a goniometer. Twenty six patients with stroke were recruited for this study. Two raters measured the passive range of motion of four types of shoulder movements (forward flexion; FF, abduction; ABD, external rotation at $90^{\circ}$ abduction; ER90 and internal rotation at $90^{\circ}$ abduction; IR90) using a goniometer and a smartphone to determine within-day inter-rater reliability. A retest session was performed thirty minutes later to determine within-day intra-rater reliability. The reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). The ICC (2,1) for the inter-rater reliabilities of the goniometer and smartphone were good in FF and ABD [ICC (2,1)=.75~.87] and excellent in ER90 [ICC (2,1)=.90~.95]. The intra-rater reliabilities for the goniometer and smartphone were good or more than good, with an ICC (3,1) value >.75, the exception was IR90 measured by rater 2 on the smartphone. These results suggest that smartphone could be used as an alternative method tool for measurement of passive shoulder range of motion in patients with stroke.

A Study on the Validity and Test-Retest Reliability of the Measurement of the Craniovertebral Angle of the Smart Phone Application 'Angles Video Goniometer'

  • Hyeon-Seong Joo;Byeong-Soo Kim;Myung-Mo Lee
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권4호
    • /
    • pp.454-463
    • /
    • 2022
  • Objective: The purpose of this study was to compare concurrent validity and test-retest reliability based on Craniovertebral angle of 'Angles video goniometer', a smart phone application for convenient range of motion measurement, and 'Image J', an analysis software with high reliability and validity. This was conducted to find out whether 'Angle video goniometer' can be used clinically. Design: Cross-sectional study Methods: Fifty subjects were imaged laterally, and the angle of the head and spine was measured using Image J and the Angles video goniometer, respectively, in a resting posture and a chin in posture. The level of concurrent validity between the two measurement methods and the level of inter-rater reliability and intra-rater reliability were analyzed. Results: For forty participants, the concurrent validity between Image J and Angles video goniometer showed very high validity with ICC of 0.997(0.995~0.999) and 0.994(0.994~0.998), CVME% 0.71~0.72%, SEM% 0.31~0.34, MDC% 0.86~0.94. The test-retest intra-rater reliability showed very high reliability ICC 0.994(0.991~0.996), CVME% 0.71%, SEM% 0.31~0.43, MDC% 0.86~1.19%. The test-retest inter-rater showed very high reliability ICC 0.995(0.992~0.997), CVME% 0.71%, SEM% 0.43~0.59%, MDC% 1.20~1.62% Conclusions: Angles video goniometer', a smartphone application, is a device with very high reliability and validity for craniovertebral angle measurement in healthy adults, and it is a device that can be easily used in clinical practice.

보행장애 진단을 위한 무릎관절 각도 측정용 광섬유 각도센서 (Fiber-optic Goniometer to Measure Knee Joint Angle for the Diagnosis of Gait Disturbance)

  • 김선근;신상훈;전다영;홍승한;심혁인;장경원;유욱재;이봉수
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.1009-1013
    • /
    • 2013
  • In this study, we developed a fiber-optic goniometer for the continuous measurement of knee joint angle which provides important medical information on Alzheimer's disease. The fiber-optic goniometer is composed of a light-emitting diode (LED), a plastic optical fiber (POF), and a voltage output photodiode (PD). As a sensing part of the fiber-optic goniometer, a unclad fiber with regular intervals of 1 mm was fabricated to improve efficiency of bending loss according to the angle variation of knee joint. The emitting light with a center wavelength of 470 nm from a LED is guided by a POF to the PD, the transmitted light is then attenuated by the bending loss inside the bent POF. The intensity variation of the light transmitted from the POF gives rise to a change in output voltage in the fiber-optic goniometer. Therefore, we measured the real-time output voltage of the proposed fiber-optic goniometer using the unclad fiber according to the knee joint angle. Through the repeated experiments, the fiber-optic goniometer shows that it has a reversibility and a wide measurable angle range.

주관절 가동범위 측정법에 대한 동시타당도와 신뢰도 (Concurrent Validity, Inter-Tester and Intra-Tester Reliability of Goniometric Measurement of Active Elbow Range of Motion Using 4 Different Types of Measuring Instruments)

  • 구애련;이충휘
    • 한국전문물리치료학회지
    • /
    • 제2권2호
    • /
    • pp.46-55
    • /
    • 1995
  • The purpose of this study was to assess the concurrent validity and reliability of goniometric measurement of joint motion. Subjects were 40 healthy university students. Measurements were performed by 4 inexperienced physical therapy students. Four different instruments were used and three readings were taken with each instrument in random order making a total of 12 readings for flexion of the right elbow of each subject. Goniometers used were 1. universal 2. fluid-based goniometer/inclinometer 3. digital LCD goniometer 4. electronic goniometer/torsiometer. The results were as follows: Concurrent validity was highest (r= .94) with the universal and digital LCD tools. Interrater reliability (Pearson Product Moment Correlation) was good for each tool. Interrater reliability calculated by ICC(2,1) was highest (.96) with the tensiometer and lowest (.78) with the digital LCD goniometer. Intrarater reliability calculated by ICC was excellent (${\geq}.90$) for all instruments. These results show that concurrent validity, intrarater and interrater reliability are very good in the used of all four types of goniometers/inclinometer/tensiometer, even with inexperienced raters. These results confirm the almost universal reliance on hand held goniometers for joint measurement by physical therapists as being a reliable practice. Further research should be done clinically with actual patients.

  • PDF

스마트폰 경사계를 사용한 엉덩관절 가동범위의 측정 신뢰도 연구 (Reliability Study of Hip Range of Motion Measurement by Smartphone Inclinometer)

  • 양회송;정찬주;유영대;배세현
    • 대한통합의학회지
    • /
    • 제4권2호
    • /
    • pp.89-96
    • /
    • 2016
  • Purpose : The purpose of this study was to evaluate inter-tester reliability and Intra-tester reliability about range of motion(ROM) measurement of hip joint with smartphone inclinometer. Method : Six observers performed goniometric and smartphone inclinometer measurements of various hip movements, including both active ROM for flexion, extension, external rotation, internal rotation. Measurements were performed in the right hip of fifty normal subjects. All measures were performed three times for evaluating reliability of observer. Inter- and intra-observer reliabilities were evaluated using the intraclass correlation coefficient(ICC). Result : The results were as follows, inter-observer reliability ICC value showed .948-.974 in smartphone inclinometer. And showed .781-.827 in goniometer. Intra-observer reliability ICC value showed .653-.992 in smartphone inclinometer. And showed .613-.854 in goniometer. Conclusion : Smartphone inclinometer are portable and widely available tools that are mostly reliable and valid for assessing active hip range of motion, with potential use when a goniometer is not available.

A Study on the Reliability and Validity of Measuring the Range of Motion of the Elbow Joint Using a Smartphone Application

  • Lee, Jun Cheol
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권3호
    • /
    • pp.65-72
    • /
    • 2018
  • The purpose of this study was to assess the intra-tester and inter-tester reliability and validity of elbow flexion range of motion using a smart phone used by the general public. Thirty-one general people participated in this study. The range of motion in active elbow flexion was measured with a goniometer and smart phone over two times by two observers. The intra-taster and inter-tester reliability were evaluated using the intraclass correlation coefficient(ICC). The validity was measured by Pearson's correlation coefficient. The intra-observer reliability was good in all measured items ICC>0.900. The inter-observer reliability was high with ICC>0.806. All correlation coefficients of android app and goniometer were greater than 0.868 and showed a significant positive correlation (p<0.01). The range of motion measurement with a smart phone showed acceptable reliability. Therefore, using a smartphone to measure the range of motion of the elbow joint could provide convenience and economic benefits.

Reliability and Validity of Measurement Using Smartphone-Based Goniometer of Tibial External Rotation Angle in Standing Knee Flexion

  • Jeon, In-Cheol;Kwon, Oh-Yun;Weon, Jong-Hyuck;Ha, Sung-Min;Kim, Si-Hyun
    • 한국전문물리치료학회지
    • /
    • 제20권2호
    • /
    • pp.60-68
    • /
    • 2013
  • The purpose of this study was to assess the intra-rater test-retest reliability of tibial external rotation angle measurement using a smartphone-based photographic goniometer, DrGoniometer (DrG) compared to a three-dimensional motion analysis system (Vicon). The current study showed an interchangeable method using DrG to measure the tibial external rotation angle in standing knee flexion at $90^{\circ}$. Twelve healthy subjects participated in this study. A rest session was conducted 30 minutes later for within-day reliability and five days later for between-day intra-rater test-retest reliability. To assess the validity of the measurement using DrG, we used a three dimensional motion analysis system as a gold standard to measure the angle of tibial external rotation. Intra-class correlation coefficient (ICC) and the standard error of measurement (SEM) values were used to determine the within- and between- day intra-rater test-retest reliability of using DrG and a three dimensional motion analysis system. To assess validity, Pearson correlation coefficients were used for two measurement techniques. The measurement for tibial external rotation had high intra-rater test-retest reliability of within-day (ICC=.88) and between-day (ICC=.83) reliability using DrG and of within-day (ICC=.93) and between-day (ICC=.77) reliability using a three-dimentional motion analysis system. Tibial external rotation angle measurement using DrG was highly correlated with those of the three-dimensional motion analysis system (r=.86). These results represented that the tibial external rotation angle measurement using DrG showed acceptable reliability and validity compared with the use of three-dimensional motion analysis system.