• 제목/요약/키워드: gold film

검색결과 277건 처리시간 0.027초

상악동의 점막비후에 대한 WATERS방사선사진과 파노라마방사선사진 및 전산화단층사진의 진단능 비교 (Comparison of Waters′ radiography, panoramic radiography, and computed tomography in the diagnosis of antral mucosal thickening)

  • 현영민;이삼선;최순철
    • 치과방사선
    • /
    • 제28권1호
    • /
    • pp.261-269
    • /
    • 1998
  • With the CT findings as gold standard, the sensitivity, the specificity, and the diagnostic accuracy of Waters' radiography and Waters' radiography with panoramic radiography were compared in the diagnosis of antral mucosal thickening of 16 patients. Three oral radiologists and three non-oral radiologists interpreted the Waters' radiographs and after 4 weeks, interpreted the Waters' radiographs and panoramic radiographs simultaneously. The interpretation point was the existence or the non-existence of the mucosal thickening on the medial, the posterolateral, the floor, and the roof of maxillary sinus. The obtained results were as followed : 1. In oral radiologist group, the sensitivity, specificity and diagnostic accuracy of Waters' film were 0.7250, 0.8489 and 0.7578 respectively. 2. The sensitivity and the diagnostic accuracy in oral radiologist group were higher than those of non-oral radiologist group (P<0.05), but there was no significant difference between two groups in the specificity (P>0.05), 3. There was no significant difference of the diagnostic abilities except the specificity in oral radiologist group between Waters' radiography and Waters' radiography with panoramic radiography (P>0.05). 4. The sensitivity and the diagnostic accuracy were the highest in the case of medial wall interpretation, the specificity was the highest in the posterolateral wall. 5. In the posterolateral wall and the floor, the sensitivity and the diagnostic accuracy of oral radiologist group were higher than those of non-oral radiologist group (P<0.05).

  • PDF

FLIP CHIP ON ORGANIC BOARD TECHNOLOGY USING MODIFIED ANISOTROPIC CONDUCTIVE FILMS AND ELECTROLESS NICKEL/GOLD BUMP

  • Yim, Myung-Jin;Jeon, Young-Doo;Paik, Kyung-Wook
    • 마이크로전자및패키징학회지
    • /
    • 제6권2호
    • /
    • pp.13-21
    • /
    • 1999
  • Flip chip assembly directly on organic boards offers miniaturization of package size as well as reduction in interconnection distances resulting in a high performance and cost-competitive Packaging method. This paper describes the investigation of alternative low cost flip-chip mounting processes using electroless Ni/Au bump and anisotropic conductive adhesives/films as an interconnection material on organic boards such as FR-4. As bumps for flip chip, electroless Ni/Au plating was performed and characterized in mechanical and metallurgical point of view. Effect of annealing on Ni bump characteristics informed that the formation of crystalline nickel with $Ni_3$P precipitation above $300^{\circ}C$ causes an increase of hardness and an increase of the intrinsic stress resulting in a reliability limitation. As an interconnection material, modified ACFs composed of nickel conductive fillers for electrical conductor and non-conductive inorganic fillers for modification of film properties such as coefficient of thermal expansion(CTE) and tensile strength were formulated for improved electrical and mechanical properties of ACF interconnection. The thermal fatigue life of ACA/F flip chip on organic board limited by the thermal expansion mismatch between the chip and the board could be increased by a modified ACA/F. Three ACF materials with different CTE values were prepared and bonded between Si chip and FR-4 board for the thermal strain measurement using moire interferometry. The thermal strain of ACF interconnection layer induced by temperature excursion of $80^{\circ}C$ was decreased with decreasing CTEs of ACF materials.

  • PDF

시간의 조정을 통한 내러티브 연구 : <데드 아일랜드> 예고편 분석을 중심으로 (A Study on Narrative by the Control of the Time: Focused on the Analysis of the Trailer for Dead Island)

  • 노철환
    • 만화애니메이션 연구
    • /
    • 통권40호
    • /
    • pp.397-421
    • /
    • 2015
  • 새로움은 전통의 틀을 활용함과 동시에 극복하면서 태어난다. 대표적인 고전 내러티브는 아리스토텔레스의 "시학"을 그 시작으로 삼는다. "시학"은 3막구조, 미메시스와 카타르시스, 플롯(미토스)과 캐릭터(에토스), 깨달음과 반전 등을 극작(dramatrurgy)의 근간으로 제시했다. 내러티브의 핵심은 인물을 설정하고, 그들이 겪는 사건의 원인에서 결과에 이르는 과정이다. 이때 극적 효과를 높이기 위해 플롯이 강조된다. 아리스토텔레스가 효과적인 이야기를 위해 가장 중요하다고 여긴 플롯은 고전 내러티브만이 아니라, 내러티브적 성향을 가지고 있는 현대 모든 영상물에서도 그 중요성이 두드러진다. 본 연구는 "시학" 이래 구축된 전통적인 내러티브 방식에 대한 이해와 함께, 새로운 플롯 활용의 사례로서, 2011년 칸광고제에서 인터넷영화 부문 수상작인 <데드 아일랜드>의 예고편(이하 ''로 표기)을 분석한다. 예고편은 보다 많은 관객 또는 소비자를 만들기 위한 목적을 가진 광고이다. 은 역할에 충실한 광고임과 동시에 완성된 내러티브를 가진 3D 단편 애니메이션 작품이다. 본편 게임과 시공간 배경과 세계관을 공유할 뿐, 전혀 다른 인물들과 사건으로 진행된다. 그 인물과 사건이 특별한 것만은 아니다. 대신 은 아리스토텔레스가 한 번도 다루지 않은 시간의 개념을 조정함으로써 독특한 플롯 구성을 선보인다. 특히 비선형적(non-linear)인 구조로 원인과 결과라는 시간적 연계가 독특하게 형성되어 있다. 본 연구는 시간의 배열, 방향, 속도 조정을 통해서 이 평범한 내러티브를 어떻게 극복하고, 의미 창출에 도달하는지 알아본다. 이를 위해 내러티브와 쇼트분석을 시도한다. 나아가 영상물의 내러티브가 가질 수 있는 시간 변형의 또 다른 개념의 존재를 모색한다. 이를 위해 "시학"의 주요 개념과 함께 주네트($G{\acute{e}}rard$ Genette)의 내러티브 연구를 참조한다.

유전체 다중층을 이용한 국소 표면 플라즈몬 공명 센서의 감도 향상에 관한 연구 (Estimation of Sensitivity Enhancements on Localized Surface Plasmon Resonance Sensor Using Dielectric Multilayer)

  • 안희상;강태영;오진우;김규정
    • 한국광학회지
    • /
    • 제28권1호
    • /
    • pp.28-32
    • /
    • 2017
  • 본 논문에서는 LSPR 센서에 적용하기 위한 제한된 높이 100 nm에서 $TiO_2$, $SiO_2$의 다중층을 이용한 LSPR 센서를 디자인을 제안했다. LSPR 센서의 구조는 유전체 층과 나노 구조가 있는 금속층으로 디자인 하였다. 금속층은 금 박막 40 nm와 높이 40 nm, 주기 600 nm, 선폭 300 nm인 나노와이어 구조체를 올려놓은 구조로 디자인하였다. 유전체 층의 높이를 100nm로 제한하고, $TiO_2$, $SiO_2$가 반복되는 구조로 하여 반복층의 개수를 1~4개로 변경하면서 비교 분석하였다. 파장 가변형 SPR을 디자인하기 위해 각도를 75도로 고정하고 파장을 변화시켜 FEM방식으로 계산하였다. 결과로 굴절율이 고정되어 있을 때 다중층의 개수가 증가할수록 공명 파장이 짧아지는 현상을 확인 하였고, 파장의 변화에 더 민감하게 변화하는 것을 측정하였다. 다만, 다중층의 개수가 3개층 이상이 되면 변화하지 않는 것을 확인하였다.

안구내 악성종양에 대한 저준위 방사선요법에 관한 연구 (A study of Brachytherapy for Intraocular Tumor)

  • 지광수;유대헌;이성구;김재휴;지영훈
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.19-27
    • /
    • 1996
  • 연구의 목적 및 중요성 안구에 발생하는 악성종양의 치료에 일반적으로 사용되는 적출술이나 외부 방사선치료법은 시력상실 및 충분한 종양선량을 얻을 수 없는 단점이 있다. 최근 들어 기존치료법의 단점들을 줄이면서 치료 효과를 높이기 위한 치료법으로서 방사성동위원소가 삽입된 기구를 이용한 근접 방사선요법이 외국에서 개발되어 시행되고 있다. 본 연구에서는 안구내 악성종양의 새로운 치료법인 근접 방사성요법을 시행하기 위하여 접합한 형태의 기구를 개발하고, 기구에서 방출되는 방사선의 선량 및 선량분포측정을 통하여 종양 및 주변조직에 분포되는 선량을 보다 정확하게 계산해 보고자 하였다. 연구의 내용 및 범위 안구내 악성종양의 치료를 위한 근접 방사선요법의 연구를 위하여, 1. 안구의 모델을 결정하고, 적당한 방사성동위원소를 선택하였으며, 2. 적합한 형태의 기구를 설계 및 제작하고, 3. 제작된 기구의 방사선 투과계수 및 기구에서 방출되는 방사선의 선량분포를 측정하였으며, 4. 이들 측정 결과와 기존의 컴퓨터 선량계산모델들의 계산 결과와 비교하였다. 연구 결과 및 활용에 대한 건의 본 연구를 통해 다음과 같은 결과를 얻었다. 1. 안구의 모델은 지름 25mm인 구형으로 결정하였으며, 근접 치료에 사용될 방사성동위원소는 크기, 반감기, 발생 방사선의 에너지 및 구입의 용이성 등을 고려하여 Ir-192가 가장 적합한 것으로 판단되었다. 2. 기구는 인체 조직과의 생물학적 반응 및 피폭 선량 차폐를 고려하여 순금으로 제작하였으며, 기구의 크기는 지름이 15mm, 17mm 및 20mm인 3종류로 하였고, 두께는 모두 1.5mm로 하였다. 3. 기구의 방사선 투과계수를 TLD 및 Film으로 측정한 결과 표면에서 모두 0.71, 표면의 1.5mm거리에서 각각 0.45, 0.49이었다. 4. Ir-192가 삽입된 기구의 선량분포 측정 결과를 Gary Luxton 등의 컴퓨터 선량계산모델 및 원자력병원에서 보유하고 있는 방사선 치료계획장치인 CAP-PLAN의 선량계산모델의 계산 결과와 비교하여, 흡수선량은 ${\pm}10\%$ 이내에서 거리로는 0.4mm 이내에서 대부분 일치하였다. 최대 오차는 각각 $11.3\%$ 및 0.8mm로 나타났다. 이상의 결과들로부터 새로 개발한 금으로 된 기구와 Ir-192 seed를 이용한 근접 방사선 치료법으로 안구의 악성종양에 대한 치료를 보다 효과적으로 시행할 수 있을 것으로 기대된다.

  • PDF

안경렌즈코팅용 소형 Sputter Coating System 설계 및 제작에 관한 연구 (Design and Fabrication of Sputter Coating System for Ophthalmic Lens)

  • 박문찬;정부영;김응순;이종근;주경복;문희성
    • 한국안광학회지
    • /
    • 제13권1호
    • /
    • pp.53-58
    • /
    • 2008
  • 목적: 안경렌즈용 소형 suptter coating system을 설계하고 제작하고자 한다. 방법: sputter system의 target 설계에 있어서 Essential Macleod thinfilm design software를 이용해 AR 코팅과 mirror 코팅이 동시에 설계 가능한 Si target 을 결정하였으며. 그 후 sputtering 장비를 제작하였다. 결과: $SiO_2$$Si_3N_4$의 5층 박막으로 구성되는 AR 코팅의 최적조건은 [air|$SiO_2$(81.3)|$Si_3N_4$(102)|$SiO_2$(19.21)|$Si_3N_4$(15.95)| $SiO_2$(102)|glass] 이였다. Mirror 코팅의 경우, blue color 코팅의 최적조건은 [air|$SiO_2$(56.61)|$Si_3N_4$(135.86)|$SiO_2$(67.64)| $Si_3N_4$(55.4)|$SiO_2$ (53.53)|$Si_3N_4$(51.28)|glass] 이고, green color 코팅의 최적조건은 [air|$SiO_2$(66.2)|$Si_3N_4$(22.76)|$SiO_2$(56.58)| $Si_3N_4$(140.35) |$SiO_2$(152.35)|$Si_3N_4$(70.16)|$SiO_2$(121.87)|glass] 이였으며, gold color 코팅의 최적조건은 [air|$SiO_2$(83.59)|$Si_3N_4$(144.86) |$SiO_2$(11.82)|$Si_3N_4$(129.93)|$SiO_2$(90.01)|$Si_3N_4$(88.37)|glass] 이였다. 결론: 코팅 시간을 줄여 안경단가를 줄이기 위하여 안경렌즈 코팅 시 렌즈의 전 후면을 동시에 코팅을 해야 하기 때문에 sputtering장비 설계를 할 때 안경렌즈 전면과 후면에 동일하게 Si target을 갖춘 cathode를 사용하였고, 렌즈의 곡률을 고려하여 각 층이 동일하게 코팅이 되어야 하기 때문에 target-substrate 간의 간격은 12.5 cm에서 20 cm로 가변할 수 있도록 설계하고 제작하였다. 고품질의 안경렌즈 코팅을 위하여 고진공 펌프로 turbo pump를 이용하였으며, 코팅박막의 균일함을 얻기 위해서 치구를 회전할 수 있도록 설계하고 제작하였다.

  • PDF

구상형 실리카 필러가 실험적 복합레진의 물성에 미치는 효과 (EFFECT OF SPHERICAL SILICA FILLER ON THE PHYSICAL PROPERTIES OF EXPERIMENTAL COMPOSITES)

  • 강승훈;박상진;민병순;최호영;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.88-99
    • /
    • 1999
  • The purpose of this study was to investigate the physical properties of experimental composite resins made with the spherical and crushed fillers. The 14 experimental composite resins containing 0, 5, 10, 15, 20 and 25%(w/w) in spherical filler group and 0, 10, 20, 30, 40, 50, 60 and 70%(w/w) in crushed filler group, incorporated in a Bis-GMA matrix (Aldrich Co., USA), were made with 1% ${\gamma}$-methoxy silane treated fillers. The polymer matrix was made by dissolving 0.7%(w/w) of benzoyl peroxide(Janssen Chemical Co. Japan) in methacrylate monomer, whereupon 0.7%(v/v) N,N-dimethyl-p-toluidine(Tokyo Kasei Co. Japan) was added to the monomer. The weight percentage of each specific particle size distribution could be determined from a knowledge of the specific gravity, the weight(w/w), and corresponding volume %(v/v) of the filler sample in resin monomer. In crushed silica group and spherical silica group, the diametral tensile strengths and compressive strengths were measured with Instron Testing Machine(No.4467), and analyzed in 14 experimental composite resins made by filler fractions. The shear bond strength of 14 experimental composite resins to bovine enamel was measured with universal testing machine(Instron No.4467). The fracture surfaces were sputter-coated with a gold film and investigated by SEM. The results were as follows; 1. The diametral tensile strength was tendency to increase in crushed silica group, but not in spherical silica group. The highest diametral tensile strength was found in 20% filler fractions of two groups. 2. The compressive strength was higher in 15%(w/w) and 20%(w/w) in spherical silica group than in crushed silica group, but not in spherical silica group. 3. The significant correlation was noticed in increase in shear bond strength in crushed silica group, but not in spherical silica group. 4. The significantly highest shear bond strength was noticed in 50% filler concentration in crushed silica group, and in 15% filler concentration in spherical silica group, it was not significant in relation. 5. In crushed silica group, cut surface of resin matrix and the interface between resin and filler is obvious. In spherical silica group, fractures that occurred through the filler particles were round in shape.

  • PDF

Simultaneous Transfer and Patterning of CVD-Grown Graphene with No Polymeric Residues by Using a Metal Etch Mask

  • 장미;정진혁;;이내응
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.642-642
    • /
    • 2013
  • Graphene, two dimensional single layer of carbon atoms, has tremendous attention due to its superior property such as high electron mobility, high thermal conductivity and optical transparency. Especially, chemical vapor deposition (CVD) grown graphene has been used as a promising material for high quality and large-scale graphene film. Unfortunately, although CVD-grown graphene has strong advantages, application of the CVD-grown graphene is limited due to ineffective transfer process that delivers the graphene onto a desired substrate by using polymer support layer such as PMMA(polymethyl methacrylate). The transferred CVD-grown graphene has serious drawback due to remaining polymeric residues generated during transfer process, which induces the poor physical and electrical characteristics by a p-doping effect and impurity scattering. To solve such issue incurred during polymer transfer process of CVD-grown graphene, various approaches including thermal annealing, chemical cleaning, mechanical cleaning have been tried but were not successful in getting rid of polymeric residues. On the other hand, lithographical patterning of graphene is an essential step in any form of microelectronic processing and most of conventional lithographic techniques employ photoresist for the definition of graphene patterns on substrates. But, application of photoresist is undesirable because of the presence of residual polymers that contaminate the graphene surface consistent with the effects generated during transfer process. Therefore, in order to fully utilize the excellent properties of CVD-grown graphene, new approach of transfer and patterning techniques which can avoid polymeric residue problem needs to be developed. In this work, we carried out transfer and patterning process simultaneously with no polymeric residue by using a metal etch mask. The patterned thin gold layer was deposited on CVD-grown graphene instead of photoresists in order to make much cleaner and smoother surface and then transferred onto a desired substrate with PMMA, which does not directly contact with graphene surface. We compare the surface properties and patterning morphology of graphene by scanning electron microscopy (SEM), atomic force microscopy(AFM) and Raman spectroscopy. Comparison with the effect of residual polymer and metal on performance of graphene FET will be discussed.

  • PDF

A STUDY ON MECHANICAL PROPERTIES OF TiN, ZrN AND WC COATED FILM ON THE TITANIUM ALLOY SURFACE

  • Oh, Dong-Joon;Kim, Hee-Jung;Chung, Chae-Heon
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.740-750
    • /
    • 2006
  • Statement of problems. In an attempt to reduce screw loosening, dry lubricant coatings such as pure gold or tefron have been applied to the abutment screw. However, under repeated tightening and loosening procedures, low wear resistance and adhesion strength of coating material produced free particles on the surface of abutment screw and increased frictional resistance resulting in screw tightening problems. Purpose. The aim of this study was to compare friction coefficient, adhesion strength, vickers hardness and evaluate coating surface of titanium alloy specimens coated with TiN(titanium nitride), ZrN(zirconium nitride) and WC(tungsten carbide). Material and method. Titanium alloy(Ti-6Al-4V) discs of 12mm in diameter and 1mm in thickness divided into 4 groups. TiN, ZrN and WC was coated for the specimens of 3 groups respectively, and those of 1 group were not coated. Each group was made up of 4 specimens. In this study, sputtering method was used among the PVD(Physical Vapor Deposition) techniques available for TiN, ZrN and WC coatings. Friction coefficient, adhesion strength, vickers hardness and coating surface of 4 groups were measured. Results. 1. For all three coating conditions, friction coefficient was significantly decreased. Especially, ZrN coated surface showed the lowest value. $TiN(0.39{\pm}0.02)$, $ZrN(0.24{\pm}0.01)$, $WC(0.31{\pm}0.03)$. 2. TiN coating showed the highest adhesion strength, however ZrN coating had the lowest value. $TiN(25.3N{\pm}1.6)$, $ZrN(14.8N{\pm}0.6)$, $ WC(18.4N{\pm}0.7)$. 3. Vickers hardness of all three coatings was remarkably increased as compared with that of none coated specimen. TiN coating had the highest Vickers hardness, however WC coating showed the lowest value. $TiN(1865.2{\pm}33.8)$, $ZrN(1814.4{\pm}18.6)$, $WC(1008.5{\pm}35.9)$. 4. The ZrN or WC coated specimen showed a homogeneous and smooth surface, however the rough surface with defects was observed for TiN coating. Conclusions. When TiN, ZrN and WC coating applied to the abutment screw, frictional resistance would be reduced, as a result, the greater preload and prevention of the screw loosening could be expected.

저온검출기를 이용한 에너지 고 분해능 알파분광 구현 (High Energy Resolution Alpha Spectrometer Using a Cryogenic Detector)

  • 김민성;이상훈;윤원식;장용식;이상준;김용함;이민규
    • Journal of Radiation Protection and Research
    • /
    • 제38권3호
    • /
    • pp.132-137
    • /
    • 2013
  • 기존에 많이 사용된 반도체 검출기의 분해능은 통계학적 이론으로 그 분해능의 한계가 따른다. 이러한 이유로 최근에 반도체 검출기가 갖는 에너지 분해능의 한계를 뛰어넘는 저온 검출기를 이용하여 다양한 방사성 핵종 분석을 시도하고 있다. 본 논문에서는 $2{\times}2{\times}0.05mm^3$ 크기 금막 흡수체에 입사하는 에너지 때문에 흡수체의 온도가 상승하는 원리를 이용해 $^{241}Am$ 알파 선원의 에너지를 측정하였다. 흡수체의 온도 변화 측정에는 자기양자센서인 Au:Er를 이용하였으며 이는 순수한 Au에 핵스핀이 0 인 $^{168}Er$을 수백 ppm을 첨가하여 얻은 상자성 합금이다. 알파 입자 흡수에 의한 미세한 온도증가를 측정하기 위해서 희석식 냉동기보다 작동이 편리한 무냉매 자기냉동기를 이용해 mK 온도 영역의 저온환경을 구성하였다. $^{241}Am$ 선원 측정 결과 5.5 MeV에서 6.8 keV의 FWHM의 에너지 고 분해능을 얻었다.