• Title/Summary/Keyword: glassy carbon electrode

Search Result 171, Processing Time 0.022 seconds

Study on Electrode Selection for Electrochemical Detection of Cadmium and Lead (카드뮴과 납 전기화학적 검출을 위한 전극선정에 관한 연구)

  • Kim, Hak-Jin;Kim, Ki-Young;Moh, Chang-Yeon;Cho, Han-Keun
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.404-409
    • /
    • 2008
  • Excessive presence of heavy metals in environment affects plants and fruits grown in the contaminated area. Rapid on-site monitoring of heavy metals can provide useful information for efficiently characterizing heavy metal-contaminated sites and for minimizing the exposure of the contaminated food crops to humans. This study reports on the evaluation of gold and glassy carbon (GC) electrodes with mercury or bismuth as a coating material for simultaneous determination of cadmium (Cd) and lead (Pb) in 0.1 M $HNO_3$ solution by anodic stripping voltammetry (ASV). The use of a square-wave voltammetric potential between a working electrode and a reference electrode caused Cd and Pb ions deposited on the electrode surface to be oxidized, thereby generating electric currents at different potentials. The mercury-coated gold electrode was not sensitive enough to detect the usable range of Cd concentrations (1 to 100 ppb). The GC electrodes with mercury or bismuth displayed well-defined, sharp and separate current peaks for Cd and Pb ions when the square-wave voltammetric potentials were applied. The peak currents measured with both mercury- and bismuth- coated GC electrodes were linearly proportional to Cd and Pb concentrations in the range of 1 to 200 ppb in 0.1 M $HNO_3$ with strong linear relationships between concentration and peak current ($R^2$ > 0.95), indicating that both of Cd and Pb ions could be quantitatively measured.

Determination of Lead(II) at Nation-Coated Glassy Carbon Electrodes Modified by Tetren-Glycerol (Nafion-Tetren-Glycerol이 수식된 유리탄소전극에서 납(II) 이온의 정량)

  • 반옥기;박은희;정근호
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.62-68
    • /
    • 2003
  • Differential pulse voltammetry (DPV) using nafion-coated glassy carbon electrodes modified with Tetren(tetraethylene pentamine)-glycerol showed sensitivity for determining lead (II) at low concentration. The Lead (II) was accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface was characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry. Various experimental parameters, such as the composition of modifier, preconcentration time, pH of electrolyte (0.1 M acetate buffer), and parameters of differential pulse voltammetry, were optimized. The initial potential was applied for 50 s, the electrode was scanned from -0.9 to -0.3 V, and the anodic peak current was measured at -0.604 V $\pm$ 0.015 V (vs. Ag/AgCl). The calibration plot was obtained in the range 1.0$\times$10$^{-8}$ M~l.0$\times$10$^{-6}$ M with pH 4.5 buffer solution. The detection limit (3$\sigma$) it as low as 5.0$\times$ 10$^{-9}$ M. This method is applied to the determination of lead(II) in a certified reference material and the result agrees satisfactorily with the certified value.

The Manganese Oxide which has Modified Electrochemically Affects in Oxygen Reduction Reaction (전기화학적으로 석출된 망간 산화물이 산소 환원 반응에 미치는 영향)

  • Park, Sung-Ho;Shin, Hyun-Soo;Kim, Jeong-Sik;Park, Soo-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.2
    • /
    • pp.132-137
    • /
    • 2010
  • This study is concerned the electrocatalytic generation of oxygen gas at electrochemically deposited manganese oxide electrode in KOH solution. Manganese oxide nanoparticles electrodeposited onto relatively substrate, e.g glassy carbon, Au, Ti electrode. MnOx is electrodeposited in nanorod structure which cover the overall surface of the substrate. The $\gamma$-MnOOH that is kind of manganese oxide species plays a significant role as a catalytic mediator, which promote 4-electron reduction process. Modified electrodes with electrodeposited manganese oxide structures resulted in significant decrease in the anodic polarization compared with the unmodified electrodes in alkaline media.

Nanostructured Metal Organic Framework Modified Glassy Carbon Electrode as a High Efficient Non-Enzymatic Amperometric Sensor for Electrochemical Detection of H2O2

  • Naseri, Maryam;Fotouhi, Lida;Ehsani, Ali
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.28-36
    • /
    • 2018
  • Metal-organic frameworks have recently been considered very promising modifiers in electrochemical analysis due to their unique characteristics among which tunable pore sizes, crystalline ordered structures, large surface areas and chemical tenability are worth noting. In the present research, $Cu(btec)_{0.5}DMF$ was electrodeposited on the surface of glassy carbon electrode at room temperature under cathodic potential and was initially used as the active materials for the detection of $H_2O_2$. The cyclic voltammogram of $Cu(btec)_{0.5}DMF$ modified GC electrode shows distinct redox peaks potentials at +0.002 and +0.212 V in 0.1 M phosphate buffer solution (pH 6.5) corresponding to $Cu^{(II)}/Cu^{(I)}$ in $Cu(btec)_{0.5}DMF$. Acting as the electrode materials of a non-enzymatic $H_2O_2$ biosensor, the $Cu(btec)_{0.5}DMF$ brings about a promising electrocatalytic performance. The high electrocatalytic activity of the $Cu(btec)_{0.5}DMF$ modified GC electrode is demonstrated by the amperometric response towards $H_2O_2$ reduction with a wide linear range from $5{\mu}M$ to $8000{\mu}M$, a low detection limit of $0.865{\mu}M$, good stability and high selectivity at an applied potential of -0.2 V, which was higher than some $H_2O_2$ biosensors.

Electropolymerization Mechanism for Poly(o-phenylenediamine) (PPD) and Its Electrocatalytic Behavior for $O_2$ Reduction

  • Jang, Dong Hun;Yu, Yong Seop;O, Seung Mo
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.5
    • /
    • pp.392-397
    • /
    • 1995
  • o-Phenylenediamine (o-PD) was electropolymerized on glassy carbon electrodes under a potential cycling condition. The resulting polymer films mediated electrons for the reduction of molecular oxygen at pH=1.0. It was found from the RDE, RRDE, and cyclic voltammetry experiments that the modified electrodes reduce oxygen to hydrogen peroxide at about 300 mV lower potential than the bare glassy carbon electrode. The polymer film consisted of more than two components. Among those, only one component was active in oxygen reduction, which was formed mainly in the earlier stage of the electropolymerization. 2,3-Diaminophenazine, a cyclic dimer of o-PD, was also active in the oxygen reduction reaction, from which it was suggested that the active polymeric component has a structural unit similar to the cyclic dimer. Finally, the electropolymerization mechanism for the formation of the active and inactive components has been proposed.

Electrocatalytic Reduction of Dioxygen at Glassy Carbon Electrodes with Irreversible Self-assembly of N-hexadecyl-N'-methyl Viologen

  • Lee, Chi-Woo;Jang, Jai-Man
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.7
    • /
    • pp.563-567
    • /
    • 1994
  • The electroreduction of dioxygen at glassy carbon electrodes with irreversible self-assembly of N-hexadecyl-N'-methyl viologen $(C_{16}VC_1)$ proceeds at potentials more positive than those where the reduction occurs at bare electrodes. The electrocatalyzed reduction takes place at potentials well ahead of those where the catalyst is reduced in the absence of dioxygen and the limiting currents observed at rotating disk electrodes did not deviate from the thoretical Levich line up to 6400 rpm, indicating that the electrocatalysis is extremely rapid. The rate constant for the heterogeneous reaction between $C_{16}V^+C_1$ immobilized on the electrode surface and $O_2$ in solution was estimated to be ca. $10^8\;M^{-1}s^{-1}$. The half-wave potential of dioxygen reduction was independent of solution pH.

The Electrocatalytic Reduction of Molecular Oxygen with a Co(Ⅱ)-Glyoxal Bis(2-hydroxyanil) Complex Coated Electrode

  • 정의덕;원미숙;심윤보
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.4
    • /
    • pp.417-422
    • /
    • 1998
  • The electrocatalytic reduction of molecular oxygen was investigated with a Co(II)-glyoxal bis(2-hydroxyanil) complex coated-glassy carbon (GC) electrode in aqueous media. The reduction of $O_2$ at the modified electrode was an irreversible and diffusion-controlled reaction. The complex coated-GC electrode demonstrated an excellent electrocatalytic effect for $O_2$ reduction in an acetate buffer solution of pH 3.2. The coated electrode made the $O_2$ reduction potential shift of 60-510 mV in a positive direction compared to the bare GC electrode depending on pH. The Co(II)-glyoxal bis(2-hydroxyanil) coated electrode converted about 51% of the $O_2$ to $H_2O_2$ via a two-electron reduction pathway, with the balance converted to H_2O$.

Selective Monitoring of Rutin and Quercetin based on a Novel Multi-wall Carbon Nanotube-coated Glassy Carbon Electrode Modified with Microbial Carbohydrates α-Cyclosophorohexadecaose and Succinoglycan Monomer M3

  • Jin, Joon-Hyung;Cho, Eun-Ae;Kwon, Chan-Ho;Jung, Seun-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1897-1901
    • /
    • 2010
  • Multi-wall carbon nanotube (MWNT)-modified glassy carbon electrodes (GCE) were prepared for simultaneous determination of rutin and quercetin. Microbial carbohydrates, $\alpha$-cyclosophorohexadecaose ($\alpha$-C16) and succinoglycan monomer M3 (M3) were doped into MWNTs to prepare a $\alpha$-C16-doped MWNT-modified GCE (($\alpha$-C16 + MWNTs)/GCE) and a M3-doped MWNT-modified GCE ((M3 + MWNTs)/GCE), respectively. The sensitivities of the ($\alpha$-C16 + MWNTs)/GCE to rutin and quercetin were 34.7 ${\mu}A\cdot{\mu}M^{-1}{\cdot}cm^{-2}$ and 18.3 ${\mu}A\cdot{\mu}M^{-1}{\cdot}cm^{-2}$, respectively, in a linear range of $2\sim8{\mu}M$ at pH 7.2. The sensitivities of the (M3 + MWNTs)/GCE was 2.44 ${\mu}A\cdot{\mu}M^{-1}{\cdot}cm^{-2}$ for rutin and 7.19 ${\mu}A\cdot{\mu}M^{-1}{\cdot}cm^{-2}$ for quercetin without interference.

Effect of Electrode Materials and Applied Potential in Electrocatalytic Reduction of Carbon Dioxide by Carbon Monoxide Dehydrogenase (일산화탄소탈수소화효소를 이용한 이산화탄소의 전기화학적 환원에 미치는 전극재료와 전위의 영향)

  • Shin, Jun Won;Kim, You-Sung;Song, Ji-Eun;Lee, Sang-Hee;Lee, Sang-Phil;Lee, Ho-Jun;Lim, Mi-Ran;Shin, Woon-Sup
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.3
    • /
    • pp.165-169
    • /
    • 2008
  • The effect of reduction of carbon dioxide by CODH(Carbon Monoxide Dehydrogenase) was compared on glassy carbon and gold working electrodes. In case of gold electrode, the choice of the optimum applied potential is very important since $H_2$ evolution can be mixed with $CO_2$ reduction. On the other hand, efficient $CO_2$ reduction was observed up to -650 mV vs. NHE on glassy carbon in neutral solution due to the larger overpotential for $H_2$ evolution on glassy carbon surface than that on gold surface. The optimum potential for $CO_2$ reduction was found to be $-570{\sim}600\;mV$ vs. NHE. The current efficiency of $CO_2$ to CO decreased dramatically at more negative potential according to the activity of enzyme decrease and the hydrogen evolution.