• Title/Summary/Keyword: glass wool

Search Result 122, Processing Time 0.02 seconds

A Study on the Sound Absorption Coefficient by Varying Sample Size (시편의 크기에 따른 흡음계수 변화 연구)

  • Jung, Sung-Soo;Lee, Woo-Seop;Jho, Moon-Jae;Suh, Sang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.185-190
    • /
    • 2000
  • The sound absorption coefficient of glass wool (bulk density of 48 kg/$m^3$ and 32 kg/$m^3$) was measured by reverberation room method as varying their cross-sectional area. The results show that the absorption is larger for smaller samples because of edge effect. The absorption coefficient with two different kinds of sources, 1/3-octave band and white noise, gives similar values.

  • PDF

Precision analysis on the ISO 13784-1's Round Robin scenarios (ISO 13784-1 RRT 결과의 정밀도 분석)

  • Park, Kye-Won;Jeong, Jae-Gun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.333-336
    • /
    • 2012
  • ISO 13784-1 sandwich panel tests were conducted by FILK, KICT in Korea, SP in Sweden and CSIRO in Australia. Sandwich panels composed of steel sheets, EPS and glass wool supplied by FILK were tested. Mainly heat release rate was compared and equlity of distribution also analyzed on the point of statistical view based on ISO.

  • PDF

Analysis on International Round Robin Test's Result by ISO 13784-1 Standard (ISO 13784-1 시험 방법에 의한 국제 상호비교 평가 분석)

  • Park, Kye-Won;Jeong, Jae-Gun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.201-204
    • /
    • 2011
  • ISO 13784-1 sandwich panel tests were conducted by FILK, KICT in Korea, SP in Sweden and CSIRO in Australia. Sandwich panels composed of steel sheets, EPS and glass wool supplied by FILK were tested. Mainly heat release rate was compared and equality of distribution also analyzed on the point of statistical view based on ISO.

  • PDF

The Estimation of Surface Temperature of Concrete Frame Caused by Fire (구체콘크리트면에 받는 열온도의 시뮬레이션 실험)

  • Nakagawa. Muneo;Kei. Yanagi
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.272-277
    • /
    • 1997
  • The object of this paper is to analyze the surface temperature of RC structures caused by fire. The experimental analysis is undertaken by using following two methods. 1) Simulation to analyze the relationship between the temperature and the condition change for glass wool caused by fire. 2) Temperature-analysis (TG/DTA tests) of RC structures. From the results of the two experimental analysis, it was possible to estimate the temperature of RC concrete structures caused by fire.

  • PDF

A Study on Fire Hazards in Multiple Compartments with Lightweight Partition Walls (경량칸막이 벽체를 통한 다중구획공간에서의 화재위험성에 관한 연구)

  • Park, Sang-Min;Choi, Su-Gil;Jin, Se-Young;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.14-21
    • /
    • 2020
  • This paper presents the study of a fire risk to the backside of two miniatures of ISO 9705 2/5 using a lightweight partition for indoor space division and reproduction of the ISO 9705 test. An SGP partition, stud partition, glass wool panel, urethane foam panel, sandwich panel, and glass partition were selected as the test specimens, which are frequently used in construction. According to the ISO 9705 test standard, stabilization was achieved using a measuring device that recorded data before the ignition of a burner and continued recording for 120 s thereafter. After ignition was achieved, the power was increased to 300 kW for 600 s and then reduced to 100 kW for 600 s. The specimens were subsequently observed for 180 s, and the fire risk to the backside and the fire pattern of the wall unit were analyzed. Owing to the amount of heat generated by the ignition source, the maximum temperature of the backside was observed to be 67.7 ℃ for the SGP partition, 55.1 ℃ for the stud partition, 52.4 ℃ for the glass wool panel, 727.4 ℃ for the sandwich panel, 561 ℃ for the urethane foam panel, and 630.5 ℃ for the glass partition. In the cases of the sandwich and urethane foam panels, the explosion of flammable gas occurred by virtue of fusion of the interior materials. The reinforced glass was fractured owing to the temperature difference between the heat- and nonheat-responsive parts. Ultimately, the fire risk to the nearby section room was deemed to be high.

A Study on the Sound Absorption Characteristic of Glass Wool Structures Covered by Punched Steel Plate (유공함석판으로 보호된 글라스울 흡음구조체의 흡음특성에 관한 연구)

  • 김석홍;이상엽;권형오
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.65-69
    • /
    • 1991
  • 소음제어대책 수립시, 흡음구조는 공조용소음기, 공업용소음기, Enclosure, 실 내 흡음판등에 폭넓게 이용되고 있다. 흡음구조의 재료중 글라스울은 뛰어난 흡음성능과 고온에서의 내구성 및 난연성등으로 인하여 여러 흡음재료중에 서 가장 많이 이용되고 있으나 글라스율 미립자의 비산 및 강도문제로 글라 스율에 글라스 클로스(Glass Cloth), P.E.Film등과 같은 글라스울 비산방지막 과 유공함석판을 붙인 흡음구조체로 제작하여 이용하는 것이 일반적이다. 국 내외적으로 글라스울만의 흡음율 데이타는 각종 문헌등에 많이 발표되어 있 으나 글라스울에 글라스울 비산방지막과 유공함석판을 붙인 흡음구조체의 흡음율데이타는 거의 없는 실정이다. 본 연구에서는 이러한 글라스울 흡음구 조체의 글라스울의 밀도, 글라스울 비산방지막의 종류, 유공함석판의 유공치 수 등에 따른 흡음특성을 잔향실법 흡음율측정방법에 의해 측정 평가하고 이들을 상호 비교검토하여 각종 소음 제어대책의 기초 설계자료로 제시하고 자 한다.

  • PDF

Adoptive Transfer of Delayed-Type Hypersensitivity to Salmonella typhimurium in Mice (Salmonella typhimurium에 대한 마우스 지연성 과민반응의 입양전달)

  • Lee, Hern-Ku;Chang, Hyun-Chul;Han, Jang-Yun;Ha, Tai-You
    • The Journal of the Korean Society for Microbiology
    • /
    • v.21 no.4
    • /
    • pp.455-460
    • /
    • 1986
  • This study was undertaken to investigate to know whether spleen and lymph node cells from immunized mice can transfer systemically the delayed-type hypersensitivity(DTH) reaction to Salmonella typhimurium and to characterize the lymphoid cells using glass, nylon wool and rabbit anti-mouse thymocyte serum. Mice, C57BL/6 or ICR, were immunized subcutaneously at 11, 8 and 2 days before adoptive systemic transfer with $100{\mu}g$ of protein antigen from S. typhimurium in complete Freund adjuvant. It was found that DTH reaction to S. typhimurium could be transferred to normal recipient systemically by both spleen and lymph node cells($10^8\;cells$, respectively) from immunized mice. The cells responsible for this transfer of DTH reaction were glass nonadherent T lymphocytes.

  • PDF

An Experimental Study on the Effect of Air Space on the Absorption Property of Composite Absorption System (배후공기층이 복합흡음구조의 흡음특성에 미치는 영향에 관한 실험적 연구)

  • Oh, Yang-Ki
    • KIEAE Journal
    • /
    • v.1 no.2
    • /
    • pp.47-54
    • /
    • 2001
  • Single sound absorbers such as porous materials, panels, and Helmholts resonators have limited performance with some extents of frequency region. For example, porous materials do not attenuate low frequency sounds, while panels do not absorb high frequency sounds. Composite absorption structure with coverings, porous materials, and air gaps are an alternative for wide band sound absorption. Slits, panels, perforated panels are those materials for coverings, glass wool, mineral wool, polyester, and polyurethane are frequently used porous materials. Air gap between the porous material and background surface is one of major factors which governs the absorption characteristics of composite absorption structures, especially in the low frequency area. Calculations and measurements show that the absorption coefficients of composite absorption structure, in mid and low frequency bands, are getting higher with increased air gaps. Perforated panels rather than slits and panels are good coverings with higher number as far as absorption coefficient is concerned. Perforated panels with porous materials and 37 cm of air gaps in background have high absorption coefficients for all frequency bands, above 0.7 to 1.0. All measurements are performed in reverberation chamber, Mokpo National University, according to ISO 354 and ISO 3382.

  • PDF

Absorption Characteristics of Perforated Environment Friendly Sound Absorbing Board using Hwangto (황토를 이용한 친환경 유공 흡음보드의 흡음특성)

  • Kim, Sun-Woo;Park, Hyeon Ku
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.3-8
    • /
    • 2011
  • Sound absorbing materials used for lightweight panels and interior material are mainly made of fibroid material such as glass wool or rock wool. However these fiber type sound absorbing materials have some problems such that sound absorption could be decreased as time goes by because of durability. In addition, dust scattering from fiber type material can cause another problem in health. In this point of view, this study aims to develop environment friendly sound absorbing material using Hwangto(so called loess or yellow soil), a traditional housing material. Hwangto is natural housing material in Korea and generally known for improving indoor air quality. Hwangto panel is made to construct on the floor, wall and ceiling, and expected that there is not enough absorption. Present study tried to develop environment friendly sound absorbing material that has high sound absorption performance with good environment performance in terms of air quality. Pore rate was designed to maximize the absorption in the specific frequency bands, and two kinds of backing space were applied in order to see the effect of backing space. As a result peak frequency that has maximum absorption is going high as the pore rate is increased. The backing space provides more absorption and makes the peak frequency down to low.

A Study on the Internal Temperature Reduction of PKG-A Water-jet-room by Substituting Heat Insulation Materials (단열재 개선을 통한 PKG-A Water Jet Room 온도저감 연구)

  • Jung, Young In;Choi, Sang Min
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.3
    • /
    • pp.425-435
    • /
    • 2019
  • Purpose: The purpose of this study was to resolve the Naval ship's Local Operation Panel(LOP) malfunction problems which caused by overheating in summer season and dispatching to equatorial regions. Methods: Instead of using dual type heat insulation materials(consist with ceramic wool and glass wool), aerogel heat insulation materials were used for decreasing heat emissions from gas-turbine heat waste steam pipes passing water-jet- room. Experiment and Computational analysis of heat flow were conducted to analyze the internal room temperature changes. Results: The results of this study are as follows; The aerogel heat insulation materials suppress heat emission more efficiently than dual type insulation materials. The cold surface temperature of insulation was far more decreased and internal room, LOP surface temperature also showed significant results too. Conclusion: The substituted heat insulation materials appeared remarkable performance in decreasing room temperature that it could be used for suppressing the LOP overheatings and malfunctions.