• 제목/요약/키워드: glass toughened glass stem insulator

검색결과 6건 처리시간 0.023초

장간유리애자 파손시 절연파괴 특성 (The Electrical Breakdown Characteristics of Broken Toughened Glass Stem Insulator)

  • 정종욱;정진수;김영석
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1398-1406
    • /
    • 2008
  • This paper describes the electrical breakdown characteristics of broken toughened glass stem insulators by comparing with those of sound ones. The broken toughened glass stem insulators were taken from the electric railway field. According to the international standards, the sound and broken toughened glass stem insulators were tested in electrical strength. In the test, the power frequency voltage and the impulse voltage with a standard waveform were applied to the insulators. The power frequency voltage tests were carried out under both dry and wet condition and the impulse voltage tests under only dry condition. The acquired results were compared one another and discussed in electrical breakdown characteristic by analyzing the flashover progress pictures. As a result, the electrical strength of the broken toughened glass insulators was acquired and the processes of the surface breakdown on the toughened glass insulators were confirmed.

전기철도용 유리애자 전기적 강도 해석 (Electrical Strength Analysis of Toughened Glass Stem Insulator for Electric Railways)

  • 정종욱;정진수;김영석;김선구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.263-263
    • /
    • 2008
  • This paper describes the electrical strength of a toughened glass stem insulators employed for electric railways. The broken glass stem insulators for comparison were taken at site. According to the international standards, electrical strength tests with 60[Hz] voltage and with impulse voltage were carried out to them under dry and wet condition and the results were corrected by considering the temperature and humidity factors. Based on the experimental results, the electrical strength of broken glass stem insulators was compared with those of sound ones and surface flashover characteristics were also discussed. As a result, it was confirmed that the electrical discharge is formed by bridging each end of the insulator shell. The experimental results are expected to be utilized as data for electrically identifying the failure causes of glass insulators.

  • PDF

고속전차선로 유리애자 현장 적합성 기반 구축 연구 (The Suitability of Toughened Glass Stem Insulator for Korea High Speed Catenary System)

  • 이기천;전용주;이종우
    • 한국철도학회논문집
    • /
    • 제12권2호
    • /
    • pp.243-248
    • /
    • 2009
  • 고속철도의 전차선로에 사용되는 유리애자는 국내에 적용 사례가 없으며 해외에서도 프랑스를 중심으로 한 정적으로 적용되는 품목으로서 국내 적용시 특성분석을 통한 적합성 평가가 요구된다. 본 논문에서는 2004년 이후 운영데이터를 바탕으로 유리애자의 현장 적합성을 평가하기 위해 전기적, 기계적, 외부적(환경) 요인의 3가지 대항목을 선정하여 분야별로 특성 분석을 수행하여 기초데이터를 축적하고 적합성을 평가하였다.

고속전차선로 유리애자 현장 적합성 기초연구 (Basic analysis of suitability for Toughened Glass Stem Insulator applied in the high speed catenary system)

  • 전용주;류영태;이기천;이유경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1067-1068
    • /
    • 2008
  • The Operation of high speed train in year 2004 bring about a great change in railroad industry. Especially in railroad construction field we have acquired great Know-how. And up to now we are building up operation skills. But the high speed train system are totally imported, so it is necessary to investigate some of the equipment based on our own environment. In case of Toughened Glass Stem Insulator, we don't have any application case in domestic and limited in abroad. So there must be some characteristic estimation. The estimation was made in three different ways. First electrical field cause, Second physical field cause and finally in circumstance cause. In Electrical field cause, amplitude and number of time for abnormal peak voltage data are collected. And in physical field cause, amplitude and trend of vibration in to the insulator are examined. And I circumstance cause, possibility of flying gravel and ice clod are investigated. Through this basic data suitability for Toughened Glass Stem Insulator using in domestic will be accumulated.

  • PDF

고속전차선로 유리애자 현장 적합성 기초연구 (Basic analysis of suitability for Toughened Glass Stem Insulator applied in the high speed catenary system)

  • 전용주;류영태;이기천;이유경
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.423-427
    • /
    • 2008
  • The Operation of high speed train in year 2004 bring about a great change in railroad industry. Especially in railroad construction field we have acquired great Know-how. And up to now we are building up operation skills. But the high speed train system are totally imported, so it is necessary to investigate some of the equipment based on our own environment. In case of Toughened Glass Stem Insulator, we don't have any application case in domestic and limited in abroad. So there must be some characteristic estimation. The estimation was made in three different ways. First electrical field cause, Second physical field cause and finally in circumstance cause. In Electrical field cause, amplitude and number of time for abnormal peak voltage data are collected. And in physical field cause, amplitude and trend of vibration in to the insulator are examined. And I circumstance cause, possibility of flying gravel and ice clod are investigated. Through this basic data suitability for Toughened Glass Stem Insulator using in domestic will be accumulated.

  • PDF

고속전차선로 유리애자 현장 적합성 기반 구축 연구 (Base data establishment of suitability for Toughened Glass Stem Insulator applied in the high speed catenary system)

  • 전용주;류영태;이태훈;박기범;이기천;김선구
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.140-143
    • /
    • 2008
  • The Operation of high speed train in year 2004 bring about a great change in railroad industry. Especially in railroad construction field we have acquired great Know-how. And up to now we are building up operation skills. But the high speed train system are totally imported, so it is necessary to investigate some of the equipment based on our own environment. In case of Toughened Glass Stem Insulator, we don't have any application case in domestic and limited in abroad. So there must be some characteristic estimation. This paper introduces estimation methode in three different field. First electrical field, Second physical field and finally environment circumstance. In Electrical field, amplitude and number of time for abnormal peak voltage data are collected. And in physical field case, amplitude and trend of vibration in to the insulator are examined. And I circumstance case, possibility of flying gravel and ice clod are investigated. Through this basic data, suitability for Toughened Glass Stem Insulator using in domestic will be accumulated and estimated.

  • PDF