• Title/Summary/Keyword: glass protection

Search Result 136, Processing Time 0.024 seconds

Development of Highly Reliable Power and Communication System for Essential Instruments Under Severe Accidents in NPP

  • Choi, Bo Hwan;Jang, Gi Chan;Shin, Sung Min;Lee, Soo Ill;Kang, Hyun Gook;Rim, Chun Taek
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1206-1218
    • /
    • 2016
  • This article proposes a highly reliable power and communication system that guarantees the protection of essential instruments in a nuclear power plant under a severe accident. Both power and communication lines are established with not only conventional wired channels, but also the proposed wireless channels for emergency reserve. An inductive power transfer system is selected due to its robust power transfer characteristics under high temperature, high pressure, and highly humid environments with a large amount of scattered debris after a severe accident. A thermal insulation box and a glass-fiber reinforced plastic box are proposed to protect the essential instruments, including vulnerable electronic circuits, from extremely high temperatures of up to $627^{\circ}C$ and pressure of up to 5 bar. The proposed wireless power and communication system is experimentally verified by an inductive power transfer system prototype having a dipole coil structure and prototype Zigbee modules over a 7-m distance, where both the thermal insulation box and the glass-fiber reinforced plastic box are fabricated and tested using a high-temperature chamber. Moreover, an experiment on the effects of a high radiation environment on various electronic devices is conducted based on the radiation test having a maximum accumulated dose of 27 Mrad.

THE EFFECT OF SURFACE ROUGHNESS OF CSI(TL) MICRO-COLUMNS ON THE RESOLUTION OF THE X-RAY IMAGE; OPTICAL SIMULATION STUDY

  • Kim, Hyun-Ki;Bae, Jun-Hyung;Cha, Bo-Kyung;Jeon, Ho-Sang;Kim, Jong-Yul;Kim, Chan-Kyu;Cho, Gyu-Seong
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.25-30
    • /
    • 2009
  • Micro-columnar CsI(Tl) is the most popular scintillator material which is used for many indirect digital X-ray imaging detectors. The light scattering at the surface of micro-columnar CsI(Tl) scintillator was studied to find the correlation between the surface roughness and the resultant image resolution of indirect X-ray imaging detectors. Using a commercially available optical simulation program, Light Tools, MTF (Modulation Transfer Function) curves of the CsI(Tl) film thermally evaporated on glass substrate with different thickness were calculated and compared with the experimental estimation of MTF values by the edge X-ray image method and CCD camera. It was found that the standard deviation value of Gaussian scattering model which is determined by the surface roughness of micro-columns could certainly change the MTF value of image sensors. This model and calculation methodology will be beneficial to estimate the overall performance of indirect X-ray imaging system with CsI(Tl) scintillator film for optimum design depending on its application.

A Study on the Fire Spread between Office Room and Atrium in the Atrium Building (아트륨 빌딩에서의 사무실과 아트륨간의 화재확산에 관한 연구)

  • Lee, Su-Kyung;Kim, Jong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.78-83
    • /
    • 2000
  • Generally, There is to install fire resist shutter or to compart between the office room and the atrium in the atrium buildings in Korea. But, Glass wall that is installed sprinkler which purpose to protect it from fire, is already installed between the office room and the atrium in the advanced nations. We study this problem as follow; We made the fire scenario, and analyze each scenario using FASTLite is fire modeling software and BREAK1 is to predict the window breakage time in the compartment fire. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF

Evaluation of the Photon Transmission Efficiency of Light Guides Used in Scintillation Detectors Using LightTools Code

  • Park, HyeMin;Joo, Koan Sik;Kim, Jeong Ho;Kim, Dong Sung;Park, Ki Hyun;Park, Chan Jong;Han, Woo Jun
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.282-285
    • /
    • 2016
  • Background: To optimize the photon transmission efficiency of light guides used in scintillation detectors, LightTools code, which can construct and track light, was used to analyze photon transmission effectiveness with respect to light guides thickness. Materials and Methods: This analysis was carried out using the commercial light guide, N-BK 7 Optical Glass by SCHOTT, as a model for this study. The luminous exitance characteristic of the LYSO scintillator was used to analyze the photon transmission effectiveness according to the thickness of the light guide. Results and Discussion: The results of the simulations showed the effectiveness of the photon transmission according to the thickness of the light guide, which was found to be distributed from 13.38% to 33.57%. In addition, the photon transmission efficiency was found to be the highest for light guides of 4 mm of thickness and a receiving angle of $49^{\circ}$. Conclusion: Through such simulations, it is confirmed that photon transmission efficiency depends on light guide thickness and subsequent changes in the internal angle of reflection. The aim is to produce an actual light guide based on these results and to evaluate its performance.

A Proposal on Evaluation Method of Neutron Absorption Performance to Substitute Conventional Neutron Attenuation Test

  • Kim, Jae Hyun;Kim, Song Hyun;Shin, Chang Ho;Choe, Jung Hun;Cho, In-Hak;Park, Hwan Seo;Park, Hyun Seo;Kim, Jung Ho;Kim, Yoon Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.384-388
    • /
    • 2016
  • Background: For a verification of newly-developed neutron absorbers, one of guidelines on the qualification and acceptance of neutron absorbers is the neutron attenuation test. However, this approach can cause a problem for the qualifications that it cannot distinguish how the neutron attenuates from materials. Materials and Methods: In this study, an estimation method of neutron absorption performances for materials is proposed to detect both direct penetration and back-scattering neutrons. For the verification of the proposed method, MCNP simulations with the experimental system designed in this study were pursued using the polyethylene, iron, normal glass and the vitrified form. Results and Discussion: The results show that it can easily test neutron absorption ability using single absorber model. Also, from simulation results of single absorber and double absorbers model, it is verified that the proposed method can evaluate not only the direct thermal neutrons passing through materials, but also the scattered neutrons reflected to the materials. Therefore, the neutron absorption performances can be accurately estimated using the proposed method comparing with the conventional neutron attenuation test. Conclusion: It is expected that the proposed method can contribute to increase the reliability of the performance of neutron absorbers.

Experimental examination on physical and radiation shielding features of boro-silicate glasses doped with varying amounts of BaO

  • M.I. Sayyed;Abdelmoneim Saleh;Anjan Kumar;Fatma Elzahraa Mansour
    • Nuclear Engineering and Technology
    • /
    • v.56 no.8
    • /
    • pp.3378-3384
    • /
    • 2024
  • Investigations were conducted on the addition of barium's impact on the radiation shielding and physical attributes of five different glasses, designated S1-S5, with varying BaO contents. Using two point sources namely Co60 and Cs137 along with a scintillation detector [NaI(TL)], experimental measurements were made of the shielding parameters of γ-rays, namely the effective atomic number (Zeff), electron density (Nel), half-value layer (HVL), linear attenuation coefficient (μ), mass attenuation coefficient (μm), mean free path (λ), and radiation protection effectiveness at the energies of 0.664, 1.177, and 1.334 MeV, and comparisons made with recently considered glasses as well as frequently employed materials for γ-ray shielding. The results show that the examined glasses' physical and radiation shielding qualities are improved by the addition of BaO. The μ values increased from 0.245 to 0.275 cm-1 (0.662 MeV), from 0.174 to 0.198 cm-1 (1.173 MeV), and from 0.161 to 0.189 (1.332 MeV). The observed values of HVL decreased from 2.83, 3.98, and 4.3 cm to 2.5, 3.5, and 3.62 cm at 0.662, 1.173, and 1.332 MeV, respectively, for the samples S1 and S5. In addition, the S5 glass sample was determined to have the best protection against photon among all the samples that were evaluated, as well as against recently considered glasses and those materials often utilized for gamma-ray shielding purposes.

Comparative analysis of TiO2, Fe2O3, CaO and CuO in borate based glasses for gamma ray shielding

  • Heba Jamal Alasali;U. Rilwan;K.A. Mahmoud;Taha A. Hanafy;M.I. Sayyed
    • Nuclear Engineering and Technology
    • /
    • v.56 no.10
    • /
    • pp.4050-4055
    • /
    • 2024
  • This research intends to utilize melt-quenching technique in order to examine the radiation shielding capability of 10 % Mo, 10 % Na2O, 20 % PbO, and 60 % B2O3 glass system, with varying CaO, TiO2, CuO, Fe2O3 or Mo. XCOM and MCNP simulations were utilized to analyze the radiation shielding properties of the fabricated glasses. The results revealed CuO having the superior MAC of 49.91 cm2/g, then Fe2O3 with 49.24 cm2/g, followed by CaO with 49.10 cm2/g, and TiO2 with 48.49 cm2/g as the least. CuO and Fe2O3 were confirmed to have least HVL compared to CaO and TiO2. The value of the lead equivalent thickness showed fluctuation against the gamma energy, where it raisess within the photoelectric region and falls after the photoelectric region. The data reveal that, the lead equivalent thickness at 0.1 MeV were 7.88 cm, 7.86 cm, 7.81 cm and 7.80 cm for TiO2, Fe2O3, CaO, and CuO in the same order, respectively. The transmission factor (TF) raises as the gamma energy raises, having TiO2 as the highest with 76.068 %, while the radiation protection efficiency dropped as the energy raises.

REMINERALIZATION EFFECT OF FUJI VII GLASS IONOMER CEMENT (Fuji VII 글래스 아이오노머 시멘트의 재광화 효과)

  • Kim, Young-Jin;Lee, Ju-Hyun;Seo, Hyun-Woo;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.653-660
    • /
    • 2006
  • Fuji VII is a glass-ionomer cement specially targeted for early protection in erupting first and second molars. Properties of Fuji VII such as very high level of fluoride release, low viscosity and no need to preliminarily etch the substrate would be useful to erupting molars with primary pit and fissure caries or hypoplastic area for preventive goal or remineralization. The purpose of this study were to evaluate remineralization of Fuji VII glass ionomer cement and to compare with one of other restorative materials such as conventional glass ionomer cement, resin-modified glass ionomer cement, compomer and composite resin. Forty-two extracted human molars were used for this study. All teeth were immersed in demineralizing solution for 48 hours after Class V cavity preparation was made on sound proximal surface. The teeth were randomly divided into six groups and restored with Fuji VII, Fuji II, Fuji II LC improved, F2000, $Filtek^{TM}$ Z250 and control group was unrestored. The middle area with $130{\pm}20{\mu}m$ thickness was separated from specimen using microtome and demineralized area was photographed under polarized microscope. Separated area was relocated to specimen and stored in artificial saliva, After four weeks, changes of demineralized area were observed and compared to them restorated immediately. The results from the this study can be summarized as follows ; 1. Fuji VII, Fuji II, Fuji II LC improved have more prominent remineralization effect than F2000, $Filtek^{TM}$ Z250, control group. 2. No significant differences in remineralization effect are seen between Fuji VII and Fuji II, Fuji II LC improved.

  • PDF

Minimization of Friction and Wear Damage of Marine Structures by Using the Advanced Anti-corrosive Composite Materials (첨단복합방식재를 이용한 각종 선박구조물의 마찰마모손상의 최소화)

  • 김윤해;김진우
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.5 no.2
    • /
    • pp.15-26
    • /
    • 1999
  • The marine structures with sea water cooling system always expose to the oceanic atmosphere. Therefore, the protection of the equipments is very important. To investigate the effectiveness of advanced composite materials for the application in offshore environments, the tensile test, hardness test, undercutting property test, permeance test and the friction and wear test were carried out by using various applicable coating materials. The main results obtained can be summarized as follows; 1. The micro-hardness of the Archcoat 502B showed the highest value. 2. The coefficient of friction of the Rigspray coating at the speed of 2.21m/sec showed the lowest value, and that of the Archcoat 502B coating at 1.08m/sec and 0.18m/sec indicated the lowest values. 3. The wear mass at the speed of 0.18m/sec and 1.08m/sec in dry condition showed the smallest values. 4. The Archcoat 502B coating is fitted to the dynamic instruments in the range of low speed and middle speed. Rigspray coating is fitted to the dynamic instruments in the range of high speed. 5. The wear mass of five kinds of coating materials at the range of low speed was very small, and those of the Archcoat S02B, Archcoat 402B and Rigspray coating at high speed range were quitely smaller than those of the Modified Epoxy and Tar Epoxy.

  • PDF

Present State and Prospect on Reutilization of Metal - Bearing Solid Wastes in China

  • Chai, Liyuan;Chen, Weiliang;Min, Xiaobo;He, Dewen;Zhang, Chuanfu
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.183-187
    • /
    • 2001
  • Present states on reutilization of metal-bearing solid wastes in China including metal-containing gangue, red mud, nonferrous metallurgical slag or residue, arsenical slag, steel - iron slag, waste batteries, were described in detail. The wastes pile up at a large quantity, resulting in seriously potential harm to environment. Most of these wastes, however, contain valuable metals, which are regarded as important secondary resources for extracting metals. Waste slag and batteries with a high grade of metals are treated by a hydro-based and / or pyre-based method for extracting valuable metals. While gangue and waste slag with a low grade are as a raw material in architecture field. In the future, a novel technology, such as high-grads magnetization separation technique and biological technique, will be designed to treat these wastes for protecting environment and recycling valuable components. These wastes, furthermore, are synthetically reutilized to produce various architectural materials, including glass and ceramics.

  • PDF