소방서건물의 신재생에너지시스템 최적화에 관한 연구 (A Study on the Optimization of a Renewable Energy System in Fire Station Buildings)

  • 이용호;홍준호;조영흠;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제33권1호
    • /
    • pp.79-88
    • /
    • 2013
  • This study set out to evaluate the economy, environmentality, and complexity (economy+environmentality) of fire station buildings of public service facilities and propose ways to apply the optimization of renewable energy system to fire station buildings. As for economy according to life cycle costs, economy increased when the application percentage of the geothermal and solar heat system increased over the three renewable energy system types (geothermal, solar heat, and solar photovoltaic). On the other hand, economy decreased when the application percentage of the solar photovoltaic system increased. As for environmentality according to tons of carbon dioxide, environmentality decreased when the application percentage of the geothermal and solar heat system increased. Environmentality increased when the application percentage of the solar photovoltaic system increased. As for complexity (economy+environmentality) according to the weighted coefficient method, complexity increased when the application percentage of the geothermal system increased. It was highest at the combination of the solar heat system (20%) and geothermal system (80%). On the other hand, complexity decreased when the application percentage of the solar photovoltaic system increased. It was lowest at the combination of the solar photovoltaic system (80%) and geothermal system (20%).

공동주택용 하이브리드 지열 냉난방 시스템의 적용추진 전략 (A method for Application of Hybrid Geothermal Cooling-Heating System in Multi Family Apartment)

  • 박용부;박종배;김길태
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1447-1454
    • /
    • 2009
  • Currently, geothermal heat pump systems are being installed in new official and commercial building, welfare facilities, and school but there are a few cases for the housing heat sink in Korea. The reason is that there are no progressive taxes for the household electrical use, no actual output for the application of geothermal technology, high initial investment. For the overall use in multi family apartment such as the Green Home etc, technology development and building of the relevant research team need to be done through preliminary study. Core subjects for overall use include cooling heating load estimation for the multi family apartment, economical efficiency of the geothermal cooling and heating system, design and construction technology of the geothermal cooling and heating system for the multi family apartment, commercialization plan, and state of the art analysis. Selection of the detailed subjects with respect to core subject, driving schedule and commercialization plan, driving system, presentation of the utilization plan.

  • PDF

단독주택의 지열시스템 적용 가능성에 대한 기초연구 (Basic Study on Geothermal System Application Possibility of a Detached House)

  • 신희일;장태익
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.794-800
    • /
    • 2008
  • Due to high oil prices and global warming problems, researching an alternative energy source and decreasing the energy usage will be the key in the future. Unlike other alternative energy sources, geothermal energy is less dependent on the surrounding environment. Geothermal energy is the ideal energy source for buildings due to the simple and space saving installation. The system is semi permanent once it is installed and this will help reduce the energy usage in controlling the climate in buildings. Geothermal energy does not emit carbon dioxide and other gases that are harmful to the environment. Therefore geothermal energy will be the key in solving high oil prices and a decrease in fossil fuels by applying the geothermal energy system to detached house to counter future energy crisis.

  • PDF

고심도 지중열전도도에 의한 지열 응용의 효율성 (Efficiency of Geothermal Energy Generation Assessed from Measurements of Deep Depth Geothermal Conductivity)

  • 조희남;이달희;정교철
    • 지질공학
    • /
    • 제22권2호
    • /
    • pp.233-241
    • /
    • 2012
  • 이 연구의 목적은 현장의 지중열교환기에서 조건별 지중열전도도, 유속, 유량 및 파이프관내 압력을 측정하고, 이들 시험자료들을 분석하여 지열응용의 효율성을 평가하는데 있다. 규정에 따라 현장측정 장비를 설치한 후 3가지 다른 경우에서 각각 열전도도를 얻었다. 2차와 3차 경우의 결과를 바탕으로, 동일한 암반 지중하에서 다른 깊이(506 m, 151 m), 다른 파이프관경(65 mm, 30 mm)별 얻어진 열전도도는 각각 k=2.9, k=2.8로 크게 차이가 나지 않았다. 4차 경우는 2차 경우와 같은 조건의 심도 지중하에서도 이중관일 경우에는 열전도도가 k=2.5로 크게 차이 나지 않았다. 이러한 결과는 지열이용 시, 같은 지질일 경우 깊이가 중요한 변수가 될 수 있음을 보여 주고 있다. 또한 이 시험에서 얻은 물의 유속과 물의 유량 측정값 및 열전도도를 시뮬레이션 분석한 결과, 지열시스템의 운영 시 심도 506 m 지열공 한개가 심도 151 m 지열공 3개 운영보다 더 경제적임이 확인되었다. 비슷한 지중열전도도 환경에서 0.8 m/sec로 같은 유속일 경우 약 4배의 유량($9.3{\sim}9.8m^3/d$, $2.3{\sim}2.5m^3/d$)의 차이를 보였다. 특히 대도시 건물 밀집형 지대 또는 지가가 비싸서 간접비가 많이 발생하는 대도시 지역에서는 훨씬 더 경제적일 것으로 판단된다.

지열 Hybrid System 개발을 통한 대형 공동구조물 지열에너지 적용성 평가 (Application of the Geothermal Hybrid System for Huge Size Common Structures with Heating & Cooling System)

  • 박시삼;나상민;박종헌;이건중;김태원;김승엽
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.588-591
    • /
    • 2009
  • Ground source heat pump system; GSHPs is close to most practical use for early stage investment cost and energy efficiency in new renewable energies, and currently considered utilizing to the heat and cooling system of a building. Particularly, the case to utilize 'Standing Column well heat source gathering method' in the open standards process to have the excellent capability of gathering geothermal source is increased. But the research for the optimal design technology and the assessment of a pollution level of the ground to utilize a single well for gathering geothermal is insignificant and the design is insufficient. The heating and cooling system and the equipment to utilize a large size residential development to have over 1000 households have not developed yet. Therefore, our company developed 'geothermal hybrid system' which can construct the heat and cooling system using geothermal energy for a large size residential development of over 1000 households and conducted the evaluation of economic feasibility. Moreover we developed automatic equipment for gathering geothermal source and PLC (Programmable logic controller) to have optimal efficiency and FCU (fan coil unit) considering the floors of large size apartments.

  • PDF

국내의 지열에너지 열펌프 시스템 활용현황과 활성화 방안 (Application and Revitalization Method of Domestic Geothermal Heat Pump System)

  • 박혜리;고영호;김민태;박종일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.922-927
    • /
    • 2009
  • Due to the law of use of sustainable alternative energy recently legislated, many public institutions are ordered to use renewable energy. So it gets people's eyes on Geothermal energy system among other suggested renewable energy. Since there is hardly existence of a volcanic region, Geothermal heat pump system is generally used most in Korea. However, the important technology and materials are not localized and further, with only our technical skills it is arduous to popularize and develop Geothermal energy because of lack of revitalization related to the law and the regime for locally suitable Data-base. Moreover, an access of renewable energy is too much hard because of people's low interests about Geothermal energy. But fortunately, the well-studied about Geothermal heat system started to be adopted in many other provinces. Therefore, we study this with intend to popularize and develop Geothermal energy.

  • PDF

텍스타일형 지중열교환기의 터널에서의 적용 (Application textile-type geothermal heat exchanger for tunnel)

  • 이철호;이강자;길후정;정재형;최항석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.604-607
    • /
    • 2009
  • The geothermal energy have been developed as the pro-environmental and the substantial long-term energy. Recently energy foundations and other thermo-active ground structures have been developed to enhance the use of geothermal energy. In this research, a tunnel wall is focused as a source of geothermal energy. If the tunnel wall can be used for geothermal source, it can provide relatively lower cost because it is not necessary to make a deep borehole like in case of closed-loop vertical ground heat exchanger. For analyzing efficiency of heat exchanger in tunnel, laboratory tests and the numerical analyses are performed.

  • PDF

수평형 지중 열교환기의 출구온도 예측을 위한 EnergyPlus 적용 타당성에 관한 연구 (The Study on EnergyPlus Simulation Application Feasibility for Exit Air Temperature Prediction through Horizontal Geothermal Heat Exchanger)

  • 황용호;조성우
    • 설비공학논문집
    • /
    • 제28권4호
    • /
    • pp.131-136
    • /
    • 2016
  • Horizontal geothermal heat exchanger is affected by various factors such as pipe length, soil temperature, and outdoor environment. Simulation program is convenient for responding to various factors. The objective of this study was to determine the feasibility of using EnergyPlus to predict exit air temperature through horizontal geothermal heat exchanger in domestic. The correlation coefficient between EnergyPlus results and experimental results was 0.825. The correlation coefficient between EnergyPlus results and mathematical results was 0.722, indicating "The two values can based on Lousi on values can be Our results indicate that it is possible to use EnergyPlus to predict exit air temperature through horizontal geothermal heat exchanger.

공동주택용 지열냉난방 적용성 검토 연구 (A Study on Application of Geothermal Heatpump System for Apartments)

  • 백성권;안형준;이동철;임성균
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.574-578
    • /
    • 2009
  • Residential is the biggest market for geothermal heatpump systems in the world. However It could not be considered as a big market in Korea. Serious problems are hidden. In this paper, I will discuss about with other problems that we must solve.

  • PDF

석모도 지열수 개발을 위한 자기지전류탐사의 적용 (Application of magnetotelluric survey for development of deep geothermal water at Seokmo Island, Korea)

  • 이태종;송윤호;박덕원
    • 한국지열·수열에너지학회논문집
    • /
    • 제4권1호
    • /
    • pp.1-10
    • /
    • 2008
  • A magnetotelluric survey and geological survey have been performed to delineate deeply extended fracture systems at the geothermal field in Seokmo Island, Inchon, Korea. One borehole(BH-1) succeed to meet a large fracture system at the depth of 750 m where approximately $72^{\circ}C$ geothermal water is overflowing, while the other borehole(BH-2), which is about 200 m eastward from BH-1, failed to develop enough geothermal water even at the depth of 1,200m. Though there have been so many electric noise sources around the survey region, good quality of MT data above 1 Hz could be obtained with careful installation, remote reference processing. Inversion of MT data for two lines roughly perpendicular to the two major lineaments respectively show that the two lineaments are related to the fracture systems that are extended at least down to 1.5 km depth and inclined eastwards. From the interpretation, additional drilling for BH-2 is recommended and finally meet the fracture systems at the depth of 1,280 m and resulted in overflow of large amount of geothermal water of temperature $69.4^{\circ}C$ from BH-2.

  • PDF