• Title/Summary/Keyword: geotechnical design

Search Result 1,815, Processing Time 0.02 seconds

Investigation of Seismic Response for Deep Temporary Excavation Retaining Wall Using Dynamic Centrifuge Test (동적원심모형실험을 통한 대심도 가설 흙막이 벽체 지진 시 거동 연구)

  • Yun, Jong Seok;Han, Jin-Tae;Kim, Jong-Kwan;Kim, Dongchan;Kim, Dookie;Choo, Yun Wook
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.11
    • /
    • pp.119-135
    • /
    • 2022
  • This paper used dynamic centrifuge tests to examine the seismic response for a deep temporary retaining wall with four input motions of 100, 1,000, and 2,400 years of return periods. The centrifuge model was designed based on an actual deep excavation design with a 50 m maximum excavation depth. The model backfill was prepared with dry silica sand at a relative density of 55%, and the retaining wall was modeled as a 24.8 m height diaphragm wall supported by struts. Acceleration response was amplified at the backfill surface, top of the wall, and near bedrock. However, in the middle of the model, input motion was de-amplified. The member forces of the wall and strut induced by the seismic load, which excited, were compared with the member force at rest condition. The wall's maximum negative and positive moments were increased to 36% and 10% compared to the maximum moment at rest. The maximum axial force increases to 70% of the at rest axial force on the bottom strut. The equivalent static analysis using Mononobe-Okabe (M-O) and Seed-Whitman (S-W) seismic earth pressures were compared to the centrifuge results. Considering the bending moment, the analysis results with the M-O theory underestimates but that with the S-W theory overestimates.

A Study of Soil Spring Model Considering the Seismic Load in Response Spectrum Analysis of Pile-Supported Structure (잔교식 말뚝 구조물의 응답스펙트럼해석 시 지진하중을 고려한 지반 스프링 모델 제안)

  • Yun, Jung-Won;Kim, Jongkwan;Lee, Seokhyung;Han, Jin-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.9
    • /
    • pp.5-17
    • /
    • 2022
  • Recently, several studies have been conducted on virtual fixed-point and elastic soil spring methods to simulate the soil-pile interaction in response to spectrum analysis of pile-supported structures. However, the soil spring stiffness has not been properly considered due to the seismic load magnitude, and studies on the response spectrum analysis of pile-supported structures considering this circumstance are inadequate. Therefore, in this study, the response spectrum analysis was performed considering the soil spring stiffness according to the seismic load magnitude, and the dynamic behavior of the pile-supported structure was evaluated by comparing it with existing virtual fixed-point and elastic soil spring methods. Comparing the experiment and analysis, the moment differences occurred up to 117% and 21% in the virtual fixed-point and elastic soil spring models, respectively. Moreover, when the analysis was performed using an API p-y curve considering the soil spring stiffness according to the seismic load magnitude, the moment difference between the experiment and analysis was derived at a maximum of < 4%, and it is the most accurate method to simulate the experimental model response.

An Investigation on the Long Term Durability of High-strength Shotcrete Using Field and Combined Deterioration Test (현장실험과 복합열화시험을 통한 고강도 숏크리트의 장기내구성 검토)

  • Ma, Sang-Joon;Choi, Jae-Seok;Ahn, Kyung-Chul;Kim, Sun-Myung;Kim, Dong-Min
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.10
    • /
    • pp.77-91
    • /
    • 2006
  • Domestic practices in shotcrete use have developed in many respects even now, but it still has issues about material, construction, quality standard and so on. In overseas, the construction using high strength shotcrete with $39.2{\sim}58.8 MPa$ of compressive strength is becoming common based on the shotcrete technology of high strength and durability. However, domestic shotcrete design strength is low at around 20.6 MPa of compressive strength and a long term durability is also insufficient. In this paper, field tests using high-quality additives and accelerators were performed to obtain the improvement of shotcrete strength and EFNARC standard was used to evaluate the field test results. In addition, deterioration test combined with the freezing-thawing and carbonation was also performed in order to investigate a long-term durability of high-strength shotcrete. As a result of the field test, the promotion ratio of early strength was $90{\sim}97%$ in case of using alkali-free accelerators. And the compressive strength of the shotcrete using Micro-silica fume was $45.2{\sim}55.8MPa$ and flexible strength was $5.01{\sim}6.66MPa$, so the promotion ratio of strength was $37{\sim}79%$ and $17{\sim}61%$ respectively. The promotion effect of strength by silica fine additives ratio of $7.5{\sim}10%$ for cement mass was much superior to the other cases. It was especially examined that using Micro-silica fume reduced deterioration due to mixed steel fiber and improved a long-term durability of shotcrete.

Evaluation of Non-linear FEM Tunnel Analysis by using Hoek-Brown반s Insitu Rock Model (Hoek-Brown 암반모델을 이용한 비선형 유한요소 터널해석 및 평가)

  • Lee, Bong-Yeol;Kim, Gwang-Jin;Kim, Hak-Mun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.09a
    • /
    • pp.235-246
    • /
    • 1994
  • At pre-construction design stage, most of the design data are based on the site investigation results or property estimation which often does not provide satisfactory output for the tunnel analysis. Nonlinear FEM tunnel analysis was cariied out by Hoek-Brown model which is principly semi-empirical design method based on insitu rock descriptions, rock test results as well as field measurement data. The results of the analytical methods from Hoek-Brown model and Mohr-Coulomb model are compared with the sige measurement data from two-NATM tunnel construction sites. It was found that the Hoek-Brown model can be satisfactorily adopted as a feed back analysis technique in order to examin the safety of NATM tunnel at any construction stage.

  • PDF

DESIGN AND CONSTRUCTION OF STRUTTED AND ANCHORED SHEET PILE WALLS IN SOFT CLAY

  • Broms, Bengt-B
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.09a
    • /
    • pp.1-59
    • /
    • 1994
  • The design and construction of strutted and anchored sheet pile walls in soft clay are reviewed based on experience gained mainly in Singapore during the last 10years where mainly strutted sheet pile walls diaphragm walls, and contiguous bored piles are used. It is important to consider in the design the high lateral earth pressures acting on the sheet piles below the bottom of the excavation when the depth of the excavation is large compared with the shear strength of the clay. The strut loads and the maximum bending moment in the sheet piles can in that case be much higher than indicated by a conventional analysis. Different methods to increase the stability have been investigated. With jet grouting, embankment piles and excavation under water it is possible to reduce significantly the maximum bending moment, the strut loads, and the settlements outside the excavated area as well as the heave within the excavation.

  • PDF

Design and Construction of a Large Section Tunnel for a Subway Station (지하철 대단면 터널의 설계와 시공관리 사례)

  • 문상조;장석부;정준화
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.285-292
    • /
    • 1999
  • Recent development cases of transportation utilities using tunnelling method in metropolitan sites have been increased due to the heavily complex environments and restrictions of construction works. The progress of tunnel design and construction to be supported by the tunnel analysis and measurement techniques using computers have increased adoptions of large section tunnels. In this paper, many factors to be considered in designing large section tunnels are discussed and the case of the construction of the subway station tunnel which is recently completed is introduced. This tunnel has a width of 24 m, a height of 16 m, and a excavation section area of 366 ㎡.

  • PDF

Evaluation of Durability and Long-term Design Tensile Strength of Flexible Geogrids (연성 지오그리드의 내구성 및 장기설계인장강도 평가)

  • 조삼덕;김진만;안주환;전한용;조성호
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.11c
    • /
    • pp.21-38
    • /
    • 1999
  • Engineering properties of most polymers used in geosynthetics such as geogrid can be degraded by the chemical reaction (e.g., oxidization, ultraviolet rays, hydrolysis etc.), chemical and mechanical load, microorganism, and so on. In addition, polymer can be damaged by the compaction during construction, and the characteristic of tensile strength of polymer can be changed by the long-term creep effect. In this study, engineering properties of flexible geogrids which are manufactured by weaving/knitting the high-tenacity polymers such as polyester formed in a very open, grid-like configuration, coated with any one of a number of materials (e.g., PVC, latex, etc.), are investigated. Through the analysis of test results, the durability and the long-term design tensile strength of flexible geogrids are evaluated.

  • PDF

Stability Analysis and Design of Slope Reinforcing Method Using Anchored or Waste Tyre Wall (앵커 또는 폐타이어 벽체를 이용한 사면보강공법의 안정해석 및 설계)

  • Kim, Hong-Taek;Gang, In-Gyu;Lee, Je-U
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1993.10a
    • /
    • pp.69-72
    • /
    • 1993
  • In this paper, relatively new slope reinforcing system using an anchored wall is presented. For practical design purposes a method of external and internal stability analyses of an anchored wall installed at the toe of the original unstable or quasi-stable slope is developed. And also Murray's full-scale test results are compared with the passive resistance of an anchor predicted by the present study. Finally a design example of reinforced slope using an anchored wall is analyzed, and the safety as well as benefits is compared with a method of changing the geometry of the original unstable slope.

  • PDF

Design method and factors of offshore wind power system foundation (해상풍력발전 시스템 기초의 설계방법 및 설계인자)

  • Song, Won-June;Kyung, Doo-Hyun;Lee, Jun-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.646-657
    • /
    • 2010
  • Offshore wind power is one of the largest-scale solutions for a nuclear- and pollution-free electricity supply in the future. Recently, the research for offshore wind power has started in Korea. However, there has been little effort specifically made for the exploration and evaluation of mechanical characteristics for offshore underwater soil deposits. In offshore wind power system, this is important as consistent and safe maintenance of structural functionality of the system is key for the wind power system to be successfully implemented. In this study, case examples from foreign offshore wind power sites are selected and analyzed. And design methods and factors of offshore wind power system foundation are investigated.

  • PDF

A Study on the Resonable Design of Eco-Metal Reinforced Retaining Wall (Eco-Metal 보강토 옹벽의 합리적 설계에 관한 연구)

  • Yoon, Jun-Yeong;Noh, Si-Won;Lee, Yeong-Seang;Lee, Soon-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.772-781
    • /
    • 2010
  • In this study, a revegetation reinforced earth retaining wall to strengthen the strength than construction and make up for the weakness; eco-friendly part, of the existing facilities is new construction method. The special attention is that Eco-Metal reinforced retaining wall is not use concret. Before test construction on the scene, the stability of Eco-Metal reinforced retaining wall was checked by an experiment with a model and numerical analysis. The result of an experiment with a model was that the loaded tensile stress 40.2KN/m was more than long-term design tensile strength 29.4KN/m at Geogrid and a safety factor of numerical analysis was 1.14.

  • PDF