• Title/Summary/Keyword: generation gaps

Search Result 64, Processing Time 0.024 seconds

Effective Ozone Generation from Hole Gaps in Water (공전극(孔電極)을 사용(使用)한 효과적(效果的)인 수중(水中) 오존발생(發生))

  • Moon, Jae-Duk;Kim, Jin-Gyu;Kim, Kee-Ung;Choi, Jung-Uk;Kim, Chang-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1625-1627
    • /
    • 1994
  • A potential to effective ozone generation for 4 kinds of gap, a hole-to-plate gap, a hole-to-hole gap, a hole-to-rod gap and a plate-to-plate gap in tap water has been investigated. It is found that the hole gaps indicated higher ozone generation compared to that of the plate-to-plate gap. As a result, the hole gaps could be an effective means to generate ozone in water by utilizing both of one generation mechanisms of the discharge and the electrolysis.

  • PDF

Ozone Generation Characteristics by Surface-Silent Discharge According to the Length of Coaxial Electrode (동축형 전극길이 변화시의 연면무성방전에 의한 오존발생특성(I))

  • Jo, Guk-Hui;Kim, Yeong-Bae;Seo, Gil-Su;Lee, Hyeong-Ho;Lee, Sang-Geun;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.12
    • /
    • pp.791-797
    • /
    • 1999
  • Recently the ozone generation system is well used for cleaning the contaminated water by using the strong oxidization effects of ozone. In this paper the concentration, yield and generation quantity of the ozone by the Surface-Silent Discharge According to the Length of Coaxial Electrode is described. The electrodes composed of 3 electrodes-2 gaps are coaxial type and the ozone generation tube were designed and fabricated from the point of view of the energy efficiency, stability and easy control. To investigate the ozone generation dependency on electrode length, a few discharge tubes with different lengths were fabricated. The experimental equipments were provided with cooling system and dehumidifier for the many testing conditions. The main results show that the concentration, yield and generation quantity of ozone are improved by decreasing gas temperatures and increasing electrode lengths.

  • PDF

Interaction of Multi Current Power Generation Blade (멀티 해류발전 블래이드 간섭 연구)

  • Jo, Chul-Hee;Park, Kwan-Kyu;Cho, Won-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.47-54
    • /
    • 2006
  • The current power generation is very suitable renewable energy for the application to Korean western and south coastal regions where characterized as having high current speed. Being different from tidal power generation that needs tremendous dam structure to preserve water, the current power generation utilizes the ocean current flow without damaging to estuary area and its environment. There are still many areas to understand the characteristics of current power generation for the actual field installation. As designing muti module with several rotors, the interaction between rotors will occur that would affect the efficiency and RPM of each rotor. In this study, the interactions caused by gaps between rotors in multi module are studied.

An Interpretation of the Gaps between 'Fact' and 'Oral Materials' in Political Elite Oral History ('사실'과 '구술자료'의 간극에 대한 하나의 해석 정치엘리트 구술연구를 중심으로)

  • Jo, Young-Jae
    • The Korean Journal of Archival Studies
    • /
    • no.43
    • /
    • pp.43-70
    • /
    • 2015
  • The value and validity of elite oral materials have been questioned because of their gaps with 'fact'. The purpose of this article is to analyze these gaps and to propose some solutions that can reduce the gaps. According to the analysis of this article, there are three types of the gaps that qualitatively differ from each other. The first type of the gaps is produced in the process of generation of memory. This type is made because informants cognize and memorize the facts that exist outside themselves. Selective cognition, selective memory and individual experience come under this category. The second type is produced in the process of preserving the memory. Forgetting and memory transformation are main examples of this type. The third type is produced in the process of the interviews with the informants. False statements or lies fall into this category. The main conclusions are as follows. 1) all gaps in oral materials are not necessarily negative. It is because Some of these gaps- the first and the second type- are not only parts of the real world but also very useful for interpreting the world. 2) The third type of the gaps are very harmful and it is need to be eradicated or reduced. For this, this article proposes some solutions.

The effects of visual and auditory information as A tool of emotional value assessment (감성 가치 평가를 위한 시각적, 청각적 매체의 효용)

  • Kim Myung-Suk;Lee Eun-Chang
    • Journal of Science of Art and Design
    • /
    • v.1
    • /
    • pp.95-123
    • /
    • 1999
  • The goal of this research is a visual and auditory tool development enabling designers to have the same emotional value with users in the process of user centered design. Through the research, we intend to show the aid measure for making cognitive gaps narrow between users and designer in the process of transforming and understanding the emotional needs as a verbal image. because In the business practice of design, most of tools and techniques for assessment and analysis of emotional needs are those used usually in the marketing fields. So the information generated and transformed from users to designers have a form of physical words. When the designer's understanding of the emotional needs is considered as a product mediated communication process, the morphologic and cognitive information gaps become obvious. This difference could be a false basis in designing with emotional user needs. So the alternative needs assessment sub-tools of visual and auditory information form was embodied mainly for designer's cognitive gaps and inter-cultural emotional needs assessment. As the method of embodiment, Firstly, adjectives related to emotion were classified in their cognitive dimension. Secondly, visual and auditory data were extracted, and then the relativity verified. Finally, the practicality and effectiveness were tested through the database generation. In view of the results so far achieved, 1. We could find being of the big information cognitive gaps in the verbal assessment of emotional needs between designers and users. 2. With the visual and auditory assessment tool, we could make the big cognitive gaps narrower than we expected. 3. Also, we could find the chance that the fidelity, recognition, and friendliness of design for emotional user needs would become better.

  • PDF

Trial Manufacture and Characteristics of a Multi-discharge Type ozonizer(I) (다중방전형 오존발생기의 試作 및 特性(I))

  • Song, Hyeon-Jik;Lee, Gwang-Sik;Park, Won-Ju;Lee, Dong-Heon;Kim, Geum-Yeong;Kim, Lee-Guk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.7
    • /
    • pp.533-541
    • /
    • 1999
  • Multi-discharge type ozonizer(MDO) using superposed silent discharge has been designed and manufactured. It consists of three electrodes( central electrode, internal electrode, and external electrode ) and double gaps( gap between central electrode and internal electrode, gap between internal electrode and external electrode ). Therefore, ozone is generated by superposing silent discharges generated between the gaps respectively. And the MDO consists of three types of superposed discharge ozonizers according to voltage appling method for each electrode ; A.C. high voltages are applied two of three electrodes with phase difference of 180[˚], the other electrode is a ground. This paper describes that discharge and ozone generation characteristics of MDO which comprising central electrode and internal electrode applied A.C. high voltages with phase difference of 180[˚] respectively, and the grounded external electrode. As a result, the maximum ozone concentration, generation, and yield can be obtained 10208[ppm], 6.4[g/h], and 280[g/kwh] respectively.

  • PDF

Design of ultraprecision hi-directional actuator for nm using a permanent magnet and electromagnet (영구 자석과 전자석의 상호작용을 이용한 초정밀 양방향 구동기 설계)

  • Kim Ki-Hyun;Gweon Dae-Gab
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.9 s.174
    • /
    • pp.147-154
    • /
    • 2005
  • A precision hi-directional actuator for a high precision leveling system with $Z{\Theta}_x{\Theta}_y$ motions is proposed and designed in this paper. The actuator is composed of a force generation structure, a guide mechanism, and a symmetric structure. At first, its driving force is generated by a change of flux in air gaps by permanent and changeable flux. The permanent flux is generated by a permanent magnet. The changeable flux is created by variable current flowing through coil. The combination of permanent and changeable flux makes various flux densities in air gaps between moving part and fixed yokes. And then, the difference between flux densities in lower and upper gaps creates forces fur the $bi-direction({\pm}z)$ motion. The guide mechanism of this actuator is composed of two circular plates and one shaft. Reducing motions generated by forces except z-motion, these circular plates endow the actuator with high stiffness for fast settling time. And the function of the shaft is to transfer motion to an object. At last, total body has a symmetric structure to be stable on thermal error. The actuator is designed by MAXWELL 2D and ProMECHANICA. The designed actuator is evaluated by 8nm laser doppler vibrometer, dynamic signal analyzer, and simple PID controller.

A Field Investigation of Defect Type for Development of Maintenance Manual of Han-ok (한옥 유지관리매뉴얼 개발을 위한 결함 유형 현장 조사)

  • Lee, Jong Shin;Choi, Gwang Sik;Yang, Jeong Moo
    • Journal of the Korea Furniture Society
    • /
    • v.24 no.3
    • /
    • pp.302-308
    • /
    • 2013
  • To collection of field data for development of maintenance manual of Han-ok, we investigated defects which occurred in members of Han-ok by field investigation. The noticeable defects were wood cracks, gaps that developed between wood pillar and wall or wood window frame and tenon joints. The most common biological defect was blue stain which was created in log. The mold generation was observed on exterior wood and wall which get wet by precipitation. The gaps between members of Han-ok pointed out as defect that is urgently improved by residents of Han-ok. The reason is mainly due to poor of insulation in winter by bad confidentiality. The maintenance work of defect such as gap was conducted personally. As a result, the repair parts were ugly for unfamiliar repair work.

  • PDF

Characteristics of a Superposed Discharge Type Ozonizer(III) (중첩방전형 오존방생기의 특성(III))

  • Song, Hyun-Jig;Lee, Kwang-Sik;Lee, Dong-In;Kim, Gi-Chae;Lee, Dong-Heon;Kim, Geum-Young;Lee, Chun-Ha;Jeun, Young-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1815-1817
    • /
    • 1998
  • In this paper, a superposed discharge type ozonizer(IESDO) has been designed and manufactured. IESDO is equipped with three electrodes(central, internal and external electrodes), and it is composed of two gaps. Ozone is generated by overlapping silent discharge, which is respectively came from two gaps. This paper describes the following characteristics : (1) The characteristics of discharge with variation of output voltage of AC H.V source, quantity of supplied gas and discharge voltage (2) the characteristics of ozone generation with variation of quantity of supplied gas, discharge power, operating number of IESDO.

  • PDF

Trial Manufacture of Ozone Generator Using Silent Discharge Type and Improvement Properties of the Water Quality in the Lake (무성방전형 오존발생장치 제작 및 수질 개선 특성)

  • 임헌찬;김진규;우성훈
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.50 no.3
    • /
    • pp.125-129
    • /
    • 2001
  • ln this paper, a ozone generator using superimposition of silent discharge has been designed and manufactured. This type ozone generator is equipped with three electrodes and two gaps. Ozone is generated by superimposition of silent discharge, which is respectively come from two gaps. The maximum values of ozone concentration, ozone generation flow and ozone energy field were obtained 4,750[ppm], 2.37[g/h], 102.3[g/kWh]. Also, the result of reaction of 1,8921ppm] ozone and the sampling water from the lake, the water quality was improved from IV grade to In grade, and obtained 100[%] sterilization rate of Escherichia coli within 5.0(min).

  • PDF