• 제목/요약/키워드: generated power

검색결과 3,478건 처리시간 0.031초

Power Frequency Magnetic Field Reduction Method for Residents in the Vicinity of Overhead Transmission Lines Using Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Lee, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.829-835
    • /
    • 2011
  • A power frequency magnetic field reduction method using passive loop is presented. This method can be used to reduce magnetic fields generated within the restricted area near transmission lines by alternating current overhead transmission lines. A reduction algorithm is described and related equations for magnetic field reduction are explained. The proposed power frequency magnetic field reduction method is applied to a scaled-down transmission line model. The lateral distribution of reduction ratio between magnetic fields before and after passive loop installation is calculated to evaluate magnetic field reduction effects. Calculated results show that the passive loop can be used to cost-effectively reduce power frequency magnetic fields in the vicinity of transmission lines generated by overhead transmission lines, compared with other reduction methods, such as active loop, increase in transmission line height, and power transmission using underground cables.

직교류 합성 충전 패턴을 이용한 풍력 연계용 ESS의 배터리 충전 효율 향상 (Improvement of Battery Charging Efficiency of ESS for Wind Power Application Using DC-AC Hybrid Charging Pattern)

  • 이종학;송승호
    • 전력전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.330-335
    • /
    • 2017
  • Increased fossil fuel consumption causes global warming, environmental pollution, and abnormal climate change. Wind-generated power installation is proposed to solve this problem. Recently, the wind power plant construction case encourages the installation of the energy storage system (ESS) to improve the intermittency of wind power. The maximized ESS operation profits connected to wind power are not generated in the simplest operation pattern of charging at night and discharging at day. The battery charging efficiency improvement should be considered to get more profits. Thus, there is a possibility of increasing ESS operation profits by analyzing the battery AC and DC charging/discharging efficiency and the yearly average sealed maintenance free (SMP) in hours. In this paper, the battery impedance characteristic, AC and DC charging/discharging efficiency, and the yearly average SMP are analyzed. The operation scenario to improve the ESS battery charging efficiency connected to wind power is proposed and verified via simulation.

LSTM을 활용한 풍력발전예측에 영향을 미치는 요인분석 (Analysis on Factors Influencing on Wind Power Generation Using LSTM)

  • 이송근;최준영
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.433-438
    • /
    • 2020
  • Accurate forecasting of wind power is important for grid operation. Wind power has intermittent and nonlinear characteristics, which increases the uncertainty in wind power generation. In order to accurately predict wind power generation with high uncertainty, it is necessary to analyze the factors affecting wind power generation. In this paper, 6 factors out of 11 are selected for more accurate wind power generation forecast. These are wind speed, sine value of wind direction, cosine value of wind direction, local pressure, ground temperature, and history data of wind power generated.

Hybrid coupler와 delay line을 사용한 PSK 변조 신호발생 회로해석 (Analysis of PSK modulation signal generation circuit using hybrid coupler and delay line)

  • 반경식;김영완
    • 한국정보통신학회논문지
    • /
    • 제13권2호
    • /
    • pp.227-232
    • /
    • 2009
  • 본 논문에서는 quadrature hybrid coupler를 사용하여 위상 변조 신호를 발생 할 수 있는 간단한 회로를 해석한다. 90o 위상차를 갖는 coupler 출력 단자의 반사 계수를 이용하여 일정한 위상 출력 값을 갖는 위상 변조 신호를 발생시키며, quadrature hybrid coupler와 지연 소자 그리고 전력 결합기 등 제안 구조를 사용하여 고차 PSK 신호를 발생할 수 있다. 하나의 90o hybrid coupler와 반사 소자에 의해 180o 위상차를 갖는 간단한 BPSK 신호 발생회로와 부가적인 지연 소자 및 전력 결합기에 의해 90o 위상차를 갖는 QPSK 신호를 발생한다. 모의 성능 실험 결과 3o 이내의 위상차를 갖는 양호한 PSK 신호 특성을 나타내었다.

중성선을 갖는 변압기형 초전도 한류기의 용량증대 개선 연구 (Analysis on the Improvement of Power Capacity Increase in the Transformer-Type SFCL with Neutral Lines)

  • 조용선;최효상;김덕구;고성필
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1438-1443
    • /
    • 2011
  • The increase of power capacity in the superconducting fault current limiter (SFCL) is essential for application into the power grid. To achieve this, when superconducting units were connected in series and parallel, the unbalanced quenching characteristics between superconducting units generated by different critical current behavior should be improved. In the transformer-type SFCL, the superconducting units connected in series could be simultaneously quenched by the connection of neutral lines between secondary coils and superconducting units. From this the consumed power in superconducting units was equally distributed. In addition, the more the turn ratio of the transformer was reduced, the more consumed power in the superconducting units was reduced by the decrease of the induction voltage generated in the superconducting units. From those results, the transformer-type SFCL using neutral lines could increase the power capacity of the SFCL by the equal power division into the superconducting units.

풍력-연료전지 하이브리드 시스템 출력의 동특성 분석 (Dynamic performances of output power of wind turbine and fuel-cell hybrid system)

  • 문대성;김윤성;서재진;원동준;박영호;문승일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.545-546
    • /
    • 2007
  • A hybrid system that uses a parallel combination of wind turbine and fuel cell is modeled. Wind energy source is characterized by its intermittent and variable nature. The output power generated by the fuel cell is stable and can be properly controlled. Therefore, fuel cell system can be added to the wind turbine system for the purpose of ensuring continuous power flow. Fuel cell helps to compensate power and regulate the frequency in power system. Simulation results show the effect of the hybrid system on power regulation. The excess power generated by the wind turbine was directed to an electrolyzer to generate hydrogen and the power deficit was compensated by the fuel cell.

  • PDF

단축식 태양광 추적장치의 설계와 발전량 증대기술 (Technology of single-axis solar tracking system and power generation increase)

  • 이재진;이교범;정규원
    • 한국산학기술학회논문지
    • /
    • 제21권7호
    • /
    • pp.212-217
    • /
    • 2020
  • 태양광 발전 시스템은 태양광 패널을 통해 발전된 전력을 계통연계를 통해 전송하는 종합 시스템이다. 발전량을 증대시키는 기술로써 태양광 입사각을 변화시켜 발전량을 증대시키는 추적식 태양광 발전장치 기술이 있다. 본 논문은 입사각을 변화시켜 발전량을 증대시키는 단축 추적식 태양광 발전장치의 구조물과 제어에 관한 연구이다. 핵심 내용은 태양광 구조물이 남북축을 중심으로 동서 방향으로 축회전하도록 구성한 단축 제어장치 및 기술이다. 일출로부터 일몰까지 동서방향으로 태양을 추종하는 태양광 구조물은 구조적 안정성과 태양광 추종 제어 성능 확보가 필요하다. 단축 추적 발전장치는 최대 25% 이상의 발전량 증대를 기대할 수 있다.

Effect of the incoherent earthquake motion on responses of seismically isolated nuclear power plant structure

  • Ahmed, Kaiser;Kim, Dookie;Lee, Sang H.
    • Earthquakes and Structures
    • /
    • 제14권1호
    • /
    • pp.33-44
    • /
    • 2018
  • Base-isolated nuclear power plant (BI-NPP) structures are founded on expanded basemat as a flexible floating nuclear island, are still lacking the recommendation of the consideration of incoherent motion effect. The effect of incoherent earthquake motion on the seismic response of BI-NPP structure has been investigated herein. The incoherency of the ground motions is applied by using an isotropic frequency-dependent spatial correlation function to perform the conditional simulation of the reference design spectrum compatible ground motion in time domain. Time history analysis of two structural models with 486 and 5 equivalent lead plug rubber bearing (LRB) base-isolators have been done under uniform excitation and multiple point excitation. two different cases have been considered: 1) Incoherent motion generated for soft soil and 2) Incoherent motion generated for hard rock soil. The results show that the incoherent motions reduce acceleration and the lateral displacement responses and the reduction is noticeable at soft soil site and higher frequencies.

Wavelet Transforms: Practical Applications in Power Systems

  • Akorede, Mudathir Funsho;Hizam, Hashim
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.168-174
    • /
    • 2009
  • An application of wavelet analysis to power system transient generated signals is presented in this paper. With the time-frequency localisation characteristics embedded in wavelets, the time and frequency information of a waveform can be presented as a visualised scheme. This feature is very important for non-stationary signals analysis such as the ones generated from power system disturbances. Unlike the Fourier transform, the wavelet transform approach is more efficient in monitoring fault signals as time varies. For time intervals where the function changes rapidly, this method can zoom in on the area of interest for better visualisation of signal characteristics.

Comparison of Signal Powers Generated with Different Shapes of Hammer Plates

  • Jeong, Ji-Hyun;Kim, Jin-Hoo
    • 한국지구과학회지
    • /
    • 제33권5호
    • /
    • pp.395-400
    • /
    • 2012
  • One of the main problems concerning the shallow seismic survey is how to generate high frequency signals with large amplitudes using small seismic sources. If one could focus the seismic energy in the direction of the survey line, it will be much helpful in identifying the first break. In this research, we have used hammer as an impulsive source and compared the signal powers generated by different shapes of the hammer plates: circular, square, and rectangular. The experiment was conducted by calculating the power spectral density function to compare the frequency spectrum and signal power. In the direction perpendicular to the long side of the rectangular plate, the largest seismic energy with the highest frequency was achieved even with the same weights of hammer plates. Our conclusion is that it is more efficient to use a rectangular plate than a circular (or square) one when conducting a 2-D shallow seismic survey.