• Title/Summary/Keyword: general values

Search Result 2,870, Processing Time 0.032 seconds

The Effect of Environmental Collage Making Class on Environmental Perception of the Gifted students (환경콜라주 제작수업이 영재학생들의 환경인식에 미치는 효과)

  • Kim, Soon-Shik
    • Journal of Environmental Science International
    • /
    • v.19 no.8
    • /
    • pp.1067-1076
    • /
    • 2010
  • How would environmental education be implemented for effectiveness today? Deep reflection on the way of teaching environment in classes to achieve effectiveness is required. If there exist differences in students' environmental perception depending on environment class pattern, its most effective way should be looked for. In environmental education, inducing the students to have advisable attitude voluntary about environment is more important than teaching them environmental knowledge. From such view, students' active participation is necessary for successful environmental classes. Students need to be set to share their principle, values, attitude about environment problems at environmental class through presentation which is important factor to make them have advisable environmental attitude. Therefore, environmental class need to be carried out student-led way. For that, a class model need to be designed which will be helpful for the students to arrange and elaborate their emitting thought about environment problems through disclosing their thoughts to share them with fellow students which will end up in their advisable environmental attitude. This study aimed to find out the effectiveness of environmental collage making class contributive to offering various environmental perception to students and grasping others' thinking about environment. Fifty-eight 10th graders at U Science High School in Ulsan metropolitan city were selected for the study that carried out from 2010 April to June by choosing total 10 environmental themes divided into environmental collage making class applied to the 30 test group students, and general environmental class applied to 28 control group students. Following are the study results. First, in students' environmental sensitivity, the students in the environmental collage making class appeared to be higher compared with them in general environmental class. Second, in students' intentional environment action, the students in the environmental collage making class appeared to be higher compared with them in general environmental class. Third, in students' satisfaction with environmental class, the students in the environmental collage making class appeared to be higher compared with them in general environmental class.

Efficacy of conservative treatment of perianal abscesses in children and predictors for therapeutic failure

  • Boenicke, Lars;Doerner, Johannes;Wirth, Stefan;Zirngibl, Hubert;Langenbach, Mike Ralf
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.7
    • /
    • pp.272-277
    • /
    • 2020
  • Background: The optimal management of perianal abscess in children is controversial. Purpose: To evaluate the efficiency of conservative treatment of perianal abscess in children and identify parameters that predict therapy failure. Methods: All cases of children younger than 14 years of age with perianal abscesses between 2001-2016 were evaluated. Results: Of the 113 enrolled patients, 64 underwent subsequent surgery for advanced disease (primary surgery group). Conservative treatment was initiated in 49 patients (primary conservative group) but was stopped because of inefficiency in 25 patients, who were referred for surgery after a median 7.03 days (range, 2 to 16 days). The other 24 patients (48%) initially achieved complete remission after conservative treatment, but 10 were readmitted after a median 34 months (range, 3 to 145 months) with recurrent disease. There were no significant differences in permanent success after conservative treatment between infants (10 of 29, 34%) and older children (4 of 20 [20%], P=0.122). Overall, conservative treatment alone was effective in only 14 of 113 patients. Recurrence after surgery occurred in 16 patients (25%) in the primary surgery group and 11 patients (22%) in the primary conservative group (P=0.75). Univariate analysis of predictors for conservative treatment failure revealed inflammatory values (C-reactive protein and white blood count, P=0.017) and abscess size (P=0.001) as significant parameters, whereas multivariate analysis demonstrated that only abscess size (odds ratio, 3.37; P=0.023) was significant. Conclusion: Conservative treatment of perianal abscess is permanently efficient in only a minority of children but is not associated with a higher recurrence rate after subsequent surgery. Abscess size is a predictor for therapy failure.

A Breast Cancer Nomogram for Prediction of Non-Sentinel Node Metastasis - Validation of Fourteen Existing Models

  • Koca, Bulent;Kuru, Bekir;Ozen, Necati;Yoruker, Savas;Bek, Yuksel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.3
    • /
    • pp.1481-1488
    • /
    • 2014
  • Background: To avoid performing axillary lymph node dissection (ALND) for non-sentinel lymph node (SLN)-negative patients with-SLN positive axilla, nomograms for predicting the status have been developed in many centers. We created a new nomogram predicting non-SLN metastasis in SLN-positive patients with invasive breast cancer and evaluated 14 existing breast cancer models in our patient group. Materials and Methods: Two hundred and thirty seven invasive breast cancer patients with SLN metastases who underwent ALND were included in the study. Based on independent predictive factors for non-SLN metastasis identified by logistic regression analysis, we developed a new nomogram. Receiver operating characteristics (ROC) curves for the models were created and the areas under the curves (AUC) were computed. Results: In a multivariate analysis, tumor size, presence of lymphovascular invasion, extranodal extension of SLN, large size of metastatic SLN, the number of negative SLNs, and multifocality were found to be independent predictive factors for non-SLN metastasis. The AUC was found to be 0.87, and calibration was good for the present Ondokuz Mayis nomogram. Among the 14 validated models, the MSKCC, Stanford, Turkish, MD Anderson, MOU (Masaryk), Ljubljana, and DEU models yielded excellent AUC values of > 0.80. Conclusions: We present a new model to predict the likelihood of non-SLN metastasis. Each clinic should determine and use the most suitable nomogram or should create their own nomograms for the prediction of non- SLN metastasis.

Effects of performing hip abduction and adduction during bridging exercise on trunk and lower extremity muscle activity in healthy individuals

  • Hwang, Joo Young;Ahn, Woo Young;Kim, Hyo Jae;Woo, Je Hyun;Choi, Woo Jin;Park, Jae Wook;Lee, Mi Young
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.1
    • /
    • pp.14-19
    • /
    • 2017
  • Objective: To investigate the effect of performing three different bridge exercise conditions on the activities of four different muscles using surface electromyography (sEMG) in healthy young adults. Design: Cross-sectional study. Methods: A total of 20 healthy young adults (10 males, 10 females) voluntarily participated in this study. All subjects randomly performed three different bridge conditions as follows: general bridge exercise, isometric hip abduction (IHAB) with a blue Theraband (Hygenic Corp., USA), and isometric hip adduction (IHAD) with a Swiss ball (Hygenic Corp.). The muscle activities of bilateral erector spinae (ES), gluteus maximus (GM), biceps femoris (BF), and external oblique (EO) muscles during the bridge exercises were measured using sEMG. Subjects performed each of the three bridge conditions three times in random order and mean values were obtained. Results: For bilateral ES and BF, there was a significant increase in muscle activity in the IHAD condition compared to the general bridge and IHAB condition (p<0.05). For bilateral GM, there was a significant increase in muscle activity in the IHAB condition compared to the general bridge condition (p<0.05) and there was a significant increase in muscle activity in the IHAB condition compared to IHAD condition (p<0.05). For left EO, a significant increase was observed in the IHAD condition compared to the general bridge condition (p<0.05). Conclusions: ES and BF muscle activity increases were observed with hip adduction and increased GM activity was observed with hip abduction. These findings may be applicable within the clinical field for selective trunk and lower extremity muscle activation and advanced rehabilitation purposes.

A Study on Radiation Dose and Image Quality according to CT Table Height in Brain CT (두부 CT 검사 시 테이블 높이에 따른 선량과 화질에 관한 연구)

  • Ki-Won Kim;Joo-Young Oh;Jung-Whan Min;Sang-Sun Lee;Young-Bong Lee;Kyung-Hwan Lim;Yun Yi
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.99-106
    • /
    • 2023
  • The height of the table should be considered important during computed tomography (CT) examination, but according to previous studies, not all radiology technologists set the table at the patient's center at the examination, which affects the exposure dose and image quality received by the patient. Therefore, this study intends to study the image quality exposure dose according to the height of the table to realize the optimal image quality and dose during the brain CT scan. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. For the exposure dose measurement, optically stimulated luminescence dosimeter (OSLD) was attached to the front, side, eye, and thyroid gland of the head phantom. In the signal to noise ratio (SNR) measurement result, The SNR values for each table height were all lower than 915 mm. As a result of exposure dose, the exposure dose on each area increased as the table height decreased. The height of the table has a close relationship with the patient's radiation exposure dose in the CT scan.

The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET ($^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석)

  • Park, Soon-Ki;Lee, Nam-Ki;NamGung, Chang-Kyung;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.100-103
    • /
    • 2010
  • Purpose: $^{18}F$-FDG wholebody PET is to evaluate the tumor using glucose metabolism. The blood glucose level is important factor that affects on a result of examination. High glucose levels may interfere with tumor targeting due to competitive inhibition of FDG uptake by D-glucose. The blood glucose level measurement test strips used in the blood glucose measurement are classified into the capillary blood measurement test strips and general purpose measurement test strips that can measure the venous blood and capillary blood altogether depends on cases. The purpose of the study was to compare the blood glucose measurements between simultaneously obtained capillary and venous blood samples using the capillary blood measurement test strips, general purpose measurement test strips. Materials and Methods: A total of 46 subjects (32 males, 14 females) with a mean age of $57.3{\pm}12.3$ years were enrolled. The blood glucose estimation was performed with a Optium Xceed Glucometer (Abbott). Simultaneous capillary and venous blood samples were obtained from each subject. The blood glucose levels were measured using the capillary blood measurement test strips and general purpose measurement test strips. The capillary and venous measurements were compared using a pared t-test. Results: The mean capillary and venous glucose values using the general purpose measurement test strips were $95.2{\pm}12.4$ mg/dL and $104.1{\pm}14.4$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (9.0 mg/dL; 95% confidence interval (CI) -11.2 to -6.7). The mean capillary and venous glucose values using the capillary blood measurement test strips were $91.5{\pm}13.6$ mg/dL and $108.6{\pm}16.2$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (16.6 mg/dL; 95% CI -20.2 to -13.0). Conclusion: When measuring the blood glucose level before $^{18}F$-FDG PET examination, since the incorrect blood glucose level can be measured, it should note to measure the blood glucose level of the venous blood by the capillary blood measurement test strips. Therefore the measurement variation can be reduced to fulfill the standardized measurement procedure with the suitable measurement test strips, the preparation of the PET examination will be able to be clearly confirmed. In addition, the standardized procedure of the following measurement on the area which is same at all times the blood area in the blood glucose measurement among a capillary or a vein will be needed.

  • PDF

Effect of Irradiation on the Color, Microbiological Quality, and Sensory Attributes of Frozen Ground Beef, Pork, and Chicken after 6 Months at $-6^{\circ}C$

  • Waje, Catherine;Kim, Mi-Yeung;Nam, Ki-Chang;Jo, Cheo-Run;Kim, Dong-Ho;Lee, Ju-Woon;Kwon, Joong-Ho
    • Food Science and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.212-215
    • /
    • 2008
  • The effect of gamma irradiation on the Hunter color values, microbiological quality, and sensory attributes of frozen ground beef, pork, and chicken was investigated. Fresh meat samples were purchased from local markets, packed and frozen in polyethylene bags, and irradiated at 5 kGy. The Hunter's L-values (lightness) were not significantly different in all the meat samples after irradiation, but the a-values (redness) were higher in the irradiated beef and pork than the non-irradiated ones. After 6 months of storage at $-6^{\circ}C$, the L-values increased in all the meat samples and the a-value in chicken was lower in the irradiated sample than that of the control. The microbial counts decreased in all the samples right after irradiation, but the coliforms and yeasts & molds increased by 1-2 log cycles after 6 months even under frozen state. The overall acceptability of the meat was not affected by irradiation. Panelists had a higher likeness for the increased redness in irradiated beef. In general, only the color changes in meat as a result of irradiation were found to be species-dependent.

Overview of the Development of the Korean Exposure Factors Handbook

  • Jang, Jae-Yeon;Jo, Soo-Nam;Kim, So-Yeon;Myung, Hyung-Nam
    • Journal of Preventive Medicine and Public Health
    • /
    • v.47 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • A set of exposure factors that reflects the characteristics of individual behavior capable of influencing exposure is essential for risk and exposure assessment. In 2007, the Korean Exposure Factors Handbook was, therefore, issued, driven by the need to develop reliable exposure factors representing the Korean population. The purpose of this study was to overview the development process of the Korean Exposure Factors Handbook and major recommended exposure values for the Korean population to allow information exchanges and comparison of recommended values among nations. The researchers reviewed the domestic data that could be used in the development of exposure factors, confirmed a knowledge gap, and set a priority of development by phases. A methodology to measure exposure factors was established to develop measuring techniques and test their validity. Data were processed or a survey was conducted according to the availability of data. The study thus produced recommended values for 24 exposure factors grouped by general exposure factors, food ingestion factors, and activity factors by setting up a database of exposure factors and carrying out statistical analysis. The study has significantly contributed to reducing the potential uncertainty of the risk and exposure assessment derived by the application of foreign data or research findings lacking representativeness or grounds by developing a set of exposure factors reflecting the characteristics of the Korean people. It will be necessary to conduct revisions in light of the changing statistical values of national data and the exposure factors based on Korean characteristics.

Electromyographic Analyses of the effects of different foot positions during exercise on a stair-climbing machine (스텝 운동 기구를 사용한 운동 시 발의 위치가 하지 근육 활동에 미치는 영향 분석)

  • Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.1
    • /
    • pp.207-219
    • /
    • 2005
  • The purpose of this study was to determine the effect of the foot rotation on the lower limb muscles. Fourteen subjects performed step-up/step-down at a cadence of 80 beats/min, exercises with the foot neutral, $35^{\circ}$ internally rotated, and $35^{\circ}$ externally rotated, respectively. For each variable, a one-way analysis of variance (ANOVA) was used to determine whether there were significant differences between genders and among the eight types of jump. When a significant difference was found in jump type, post hoc analyses were performed using the Tukey procedure. A confidence level of p < .05 was used to determine statistical significance. The results showed that significant changes in averaged IEMG values occurred with the internal rotation of the foot in the lateral gastrocnemius during the knee extension, and in the semitendinosus during the knee flexion. During the knee extension, however, the internal rotation of the foot produced a significantly lower Averaged IEMG values than the neutral foot position in the medial gastrocnemius. The results also found that the peak IEMG activity of the rectus femoris during the knee extension for the external rotation of the foot was Significantly higher than the corresponding values in the neutral position of the foot, while the intenal rotaion of the foot exhibited a significant difference with the neutral position of the foot in the semitendinosus during the knee flexion. In general, the foot rotation position did not influence the average IEMG and Peak IEMG values of most muscles. The practice of adopting foot rotation to selectively strengthen individual muscles of the lower limb was not supported by this study. The external rotation of the foot produced high muscle activities in the quadriceps during the knee extension. For the knee extension, therefore, maintaining a laterally rotated position should be need for stable and comfortable position.

Comparison of Sphygmomanometer, Fully Automatic Electronic Blood Pressure Meters with Standard Digital Blood Pressure Monitor : Pilot Study (표준전자식 혈압계와 수은혈압계, 전자혈압계의 비교 선행연구)

  • Yahng, J.S.;Lim, H.K.;Cho, D.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.155-162
    • /
    • 2012
  • Devices to measure the blood pressure of patients are being used without any calibration in a hospital. It is an important to show consistent values when any medical devices measure the same patients regardless they are sphygmomanometer or fully automatic electronic blood pressure meter. We compared sphygmomanometer and fully automatic electronic blood pressure meters with standard digital blood pressure monitor (SDBPM) to evaluate the consistency of the small healthy subjects. We measured the blood pressure from six healthy subjects (three of 20~40 years and three of 40~60 years old). Two sphygmomanometer and two fully automatic electronic blood pressure meters were used and compared with the SDBPM. Blood pressures measured from right and left arms each and were compared. All six healthy subjects showed normal blood pressure values. In general, left blood pressure values showed higher values than right side. Comparing SDBPM, with the other monitors, the systolic pressure showed ${\pm}$ 34.8% difference and ${\pm}$ 33.3% for the diastolic pressure. Correlation between SDBPM and Sphygmomanometer was 0.59~0.71, and 0.50~0.70 for fully automated digital BP monitors. It fell in grade-D when we apply the BHS(British hypertension society). AAMI(American association for the advancement of medical instrumentation) also showed unsatisfactory results for the mean value (${\leq}$ 5 mmHg) and standard deviation (${\leq}$ 8 mmHg). We tested sphygmomanometer and fully automatic electronic blood pressure meters and compared with a standard digital blood pressure monitor. All devices showed inconsistent blood pressures. A reliable calibration system is highly needed for all devices in all hospitals.