• Title/Summary/Keyword: general values

Search Result 2,829, Processing Time 0.033 seconds

Flow Resistance and Modeling Rule of Fishing Nets 5. Total Resistance of Bottom Trawl Nets Subjected Simultaneously to the Water Flow and the Bottom Friction (그물어구의 유수저항과 모형수칙 5. 저층 트롤그물의 예망저항)

  • KIM Dae-An
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.5
    • /
    • pp.700-707
    • /
    • 1997
  • In order to express exactly the total resistance of bottom trawl nets subjected simultaneously to the water flow and the bottom friction, the influence of frictional force was added to the formular for the flow resistance of trawl nets obtained by previous papev and the experimental data obtained by other investigators were analyzed by the formula. The analyzation produced the total resistance R (kg) expressed as $$R=4.5(\frac{S_n}{S_m})^{1.2}S\;v^{-1.8}+20(Bv)^{1.1}$$ where $S(m^2)$ was the wall area of nets, $S_m\;(m^2)$ the cross-sectional area of net mouths, $S_n\;(m^2)$ the area of nets projected to the plane perpendicular to the water flow, B (m) the made-up circumference at the fore edge of bag parts, and v(m/sec) the dragging velocity. From the viewpoint that expressing R in the form of $R=kSv^2$ was a usual practice, however, the resistant coefficient $k(kg{\cdot}sec^2/m^4)$ was compared with the factors influencing it by reusing the experimental data. The comparison gave that the coefficient k might be expressed approximately as a function of BL only and so the resistance R (kg) as $$R=18{\alpha}B^{0.5}L\;v^{1.5}$$ where L (m) was the made-up total length of nets and $\alpha=S/BL$. But the values of a in the nets did not deviate largely from their mean, 0.48, for all the nets and so the general expression of R (kg) for all the bottom trawl nets could be written as $$R=9\;B^{0.5}\;L\;v^{1.5}$$.

  • PDF

The new explore of the animated content using OculusVR - Focusing on the VR platform and killer content - (오큘러스 VR (Oculus VR)를 이용한 애니메이션 콘텐츠의 새로운 모색 - VR 플랫폼과 킬러콘텐츠를 중심으로 -)

  • Lee, Jong-Han
    • Cartoon and Animation Studies
    • /
    • s.45
    • /
    • pp.197-214
    • /
    • 2016
  • Augmented Reality, virtual reality in recently attracted attention throughout the world. and Mix them mixed reality etc., it has had a significant impact on the overall pop culture beyond the scope of science and technology. The world's leading IT company : Google, Apple, Samsung, Microsoft, Sony, LG is focusing on development of AR, VR technology for the public. The many large and small companies developed VR hardware, VR software, VR content. It does not look that makes a human a human operation in the cognitive experience of certain places or situations or invisible through Specific platforms or program is Encompass a common technique that a realization of the virtual space. In particular, out of the three-dimensional image reveals the limitations of the conventional two-dimensional structure - 180, 360 degree images provided by the subjective and objective symptoms such as vision and sense of time and got participants to select it. VR technology that can significantly induce the commitment and participation is Industry as well as to the general public which leads to the attention of colostrum. It was introduced more than 10 related VR works Year 2015 Sundance Film Festival New Frontier program. The appearance VR content : medical, architecture, shopping, movies, animations. Also, 360 individuals can be produced by the camera / video sharing VR is becoming an interactive tunnel between two possible users. Nevertheless, This confusion of values, moral degeneration and the realization of a virtual space that has been pointed out that the inherent. 4K or HUD, location tracking, motion sensors, processing power, and superior 3D graphics, touch, smell, 4D technology, 3D audio technology - It developed more than ever and possible approaches to reality. Thereafter, This is because the moral degeneration, identity, generational conflict, and escapism concerns. Animation is also seeking costs in this category Reality. Despite the similarities rather it has that image, and may be the reason that the animation is pushed back to the VR content creation. However, it is focused on the game and VR technology and the platform that is entertaining, but also seek new points within the animation staying in the flat Given that eventually consist of visual images is clear that VR sought. Finally, What is the reality created in the virtual space using VR technology could be applied to the animation? So it can be seen that the common interest is research on what methods and means applied.

Evaluation of Setup Error Correction for Patients Using On Board Imager in Image Guided Radiation Therapy (Image Guided Radiation Therapy (IGRT) 시 On Board Imager를 이용한 환자 Setup Error 보정평가)

  • Kang, Soo-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.69-81
    • /
    • 2008
  • Purpose: To reduce side effects in image guided radiation therapy (IGRT) and to improve the quality of life of patients, also to meet accurate SETUP condition for patients, the various SETUP correction conditions were compared and evaluated by using on board imager (OBI) during the SETUP. Materials and Methods: Each 30 cases of the head, the neck, the chest, the belly, and the pelvis in 150 cases of IGRT patients was corrected after confirmation by using OBI at every 2∼3 day. Also, the difference of the SETUP through the skin-marker and the anatomic SETUP through the OBI was evaluated. Results: General SETUP errors (Transverse, Coronal, Sagittal) through the OBI at original SETUP position were Head & Neck: 1.3 mm, Brain: 2 mm, Chest: 3 mm, Abdoman: 3.7 mm, Pelvis: 4 mm. The patients with more that 3 mm in the error range were observed in the correction devices and the patient motions by confirming in treatment room. Moreover, in the case of female patients, the result came from the position of hairs during the Head & Neck, Brain tumor. Therefore, after another SETUP in each cases of over 3 mm in the error range, the treatment was carried out. Mean error values of each parts estimated after the correction were 1 mm for the head, 1.2 mm for the neck, 2.5 mm for the chest, 2.5 mm for the belly, and 2.6 mm for the pelvis. Conclusion: The result showed the correction of SETUP for each treatment through OBI is extremely difficult because of the importance of SETUP in radiation treatment. However, by establishing the average standard of the patients from this research result, the better patient satisfaction and treatment results could be obtained.

  • PDF

Radioprotective Effects of Aronia on Radiation Irradiated Rats (방사선에 조사된 쥐에서 아로니아의 방사선 방호효과)

  • Mun, Hwan-Sik;Lee, Jun-Haeng
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.423-431
    • /
    • 2017
  • The present study was intended to orally administer aronia to rats, irradiate radiation once to the whole bodies of the rats, and conduct blood tests to observe, compare, and analyze changes in blood cells, such as leukocytes, erythrocytes, and platelets, in order to examine the radioprotective effects of aronia. As experimental animals, 15 male Sprague-Dawley (SD) rats aged six weeks weighing 200~250 g were taken and divided into the normal group (A) of five rats, the 5 Gy control group (B) of five rats, and the 5 Gy experimental group (C) of five rats. The normal group (A) was not~irradiated at all, the control group (B) was administered with general diets and irradiated, and the experimental group(C) was orally administered with 50 mg/kg/day of aronia two times per day to achieve a distilled water oral dose of 100 mg/kg/day and irradiated thereafter (5 Gy at 500 cGy/min) for 14 days. After the experiment, differences in leukocytes, erythrocytes, and platelets among the normal group (A), the control group (B), and the experimental group (C) were examined by comparing the counts of the blood cells and the results showed no statistically significant differences. However, on a detailed review, the normal group (A) showed statistically higher mean values for all of lymphocytes, hemoglobin, and mean corpuscular hemoglobin as compared to the control group (B) and the experimental group (C). Statistically significant differences in the counts of lymphocytes were shown between the normal group (A) and the control group (B), and between the normal group (A) and the experimental group (C); furthermore, statistically significant differences in mean corpuscular hemoglobin were shown between the normal group (A) and the experimental group (C). Given the results of the present study, in irradiated rats, aronia was generally considered as having no radioprotective effect on leukocyte, erythrocyte, and platelet while having statistically significant radioprotective effects on lymphocytes, hemoglobin, and mean corpuscular hemoglobin. Based on the present experiment, diverse studies should be conducted hereafter.

Health Economic Approach to End-of-Life Care in the US: Based on Medicare (말기의료의 경제적 요소에 관한 논의: 미국 메디케어 상황을 중심으로)

  • Suk, Ryan
    • The Korean Society of Law and Medicine
    • /
    • v.15 no.1
    • /
    • pp.335-373
    • /
    • 2014
  • According to one Medicare report, in the US, total federal spending on health care expends almost 18 percent of the nation's GDP, about double what most industrialized nations spend on health care. And in 2011, Medicare spending reached close to $554 billion, which amounted to 21 percent of the total spent on U.S. health care in that year. Of that $554 billion, Medicare spent 28 percent, or about $170 billion, on patients' last six months of life. So what are the reasons of this high cost in EOL care and its possible solutions? Much spendings of Medicare on End-of-Life care for the terminally ill/chronically ill in the US has led health economics experts to assess the characteristics of the care. Decades of study shows that EOL care is usually supply-sensitive and poor in cost-effectiveness. The volume of care is sensitively depending on the supply of resources, rather than the severity of illness or preferences of patients. This means at the End-of-Life care, the medical resources are being overused. On the other hand, opposed to the common assumption, "The more care the better utility", the study shows that the outcome is very poor. Actually the patient preference and concerns are quite the opposite from what intense EOL care would bring about. This study analyzes the reasons for the supply-sensitiveness of EOL care. It can be resulted from the common misconception about the intense care and the outcome, physicians' mission for patients, lack of End-of-Life Care Decision which helps the patients choose their own preferred treatment intensity. It also could be resulted from physicians' fear of legal liabilities, and the management strategy since the hospitals are also seeking for financial benefits. This study suggests the possible solutions for over-treatment at the End-of-Life resulting from supply-sensitiveness. Solutions can be sought in two aspects, legal implementation and management strategy. In order to implement advance directive properly, active ethics education for physicians to change their attitude toward EOL care and more conversations about end-of-life care between physicians and patients is crucial, and incentive system for the physicians who actively have the conversations with patients will also help. Also, the general education towards the public is also important in the long run, and easy and official advance directive registry system-such as online registry-has to be built and utilized more widely. Alternative strategies in management are also needed. For example, the new strategic cost management and management education, such as cutting unnecessary costs and resetting values as medical providers have to be considered. In order to effectively resolve the problem in EOL care for the terminally ill/chronically ill and provide better experience to the patients, first of all, the misconception and the wrong conventional wisdom among doctors, patients, and the government have to be overcome. And then there should be improvements in systems and cultures of the EOL care.

  • PDF

Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image ($T_2^*$ and FLAIR) Sequence (뇌의 확산강조 영상에서 b-value의 변화에 따른 신호강도, 현성확산계수에 관한 비교 분석 : 확산강조 에코평면영상($T_2^*$ 및 FLAIR)기법 중심으로)

  • Oh, Jong-Kap;Im, Jung-Yeol
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.313-323
    • /
    • 2009
  • Diffusion-weighted imaging (DWI) has been demonstrated to be a practical method for the diagnosis of various brain diseases such as acute infarction, brain tumor, and white matter disease. In this study, we used two techniques to examine the average signal intensity (SI) and apparent diffusion coefficient (ADC) of the brains of patients who ranged in age from 10 to 60 years. Our results indicated that the average SI was the highest in amygdala (as derived from DWI), whereas that in the cerebrospinal fluid was the lowest. The average ADC was the highest in the cerebrospinal fluid, whereas the lowest measurement was derived from the pons. The average SI and ADC were higher in $T_2^*$-DW-EPI than in FLAIR-DW-EPI. The higher the b-value, the smaller the average difference in both imaging techniques; the lower the b-value, the greater the average difference. Also, comparative analysis of the brains of patients who had experienced cerebral infarction showed no distinct lesion in the general MR image over time. However, there was a high SI in apparent weighted images. Analysis of other brain diseases (e.g., bleeding, acute, subacute, chronic infarction) indicated SI variance in accordance with characteristics of the two techniques. The higher the SI, the lower the ADC. Taken together, the value of SI and ADC in accordance with frequently occurring areas and various brain disease varies based on the b-value and imaging technique. Because they provide additional useful information in the diagnosis and treatment of patients with various brain diseases through signal recognition, the proper imaging technique and b-value are important for the detection and interpretation of subacute stroke and other brain diseases.

  • PDF

Functional Brain Mapping Using $H_2^{15}O$ Positron Emission Tomography ( I ): Statistical Parametric Mapping Method ($H_2^{15}O$ 양전자단층촬영술을 이용한 뇌기능 지도 작성(I): 통계적 파라메터 지도작성법)

  • Lee, Dong-Soo;Lee, Jae-Sung;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.225-237
    • /
    • 1998
  • Purpose: We investigated the statistical methods to compose the functional brain map of human working memory and the principal factors that have an effect on the methods for localization. Materials and Methods: Repeated PET scans with successive four tasks, which consist of one control and three different activation tasks, were performed on six right-handed normal volunteers for 2 minutes after bolus injections of 925 MBq $H_2^{15}O$ at the intervals of 30 minutes. Image data were analyzed using SPM96 (Statistical Parametric Mapping) implemented with Matlab (Mathworks Inc., U.S.A.). Images from the same subject were spatially registered and were normalized using linear and nonlinear transformation methods. Significant difference between control and each activation state was estimated at every voxel based on the general linear model. Differences of global counts were removed using analysis of covariance (ANCOVA) with global activity as covariate. Using the mean and variance for each condition which was adjusted using ANCOVA, t-statistics was performed on every voxel To interpret the results more easily, t-values were transformed to the standard Gaussian distribution (Z-score). Results: All the subjects carried out the activation and control tests successfully. Average rate of correct answers was 95%. The numbers of activated blobs were 4 for verbal memory I, 9 for verbal memory II, 9 for visual memory, and 6 for conjunctive activation of these three tasks. The verbal working memory activates predominantly left-sided structures, and the visual memory activates the right hemisphere. Conclusion: We conclude that rCBF PET imaging and statistical parametric mapping method were useful in the localization of the brain regions for verbal and visual working memory.

  • PDF

The Effects of Aprotinin Addition and Plastic Tube Usage for Glucagon Test Results (Glucagon 검사시 Aprotinin 첨가와 Plastic tube 사용이 미치는 영향)

  • Cho, Youn-Kyo;Choi, Sam-Kyu;Seo, So-Yeon;Shin, Yong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.117-120
    • /
    • 2011
  • Purpose: There are 3 warnings for Glucagon tests. First, EDTA tubes that already contain Aprotinin must be used for plasma collection. Second, for freezer storage of centrifuged plasma, glass tubes must be used. Last, glass tubes must be used for testing procedure. So we compared the glucagon results of next 3 situation to those of control group. First, We compared to results by tubes without Aprotinin and with aprotinin. Second, we compared to results by tubes(plastic vs glass) for plasma storage. Third, we compared to results by tubes(plastic vs glass) for testing. We tried to evaluate the results of the 3 different condition. Materials and Methods: 40 healthy adults were studied with normal results on the general medical check up and laboratory tests. We compared the results of 3 different condition belows: Blood were collected in EDTA tube containing aprotinin and plasma was stored in the glass tube for 3 days in a freezer and results were obtained by tests in the glass tubes. Results from EDTA plasma without aprotinin, results from platic tubes for freezer stroage, results from plastic tube when testing. Simple linear regression analysis and paired t-test using SPSS were done for statistical analysis. Commercial glucagon kit(RIA-method)which made by Siemens company were used. Results: Correlation coefficient between results of EDTA tubes with Aprotinin vs without Aprotinin was r=0.783 (p=0.064). Result of specimen in plastic tubes stored 3 days in a freezer showed lower value compared to those in glass tube(r=0.979, p=0.005). Also, results of testing in plastic tubes showed lower values than those testing in glass tubes. (r=0.754, p<0.001). Conclusion: It is recommended for glucagon determination to use EDTA tube with Aprotinin which is a inhibitor of protein breakdown enzyme. Results of plastic tube when storage and testing showed lower value than those of glass tubes, so it is recommended to store and test in glass tubes.

  • PDF

Development of Leaf Protein Concentrates II. Extraction of Leaf Protein Concentrates of Some Plants Growing in Korea (잎 단백질(蛋白質)(Leaf Protein Concentrates)의 개발(開發)에 관한 연구(硏究) II. 한국산(韓國産) 각종 식물(植物)로 부터의 잎 단백질(蛋白質)의 추출(抽出))

  • Choe, Sang;Kim, Geon-Chee;Chun, Myung-Hi;Kim, Kil-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.17-25
    • /
    • 1970
  • Juice were extracted from fresh leaves of 70 species of plants growing in Korea by mincing and pressing the resulting pulp through a cotton cloth. Leaf protein concentrates could be prepared from many species of land and water plants that are at present economically unimportant. The choice of plants is of considerable important. Total-N, protein-N and pH determinations were made on the extracts, and total-N remaining in the fibre were calculated. Leaf protein concentrates were precipitated from the extracts at $75{\sim}80^{\circ}C$, and analysed total-N as protein-N of products. The present paper deals with the calculated yields of leaf protein concentrates from various plants, relations between yield of leaf protein concentrates and total-N of leaves, or pH of extracts, and the amino acid compositions of leaf protein concentrates. Results are summarized as follows. 1. Spinach and radish were the best sources of easily extractable, but good results were also obtained with indian mustard, kail, chenopod, red bean, cucumber, squash, houndberry, white flowered gourd, potato, Humulus japonicus, arrowroot and soybean as a good resources for the production of leaf protein concentrates. 2. In general, the greater the protein content of leaves the greater the yield of leaf protein concentrates. However, there are some plants difficult to make a adequate protein extraction by a simple mechanical process. 3. It was to be expected that leaf protein concentrates would be more extractable with the higher pH of extracts. There were a poor yield of the leaf protein concentrate in the pH values lower than 5.50 of the first extracts. 4. Protein content of the leaf protein concentrate shows marked differences, depending on species and season. It ranged between 29 to 80% of protein contents. However, the majority of plants yielded products containing more than 50% of protein. Products containing more than 75% of protein were obtained from two species of radish and indian mustard. Cabbage and Digitaria sanguinalis cilialis (summer) made products containing 29 to 32% of protein. 5. The amino acid composition of leaf protein concentrates was not greatly altered by species of plants. On an amino acid compositional basis, the leaf protein concentrate has a favorable balance of essential and non-essential amino acids, the only exception being methionine, which was usually low in all cases.

  • PDF

Gender Difference of Accuracy in Detecting Coronary Artery Disease by Myocardial Perfusion SPECT (디피리다몰 심근관류 SPECT를 이용한 관동맥질환 진단에 있어 남녀간의 진단율 비교)

  • Min, Jung-Jun;Bom, Hee-Seung;Song, Ho-Cheon;Jeong, Hwan-Jeong;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.129-136
    • /
    • 1998
  • Purpose: Myocardial SPECT is an effective test for detecting coronary artery disease in the general population. But the diagnostic accuracy between sexes is not defined. The purpose of this study is to compare the diagnostic accuracy between males and females. Materials and Methods: One hundred and seventy seven male and 98 female patients who underwent myocardial SPECT within 1 month of coronary angiography were studied. Myocardial SPECTS were considered abnormal if fixed or reversible perfusion defects were detected. Stenosis severity of ${\geq}$ 50% luminal diameter reduction of any artery defined coronary artery disease (CAD). Results: Overall sensitivity for detection of CAD was 98% in men and 97% in women (p=not significant). However, specificities, accuracies, and positive predictive values (PPV) in men and women were 49% vs 31% (p<0.05), 81% vs 57% (p<0.01), 78% vs 48% (p<0.01), respectively. Diagnostic accuracies for detection of right coronary artery disease were not different in both sexes, however, accuracies for detection of left anterior descending artery disease and left circumflex artery disease were significantly lower in female (p<0.05). Conclusion: A significant difference of diagnostic accuracy between sexes, especially in LAD and LCx disease, was noted. Artifacts from breast attenuation might be a cause for the lower diagnostic accuracy in female.

  • PDF