• Title/Summary/Keyword: gauge function

Search Result 141, Processing Time 0.026 seconds

Evaluation of Circle Machining Surface Roughness on the Process Conditions using Neural Network (신경회로망을 이용한 가공조건에 따른 원형가공 표면거칠리 평가)

  • Sung, Baek-Sup;Kim, Ill-Soo;Cha, Yong-Hun
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.1
    • /
    • pp.11-17
    • /
    • 2002
  • The purpose of this study was to present the method to choose the optimization machining condition for the wire electric machine. This was completed by examining the ever-changing quality of the material and by improving the function of the wire electric discharge machine. Precision metal mold products and the unmanned wire electric discharge machining system were used and then applied in industrial fields. This experiment uses the wire electric discharge machine with brass wire electrode of 0.25mm. To measure the precision of the machining surface, average values are obtained from 3 samples of measures of center-line average roughness by using a third dimension gauge and a stylus surface roughness gauge. In this experiment, we changed no-node voltage to 7 and 9, pulse-on-time to $6{\mu}s,\;8{\mu}s$ and $10{\mu}s$, pulse-off-time to $8{\mu}s,\;10{\mu}s$ and $13{\mu}s$, and experimented on wire tension at room temperature by 1000gf, 1200gf, and 1400gf, respectively.

Improvement of Sensitivity in Micro Magnetoelastic Strain Sensors (마이크로 자기탄성스트레인센서의 고감토화)

  • Shin, K.H.;Hur, J.;Choi, H.I.;Kim, Y.H.;Sa-Gong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.423-426
    • /
    • 2001
  • Recently we have reported that the meander-patterned amorphous FeCoSiB films exhibit large change in their high frequency impedance by applying a strain, suggesting that the films are very attractive for making of a highly sensitive strain sensor elements. In this study, the effect of anisotropy on a change in the impedance of sputtered amorphous film patterns was investigated in the frequency range from 1MHz to 1GHz. As a function of applied strains, the high frequency impedance was extremely changed in the case of film patterns with transverse anisotropy due to excellent magnetomechanical coupling properties. As a summary, the maximum figure of merit f has measured about 2600 in the case of transverse anisotropy, and about 500 in the case of longitudinal anisotropy at 500 MHz. These values of F are approximately more than 1000 times higher than that of a conventional metal strain gauge (F 2) and more than 10 times higher than that of a semiconductor gauge (F 200).

  • PDF

Study on Torque precision measuring System using Curve Fitting Algorithm (커브피팅 알고리즘이 적용된 토크 정밀 측정 시스템 개발에 관한 연구)

  • Lee, Ki Won;Ha, Jae Seung;Kang, Seung Soo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.8 no.4
    • /
    • pp.1-11
    • /
    • 2012
  • This paper is the study on the development of a torque precision measuring system using the curve fitting algorithm. This system can be divided into the hardware part and the software part. The hardware part consists of the main base board, the DAQ(Data Aquisition) board and Calibration parts. The software part consists of the software filter module and the curve fitting algorithm module. We have tested the torque transducer including the strain gauge for 200 Nm range and have analyzed the data acquired with the curve fitting algorithm by using this system. The DAQ board converts the electric signal induced by the transducer to the digital value precisely by using the shunt calibration procedure. The main board including the curve fitting algorithm calculates the exact digital torque value by using the digital value from the DAQ board. In this study, we confirmed that the result of the appropriate high-order power-series polynomial function is more accurate than the result of the low-order power-series polynomial through the system.

Effect of Cooling Water Temperature on Heat Transfer Characteristics of Water Impinging Jet (냉각수 온도에 따른 수분류 충돌제트의 열전달 특성 연구)

  • Lee, Jungho;Yu, Cheong-Hwan;Do, Kyu Hyung
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.5
    • /
    • pp.249-256
    • /
    • 2010
  • Water jet impingement cooling has been widely used in a various engineering applications; especially in cooling of hot steel plate of steelmaking processes and heat treatment in hot metals as an effective method of removing high heat flux. The effects of cooling water temperature on water jet impingement cooling are primarily investigated for hot steel plate cooling applications in this study. The local heat flux measurements are introduced by a novel experimental technique that has a function of high-temperature heat flux gauge in which test block assemblies are used to measure the heat flux distribution during water jet impingement cooling. The experiments are performed at fixed flow rate and fixed nozzle-to-target spacing. The results show that effects of cooling water temperature on the characteristics of jet impingement heat transfer are presented for five different water temperatures ranged from 5 to $45^{\circ}C$. The local heat flux curves and heat transfer coefficients are also provided with respect to different boiling regimes.

A System Development, Performance Assessment, and Service Implementation of ATM-based High-rate Digital Subscriber Line (HDSL) (ATM 기반 HDSL 개발, 동 선로 상의 성능 평가 및 서비스 구현)

  • 양충열
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.6
    • /
    • pp.1562-1574
    • /
    • 1998
  • We, in this paper, have implemented T1, E1 and fractional E1 HDSL(High-bit-rate digital subscriber line) function over an ATM switching system. The maxi$\mu$ loop lengths for subscriber service and cell loss rates to meet the bit error rate of 10$^{-7}$ at transmission of 2B1Q HDSL data E1 rate over existing telephone copper wires in the presence of the significant impairments such as NEXT(Nearned crosstalk), impulse noise, power line noise and longitudinal over the CSAs environment consisting of 26 gauge and 25 gauge unloaded copper telephone lines has assessed. HDSL will intially be used to serve private-DS1, ISDN-BRA, and DLC feeders, later DS1 extension from optic fiber cable. We also present market provision for the HDSL.

  • PDF

A Experimental Study on the Formal and Physiological Change of Body according to the Wearing-Brassiere Condition. (Brassiere 착용조건에 따른 신체의 형태적, 생리적 변화에 관한 심리적 연구)

  • 박영득
    • Journal of the Korean Home Economics Association
    • /
    • v.29 no.1
    • /
    • pp.27-35
    • /
    • 1991
  • This study was carried out to investigate the influence of the various physiological function caused by brassiere wearing. The four experimental methods used in this study are as follows. For example, the Roentgen photographing, Body measurement by Sliding Gauge, the measurement of the Electrocardiogram and Blood Pressure. The results of the Electrocardiogram and Blood Pressure. The results of the investigation were as follows: 1. In experimental change by Sliding Gauge and Body measurement, The bust point was rised in order AB1>B2. The width of right and left bust point was decreased in order of A>B1>B2. According to, The supplementary effect of brassiere wearing was excellent in B2. 2. In the change of various organs by Roentgen photographing, The width of the chest and size of the heart were decreased in regular order of A>B1>B2. The diaphragm and the others were not showed change. 3. In the experimental result by measurement of the electrocardiogram, The interval of heart palpitation was decreased in order A>B1>B2 and the pulse frequency was similar. 4. In the experimental result by the blood pressure measurement, A had the highest blood pressure and B2 had the lowest pressure in all variables.

  • PDF

Calculation of $^{13}C, ^{15}N,\; and \;^{29}Si$ NMR Shielding Tensors for Selected X-Substituted Silatranes Using GIAO/CSGT-SCF

  • 김동희;이미정;오세웅
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.8
    • /
    • pp.847-851
    • /
    • 1998
  • 13C, 15N, and 29Si NMR chemical shifts have been computed for selected X-substituted silatranes (X=Cl, F, H, CH3) using Gauge-Including Atomic Orbitals (GIAO) and Continuous Set of Gauge Transformations (CSGT) at the Hartree-Fock level of theory. The isotropic 13C chemical shifts are largely insensitive to substituent-induced structural changes. In this study, the isotropic 13C chemical shifts GIAO and CSGT calculations at the HF/6-31G and HF/6-31G* levels are sufficiently accurate to aid in experimental peak assignments. The isotropic 13C chemical shifts X-substituted silatranes at HF/6-31G* level are approximately 4 ppm different from the experimental values. In contrast, the isotropic 15N and 29Si chemical shifts and the chemical shielding tensors are quite sensitive to substituent-induced structural changes. These trends are consistent with those of the experiment. The 15N chemical shift parameters demonstrate a very clear correlation with Si-N distance, especially when we use the polarization function. Changes in anisotropy, 3a as well as in the 15N isotropic chemical shifts are due primarily to changes in the value of a.. But in case of "Si the correlations are not as clean as for the 15N chemical shift.

Study on the Behavior of the Fish - 1 . The Swimming Force of Crusian Carp , Carassius Carassius - (어류의 행동에 관한 연구 - 1 . 붕어의 유영력 -)

  • 손태준
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.1
    • /
    • pp.1-5
    • /
    • 1984
  • The author carried out an experiment for the dynamical swimming force of crusian carp, Carassius carassius. The experimental water tank was made of 4mm thick transparent acryl board in the right hexahedral shape (400L$\times$240W$\times$800H mm). The water temperature in the tank ranged 20.6$^{\circ}C$ to 21.2$^{\circ}C$. The water level in the tank was maintained 70cm high from the bottom. The measurement of the swimming force was carried out by use of strain gauge. The results obtained can be summarized as follows: 1) The momentary maximum swimming force F sub(M) (g) and the sustainable maximum swimming force F sub(s) (g) can be expressed as a function of the body weight W(g). F sub(M) =1.45W, F sub(s) =0.29W where the momentary maximum swimming force means the highest value, and the sustainable maximum swimming force means the mean high value sustained for 4 to 5 seconds presented in the recording paper. 2) F sub(M) and F sub(s) can be expressed as a function of the body length L(cm). F sub(M) =0.11L super(2.63), F sub(s) =0.15L super(1.77) 3) The coefficient of hydraulic resistance for crusian carp was derived as 0.287.

  • PDF

A Study on the Seam tracking for container box manufacture (컨테이너 제작을 위한 용접선 추적에 관한 연구)

  • Pyo, Jong-Woo;An, Byong-Won;Eom, Han-Sung;Nam, Taek-Kun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.195-199
    • /
    • 2005
  • Semi automatic welding method to use carriage for welding at large size block manufacture welding process of present shipbuilding industry is used much. Carriage is device that transfer welding torch in horizontal fillet weld here, but because it is no function that chase welding like robot welding method, use can be impossible in curved line welding, and simply use in straight line welding. Also, because it is no function that chase welding, though welding mistake corrects this happening often in straight line welding, much times and expense are cost. Added welding chase sensor and 80C196KC microcontroller that use strain gauge to carriage that is using present in paper that see hereupon and manufacture a private line model and container box model welding because developing system that can chase welding automatically straight line and curved line welding establishing and investigate about chase phenomenon.

  • PDF

Spectral Characteristics and Nasalance Scores of Hypernasality in Patient with Cleft Palate

  • Soh, Byung-Soo;Shin, Hyo-Keun;Kim, Hyun-Gi
    • Speech Sciences
    • /
    • v.12 no.1
    • /
    • pp.27-35
    • /
    • 2005
  • Differential instrumentation for the diagnoses of individuals with Cleft palate has been used to objectively measure speech problems. The Cepstrum Method was used to study the vocal tract transfer function. The vocal tract transfer function and the source spectrum should be considered in the evaluation of nasal resonance. The aim of this study was to collect quantitative data on the acoustic Instrumentation used for evaluating hypernasality. Normal subjects (9 male, 21 female; 37 male children, 20 female children) and individuals with VPI (13 male, 8 female; 16 male children, 9 female) participated in this study. The vowel /i/ was selected to gauge the severances of hypernasality Spectral and Cepstral studies using CSL was used to identify the acoustic characteristics. Cepstrum analysis shows significant differences in quefrency and amplitude. The quefrency of normal groups was shorter than that of the VPI groups, while the amplitude of normal groups was lower than that of the VPI groups. This may have significance in the evaluation 'of nasal resonance.

  • PDF