• Title/Summary/Keyword: gauge condition

Search Result 181, Processing Time 0.021 seconds

Fabrication of Tantalum Nitride Thin-Film as High-temperature Strain Gauges (고온 스트레인 게이지용 질화탄탈박막의 제작)

  • Kim, Jae-Min;Choi, Sung-Kyu;Nam, Hyo-Duk;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.97-100
    • /
    • 2001
  • This paper presents the characteristics of Ta-N thin-film strain gauges as high-temperature strain gauges, which were deposited on Si substrate by DC reactive magnetron sputtering in an argon-nitrogen atmosphere(Ar-(4~16%)$N_2$). These films were annealed for 1 hour in $2{\times}10^{-6}$ Torr vaccum furnace range $500\sim1000^{\circ}C$. The optimized conditions of Ta-N thin-film strain gauges were annealing condition($900^{\circ}C$, 1 hr.) in 8% $N_2$ gas flow ratio deposition atmosphere. Under optimum conditions, the Ta-N thin-films for strain gauges is obtained a high resistivity, $\rho=768.93$ ${\mu}{\Omega}cm$, a low temperature coefficient of resistance, TCR=-84 ppm/$^{\circ}C$ and a high temporal stability with a good longitudinal gauge factor, GF=4.12.

  • PDF

The study on optimum design for shear stress integrated pressure sensor (전단응력형 집적화 압력센서의 최적설계)

  • 주리아;도태성;이종녕;서희돈
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.1
    • /
    • pp.75-81
    • /
    • 1998
  • This paper is to optimize single-element piezoresistor shear stress strain gauge related to aspect ratio of rectangular diaphragm. The shear stress distribution on diaphragm has been simulated by finite-element method(FEM). As simulation results, the maximum sensitivity for strain gauge was appeared at the center of diaphragm with aspect ratio 3, and in along to long edge with the ratio 2. The diaphragm with ratio 2 is not acceptable due to the yield of mask alignment in IC process technology. The optimum condition of diaphragm with respect to good sensitivity was realized in the case of ratio 3. In this case, the area by gauge was 8% of overall size of rectangular diaphragm.

  • PDF

Measurement of the Engine Oil Deterioration of the Diesel Vehicle Using the Engine Oil Level Gauge (엔진오일 레벨게이지를 이용한 디젤 엔진의 오일 열화특성 측정)

  • Kim, Man Jae;Sin, Tae Ho;Lee, Sang Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.1
    • /
    • pp.60-65
    • /
    • 2017
  • We designed and fabricated the engine oil monitoring sensor to measure engine oil deterioration through increased vehicle mileage. Since the condition of the engine oil can be affected by the state of the vehicle and its operating conditions, it should be directly measured and determined in every vehicle. The fabricated sensor has an aluminum parallel capacitor structure that measures capacitance related with the dielectric constant, which is one of the indices of oil deterioration. The size of the capacitor is small enough that it could be easily adapted on the oil level gauge without introducing any change in the design. The fabricated device is installed in the diesel engine to measure the change in capacitance accurately as the vehicle moved from 0 km (new engine oil state) to 11,364 km. The results showed the maximum value at around 5,000 km, and the values plateaued as mileage increased, corresponding with the measurement result of the TAN (Total Acid Number). Based on the results, the condition of the oil must be monitored regularly though oil change is recommended once the vehicle has traveled the distance of around 10,000 km.

Characteristic Analysis of Eddy Current Testing According to the finite Element formulations (와전류탐상의 3차원 유한요소 정식화에 따른 특성 분석)

  • Lee, Hyang-Beom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.384-390
    • /
    • 2005
  • In the numerical analysis of En (eddy current testing) using 3-dimensional FEM (finite element method), MVP (magnetic vector potential) and electric scalar potential are used as variables in conductor region. Three dimensional modeling makes number of unknowns increase, and the degree of freedom of variables also makes number of unknowns increase. Because of this reason, modified UP is used to reduce the number of unknowns. Gauge condition is enforced artificially on existing FEM formulations to insure the uniqueness of MVP. So in this paper the effects of these FEM formulation procedures on ECT are investigated and the appropriate FEM formulation is suggested for accurate ECT simulation.

Dynamic Modeling of PIG Flow in Natural Gas Pipelines (천연가스배관내 피그흐름의 동적모델링)

  • Kim, Sang-Bong;Nguyen, Tan Tien;Yoo, Hui-Ryong;Rho, Yong-Woo
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.241-246
    • /
    • 2001
  • This paper introduces modeling and solution for the dynamics of pipeline inspection gauge (PIG) flow in natural gas pipeline. Without of bypass flow, the dynamic behavior of the PIG depends on the different pressure between the rear and nose parts, which is generated by injected gas flow behind the tail of the PIG and expelled gas flow in front of its nose. With bypass flow, the PIG dynamics also depends on the amount of bypass flow across its body. The mathematical model are derived for unsteady compressible flow of the PIG driving and expelled gas, and for dynamics of the PIG. The bypass flow is assumed to be incompressible with the condition of its Mach number smaller than 0.45. The method of characteristic (MOC) and the Runge-Kutta method are used to solve the system governing equations. The simulation is performed with a pipeline segment in the Korea Gas Corporation (KOGAS) low pressure system, Ueijungboo-Sangye line. The simulation results show that the derived mathematical model and the proposed solution are effective for estimation the dynamics of the PIG with and without bypass flow under given operational condition.

  • PDF

Study on the Strain Measurement in Hot Water (고온수중(高溫水中)에 있어서의 스트레인 측정(測定)에 관(關)한 연구(硏究))

  • Han, Eung-Kyo;Park, Kwang-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.1 no.1
    • /
    • pp.13-21
    • /
    • 1981
  • When we use the strain gauge in the high temperature water, lowering of insulation resistance between test material and gauge is the matter. The lowering makes the measurement unstable and is the primary factor of an error. This study devises the waterproofing method in empirically that has the best insulating property in the hot water($100^{\circ}C$), In this way, we can reach the conclusion that on the condition of a few hours we can measure precisely in the high temperature like normal temperature.

  • PDF

Flow Characteristics of Dispersive ER Fluid Clearance between ER-Valve (ER-Valve 간극내에서 분산계 ER유체의 유동특성)

  • 장성철;염만오;이종두;장성수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1123-1126
    • /
    • 2003
  • In this research 4 plate type ER-Valves which have same surface but different width and length are designed and an experimental apparatus is constructed. With this experimental apparatus, flow rate and pressure drop of ER fluid flowing in ER-Valve are measured by varying electric field strength of ER-valve, and relation between valve types and pressure drop is also experimented. ER fluid is made silicon oil mixed with 40wt% starch having hydrous particles. The pressure drop according to the strength of electric field by differential pressure gauge in the present ER-Valve was used. This test reviewed experiment for the special changes of ER fluids in the steady flow condition.

  • PDF

Fabrication of Ceramic Thin Film Type Pressure Sensors for High-Temperature Applications and Their Characteristics (고온용 세라믹 박막형 압력센서의 제작과 그 특성)

  • 정귀상
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.790-794
    • /
    • 2003
  • This paper describes the fabrication and characteristics of ceramic thin film type pressure sensors based on Ta-N strain gauges for high temperature applications. Ta-N thin-film strain gauges are deposited onto a thermally oxidized Si diaphragm by RF sputtering in an argon-nitrogen atmos[here($N_2$ gas ratio: 8%, annealing condition: 90$0^{\circ}C$, 1 hr.), patterned on a wheatstone bridge configuration, and used as pressure sensing elements with a high stability and a high gauge factor. The sensitivity is 1.097 ~ 1.21 mV/Vㆍkgf/$\textrm{cm}^2$ in the temperature range of 25 ~ 200 $^{\circ}C$ and the maximum non-linearity resistance), non-linearity than existing Si piezoresistive pressure sensors. The fabricated ceramic thin-film type pressure sensor is expected to be usefully applied as pressure and load sensors that os operable under high-temperature.

Evaluation of Field Calibration Test on Rail for Train Wheel Force Measurement

  • Sim, Hyoung-Bo;Yeo, Inho
    • International Journal of Railway
    • /
    • v.8 no.1
    • /
    • pp.1-4
    • /
    • 2015
  • An accurate measurement of the train-track interaction forces is important for track performance evaluation. In the field calibration test as a wheel load measurement process, the calibration system creates a different boundary condition in comparison with that in the train wheel passage. This study aims to evaluate a reliability of the field calibration test in the process of wheel load measurement. Finite element models were developed to compare the deformed shapes, bending moment and shear force profiles on the rail section. The analysis results revealed that the deformed shapes and their associated bending moment profiles on the rail are significantly different in two numerical simulations of the calibration test and the train wheel load passage. However, the shear stress profile on the rail section of the strain gauge installation in the field was almost identical, which may imply that the current calibration test is sufficiently reliable.

A Study on the Development of Sleep Monitoring Smart Wear based on Fiber Sensor for the Management of Sleep Apnea (수면 무호흡증 관리를 위한 섬유센서 기반의 슬립 모니터링 스마트 웨어 개발에 관한 연구)

  • Park, Jin-Hee;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.89-100
    • /
    • 2019
  • Sleep apnea, a medical condition associated with a variety of complications, is generally monitored by standard sleep polysomnography, which is expensive and uncomfortable. To overcome these limitations, this study proposes an unconstrained wearable monitoring system with stretch-fiber sensors that integrate with the wearer's clothing. The system allows patients to undergo examinations in a familiar environment while minimizing the occurrence of skin allergies caused by adhesive tools. As smart clothing for adult males with sleep apnea, long-sleeved T-shirts embedding fibrous sensors were developed, enabling real-time monitoring of the patients' breathing rate, oxygen saturation, and airflow as sleep apnea diagnostic indicators. The gauge factor was measured as 20.3 in sample 4. The maximum breathing intake, measured during three large breaths, was 2048 ml. the oxygen saturation was measured before and during breath-holding. The oxygen saturation change was 69.45%, showing a minimum measurable oxygen saturation of 70%. After washing the garment, the gauge factor reduced only to 18.0, confirming the durability of the proposed system. The wearable sleep apnea monitoring smart clothes are readily available in the home and can measure three indicators of sleep apnea: respiration rate, breathing flow and oxygen saturation.