• 제목/요약/키워드: gas switch

검색결과 105건 처리시간 0.022초

고전압/대전류 투입스위치의 최적설계기술 (Optimized Design Technology of Closing Switch for High Voltage & Current)

  • 서길수;김영배;조국희;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2173-2175
    • /
    • 1999
  • This paper presents the development of closing switch for high voltage and current in detail. Design concept of INPIStron triggered by the gas puffing, voltage hold-off, current capacity, insulating and electrode material, rise time etc, are described. Also for the dptimized design of the electrical triggering switch, pin, ring, wire brush, surface discharge and HCP(Hypo-Cycloidal Pinch) trigger are considered.

  • PDF

High Performance and Low Cost Single Switch Current-fed Energy Recovery Circuits for AC Plasma Display Panels

  • Han Sang-Kyoo;Youn Myung-Joong
    • Journal of Power Electronics
    • /
    • 제6권3호
    • /
    • pp.253-263
    • /
    • 2006
  • A high performance and low cost single switch current fed energy recovery circuit (ERC) for an alternating current (AC) plasma display panel (PDP) is proposed. Since it is composed of only one power switch compared with the conventional circuit consisting of four power switches and two large energy recovery capacitors, the ERC features a simpler structure and lower cost. Furthermore, since all power switches can be switched under soft switching operating conditions, the proposed circuit has desirable merits such as increased reliability and low switching loss. Specifically, there are no serious voltage notches across the PDP with the aid of gas discharge current compensation, which can greatly reduce the current stress of all inverter switches, and provide those switches with the turn on timing margin. To confirm the validity of proposed circuit, its operation and performance were verified on a prototype for 7-inch test PDP.

충전선로를 이용한 Damped Sinusoidal 전자기펄스 발생장치 (A Damped Sinusoidal Electromagnetic Pulse Generator using a Charged Line)

  • 류지헌
    • 한국군사과학기술학회지
    • /
    • 제9권2호
    • /
    • pp.136-142
    • /
    • 2006
  • A damped sinusoidal electromagnetic pulse generator was designed, fabricated and tested. The pulse generator consisted of an oscillator(a spark gap switch and an initially charged low impedance line) and a high impedance antenna. This generator was capable of producing damped sinusoidal pulses at closure of the spark gap switch. A Marx generator was employed to supply the Pulse generator with high voltage pulses. While the pulse generator was provided with the high voltage pulses of 200kV from the Marx generator, its output power was maximized by controlling the pressure of the gas contained in the spark gap switch. The output power of the damped sinusoidal electromagnetic pulse oscillator was 1.3GW and the amplitude of electric field radiated from the pulse generator was 4kV/m at the range of 25m.

고압개폐기용 일체형 복합붓싱 개발 (Development of Single-piece Composite Bushing for High Voltage Switch)

  • 최경선;주종민;이용순;유근양
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1059-1061
    • /
    • 2005
  • The bushing currently applied to pole-mounted type loadbreak switch has porcelain bushing which is connected with the mold cone. This type has potential problems of uncertainty of sealing of the interface part and gas leakage on the connected part between bushing and switch tank due to the weight of the porcelain. The Composite Bushing can solve these problems and also the secondary problem of the potential accident owing to the fragment of the porcelain bushing in breakage due to the outer impact.

  • PDF

이중 스카치 요크 기구를 이용한 접점 개폐 메커니즘의 설계 (Design of Switch Mechanism of Electric Contact Using Double Scotch Yoke Mechanism)

  • 양홍익;안길영;정광영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.804-807
    • /
    • 2005
  • In this paper, a double scotch yoke mechanism for moving simultaneously the fixed contact and moving contact of a gas circuit brake, is proposed and designed to improve the breaking characteristics of the circuit breaker. Firstly, the design parameters of the scotch yoke are kinematically determined from the desired design condition of the circuit breaker. Next, the stroke curve of the moving contact is designed by considering the design parameter and the specified opening characteristics of electric contacts. Based on the scotch yoke and stroke curve, the dynamics of the electric contacts is analyzed using ADAMS model of switch mechanism.

  • PDF

LP 가스 배관의 누출부로부터 점화가능 거리에 관한 연구 (A Study on the Ignition Distance from a Leakage Point of the LP Gas Pipe)

  • 류영돈;김영구;조영도
    • 한국가스학회지
    • /
    • 제21권5호
    • /
    • pp.70-76
    • /
    • 2017
  • "도시가스사업법" 및 "액화석유가스의 안전관리 및 사업법" 관련 기준(KGS Code)에서는 가스배관의 이음부(용접이음매 제외)와 전기설비(전기개폐기, 전기계량기, 전기접속기, 전기점멸기 등)와의 이격거리를 규정하고 있다. "전기설비기술기준"에서도 가스관련 법령과 부합되게 전기설비와 가스배관의 이음부와의 이격거리를 규정하고 있다. "도시가스사업법" 관련 기준의 경우 공급시설 기준과 사용시설 기준에서 규정하는 이격거리가 상이하다. 본 연구에서는 LP가스가 배관의 이음부에서 누출되는 경우 점화 가능 거리를 실증 실험하고, 현재 가스 관련 기준에서 규정하고 있는 전기설비와 가스설비와의 이격거리 기준의 적정성에 대해 검토하였다. 실험 결과 배관의 이음부에서 가스가 누출되는 경우 기준에서 규정하고 있는 30cm 이상의 거리에서도 점화가 가능함을 확인하였다. 따라서, 현재 "도시가스사업법" 및 "액화석유가스의 안전관리 및 사업법" 관련 기준에서 규정하고 있는 가스배관과 전기설비와의 이격거리 기준이 적절한 것으로 판단되었다.

디젤 자동차의 에어컨 사용시 흡기계통 개선에 따른 출력 및 매연 특성에 관한 연구 (A Study on the Power and Smoke Characteristics for the Intake System Improvement using Air Conditioning System in a Diesel Vehicle)

  • 윤영춘;권기린;편훈
    • 동력기계공학회지
    • /
    • 제15권6호
    • /
    • pp.11-15
    • /
    • 2011
  • This study investigated the symptoms of the a reduction in output while driving on the road, or increasing of fumer out exhaust gas on inclined road while working air-conditioner in summer. Notice how the experiment in 2010, the Ministry of Environment(Chapter No. 2010-46), and how the vehicle emissions inspection was carried out. 2500cc Diesel cars used in the study were used and compare to output of engine, exhaust gas, inhalation temperature measurement Inhalation of cold air has not been supplied to all agencies when comparing the results when cold air intake temperature of the supply air-conditioning switch range control from 1 to 4, the temperature drops $98^{\circ}C$ to $78^{\circ}C$. At the momentum of switch level 4, output from 63ps to 66ps after the connection has increased 9.6 percent, the highest concentration of exhaust emissions were reduced by 42.8%. This research can contribute in part to the reduction of exhaust directly supply into the cooling air intake line, doing the output of diesel cars in the summer. In addition, construction equipment and machinery that are currently being used excluding the engine's intercooler cooling of the supply line via a separate output in the summer and help reduce exhaust emissions is expected.

군집화 기법을 이용한 GIS 열화 패턴 연구 (A Study on Degradation Pattern of GIS Using Clustering Methode)

  • 이덕진
    • 한국전기전자재료학회논문지
    • /
    • 제31권4호
    • /
    • pp.255-260
    • /
    • 2018
  • In recent years, increasing electricity use has led to considerable interest in green energy. In order to effectively supply, cut off, and operate an electric power system, many electric power facilities such as gas insulation switch (GIS), cable, and large substation facilities with higher densities are being developed to meet demand. However, because of the increased use of aging electric power facilities, safety problems are emerging. Electromagnetic wave and leakage current detection are mainly used as sensing methods to detect live-line partial discharges. Although electromagnetic sensors are excellent at providing an initial diagnosis and very reliable, it is difficult to precisely determine the fault point, while leakage current sensors require a connection to the ground line and are very vulnerable to line noise. The partial discharge characteristic in particular is accompanied by statistical irregularity, and it has been reported that proper statistical processing of data is very important. Therefore, in this paper, we present the results of analyzing ${\Phi}-q-n$ cluster distributions of partial discharge characteristics by using K-means clustering to develop an expert partial discharge diagnosis system generated in a GIS facility.

고전압 대전류용, Seal-off TVS(Triggered Vacuum Switch) 연구 (Study of Seal-off Triggered Vacuum Switch(TVS) for High Voltage and High Current)

  • 박성수;한영진;김상희;권영건;김승환;박용정;홍만수;남상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1823-1826
    • /
    • 2002
  • The purpose of this experiment was to develope Triggered Vacuum Switch (TVS) for the high voltage and high current. The TVS has an array of rods of alternate polarity in which a fixed gap spacing is maintained between the rods. The cross section of each rod has trapezoidal shape. It consists of electrode, ceramic chamber, getter and trigger. Currently, triggered vacuum switch (TVS) with seal-off has been designed and fabricated at PAL. An experimentation and trigger devices for TVS were designed for testing characteristics of electricity. For making the prototype of TVS, it is developed of fabrication process and fined of electrode material. The fabrication of the TVS is a lot of process which have manufacturing of part, chemical clean, ceramic brazing and metal welding. The fabricated TVS is tested of leak for vacuum, hold-off voltage and conditioning of trigger system. The TVS has pinch-off after it is removed of gas in the TVS and activated of getter in degassing furnace. The prototype TVS tested about 20 kV, 75 kA, 83 ${\mu}s$ with 100 kJ capacitor bank and inductance 5 ${\mu}H$. This paper describes the results of tests and the characteristics of the switch.

  • PDF

가스레인지에 있어서 칼라코딩을 통한 버너와 스위치의 자연적 대응에 관한 연구 (A Study on the Natural Mapping between Burner and Switch of Gas Range by Color coding)

  • 오해춘;홍지영
    • 디자인학연구
    • /
    • 제16권2호
    • /
    • pp.415-424
    • /
    • 2003
  • 사람들은 기억해야할 정보를 머리 속에만 저장하지는 않는다 그러한 정보를 사물에 저장할 수 도 있는데 노만은 이를 세상 속 지식이라고 부른다. 가장 보편적이면서 일반적으로 정보를 사물에 저장하는 방식은 이름표를 부착하는 것이다. 4구 가스레인지에 있어서도 마찬가지로 사용자는 버너와 스위치간의 관계를 기억할 필요 없이 이름표를 보고 이들 관계에 대한 개념모형을 만들도록 가스레인지는 사용자에게 요구하고 있다. 하지만 사용자가 일일이 이름표를 보고 스위치를 조작하는 것은 인지적 스트레스일 것이다. 노만은 이러한 문제를 해결하고자 버너와 스위치가 자연적으로 대응되도록 공간적 유사성을 통한 방법을 제시하였다. 그러나 그의 방법은 현실적으로 주방의 구조에 잘 부합할 수 없어 사용되기가 힘들다. 본 연구에서는 이러한 문제를 해결할 방법으로 칼라코딩을 제안하였다. 버너와 스위치를 칼라로 코딩하면 자연적인 대응이 이루어질 것이라는 관점에서 일반적인 가스레인지를 사용하는 집단과 칼라코딩 된 가스레인지를 사용하는 집단을 자극에 대한 정확성과 반응시간을 기준으로 실험하였다. 실험결과 두 집단간의 과제에 대한 정확도의 차이(f(1,38)=17.892, p<.01)와 반응시간(F(1,38)=6.726 p<.05)의 차이가 유의미하여 칼라코딩의 효과가 있음이 증명되었다. 본 연구를 통해서 칼라코딩이 디자인과정에서 인지적 분류가 중요한 제품들의 디자인에 효과적으로 사용될 수 있음을 제시하고 있다.

  • PDF