• Title/Summary/Keyword: gas storage

Search Result 1,427, Processing Time 0.032 seconds

A Study on the Inner tank Seismic Analysis Model for Calculation of Seismic Forces of LNG Storage Tank (LNG저장탱크 지진력 산정을 위한 내부탱크 지진해석 모델에 관한 연구)

  • Kim, Miseung;Lee, Kangwon;Kim, Junhwi;Yoon, Ihnsoo
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.58-63
    • /
    • 2013
  • LNG(Liquefied Natural Gas) has been considered as the green energy. Thus, the demand of natural gas is keep increasing around the world, and various studies are actively under progress about the LNG storage tank. To calculate the seismic forces of actual LNG storage tank, FEM model has to include inner tank, outer tank, pile and soil to implement the interaction between structure and ground. So, this paper is represent the study about inner tank model of three cases using Malhotra method in EN 1998-4(European Standard). The results of calculation were compared, and the most suitable to inner tank model was suggested.

A Study on the Characteristics of the Work Safety Environment Sensing Module for LNG Storage Tanks (LNG 저장탱크용 작업안전 환경 센싱 모듈의 특성연구)

  • Park, Byong Jin;Kim, Min Sung
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.2
    • /
    • pp.189-196
    • /
    • 2022
  • We have developed an embedded based environment sensing module with high-resolution temperature, humidity and gas sensors to detect gas leakage under the condition of LNG injection. The developed sensing module have linearity with gas concentration. We have confirmed the developed sensing module could detect LNG gas concentration of 5 cmol/mol and 15 cmol/mol, which are gas concentration at risk of explosion. The response time of the developed module was fast within 8 seconds. Therefore it can be used to detect LNG gas leakage.

A Study on the District Community Cooling System using LNG Cold Energy (LNG 냉열이용 지역집단 냉방시스템에 대한 연구)

  • Kim, Chung-Kyun;Kim, Seung-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.27-30
    • /
    • 2010
  • This paper presents the system design process of district community cooling system using LNG cold energy. The newly developed LNG cooling system includes several heat exchangers, LNG storage tank, thermal mass storage tank, several cold energy storage tanks, gas air-conditioners, compressors, constant pressure regulators, cold energy and hot energy supply pipes. In addition, the gas air-conditioner system is installed to supply not sufficient cold energy due to low level of city gas consumptions during a summer period. This system design is very effective and safe to supply cold energy mass of fresh air by exchanging two thermal masses of an air and 200kcal/kg cold energy of LNG. The district community cooling system with LNG cold energy does not produce CO2 and freon gases in the air.

Effect of CA Storage Conditions on the Internal Breakdown of Fuji Apple Fruits under CA Storage (Fuji 사과의 CA저장중 저장조건이 과육갈변에 미치는 영향)

  • 이주백;최종욱
    • Food Science and Preservation
    • /
    • v.4 no.3
    • /
    • pp.227-235
    • /
    • 1997
  • The internal breakdown of Fuji apple during CA storage classified as watercore breakdown, low temperature breakdown and CO2 injury. This study was undertaken to investigate the watercore breakdown injury factors of Korean Fuji apple during CA storage. The development of internal breakdown was more increased with the larger size, the later harvest time and the hither CO2 gas level. But in internal breakdown fruit of the titratable acidity and soluble solid decreased significantly, the pH of fruit juice and the production of carbon dioxide was greatly increased. The best gas levels of CA storage was 2% oxygen and 3% carbon dioxide. Thus, the predictable parameters of internal breakdown of fruit were increase in pH on decrease titratable acidity within 2 months of CA storage, increase carbon dioxide. So, it was found that the best CA sotrage for internal breakdown control of fruit during CA storage was delayed CA storage methods after low temperature storage immediate harvest of apple and than took a step. The delayed CA storage after low temperature storage for 2 months was more effective in the prevention of development of internal breakdown than immediate CA storage after harvest.

  • PDF

Problem Solving for LPG Storage Tank using RPS-TRIZ (RPS-TRIZ를 활용한 LPG 저장탱크 문제해결)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Lim, Ju-Yeon;Kim, In-Gyu;Jeong, Shin-Young
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.5
    • /
    • pp.7-12
    • /
    • 2011
  • LPG(Liquefied Petroluem Gas) Vehicles in metropolitan area being applied to improve air quality and have been proven effective for the reduction of air pollution. These gas stations are required to safe the storage tank because of possibility of causing huge loss of life and property. While storage tanks above ground have potential risk of explosion if fire breaks out and those under-ground are difficult to inspect due to poor accessibility neither above nor under-ground tank can serve us well. This study used the RPS-TRIZ (Rapidly Problem Solving-Teoriya Resheniya Izobretatelskikh Zadatch) technique and suggested the use of under-ground containment storage tank as a solution for safety issues and safety inspection.

Development and Its Application of a Discrete Fracture Flow Model for the Analysis of Gas-Water Transient Flow in Fractured Rock Masses Around Storage Cavern (지하저장공동 주변 불연속 암반에서의 가스-물 천이유동해석을 위한 개별균열 유동모델의 개발 및 응용)

  • 나승훈;성원모
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.705-712
    • /
    • 2000
  • The fluid generally flows through fractures in crystalline rocks where most of underground storage facilities are constructed because of their low hydraulic conductivities. The fractured rock is better to be conceptualized with a discrete fracture concept, rather continuum approach. In the aspect of fluid flow in underground, the simultaneous flow of groundwater and gas should be considered in the cases of generation and leakage of gas in nuclear waste disposal facilities, air sparging process and soil vapor extraction for eliminating contaminants in soil or rock pore, and pneumatic fracturing for the improvement of permeability of rock mass. For the purpose of appropriate analysis of groundwater-gas flow, this study presents an unsteady-state multi-phase FEM fracture network simulator. Numerical simulation has been also conducted to investigate the hydraulic head distribution and air tightness around Ulsan LPG storage cavern. The recorded hydraulic head at the observation well Y was -5 to -10 m. From the results obtained by the developed model, it shows that the discrete fracture model yielded hydraulic head of -10 m, whereas great discrepancy with the field data was observed in the case of equivalent continuum modeling. The air tightness of individual fractures around cavern was examined according to two different operating pressures and as a result, only several numbers of fractures neighboring the cavern did not satisfy the criteria of air tightness at 882 kPa of cavern pressure. In the meantime, when operating pressure is 710.5 kPa, the most areas did not satisfy air tightness criteria. Finally, in the case of gas leaking from cavern to the surrounding rocks, the resulted hydraulic head and flowing pattern was changed and, therefore, gas was leaked out from the cavern ceiling and groundwater was flowed into the cavern through the walls.

  • PDF

A Development of Representative Condition Evaluation Standard for LNG Storage Tank Structures (LNG 저장탱크 구조물의 종합적 상태평가기준 개발)

  • Kim, Jung-Hoon;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.44-51
    • /
    • 2018
  • As the LNG storage tank is aged, if there is a crack in the outer wall concrete or corrosion of the reinforcing steel, there is a risk of a major accident such as collapse of the structure depending on the type and degree of damage. Since 2014, LNG storage tanks have undergone precise safety diagnosis and safety inspection has been carried out. The condition evaluation criteria for each component have been revised and applied in January 2016. The condition evaluation standard is to evaluate the status of storage tanks based on the appearance survey and material test results of LNG storage tanks and it is important for maintenance. In addition, the representative condition evaluation standard that shows the comprehensive state of each LNG storage tank is important in maintenance, but the related standard for LNG storage tank outer concrete is not available in Korea and abroad, and development of the condition evaluation standard is necessary. In this paper, we examined the structural characteristics of LNG storage tanks, analyzed the status of the condition evaluation criteria for each member, and developed a comprehensive status rating system by weighting the members. We used the AHP(Analytic Hierarchy Process) technique and developed a representative conditon evaluation criteria through surveys of professional organizations.

Case Study on Seepage Analysis and Countermeasure Against the Seepage Flow of In-ground LNG Storage Tank (LNG 지하저장탱크의 침투해석 및 용수 대책공법에 대한 사례분석)

  • 신은철;오영인;이상혁
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.65-72
    • /
    • 2001
  • Since Pyoungtaek thermal power plant began using natural gas in 1986, the annual using volume has rapidly increased and reached 12.7 million tons in 1999. When the natural gas is cooled to a temperature of approximately -162$^{\circ}$C at atmospheric pressure, it condenses to a liquid called liquefied natural gas(LNG). LNG has a special characters such as odorless, colorless, non-corrosive, and non-toxic. So, LNG storage tank, tanker ship, transfer pipelines are required the special storage and transportation systems and technology. The presently operating LNG terminals are Pyongtaek and Inchon terminals. A total of 19 above-ground LNG storage tanks(100 thousand ㎘ grade) are currently in operation with a sendout capacity of 4,360tons/hour. To meet the growing domestic demand of LNG supply, the Inchon receiving terminal is expanding(six in-ground tank) and constructing a third LNG terminal at Tongyong. In this paper, case study on seepage analysis and countermeasure against increasing the seepage volume of in-ground LNG storage tank excavation work is reported. The results of an additional seepage analysis are presented to verify the design seepage volume of assumption section and seepage volume after curtain-grouting in the slurry wall.

  • PDF

Three-dimensional Graphene Aerogels for Electrochemical Energy Storage

  • Yun, Sol;Park, Ho Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.485.1-485.1
    • /
    • 2014
  • In this research, we report the synthesis of three-dimensional (3D) hierarchical porous graphene aerogels (hpGAs) for application to electrochemical energy storage. For electrochemical systems, the specific capacitance is a key parameter to evaluate the characteristics of electrode materials. By taking full advantage of large surface area, 3D hpGAs would achieve the larger specific capacitance over rGO film and GAs. Microscopic structures and topologies of hpGAs were investigated using field emission scanning electron microscopy and transmission electron microscopy. X-ray photoelectron spectroscopy was used to determine the chemical compositions of rGO film, GAs, and hpGAs. Raman spectra were recorded from 100 to 2500 cm-1 at room temperature using a Raman spectroscopy equipped with a ${\times}100$ objective was used. The specific area and pore distribution of GAs and hpGAs were obtained using a Brunauer-Emmett-Teller apparatus.

  • PDF

Cold Energy Storage System Using Direct Contact Heat Transfer (직접 접촉식을 이용한 빙축열 시스템)

  • Lee, Y.P.;Yoon, S.Y.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.247-258
    • /
    • 1994
  • In this study, experimental investigations to find cold energy storage performance have been made for two different temperatures at condenser. Temperatures at inlet and outlet of condenser were measured to calculate global heat transfer coefficient of direct contact method in our cold energy storage system. Also storage performance by direct contact method was compared with that of Ice-On-Coil type ice storage which was calculated by analytic solution. Results show that, in the case of $-8.0^{\circ}C$ at condenser inlet, heat transfer coefficient of direct contact method is 3.25 times higher than that of conventional method and COP of system is improved by using R141b as refrigerant which produces gas hydrate and has higher phase change temperature than $0.0^{\circ}C$.

  • PDF