• Title/Summary/Keyword: gas measurement method

Search Result 643, Processing Time 0.026 seconds

Facilitated Transport Separation of Carbon Dioxide Using Aminated Polyetherimide Membranes (아민화된 폴리이서이미드 막을 이용한 이산화탄소의 촉진수송분리)

  • Kwon, Se Hwan;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.25 no.3
    • /
    • pp.248-255
    • /
    • 2015
  • Aminated polyetherimide membrane synthesized in the laboratory according to amine ratio was used for measurement of gas permeability, diffusivity, and solubility about carbon dioxide, nitrogen, methane, oxygen, and sulfur dioxide with Time-lag method at room temperature. Generally, gas permeability is totally decreased because the more amination rate reacted to the main chain of amine groups, the more intermolecular space became narrow. However, gas permeability of sulfur dioxide was increased due to combination of sulfur dioxide and amine groups have acid and base properties respectively. Diffusivity and solubility of dry gas are totally decreased excluding sulfur dioxide as increasing amination rate. In case of sulfur dioxide, however, diffusivity as well as solubility was increased as increasing amination rate. Selectivity of carbon dioxide/nitrogen showed 60 when amination rate was 3. In case of humid gas, gas permeability of carbon dioxide was 70 barrer when relative humidity showed 100, and selectivity with nitrogen approximately showed 18.

Study on the Treatment of Hydrogen Chloride Gas used in Semiconductor Process by using Gas Adsorption Agents such as Zeolite Resins, ZnO, and AgMnO3 (제올라이트 수지 및 ZnO, AgMnO3 등의 무기흡착제를 이용한 반도체 공정에서 사용되는 염산가스의 처리 및 측정에 관한 연구)

  • Park, Jeong-Jun;Lim, H.B.;Hwang, Cheong-Soo
    • Analytical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.218-225
    • /
    • 2003
  • Hydrogen Chloride is among the most problematic gases used in semiconductor process. It raises serious environmental and health problems due to its extreme toxicity. This study is to develop a method to effectively remove hydrogen chloride gas during the process by using various types of inorganic gas adsorption agents, which have not been attempted in the conventional methods. The removal efficiency of the gas was both qualitatively and quantitatively measured by a FT-IR spectrophotometer. The whole device for the measurement has been designed and built in our lab. The removal efficiencies of hydrogen chloride gas were compared between those tested resins; zeolite A, modified AgA zeolite, ZnO, and $AgMnO_3$. The experimental result revealed that ZnO showed the best efficiency that had removed 0.067 g of HCl per 1 g of the resin used.

A Research on the Promotion of AMI Supply by the Development of 1:N Mounted Remote Meter Reading Device (1:N HUB 기능을 가진 원격검침 단말기 개발에 따른 AMI 보급 추진 방안 연구)

  • Lee, Hyoung-Min;Kim, Min-Gi;Choi, Eun-Il;Yoon, Chan-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.1-6
    • /
    • 2021
  • In this study, we developed AMI terminals of 1 (reader): N (small transmitter). Currently, the government is focusing on the Gas AMI demonstration project to advance the outdated metering system of the urban gas industry, led by the government-sponsored ministries. The supply of gas AMI meters has the advantage of resolving uncertainties in privacy violations and measurement information and preparing for consumer safety through gas leakage detection. In the case of existing AMI meters, readers and transmitters were 1:1 methods, while this technology can be extended to multiple generations with a 1:N method, and a technology that can extend battery life by implementing a low-power design is applied. We hope that this research will contribute to the gas AMI supply project in the future.

Measurement of Bubble Size in Flotation Column using Image Analysis System (이미지 분석시스템을 이용한 부선컬럼에서 기포크기의 측정)

  • An, Ki-Seon;Jeon, Ho-Seok;Park, Chul-Hyun
    • Resources Recycling
    • /
    • v.29 no.6
    • /
    • pp.104-113
    • /
    • 2020
  • Bubble size in froth flotation has long been recognized as a key factor which affects the bubble residence time, the bubble surface area flux (Sb) and the carrying rate (Cr). This paper presents method of bubble size measurement, relationship between operating variables and gas dispersion properties in flotation column. Using high speed camera and image analysis system, bubble size has been directly measured as a function of operating parameters (e.g., superficial gas rate (Jg), superficial wash water rate (Jw), frother concentration) in flotation column. Relationship compared to measured and estimated bubble size was obtained within error ranges of ±15~20% and mean bubble size was 0.718mm. From this system the empirical relationship to control the bubble size and distribution has been developed under operating conditions such as Jg of 0.65~1.3cm/s, Jw of 0.13~0.52cm/s and frother concentration of 60~200ppm. Surface tension and bubble size decreased as frother concentration increased. It seemed that critical coalescence concentration (CCC) of bubbles was 200ppm so that surface tension was the lowest (49.24mN/m) at frother concentration of 200ppm. Bubble size tend to increase when superficial gas rate (Jg) decreases and superficial wash water rate Jw and frother concentration increase. Gas holdup is proportional to superficial gas rate as well as frother concentration and superficial wash water rate (at the fixed superficial gas rate).

A Study on Speedy Water Content Measurement Method for Soils (흙의 급속 함수비 측정방법에 관한 연구)

  • Park, Sung-Sik;Kim, Ju-Young;Lee, Sae-Byeok
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.1
    • /
    • pp.57-65
    • /
    • 2017
  • During a construction of embankment, sub base, or retaining wall backfill, the speedy measurement of water content is necessary. In this study, a test method for field determination of water content of soil by the calcium carbide gas pressure (speedy water content measurement method) was evaluated for its reliability and accuracy. Dry oven and microwave oven methods were also used for water content measurement. In the test, weathered granite and Nakdong River sand in the site and kaolinite were used for water content measurement. The mass of 20, 22, 24, 26, 28, and 30 g of soil was respectively tested for 1, 3, and 5 min. The effect of each sample on water content was compared one another and analyzed. As the mass and testing time increased, the water content increased. The amount of soil was more important factor than testing time for the speedy water content measurement. In order to obtain similar result to that of dry oven method, 3 min of testing time with 24 g of soil was necessary for weathered granite classified as SM and 3 min with 30 g for Nakdong River sand classified as SP. For Nakdong River sand with 20-50% of kaolinite, the water content by speedy measurement increased as the clay content increased.

Partial Conductivity of YSZ Doped with 10 mol% $TiO_2$

  • Kobayashi, Kiyoshi;Kai, Yukiharu;Yamaguchi, Shu;Kawashima, Tsuyoshi;Iguchi, Yoshiaki
    • The Korean Journal of Ceramics
    • /
    • v.4 no.2
    • /
    • pp.114-121
    • /
    • 1998
  • Using Hebb-Wagner's asymmetric cell, partial conductivities of holes and electrons in yttria stabilized zirconia doped with 10 mol% TiO2 have been estimated by a dc polarization measurement. The current interrruption method and ac impedance measurements have been also made to evaluate the ionic conductivity and to examine the consistency of the partial conductivities. Partial conductivities of electrons(σn) and holes (σp) were found to be pro-peortional to -1/4 and 1/4 power of partial pressure of oxygen gas, respectively, except for σn at reducing conditions. In comparison with 5 mol% doped YSZ, σn was found to increase with the increase of TiO2 concentration, but σp stayed at almost a constant value.

  • PDF

Preliminary Study of Micro Cold Gas Thruster (마이크로 콜드 가스 추력기의 선행 연구)

  • Seonghwan Moon;Hwayoung Oh;Hwanil Huh
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.2
    • /
    • pp.54-61
    • /
    • 2004
  • Miniaturization of subsystems including propulsion systems is recent trends in spacecraft technology. Small space vehicle propulsion is not only a technological challenge of a scaling system down, but also a combination of fundamental flow/combustion constraints. In this paper, physical constraints of micronozzle for cold gas micro-thruster are reviewed and discussed. Method to measure small thrust are also described.

Properties of GZO thin films prepared by oxygen gas flow rate (산소 분압비에 따라 제작된 GZO 박막의 특성)

  • Jung, Yu-Sup;Kim, Kyung-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.336-336
    • /
    • 2010
  • Ga doped ZnO (GZO) transparent conductive films were deposited on the glass substrates at room temperature by facing target sputtering (FTS) method. The sputtering targets were 100 mm diameter disks of GZO($Ga_2O_3$ 3.w.t%) and Zn metal. The GZO thin films were deposited as a various $PO_2$ (oxygen gas content). Base pressure was $2{\times}10^{-6}$torr, and a working pressure was 1mTorr. The properties of thin films on the electrical and optical properties of the deposited films were investigated by using a four-point probe, a Hall Effect measurement and an UV/VIS spectrometer. The minimum resistivity of film was $6.5{\times}10^{-4}$[$\Omega$-cm] and the average transmittance of over 80% was seen in the visible range.

  • PDF

Improving Breakdown Voltage Characteristics of GDAs using Trigger Voltage

  • Lee, Sei-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.646-652
    • /
    • 2010
  • This paper investigates a method to improve the breakdown voltage characteristics of a gas discharge arrester (GDA) for a surge suppressor. The middle electrode is inserted between two terminal electrodes. Voltage application to the electrode synchronized and amplified by the impulse voltage decreases spark overvoltage from 45% to 57.6%. The decrease is caused by higher voltage slope, as opposed to applied impulse voltage (by 5.5 to 6.2 times). In addition, the GDA model using ATP-Draw was used to analyze the operation characteristics of GDAs. The test and simulation results agree to within 2% when the trigger source was used.

The Analysis of PD Signal using Neural Network (신경회로망을 이용한 부분방전 신호의 패턴분석)

  • 김종서;박용필;천민우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.567-571
    • /
    • 2004
  • Recently, GIS(Gas Insulated Switchgear) has been recognizing of importance on development of diagnosis technique which is happened problem on confidence for a long time use. Therefore, the measurement and analysis of PD with prior phenomenon of insulation breakdown is used many method of diagnosis for GIS. In this paper, we simulate trouble condition in DS and analysis trouble signal to use electrical and mechanical methods, interpretation of detected signal has analysed with to use ø-q-n pattern and neural network. For this analysis, we have used the induction and AE(acoustic emission) sensors. For the simulation experiment, we make DS for 170 KV GIS and analyze the classification and characteristics of detected signals with the application of neural network algorithm.