• 제목/요약/키워드: gas insulation

검색결과 537건 처리시간 0.045초

초고속 Marx Generator의 N2, SF6, N2-SF6 혼합가스에 따른 출력 특성 연구 (Ultra fast Marx Generator of N2, SF6, N2-SF6 Mixture Gas based on Research Output Characteristics)

  • 두진석;한승문;허창수;최진수
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1850-1855
    • /
    • 2010
  • The application field of the pulse power is very wide. Recently, Pulse power technologies take a large place in several applications. Then, many civil and military applications proceed. Marx generator is widely used in high voltage applications. Marx generator is widely used in high voltage applications, such as eletromagnetic wave and power lasers. This paper, we described about the high voltage pulse generator. A compact size high voltage pulse generator with nanosecnd rise time has been fabricated and investigated experimentally. The marx generator has 2 stages. Each stage was constructed one charging capacitor, two electrodes and one charging resistor. A inductance structure is used in order to improve the switching performances fo the whole generator. The experiments of rise time in pure gas and mixtures of gases were described. We tested the Marx generator at different insulation gas. the results show that the dielectric strength of the $N_2-SF_6$ mixture was significantly increased compared with pure nitrogen gas. The experimental results show that the rise time characteristics of the Marx generator can be controlled through varying insulation gas.

N2-O2 혼합가스에 따른 Teflon의 절연파괴특성 (Breakdown Characteristics of Teflon by N2-O2 Mixture gas)

  • 최은혁;최병숙;박숭규
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.69-74
    • /
    • 2018
  • 산업사회의 발달과 더불어 신뢰성 높은 양질의 전기에너지와 운전 및 보수의 간편화, 계통 운용의 신뢰성, 안전성 확보가 요구되고 있다. 본 논문에서는 각종 전력설비에서 SF6을 대체하여 사용되고 있는 친환경절연제 $N_2-O_2$ 혼합가스 고체 절연물의 절연파괴특성과 고체절연재로 사용되고 있는 테프론의 연면절연특성을 압력에 따른 특성을 확인하였다. 대기와 비슷한 성분비 일 때 상대적으로 절연파괴특성이 테프론의 연면절연특성이 안정화되며, Paschen 법칙에 의해 평등전계에 가까운 전극중의 기체의 절연파괴전압은 압력에 비례하여 높아지고 있음을 실험을 통하여 확인하였다. 연면절연파괴전압은 압력에 따라 선형적으로 증가하였으며, 혼합가스의 $O_2$ 가스 혼합비에 따라 절연파괴전압의 차이가 발생하였다. 이는 $O_2$ 가스의 전기적 부성기체의 영향과 분자 간 충돌거리에 의해 연면절연파괴전압이 달라졌고, 본 연구에서 분자 간 충돌거리의 영향이 더 크게 작용하였다. 연면절연특성에 따른 테프론에 적용 가능한 절연파괴전압 관계식을 산출하였다. 이러한 결과는 전력설비의 절연설계 시 기초자료로 사용될 수 있을 것이라 생각된다.

증발가스 재액화 드럼의 단열구조에 관한 실험적 연구 (The Experimental Study of Insulation Structure for BOG Re-liquefaction Drum)

  • 김익수;정영준
    • 한국가스학회지
    • /
    • 제25권1호
    • /
    • pp.7-13
    • /
    • 2021
  • 재액화 드럼은 과냉각된 LNG를 증발가스에 직접 분사하기 위해 상부에 스프레이 노즐을 설치하고, 기액 분리가 용이하도록 데미스터를 설치한 제품으로, 소형 재액화 설비의 재액화 효율을 높이기 위해 개발한 제품이다. 드럼의 상온 내압기밀시험에서는 설계압력의 1.5배 이상의 압력에서도 누설(Leak)이 없었으나, 단열성능시험 중 온도변화에 따른 수축/팽창으로 인해 볼트풀림 현상이 발생하였다. 제품의 지속적인 사용을 위해 플랜지 결합부의 단열 시공은 탈부착이 가능하도록 개발하였으며, 기존 단열과의 열침입량 비교 결과 드럼 내 유입 유량 대비 매우 미미함을 확인하였다.

유기질 단열재 열전도율의 경시 변화 (Changes in the Thermal Conductivity of Organic Insulators over Time)

  • 김해나;홍상훈;정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.219-220
    • /
    • 2023
  • The thermal conductivity of the insulation material has a great influence on the heat transmission coefficient, which is currently used for energy evaluation of buildings. The thermal conductivity of insulation changes with changes in the environment, such as humidity and ultraviolet rays, and can be expected to with the passage of time. But there is a lack of data on this, so this study measured the thermal conductivity of organic insulation according to environmental conditions and time, As a result, in the case of XPS, the thermal conductivity value increased over time, which is estimated to be due to the decrease in insulation performance as the foaming gas escapes to the outside, and in the case of PIR class2 No.2 and PIR noncombustible, the increased thermal conductivity value is similar, but in the case of PIR class2 No.2, a relatively moderate increase can be seen, and in the case of PIR noncombustible, a large increase is seen at the beginning, which is judged to be due to the decrease in insulation performance as the internal foaming gas is substituted with air from the outside.

  • PDF

볼츠만 방정식에 의한 $CF_4$ 분자가스의 전리 및 부착계수에 관한 연구 (The study of ionization and attachment coefficients in $CF_4$ molecular gas by Boltzmann equation)

  • 송병두;하성철;전병훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.628-631
    • /
    • 2004
  • A tetrafluoromethane$(CF_4)$ is most useful gas in plasma dry etching, because it has a electron attachment cross-section. therefor it is important to calculate transport coefficients like electron drift velocity, ionization coefficient, attachment coefficient, effective ionization coefficient. and critical E/N. The aim of this study is to get these transport coefficients for information of the insulation strength and efficiency of etching process. Electron transport coefficients in $CF_4+Ar$ gas mixture are simulated in range of E/N values from 1 to 250 [Td] at 300[K} and 1 [Torr] by using Boltzmann equation method. The results of this method can be important data to present characteristic of gas for plasma etching and insulation, specially critical E/N is a data to evaluate insulation strength of a gas. and is presented in this paper for various mixture ratios of $CF_4+Ar$ gas mixture.

  • PDF

친환경 절연가스 중 연면절연성 향상을 위한 고체유전체의 유전율과 지름에 따른 연면방전특성 연구 (A Study on the Surface Discharge Characteristics by Dielectric Constant and Diameter of Solid Dielectrics to Improve Surface Dielectric Strength in Eco-Friendly Insulation Gas)

  • 임동영;민경준;박혜리;최은혁;최상태;박원주;이광식
    • 조명전기설비학회논문지
    • /
    • 제27권1호
    • /
    • pp.85-91
    • /
    • 2013
  • This paper studied surface discharge characteristics by a dielectric constant and diameter of solid dielectrics in $N_2/O_2$ mixture gas. Applied electric field strength at $N_2/O_2$ mixture gas was changed from the dielectric constant and diameter of the solid dielectrics, and insulation performance of the $N_2/O_2$ mixture gas determined surface discharge voltage. In each of the diameter at the solid dielectrics, the surface discharge voltage was increased by lengthening surface distance, whereas increasing rate of the surface discharge voltage was different from gas pressure. Thus, In this paper, main factors of surface discharge are as follows. 1) Insulation performance of $N_2/O_2$ mixture gas, 2) Dielectric constant of solid dielectrics, 3) Surface discharge path. It was clear that the surface discharge voltage depend on the main factors. These results will be applied to useful data for an eco-friendly composite insulation design.

페놀 폼 단열재의 연기밀도 및 가스유해성 평가 (Evaluation of Smoke Density and Noxious Gas for Phenol Foam Insulation)

  • 박형주
    • 한국안전학회지
    • /
    • 제25권1호
    • /
    • pp.38-43
    • /
    • 2010
  • The smoke density and noxious gas for phenol foam and polyurethane foam were measured according to test methods in ASTM E 662 and KS F 2271. It was observed that phenol foam had the possibility of application for sandwich panel and board compared with polyurethane foam. In the experimental results, phenol foam showed comparatively excellent property than polyurethane foam in smoke density and noxious gas. The polyurethane foam showed comparatively high smoke density and didn't meet the evaluation standard of noxious gas in KS F 2271. From the experimental results of smoke density and noxious gas, it can be said that phenol foam has both comparatively good safety and high possibility of application than polyurethane foam in the building fire of sandwich panel structure because of lower smoke density and noxious gas.

$SF_6$ 상태에 따른 절연파괴전압 비교분석에 관한 연구 (The analysis & comparative method on the breakdown voltage in $SF_6$)

  • 최은혁;윤대희;박광서;박원주;주재현;최상태;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.335-338
    • /
    • 2004
  • In this paper the experiments of insulation characteristics by temperature change of $SF_6$ gas and insulation characteristics about liquid $SF_6$ in GIS(Gas Insulated Switchgear) were described. From this result, at low temperature, the breakdown voltage was increased with a drop of temperature and an increase of the inner pressure in GIS. The ability of insulation in liquid $SF_6$ was higher than that of the highly pressurized $SF_6$ gas. A liquid $SF_6$ discharge characteristics was caused by bubble formed evaporation of liquid $SF_6$ and bubble when high voltage apply to electrode. Corona was happened to weak bubble and was proceed to new bubble breakdown.

  • PDF

액체 $SF_6$의 정기포현상(正氣泡現像) (The positive bubble effect in liquid $SF_6$)

  • 최은혁;이재학;박광서;김종환;김이국;박원주;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.151-154
    • /
    • 2005
  • In this paper the experiments of insulation characteristics by temperature change of $SF_6$ gas and liquid $SF_6$ in model GIS(Gas Insulated Switchgear) were described. From this results, the breakdown voltage was increased with a drop of temperature and an increase of the inner pressure in model GIS. The ability of insulation in liquid $SF_6$ was higher than that of the highly pressurized $SF_6$ gas. A liquid $SF_6$ discharge characteristics was caused by bubble formed evaporation of liquid $SF_6$ and bubble caused by high electric emission. It is considered that these result are fundamental data for electric insulation design of superconductor and cryogenic application machinery which will be studied and developed in the future.

  • PDF

온도저하에 따른 $SF_6$의 연면파괴특성 (The Surface Flashover Characteristics of $SF_6$ with a variation of Temperature)

  • 최은혁;이상호;장승호;임창호;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1398_1399
    • /
    • 2009
  • In this paper, insulations characteristics by temperature changes(+30~-40[$^{\circ}C$]) of $SF_6$ gas in the experimental chamber were studied. From this result, The breakdown characteristics classify the gas & liquid coexisted stage of voltage value increases & much deviation and the $V_B$ low stage as the interior of chamber gets filled with mixture of $SF_6$ that are not liquefacted and remain ing air which couldn't be ventilated. In addition the ability of insulation of liquid $SF_6$ was higher than that of the highly pressurized $SF_6$ gas. In this research, we want to provide the base data on designing insulation of high-temperature superconductor and the cryogenic equipments by investigating the insulation characteristics of $SF_6$.

  • PDF