• Title/Summary/Keyword: gas insulation

Search Result 540, Processing Time 0.024 seconds

Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings (공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석)

  • Lee, Han-Sol;Kim, Seo-Hun;Kim, Jonghun;Kim, Jun-Tae;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.

Arc Generation Facility with Auxiliary Current Source Using LC Resonance Circuit (보조 전류원 커패시터 뱅크를 가지는 LC공진회로를 이용한 아크발생 실험장치에 관한 연구)

  • Kang, J.S.;Park, H.T.;Lee, B.W.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1054-1056
    • /
    • 1999
  • It is necessary to install the arc generation facility to obtain the important technology for the design of breakers and switches, and the improvement of their performance and reliability. With this facility it is possible to study the characteristics of Arc in air/gas/vacuum insulation environment. The arc generation facility briefly consists of capacitor bank which can charge enormous energy, an air-core reactor, and several measurement equipments. This facility can simulates the arc phenomena in breakers and switches by means of generating high currents. In order to the protect electrode damage during the arcing time in arc extinguishing chamber, we installed auxiliary current source in addition to main capacitor bank, This auxiliary current source produces relatively small arc between electrodes before high current generation by main capacitor bank. Therefore it is possible to observe and measure the arcing phenomenon without damage of electrodes.

  • PDF

A Comparative Study on Mechanical Behavior of Low Temperature Application Materials for Ships and Offshore Structures (선박 및 해양구조물용 극저온 재료의 기계적 거동 특성)

  • Park, Woong-Sup;Kang, Ki-Yeob;Chun, Min-Sung;Lee, Jae-Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.3
    • /
    • pp.189-199
    • /
    • 2011
  • Austenite stainless steel(ASS), aluminum alloy and nickel steel alloy are the most widely used in many cryogenic applications due to superior mechanical properties at low temperature. The Face-Centered Cubic(FCC) and Hexagonal Close-Packed(HCP) materials are used for the primary and secondary insulation barrier of Liquefied Natural Gas(LNG) carrier tank and various kinds of LNG applications currently. In this study, tensile tests of ASS, aluminum alloy and nickel steel alloy were carried out for the acquisition of quantitative mechanical properties under the cryogenic environment. The range of thermal condition was room temperature to $-163^{\circ}C$ and strain rate range was 0.00016/s to 0.01/s considering the dependencies of temperatures and strain rates. The comprehensive test data were analyzed in terms of the characteristics of mechanical behavior for the development of constitutive equation and its application.

Design of Adiabatic Demagnetization Refrigerator for Hydrogen Re-Liquefaction (수소 재액화용 단열 탈자 냉동기의 설계)

  • Park, Ji-Ho;Kim, Young-Kwon;Jeong, Sang-Kwon;Kim, Seok-Ho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.53-59
    • /
    • 2012
  • Adiabatic demagnetization refrigerator (ADR) for hydrogen re-liquefaction operating between 24 K and 20 K has been designed. $Dy_{0.9}Gd_{0.1}Ni_2$, whose Curie temperature is 24 K, is selected as a magnetic refrigerant. The magnetic refrigerant powder is sintered with oxygen-free high purity copper (OFHC) powder to enhance its effective thermal conductivity as well as to achieve relatively high frequency. A perforated plate heat exchanger (PPHE) operated with forced convection is utilized as a heat switch. The forced convection heat switch is expected to have fast response relative to a conventional gas-gap heat switch. A conduction-cooled high Tc superconducting (HTS) magnet is employed to apply external magnetic field variation on a magnetic refrigerant. $2^{nd}$ generation GdBCO coated conductor HTS tape with Kapton$^{(R)}$ insulation (SUNAM Inc.) will be utilized for the HTS magnet. The magnetization and demagnetization processes are to be achieved by the AC operation of the HTS magnet. The designed magnetic field and target ramp rate of the HTS magnet are over 4 T with 180 A and 0.4 T/s, respectively. AC loss distribution on HTS magnet is theoretically estimated.

Detection of Partial Discharge Acoustic Signal Using the Optical Fiber Interferometric Sensor (광섬유 간섭계 센서를 이용한 부분방전 음압 측정)

  • 이종길;박윤석;이준호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.7
    • /
    • pp.614-623
    • /
    • 2002
  • In this paper, it was manufactured an interferometric optical fiber sensor and measured partial discharge acoustic signal caused by defect of power facilities such as power cables, transformers and gas insulation. Acrylic and aluminium mandrels wound with fiber-optic were chosen as optical fiber sensor, Sagnac and Mach-Zehnder interferometers were chosen to detect discharge acoustic signals. The two fiber optic interferometers were identified by using the PZT. Discharge experimentation set in the discharge imitation cell in oil tank and the discharge phenomena was generated. Based on the experimental result, to detect the discharge acoustic signal, Sagnac interferometer can detect stably the acoustic signal than the Mach-Zehnder interferometer. It is shown that Sagnac optical fiber sensor can detect the discharge acoustic signals effectively.

A Comparison of Thermal Performance of Double Low-E Glazing Window according to Various Material (더블로이유리 적용 창호의 구성요소에 따른 단열성능 비교 실험)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon;Kim, Jun-Sub;Lee, Sung-Jae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.133-137
    • /
    • 2011
  • Low-e glazing is classified as soft low-e glazing and hard low-e glazing. Hard low-e glazing can be temperable and its handling is comfortable because its coating film is a oxide film generated at high temperatures. But there is a fatal weakness that its insulation performance and shielding performance are lower compared to soft low-e glazing by low electrical conductivity of coating film. Soft low-e glazing is excellent because its coating film consists of Ag that is excellent electrical conductivity and it has strength that can supply various product consumers want. But soft low-e glazing has weaknesses that temperable and handling are difficult because Ag is oxidized easily. Therefore this study analyzes thermal performance of glazing by changing filling gas according to applying low-e glazing through simulation to judge performance before making sample. After this process, a comparative experimental study was done through TVS by making temperable low-e glazing.

  • PDF

Comparative Study on Mechanical Behavior after Deformation Recovery of Polymeric Foam for Ships and Offshore Structures (폴리머 폼의 선박 및 해양구조물 적용을 위한 변형 회복 후 기계적 거동 특성 분석)

  • Kim, Seul-Kee;Kim, Jong-Hwan;Lee, Jeong-Ho;Park, Seong-Bo;Lee, Jae-Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.3
    • /
    • pp.195-200
    • /
    • 2016
  • In this study, compression tests for the polyisocyanurate foam which is recognized as the insulation material for the storage tank of the liquefied natural gas (LNG) were carried out for investigation of the material characteristic of mechanical behavior. Deformation recovery ratio according to the various initial deformation levels were estimated and the mechanical behavior of foams that are experienced compressive deformation was also obtained experimentally. The test results were analyzed based on the conditions of initially applied strain level and engineering strain rate.

Electrical and Mechanical Strength Properties of Epoxy/Micro Silica and Alumina Composites for Power Equipment (전력기기용, 에폭시/마이크로 실리카 및 알루미나 복합제의 전기적·기계적 파괴 강도 특성)

  • Park, Joo-Eon;Park, Jae-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.7
    • /
    • pp.496-501
    • /
    • 2018
  • In this study, we prepared 40, 45, 50, 55, 60, 65, and 70 wt% content composites filled in epoxy matrix for two micro silica and three micro alumina types for use as a GIS heavy electric machine. As a filler type of epoxy composite, micro silica composites showed excellent AC breakdown strength properties compared to micro alumina composites in the case of electrical properties of micro silica and alumina. The electrical breakdown properties of micro silica composites increased with increasing filler content, whereas those of micro alumina decreased with increasing filler content. In the case of mechanical properties, the micro silica composite showed improved tensile strength and flexural strength compared with the micro alumina composite. In addition, mechanical properties such as tensile strength and flexural strength of micro silica and alumina composites decreased with increasing filler content. This is probably because O-H groups are present on the surface of silica in the case of micro silica but are not present on the surface of alumina in the case of micro alumina.

Analysis of the Ultrasonic Signals by the Partial Discharge and Noises from the Transformer (변압기 부분방전과 노이즈에 의한 초음파 신호 분석)

  • Gwon, Dong-Jin;Jeong, Gil-Jo;Jin, Sang-Beom;Gwak, Hui-Ro
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.354-360
    • /
    • 2002
  • The partial discharge detecting method using the ultrasonic technique has been investigated to monitor the insulation ageing of a transformer. However, the result of the studies on the ultrasonic technique for detecting of partial discharge in the operating transformer is not enough yet to utilize. This paper presents the analysis of the ultrasonic signals due to the partial discharge in a model transformer and the corona in air at a shielded high voltage room. In addition, the ultrasonic signals due to the vibration from the core, operation of the cooling pump, the fan and the OLTC at the 345㎸ power transformer, were analyzed and corona noise from overhead transmission line in 345㎸ substation were measured to remove the electrical and mechanical noises from the transformer. Furthermore, ultrasonic signal due to the partial discharge in the 154㎸ power transformer with in $C_2$$H_2$ gas warning condition was measured. The inside of the transformer was examined with care. which confirms the existence of the partial discharge source.

A Study on the Three-Dimensional Steady State Temperature Distributions and BOR Calculation Program Development for the Membrane Type LNG Carrier (Membrane Type LNG선의 3차원 정상상태 온도분포 및 BOR 계산 프로그램 개발에 관한 연구)

  • 이정혜
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.140-149
    • /
    • 1999
  • This study is on the development of the computer program that calculates a 3-D hull temperadistribution and analyzes BOR(Boil off rate) to be important to the heat design of a membrane type LNG carrier. The quarter of a tank is taken as an calculation model. And the thermal conductivity of insulation is assumed to be the function of a temperature. In the present steady state calculation, the temperature of LNG in a cargo tank is assumed to be -$162^{\circ}C$ and the air temperature of a cofferdam, to be +$5^{\circ}C$. The lowest air temperature in compartments is calculated as $21.39^{\circ}C$ under the USCG condition ($T_{air}=-18^{\circ}C,\;T_{sw}=O^{\circ}C)$ and B.O.R value is O.0977%/day under the maximum boil-off condition, IMO IGC ($T_{air}=45^{\circ}C,\;T_{sw}=32^{\circ}C$), which satisfies the requirement by KOGAS. The calculated temperature distribution over tank panels at each condition is maximum 3% less than GTT's results. From the results of this study, it can be concluded that the present design of LNG cargo tank satisfies the requirement by KOGAS.

  • PDF