• Title/Summary/Keyword: gas insulation

Search Result 539, Processing Time 0.028 seconds

A Design of UHF-Sensor for Diagnosis of Insulator (절연진단용 UHF 센서 모델 설계)

  • Choi, Eun-Hyuck;Do, Yeong-Heoi;Kim, Gi-Chai;Kim, Lee-Kook;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.115-117
    • /
    • 2005
  • If obstacle in GIS(Gas Insulted Switchgear), its affects are great are on the community and it is consequently demanded lots of difficulities to recover and repair. Accordingly, diagnosis techniques, that are able to prevent from accidents before they happen by providing more stable and highly reliable power effectively and finding sign of the accidents is very important. A novel UHF(Ultra High Frequency)-microstrip antenna is presented. The measured impedance bandwidth of the proposed antenna is from 0.5[GHz] to 15[GHz] with the stop band from 0.5[GHz] to 10.7[GHz] for VSWR<2. Form results of this study, The antenna is will play an important role for the sensor for insulation diagnosis system by UHF method of real site GIS and power equipment using $SF_6$ gas.

  • PDF

A Study on the Algorithm for Detection of Partial Discharge in G15 Using Wavelet Transform (웨이브렛 변환을 이용한 GIS의 부분방전 검출 알고리즘에 관한 연구)

  • 강진수;김철환
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.1
    • /
    • pp.25-34
    • /
    • 2003
  • Gas insulated switchgear(GIS) is an important equipment in a substation. It is highly desirable to measure a partial discharge(PD) in GIS which is a symptom before insulation breakdown occurs. The issue is that the PD signal is weak and sensitive to external noise. In this paper, the algorithm for detection of PD in GIS using wavelet transform is proposed. The wavelet transform provides a direct quantitative measure of spectral content, "dynamic spectrum", in the time-frequency domain. The recommended mother wavelet is 'Daubechies' wavelet. 'db4', the most commonly applied mother wavelet in the power quality analysis, can be used most properly in disturbance phenomena which occurs rapidly for a short time. Through the procedure of wavelet transform, noise extraction and reconstruction, the signal is Analyzed to determine the magnitude of PD in GIS. In experimental results, we can know that partial discharge is exactly detected in combination of Dl and D2 using wavelet transform.transform.

Effects of Heat Treatment on Polyethylene Film for Power Cable Insulation(I) (전력 케이블용 폴리에틸렌의 열처리 효과(I))

  • Hong, Jin-Woong;Suzuoki, Yasuo;Mizutani, Teruyoshi
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1174-1176
    • /
    • 1993
  • Morphology of low density polyethylene(LDPE) such as the degree of crystallinity changes with thermal history etc. In order to clarify the effects of morphological changes on electrical breakdown, we studied direct current and impulse breakdown phenomena of LDPE films heat-treated at 100[$^{\circ}C$] for 1[H] in silicone oil and subsequently cooling to various ways. The degree of crystallinity was estimated by the infra red absorption and X-ray diffraction measurements for the specimens of slowly cooled, cooled in water, original, and cooled in liquid nitrogen gas. As the result, we obtained that the first, second, third, and fourth was slowly cooled of 70.23[%], cooled in water of 61.6[%], original specimen of 56.75[%], and cooled in liquid nitrogen gas of 34.7[%] respectively. The crystalline size and distribution of specimens were researched by Differential scanning calolimeter measurements.

  • PDF

Development and application of the semi-internal type UHF PD sensor for Gas Insulated Switchgear (초고압 GIS의 CT 단자부를 이용한 Semi-내장형 UHF PD 센서 개발 및 적용)

  • Kang, W.J.;Lee, D.H.;Lee, Y.H.;Shin, Y.S.;Kim, Y.G.;Oh, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2038-2039
    • /
    • 2007
  • In this work, a novel semi-internal type UHF PD sensor has been proposed and related investigations has been performed in order to detect the partial discharges that could be possibly produced at the insulation system of the gas insulated switchgear(GIS). This sensor was designed to mount on the CT terminal hole of GIS using the spiral antenna theory. Therefore this type sensor can be install on GIS during the power apparatus has been operation and better sensitivity compare to the commercial external type UHF PD sensor.

  • PDF

Electron Transport Characteristic in $SF_6-N_2$ Mixture Gases by MCS-BEq Simulation (시뮬레이션에 의한 $SF_6-N_2$ 혼합기체의 전자수송특성)

  • Kim, Sang-Nam
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.507-508
    • /
    • 2006
  • $SF_6$ gas is widely used in industrial of insulation field. In this paper, $N_2$ is mixed to improve pure $SF_6$ gas characteristics. Electron transport coefficients in $SF_6-N_2$ mixture gases are simulated in range of E/N values from 70 to 400 [Td] at 300K and 1 Torr by using Boltzmann equation method. The results have been obtained by using the electron collision cross sections by TOF, PT, SST sampling, compared with the experimental data determined by the other author. It also proved the reliability of the electron collision cross sections and shows the practical values of computer simulation. The result of Boltzmann equation and Monte Carlo Simulation has been compared with experimental data by Ohmori, Lucas and Carter. The swarm parameter from the swarm study are expected to sever as a critical test of current theories of low energy scattering by atoms and molecules.

  • PDF

Mathematical Modeling on the Corrosion Behavior of the Steel Casing and Pipe in Cathodic Protection System (음극방식 시스템에서의 압입관과 배관의 부식거동에 관한 수학적 모델링)

  • Kim Y.S.;Li S.Y.;Park K.W.;Jeon K.S.;Kho Y.T.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.40-46
    • /
    • 1998
  • Mathematical modeling on the corrosion of the steel casing and main pipe due to the protection current resulting from a cathodic protection system was carried out using boundary element method. The model is consisted of Laplace's equation with non-linear boundary conditions(Tafel equations) and the iterative technique to determine the miexed potential of the steel casing. The model is applied to the normal steel casing section as well as abnormal one with defects such as metal touch and insulation defects. From the modeling procedure, we can calculate the potential distributions and current density distributions of the system. The theoretical results of the qualitatiive corrosion aspect along the steel casing and main pipe agree well with the experimental results within the experimental conditions studied.

  • PDF

A Study of Horizontal Surface Discharge Characteristics for Dew-Point of Dry-Air and Materials of Solid Insulator in Quasi-Uniform Field (Dry Air 중의 준평등전계에서 노점과 고체절연물 재질에 따른 수평연면방전 특성 연구)

  • Kang, Byoung-Chil;Seok, Jeong-Hoo;Min, Gyeong-Jun;Bae, Sungwoo;Lee, Kwang-Sik;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.64-69
    • /
    • 2015
  • This study investigates the Horizontal surface discharge characteristics of solid insulators by varying their materials, and the dew-point of dry-air. The methodology of this study is that a quasi-uniform field is first applied to a test chamber. Then, the chamber is filled with dry-air as an insulation gas which pressure is varied from 1 to 6atm while applying an AC voltage to the chamber. The used solid insulators are teflon, polyethlene and polyurethane. As the dew-point is lower and the pressure of dry-air is higher, the flashover voltage of all solid insulators increases more. When each characteristic of the solid insulators is compared under the same gas pressure, the flashover voltage of teflon is the highest. Then, the flashover voltage of polyethlene is higher than that of polyurethane. Moreover, it is observed that the flashover voltage increases as the horizontal distance between the electrodes of each solid insulator become larger, respectively. However, as the pressure is increased, flashover voltage of the solid insulators is saturated. Therefore, selection of cost-effective insulation is needed in order to appropriate pressure.

Development of 25.8kV class solid insulated switchgear (25.8kV 고체절연스위치기어 개발)

  • Lee, J.H.;Ma, J.H.;Yu, L.;Lee, J.G.;Won, S.Y.;Lee, S.W.;Kim, Y.G.;Kil, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.226-228
    • /
    • 2008
  • In recent years, the companies of electric power equipment for MV and HV classes trend to develop the eco-friendly insulated(solid, eco-gas, air etc.) switchgear which replaces existent SF6 gas insulated switchgear due to environmental problems such as global warming and so on. This paper makes reference to the newly developed Solid Insulated Switchgear (SIS) which uses the eco-friendly material such as epoxy for insulation. The insulation of the solid insulated switchgear (SIS) is composed of an epoxy, vacuum and air. The solid insulated switchgear (SIS) is a slate of the art product. The advantages of SIS are advanced reliability, economical efficiency, safety, maintenance free, reduction of installation area and the protection of environment. The solid insulated switchgear (SIS) is FE Analyzed such as electromagnetic, mechanical, thermal and fluid in order to find the optimal design. Thens SIS has been verified by international standard test. (IEC 62271 - 100 and so on.) As a result of this, the solid insulated switchgear (SIS) has been estimated as an alternative for eco-friendly MV class switchgear.

  • PDF

Analysis on the Dielectric Characteristics of Gaseous Nitrogen for Developing Eco-friendly High Voltage Apparatuses (친환경 고전압 전력기기 개발을 위한 GN2의 절연특성 분석)

  • Bang, Seungmin;Lee, Onyou;Kim, Junil;Kang, Jong O;Lee, Hongseok;Ko, Taekuk;Kang, Hyoungku
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.356-360
    • /
    • 2014
  • The environmental pollution caused by green-house gases such as $SF_2$ has been becoming the main issue of industrial society. As a part of these efforts, 180 countries signed the Kyoto Protocol in 1997 to cut back on their green-house gas emissions [1]. Therefore, a study on the dielectric characteristics of the $GN_2$ is important for designing a eco-friendly high voltage apparatuses. In this paper, to develop an electrically reliable, stable, and eco-friendly high voltage apparatus, the breakdown voltage and partial discharge inception voltage characteristics in $GN_2$ considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. Also, the dielectric characteristics of the $GN_2$ are analyzed by using a Finite Elements Method (FEM) according to various field utilization factors. The results are expected to be applicable to designing the high voltage apparatuses using $GN_2$ as an insulation gas.

Numerical Analysis on the Stress and Deformation Characteristics of LNG Membrane Storage Tank System with Corner Protection (코너프로텍션 설치에 따른 멤브레인 LNG 저장탱크 시스템의 응력 및 변형거동 특성에 관한 수치해석)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.9-14
    • /
    • 2009
  • In this study, the stress and deformation characteristics of corner protection in which is fabricated in an insulation area have been analyzed using a finite element method. The proposed corner protection may increase the strength and leakage safeties of conventional LNG storage system. The stress and deformation of LNG storage tank system are computed for an insulation panel box, membrane inner tank, and prestressed concrete outer tank. The FEM computed results indicate that the stress and displacement of new membrane LNG tank system with a corner protection between an inner tank and an outer tank are reduced in comparison to those of a conventional membrane LNG tank. This is explained that the strength safety of LNG membrane tank system may be increased due to a strength stiffness of a corner protection.

  • PDF