급냉각기간에서 멤브레인형 LNGC의 분무냉각 열해석에 관한 연구 (A Study on the Thermal Analysis of Spray Cooling for the Membrane Type LNGC During the Cool-Down Period)

  • 이정혜;김경근;노승탁;정한식;김성규
    • 대한기계학회논문집B
    • /
    • 제27권1호
    • /
    • pp.125-134
    • /
    • 2003
  • The present paper is concerned to the thermal analysis during the cool-down period of 138,000 m$^3$class GTT MARK-III membrane type LNG carrier servicing with LNG from the Middle East to Korea. It is the cool-down period that cools the insulation wall and the gas in LNG tank to avoid the thermal shock as the start of loading of -162$^{\circ}C$ LNG. For six hours of the standard cool-down period, the temperature of NG falls down from -4$0^{\circ}C$ to -13$0^{\circ}C$ and especially the mean temperature of the 1st barrier in the top side insulation wall falls down from -38.38$^{\circ}C$ to -122.42$^{\circ}C$ in case of IMO design condition. By the 3-D numerical calculation about the cargo tank and the cofferdam, the temperature variation in hulls and insulations is precisely predicted in this paper. And the mean temperature variation of gas is calculated as the function of the spraying rate by the heat balance model during the cool-down period.

노후 고등학교 건물의 에너지효율화 리모델링을 위한 요소기술의 성능 평가 (Evaluating Performance of Energy Conservation Measures on Energy-Efficient Remodeling at Deteriorated High School Buildings)

  • 이상춘;최영준;최율
    • KIEAE Journal
    • /
    • 제13권5호
    • /
    • pp.97-102
    • /
    • 2013
  • Many countries over the world have acknowledged the global warming problem by greenhouse gas emission and tried to solve the problem. The Korean government has also taken many actions such as The Act on Low Carbon, Green Growth and on Promoting Green Building in that architectural building section takes 1/4 of national greenhouse gas emission. Under the situation that buildings constructed 15 years ago when insulation standards were reinforced take about 74%, The Plan on Vitalizing Green Remodeling, finally established on July 2013, will induce energy-efficient remodeling of deteriorated buildings. Using the energy simulation by the Visual DOE 4.0 program, this paper proposed the ways of energy-efficient remodeling of deteriorated high school buildings by measuring energy saving performance of factors that were drawn from the previous study. The factors considered are insulation, window's SHGC, south louver, system efficiency, and indoor setting temperature. Among them, all factors except SHGC proved contribution to reducing energy use at deteriorated high school buildings, compared with the baseline energy consumption.

$SF_6$와 공기의 혼합기체중에서의 연면 코로나 방전 (A Study on the Surface Corona Discharge in the Gas with different Mixing Ratio of Air to $SF_6$)

  • 전춘생;조기선;우호환
    • 전기의세계
    • /
    • 제26권6호
    • /
    • pp.78-85
    • /
    • 1977
  • This paper studies flashover voltage and surface corona loss of A.C and D.C in the mixed gas of air and SF$_{6}$ for solid insulators P.V.C, arcylic, glass and bakelite in two cases. In one case, those solids are covered with transformer oil and the other case, those solids are not covered with it. 1) The flashover voltage for each solids in SF$_{6}$ is more than three times compared with that in the air. The flashover voltage for P.V.C is the highest and then arcylic, glass, bakelite in a decreasing order. 2) The more the amount of SF$_{6}$ in the mixing ratio, the less corona loss. The P.V.C shows the least amount of corona loss and the bakelite the largest. 3) Compared with the corona loss of positive polarity and the negative polarity, the former has less corona loss than the latter. 4) The more the number of flashover discharge, the less insulation of each solids, but in case of bakelite, insulation almost vanishes after a couple of discharge. 5) When each insulator is covered with transformer oil, the flashover voltage generally increases and the corona loss decreases.eases.

  • PDF

800kV $SF_6$ 가스절연 개폐장치용 (GIS) 복합절연애자 (Composite Hollow Insulator)의 표면오손시 내전압특성 (Flashover Voltage of 800kV Class Composite Hollow Insulator for $SF_6$ Gas Insulated Switchgear (GIS))

  • 이창용;윤자홍;최병화;윤치영;고경석;반석걸;허종철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1449-1451
    • /
    • 2002
  • A developed 800kV class composite hollow insulator for $SF_6$ Gas Insulated Switchgear (GIS) was tested as to insulation with their surfaces contaminated. The wet power frequency withstand voltage of the silicone rubber housing was about 135kV at an equivalent salt deposite density of $5kg/m^2$, to sufficiently satisfy the required performance. According to IEC 60507, the salt fog withstand voltage was measured at 565kV, and the highest measured leakage current was below 0.2mA. Therefore, it was clarified that the composite hollow insulator has sufficient insulation performance even when it is contaminated on the surface.

  • PDF

가스터빈 차폐막의 소음 저감효과에 관한 연구 (The Noise Reduction Effect by the Enclosure of Gas Turbines)

  • 박대훈;신유인;박성규;김강일;송철기
    • 한국정밀공학회지
    • /
    • 제34권4호
    • /
    • pp.287-292
    • /
    • 2017
  • A gas turbine is the main equipment used in a combined heat and power plant. It generates a high sound pressure noise level. To reduce the noise level, an enclosure is installed around the turbine. The sound insulation performance of the enclosure affects the amount of external noise reduction. In this study, a sound transmission loss analysis is performed using the boundary element method to predict sound insulation performance according to the numbers and shapes of the supporter. Radiated noise analysis is also performed for the main external points of the enclosure using ray-acoustics. The results of these analyses are presented and a design plan is proposed that reduces the sound pressure noise level of the enclosure.

GIS 절연진단센서 설계와 연면방전에 따른 방사전자파 특성 (A Design of Insulted Diagnosis Sensor and the Characteristics of Frequency Spectrum from the Radiated Electromagnetic Waves according to Surface Discharge)

  • 박숭규;최은혁;이광식
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.27-34
    • /
    • 2012
  • If obstacle in GIS(Gas Insulted Switchgear), its affects are great are on the community and it is consequently demanded lots of difficulities to recover and repair. Accordingly, diagnosis techniques, that are able to prevent from accidents before they happen by providing more stable and highly reliable power effectively and finding sign of the accidents is very important. A novel UHF(Ultra High Frequency)-microstrip antenna is presented. The measured impedance bandwidth of the proposed antenna is from 0.5GHz to 15GHz with the stop band from 0.5GHz to 10.7GHz for VSWR<2. Form results of this study, The antenna is will play an important role for the senser for insulation diagnosis system by UHF method of real site GIS and power equipment using $SF_6$ gas.

GITr(Gas Insulated Transformer) 내부에 발생되는 PD 신호의 패턴분석을 위한 PRPD와 CAPD 적용 결과 비교 (A comparative study of the PD pattern analysis based on PRPD and CAPD for the diagnosis of Gas Insulated Transformer)

  • 정승용;임윤석;구자윤;장용무;강창원;이영상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2060-2062
    • /
    • 2005
  • Partial Discharge (PD) phenomena occurred by different nature of insulating defects has been regarded as a random process by which Phase Resolved Partial Discharge Analysis (PRPDA) has been proposed and then commercially accepted for the diagnosis of the power apparatus since more than three decades. Moreover, for the same purpose, a novel approach based on the Chaotic Analysis(CAPD) has been proposed since 2000, in which PD phenomena is suggested to be considered as a deterministic dynamical process. In this work for the diagnosis of GITr, four different types of specimen were fabricated as a model of the possible defects that might possibly cause its sudden failures such as turn to turn insulation, inter coil insulation, free moving particle and protrusion. For this purpose, these defects are introduced into the GITr mock-up and experimental investigations have been carried out in order to analyze the related PD patterns by means of both PRPDA and CAPD respectively and then their comparisons are made systematically.

  • PDF

군집화 기법을 이용한 GIS 열화 패턴 연구 (A Study on Degradation Pattern of GIS Using Clustering Methode)

  • 이덕진
    • 한국전기전자재료학회논문지
    • /
    • 제31권4호
    • /
    • pp.255-260
    • /
    • 2018
  • In recent years, increasing electricity use has led to considerable interest in green energy. In order to effectively supply, cut off, and operate an electric power system, many electric power facilities such as gas insulation switch (GIS), cable, and large substation facilities with higher densities are being developed to meet demand. However, because of the increased use of aging electric power facilities, safety problems are emerging. Electromagnetic wave and leakage current detection are mainly used as sensing methods to detect live-line partial discharges. Although electromagnetic sensors are excellent at providing an initial diagnosis and very reliable, it is difficult to precisely determine the fault point, while leakage current sensors require a connection to the ground line and are very vulnerable to line noise. The partial discharge characteristic in particular is accompanied by statistical irregularity, and it has been reported that proper statistical processing of data is very important. Therefore, in this paper, we present the results of analyzing ${\Phi}-q-n$ cluster distributions of partial discharge characteristics by using K-means clustering to develop an expert partial discharge diagnosis system generated in a GIS facility.

에폭시와 dry-air 혼합절연물의 절연파괴특성 (Electrical Breakdown Characteristics of Epoxy and dry-air Composite Insulation)

  • 정해은;오진헌;임종남;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1389-1390
    • /
    • 2007
  • SF6 gas used widely as insulating component is rising as the environment problem. Electrical breakdown characteristics of epoxy and dry-air composite insulation was investigated on thickness of epoxy and pressure of dry-air under non-uniform field. The gap of needle to plane was from 2mm to 5mm. The pressure of dry-air was varied within the range of $0.1{\sim}0.6$ MPa. The thickness of a needle was 1mm and the curvature radius of a needle end was 100um. The diameter of a plane made of the stainless steel was 50mm. As a result of the experiment, breakdown voltage was increased about 3 times when epoxy was used. The impact that the thickness of epoxy influences on breakdown voltage was poor. It needs suitable thickness computation because the insulating gap of the gas is short as epoxy thickness increases.

  • PDF

Fabric/EPDM계 고무의 제작 공정에 따른 삭마 특성 (The Ablation Effect of Fabric/EPDM Rubber with Manufacturing process)

  • 김진용;노태호;이원복;조원만;이영우
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.92-95
    • /
    • 2012
  • 격벽형 펄스분리장치를 갖는 이중펄스 로켓모타의 경우 2단 모타 추진제 연소시 1단 모타 연소실 내부에 높은 강도의 가스흐름이 발생하므로 1단 모타 연소관 내열재 설계가 중요한 변수들 중의 하나이다. 본 논문에서는 이러한 높은 강도의 가스흐름으로부터 연소실 내부를 보호하기 위하여 fabric을 삽입한 EPDM계 고무의 제작 공정을 확립하였으며 높은 강도의 가스흐름을 유발하도록 설계된 모사모타에 적용하여 삭마 특성을 분석하였다.

  • PDF