• 제목/요약/키워드: gas extraction mode

검색결과 55건 처리시간 0.029초

Liquid-liquid extraction process for gas separation from water in polymeric membrane: Mathematical modeling and simulation

  • Salimi, Nahid;Moradi, Sadegh;Fakhar, Afsaneh;Razavi, Seyed Mohammad Reza
    • Membrane and Water Treatment
    • /
    • 제7권5호
    • /
    • pp.463-476
    • /
    • 2016
  • In this study, application of polypropylene hollow fiber membrane contactors for $CO_2$ removal from water in liquid-liquid extraction (LLE) mode was simulated. For this purpose, a steady state 2D mathematical model was developed. In this model axial and radial diffusion was considered to $CO_2$ permeation through the hollow fibers. $CO_2$ laden water is fed at a constant flow rate into the lumen side, permeated through the pores of membrane and at the end of this process, $CO_2$ solution in the lumen side was extracted by means of aqueous diethanolamine (DEA) and chemical reaction. The simulation results were validated with the experimental data and it was found a good agreement between them, which confirmed the reliability of the proposed model. Both simulation and experimental results confirmed the reduction in the percentage of $CO_2$ removal by increment of feed flow rate.

유류오염지역 정화를 위한 슬러핑과 미생물증진법의 효율평가에 관한 현장 적용성 연구 (A Field Study on the Evaluation of Slurping and Bioaugmentation Effect in Petroleum Contaminated Area)

  • 박응렬;이광렬;서창일;조장환
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권3호
    • /
    • pp.32-38
    • /
    • 2012
  • This study was conducted to evaluate the slurping process affecting the variation of free product and VOCs concentration and the bioaugmentation effect on bioremediation process. Free products and soil gas were extracted from 30 extraction wells installed in a petroleum contaminated area. The extraction system was operated for 10 hours per day with 1 hour on-and-off mode. The thickness of free product in extraction well was decreased from 11.7 cm to 4.5 cm and the VOCs concentration was increased from 10.37 ppm to 30.78 ppm during the operation period. After the slurping process for 2 months, contaminated soil was treated with bioremediation process in 2 cells, $15{\times}40$ m, biologically enhanced with adjusting oxygen, moisture and nutrients concentration. Total 1,400 L of microbial inoculant, Naturesys. (Dong Myung Ent. Co.) was added to the pile B, which has an outstanding ability for degrading petroleum hydrocarbons. The results showed that bioremediaton effect in soil with the microorganisms solution is 33% higher than that in soil with only residual bacteria.

DMD 기법을 적용한 모형 가스터빈의 연소불안정성 평가에 관한 실험적 연구 (An Experimental Study on the Combustion Instability Evaluation by Using DMD)

  • 손진우;손채훈;윤지수;윤영빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.59-60
    • /
    • 2017
  • 가스터빈 연소기의 연소불안정성을 평가하기 위해 동적모드분해(dynamic mode decomposition, DMD) 기법을 적용하였다. DMD 기법으로 도출된 감쇠계수(damping coefficient)와 FFT 결과를 비교 분석 하였다. 또한 화염전달함수 (flame transfer function, FTF)를 도출하는 실험적 방법에 DMD 기법을 적용하여 분석을 시도하였다. 기존에 제시된 열방출 섭동을 추출하는 방법에서 개선된, OH PLIF 이미지를 이용하여 열방출 섭동을 추출하는 방법을 사용하였다. 분석 결과, 열방출 섭동의 추출 위치에 따라 화염전달함수의 이득(gain)이 변하는 것을 확인하였다.

  • PDF

Analysis of Agrochemical Residues in Tobacco Using Solid Phase Microextraction-Gas Chromatography with Different Mass Spectrometric Techniques

  • Lee, Jeong-Min;Jang, Gi-Chul;Kim, Hyo-Keun;Hwang, Geon-Joong
    • 한국연초학회지
    • /
    • 제30권2호
    • /
    • pp.117-124
    • /
    • 2008
  • A solid phase microextraction (SPME) method in combination with gas chromatography/mass spectrometric techniques was used for the extraction and quantification of 12 selected agrochemical residues in tobacco. The parameters such as the type of SPME fiber, adsorption/desorption time and the extraction temperature affecting the precision and accuracy of the SPME method were investigated and optimized. Among three types of fibers investigated, polyacrylate (PA), polydimethylsiloxane (PDMS) and polydimethylsiloxane-divinylbenzene (PDMS-DVB), PDMS fiber was selected for the extractions of the agrochemicals. The SPME device was automated and on-line coupled to a gas chromatograph with a mass spectrometer. Mass spectrometry (MS) was used and two different instruments, a quadrupole MS and triple quadrupole MS-MS mode, were compared. The performances of the two GC-MS instruments were comparable in terms of linearity (in the range of 0.01$\sim$0.5 $\mu$g/mL) and sensitivity (limits of detection were in the low ng/mL range). The triple quadrupole MS-MS instrument gave better precision than that of quadrupole MS system, but generally the relative standard deviations for replicates were acceptable for both instruments (< 15%). The LODs was fully satisfied the requirements of the CORESTA GRL. Recoveries of 12 selected agrochemicals in tobacco yielded more than 80% and reproducibility was found to be better than 10% RSD so that SPME procedure could be applied to the quantitative analysis of agrochemical residues in tobacco.

GC/MSD를 사용한 원유 내 잔류농약의 분석법 연구 (Research for the Analytical Method of Various Pesticides in Raw Milk by Gas Chromatography-Mass Spectrometry)

  • 오남수;신용국;백승천
    • 한국축산식품학회지
    • /
    • 제29권4호
    • /
    • pp.482-486
    • /
    • 2009
  • The aim of this study was to optimize a simple, fast, and economical analysis procedure for the determination of 16 different pesticides in raw milk via GC/MSD. Analyses were performed via gas chromatography with electron impact mass spectrometric detection in the selected ion monitoring mode (GC/MSD-SIM) using Pentachloronitrobenzene as the internal standard. The modified sample preparation methodology was based on the Pesticide Analytical Manual (PAM) of the FDA concerning fat extraction, ACN-ether partitioning, and clean-up of the Sep-Pak florisil cartridge. The modified methodology for the determination of the 16 pesticides was validated. The range of LOQs of the 16 pesticides was likely three times lower than their Maximum Residence Levels (MRLs). The recoveries of most of the pesticides were acceptable at the fortification levels of 0.5 and 1.0 ${\mu}g/mL$ and their RSD (%) level was less than 20%. None of the 16 pesticides were detected in the selected raw milk samples.

기체 크로마토그래피/질량분석기를 이용한 종이류 중 알킬페놀류, 클로로페놀류 및 비스페놀 A 정량 (Sensitive Determination of Alkylphenols, Chlorophenols, and Bisphenol A using GC/MS-SIM in Paper Materials)

  • 김협;김진호
    • Environmental Analysis Health and Toxicology
    • /
    • 제18권1호
    • /
    • pp.45-55
    • /
    • 2003
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrom-etry-selected ion monitoring (GC/MS-SIM) mode followed by two work-up methods for comparison; isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in paper samples were extracted with acetonitrile. Also, solid -phase extraction (SPE) with XAD -4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The SIM responses were linear with the correlation coefficient varying 0.9717 ∼ 0.9995 (isoBOC derivatization), and 0.9842 ∼ 0.9980 (TBDMS derivatization). The recoveries were 82.4 ∼ 108.8%) by area ratio of phenanthrene -d$\_$10/ vs bisphenol A-d$\^$l6/. (isoBOC derivatization and TBDMS derivatization) The range of concentrations was respectively, 0.95 ∼ 1.44 ng/g in 2,4-dichlorophenol, 1.01 ∼ 1.17 ng/g in t-butylphenol,2.17 ∼ 5.84 ng/g in pentachlorophenol, 12.68 ∼ 14.88 ng/g in nonylphenol and 30.84 ∼ 153.72 ng/g in bisphenol A.

GC-MS를 이용한 사람 뇨시료 중 비만치료제 분석 및 비만치료제 남용 현황의 법과학적 고찰 (Development of a Simultaneous Detection and Quantification Method of Anorectics in Human Urine Using GC-MS and its Application to Legal Cases)

  • 최혜영;이재신;장문희;양원경;김은미;최화경
    • 약학회지
    • /
    • 제57권6호
    • /
    • pp.420-425
    • /
    • 2013
  • Phentermine (PT) and phenmetrazine (PM) have been widely used as anti-obesity drugs. These drugs should be used with caution due to its close relation to amphetamine in its structure and toxicity. PT and PM, amphetamine-type anorectics, have recently been considered as alternatives for methamphetamine abuse in Korea. In addition, the misuse and abuse of PT and PM obtained by illegal sources such as the internet become a serious social problem. In the present study, a simultaneous detection and quantification method for determining PT and PM in human urine was developed and validated according to the international guidelines. The urine samples were screened using a fluorescence polarization immunooassay and analyzed by gas chromatography mass spectrometry (GC-MS) after extraction using automatic solid phase extraction (SPE) with a mixed-mode cation exchange cartridge and derivatization with pentafluoropropionic anhydride (PFPA). The validation results for selectivity, linearity, limits of detection (LOD) and quantification (LOQ), intra- and inter-assay precision and accuracy and recovery were satisfactory. The validated method was successfully applied to authentic urine samples collected from 38 drug abuse suspects. PT and/or PM were identified with or without methamphetamine in urine samples. Abuse of PT and PM have increased continuously in Korea, therefore, closer supervision of the inappropriate use of anoretics is necessary.

Development of Analytical Technology Using the HS-SPME-GC/FID for Monitoring Aromatic Solvents in Urine

  • Lee, Mi-Young;Chung, Yun Kyung;Shin, Kyong-Sok
    • Mass Spectrometry Letters
    • /
    • 제4권1호
    • /
    • pp.18-20
    • /
    • 2013
  • Headspace solid phase micro-extraction gas chromatography/flame ionization detection (HS-SPME-GC/FID) method was compared with headspace gas chromatography/mass selective detection (HS-GC/MS). Organic solvent-spiked urine as well as urine samples from workspace was analyzed under optimal condition of each method. Detection limit of each compound by HS-SPME-GC/FID was $3.4-9.5{\mu}g/L$, which enabled trace analysis of organic solvents in urine. Linear range of each organic solvent was $10-400{\mu}g/L$, with fair correlation coefficient between 0.992 and 0.999. The detection sensitivity was 4 times better than HS-GC/MS in selected ion monitoring (SIM) mode. Accuracy and precision was confirmed using commercial reference material, with accuracy around 90% and precision less than 4.6% of coefficient of variance. Among 48 urine samples from workplace, toluene was detected from 45 samples in the range of $20-324{\mu}g/L$, but no other solvents were found. As a method for trace analysis, SPME HS GC/FID showed high sensitivity for biological monitoring of organic solvent in urine.

SENSITIVE DETERMINATION OF ELEVEN PHENOLIC ENDOCRINE-DISRUPTING CHEMICALS IN HUMAN URINE USING GAS CHROMATOGRAPHY/MASS SPECTROMETRY -SELECTED ION MONITORING

  • Kim, Hyub;Jang, Cheol-Hyeon
    • Environmental Engineering Research
    • /
    • 제12권3호
    • /
    • pp.93-100
    • /
    • 2007
  • I improved an analytical method for determining trace amounts of eleven phenolic endocrine-disrupting chemicals (11 phenolic EOCs) in human urine. The 11 phenolic EOCs were subjected to hydrolysis and then to solid phase extraction with a XAD-4 column. Alkylphenols, chlorophenols, and bisphenol A in XAD-4 column were eluted with acetonitrile, and the eluate was concentrated under a nitrogen stream, and then tert-butyldimethylsilylation. Separation and determination were done by gas chromatography, using mass spectrometry operating in the selective ion monitoring mode for quantitation. For tert-butyldimethylsily (TBDMS) derivatization the recoveries were $91.2{\sim}125.9%$, the limits of quantitation (LOQ) for the 11 phenolic EOCs in the nanogram-per-milliliter range ($0.025{\sim}1.000\;ng/mL$) were thus achieved by using 1 mL of urine, and the SIM responses were linear with the correlation coefficient varying by $0.9300{\sim}0.9943$. Based on the results for urine samples from unexposed individuals, 4-tert-octylphenol and pentachlorophenol were detected in hydrolysed urine sample. Other alkylphenols, chlorophenols and bisphenol A were not detected.

Simultaneous determination of corticosteroids in a herbal medicinal preparation by GC-MS

  • Jeong, Jae-Chul;Kim, Jin;Kim, Mee-Jung;Choi, Don-Woong;Chang, Seung-Yeup;Im, Moon-Kyo;Paeng, Ki-Jung
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.395.2-395.2
    • /
    • 2002
  • The determination method for 11 corticosteroids (betamethasone, cortisol. cortisone, cortisone acetate. dexamethasone. cortisol acetate, isoflupredone acetate, methylprednisolone. prednisone, prednisolone, and triamcinolone acetonide) in a herbal medicinal preparation (Sibjeondaibotang) by a gas chromatography-mass spectrometric (GC-MS) method with selected ion monitoring (SIM) mode is described. Samples (4 mL) were extracted by liquid-liquid extraction with diethyl ether. (omitted)

  • PDF