• Title/Summary/Keyword: gas extraction mode

Search Result 55, Processing Time 0.042 seconds

Analysis of $\beta$-Blockers in Whole Blood by GC/MS-SIM

  • Rhee, Jong-Sook;Yang, Hee-Jin;Seol, Il-Ung;Koo, Ki-Ser
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.219.3-219.3
    • /
    • 2003
  • We describe here solid-extraction and derivatisation methods of ${\beta}$-adrenoceptor blocking drugs used for the treatment of various cardiovascular disorders such as hypertension, angina pectoris and cardiac arrhythmia: propranolol, metoprolol, sotalol, timolol, oxprenolol, alpranolol, atenolol, pindolol. Solid-extraction and derivatisation methods are described involving the use of Bond Elut Certify cartridges, MSTFA and MBTFA. Gas chromatographic-mass spectrometry analysis(GC/MS) was carried out select-ion monitroing mode. (omitted)

  • PDF

Application and Optimization of the IsoButoxycarbonyl Derivatization method to the Analysis of Trace Level Phenols in Environmental Samples (환경시료로부터 미량 페놀류의 분석을 위한 isoButoxycarbonyl 유도체화 분석방법 적용 및 최적화)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.1
    • /
    • pp.37-51
    • /
    • 2002
  • Eleven phenols including two chlorophenols, eight alkylphenols and bisphenol A were derivatized with isobutylchloroformate to form their isobutoxycarbonyl derivatives. Standard phenol mixture was concentrated for the isobutoxycarbonyl (isoBOC) derivatization and analysed by gas chromatography/mass spectrometry (GC/MS). The recoveries of the derivatization method of alkylphenols, chlorophenols, and bisphenol A were calculated by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison; shaking and heating method. The linear detector responses were obtained in the concentration range of 5∼400 ng, with correlation coefficients varying from 0.9755∼0.9981. Recoveries of the alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison ; the US-EPA method and the isoBOC derivatization method, Eleven phenols in water samples were extracted with dichloromethane and then concentrated. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1∼109.9% and 90.3∼126.6% for the US-EPA method and the isoBOC.

Simultaneous detection for synthetic antimicrobials in muscle by high performance liquid chromatography-mass selective detector (HPLC-MSD) (HPLC-MSD 를 이용한 식육 중 합성항균제의 동시분석)

  • Hong In-Suk;Choi Yoon-Hwa;Kwon Taek-Boo;Lee Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.29 no.3
    • /
    • pp.317-330
    • /
    • 2006
  • This study was conducted to develop the analytical method about simultaneous determination for synthetic antimicrobials in muscle by high performance liquid chromatography - mass selective detector (HPLC- MSD). Solid phase extraction (SPE), matrix solid phase dispersion (MSPD) and liquid-liquid extraction (LLE) have been adapted as pretreatment procedures for HPLC- MSD. Among various solvent tested, methanol was chosen for extraction of synthetic antimicrobials in muscles. For the optimized response, the values of various MS parameters including fragment voltage, drying gas flow, nebulizer pressure, drying gas temperature were verified. The average recovery rates using MSPD and SPE for muscles of bovine and pork were 78.9-127.1% and 78.3-121.7%, respectively. This method was verified the satisfactory performance for fourteen synthetic antimicrobials excepting carbadox in muscle of pork as detection limit of $0.05{\mu}g/g$ on API/ES SIM mode.

Isotope-Dilution Mass Spectrometry for Quantification of Urinary Active Androgens Separated by Gas Chromatography

  • Lee, Su-Hyeon;Choi, Man-Ho;Lee, Won-Yong;Chung, Bong-Chul
    • Mass Spectrometry Letters
    • /
    • v.1 no.1
    • /
    • pp.29-32
    • /
    • 2010
  • Cross reacting antibodies can cause an overestimation of the results of immunoassays. Therefore, alternative methods are needed for the accurate quantification of steroids. Gas chromatography combined with isotope-dilution mass spectrometry (GC-IDMS) is developed to quantify urinary active androgens, testosterone, epitestosterone and dihydrotestosterone, which are clinically relevant androgens to both hair-loss and prostate diseases. The method devised involves enzymatic hydrolysis with $\beta$-glucuronidase, solid-phase extraction, liquid-liquid extraction using methyl tert-butyl ether and subsequent conversion to pentafluorophenyldimethylsilyl-trimethylsilyl (flophemesyl-TMS) derivatives for sensitive and selective analysis in selected-ion monitoring mode. Flophemesyl-TMS derivatization not only eliminates matrix interference but also has a good peak resolution within a 6 min-run. A selective and sensitive GC technique with flophemesyl-TMS derivatives also allows accurate quantitative analysis of three active androgens when combined with IDMS. The limit of quantification of the three analytes was <50 pg/mL, and extraction recoveries ranged from 91.9 to 102.1%. The precision and accuracy were 1.2~6.5% and 89.0~106.7%, respectively. This GC-IDMS method can be useful for evaluating the drug efficacy and monitoring the biological processes responsible for male-pattern baldness and prostate diseases.

Rapid Determination of Chlorostyrenes in Fish by Freezing-Lipid Filtration, Solid-Phase Extraction and Gas Chromatography-Mass Spectrometry

  • Kim, Min-Sun;Park, Kwang-Sik;Pyo, Hee-Soo;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.352-356
    • /
    • 2008
  • An analytical method has been developed for measuring chlorostyrenes in fish tissue sample. Extraction of chlorostyrenes from fish tissue was carried out by ultrasonication using acetone/n-hexane (5:2, v/v) mixture. Most of the lipids in the extract were eliminated by freezing-lipid filtration, prior to solid-phase extraction (SPE) cleanup. During freezing-lipid filtration, about 90% of the lipids extracted from the fish samples were easily removed without any significant losses of chlorostyrenes. For purification, SPE using Florisil was used for the rapid and effective cleanup. Quantification was performed using gas chromatography-mass spectrometry in the selected ion monitoring mode. Spiking experiments were carried out to determine the recovery, precision, and limits of detection (LODs) of the method. The overall recovery was above 80% in the spiked fish tissue sample at 10 and 100 ng/g levels, respectively. The detection limits for chlorostyrenes were ranged from 0.05 to 0.1 ng/g. This developed method is demonstrated to give efficient recoveries and LODs for detecting chlorostyrenes spiked into fish tissue with high lipid content.

Determination of Phthalates in Biota Samples Using Gas Chromatography/Mass Spectrometry (기체크로마토그래피/질량분석법을 이용한 생체시료 중 프탈산 에스텔류의 분석법)

  • Seo, Jung-Ju;Na, Yuncheol;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.400-409
    • /
    • 2001
  • A method for the analysis of most common phthalate acid esters (9 secies) in biota samples by gas chromatography-mass spectrometry-selected ion monitoring mode is described. Phthalates in biota samples are extracted by organic solvent and purified by Florisil column. Phthalates are easily contaminated during extraction prodedure. Since the extraction and cleanup steps for biota samples generally are more complicate than those for water or sediment samples, we compared with contamination state of each sample work-up step. By applying this developed method, the overall recoveries ranged between 79 - 117% in biota sample which was spiked with standards. For phthalates used in this study, the quantitaive accuracy, elution pattern on Florisil column, and detection limits were also investigated.

  • PDF

Performance Analysis on CHP Plant using Back Pressure Turbine according to Return Temperature Variation (배압터빈을 사용하는 열병합발전소의 열 회수 온도에 따른 성능특성 분석)

  • Im, Shin Young;Lee, Jong Jun;Jeon, Young-Shin;Kim, Hyung-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.6
    • /
    • pp.26-33
    • /
    • 2016
  • Combined heat and power (CHP) system is one of the power generation system which can generate both electricity and heat. Generally, mid-size and big-size CHP plant in Korea generate electricity from gas turbine and steam turbine, then supply heat from exhaust gas. Actually, CHP can supply heat using district heater which is located at low pressure turbine exit or inlet. When the district heater locates after low pressure turbine, which called back pressure type turbine, there need neither condenser nor mode change operating control logic. When the district heater locates in front of low pressure turbine or uses low pressure turbine extraction steam flow, which calls condensing type turbine, which kind of turbine requires condenser. In this case, mode change operation methods are used for generating maximum electricity or maximum heat according to demanding the seasonal electricity and heat.

An improved cross-correlation method based on wavelet transform and energy feature extraction for pipeline leak detection

  • Li, Suzhen;Wang, Xinxin;Zhao, Ming
    • Smart Structures and Systems
    • /
    • v.16 no.1
    • /
    • pp.213-222
    • /
    • 2015
  • Early detection and precise location of leakage is of great importance for life-cycle maintenance and management of municipal pipeline system. In the past few years, acoustic emission (AE) techniques have demonstrated to be an excellent tool for on-line leakage detection. Regarding the multi-mode and frequency dispersion characteristics of AE signals propagating along a pipeline, the direct cross-correlation technique that assumes the constant AE propagation velocity does not perform well in practice for acoustic leak location. This paper presents an improved cross-correlation method based on wavelet transform, with due consideration of the frequency dispersion characteristics of AE wave and the contribution of different mode. Laboratory experiments conducted to simulate pipeline gas leakage and investigate the frequency spectrum signatures of AE leak signals. By comparing with the other methods for leak location identification, the feasibility and superiority of the proposed method are verified.

Profiling of Urinary Environmental Estrogens by Gas Chromatography/Mass Spectrometry (GC/MS를 이용한 뇨 중 환경 에스트로겐들의 동시 프로필)

  • Yang, Yoon-Jung;Lee, Seon-Hwa;Chung, Bong-Chul
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.265-272
    • /
    • 1999
  • A simultaneous profile analysis of 19 environmental estrogens, which act like estrogen and may effect the endocrine system by binding to hormone receptors or influencing cell signaling pathways, was attempted. The present method was based on the selected ion monitoring (SIM) mode of gas chromatography/mass spectrometry (GC/MS). It involves solid-liquid extraction, enzyme hydrolysis, liquid-liquid extraction and quantitative conversion into trimethylsilyl (TMS)-ether derivatives. Analytical recovery range was 47.6 ~ 99.5% and the RSD values of within-a-day and day-to-day test were 0.66 ~ 9.33%, 1.66 ~ 16.14%, respectively. The Korean reference values for the evaluation of environmental estrogen effects were established by this method.

  • PDF

Volatile Free Acid Profiling of Body Fluids by Gas Chromatography (기체 Chromatograph를 이용한 체액내 Volatile Free Acid의 분석연구)

  • Kim, Kyoung-Rae;Hahn, Mi-Kyoung
    • YAKHAK HOEJI
    • /
    • v.32 no.1
    • /
    • pp.6-13
    • /
    • 1988
  • A gas chromatographic method is described for the determination of volatile free acids(VFAs) in body fluids. VFAs were trace enriched from body fluids by liquid-solid extraction using Chromosorb P as the solid sorbent and ether as the eluant. The enriched VFAs were injected in splitless injection mode onto a HP-20M fused silica capillary column. The flame ionization detector was used as the detector. The present method was applied to the profiling of VFAs in body fluids from patients suffering from the infectious disease, hepatitis. The VFAs concentrations were high in saliva of hepatitis patients and isobutyric acid detected in sera of hepatitis patients compared to healthy subjects.

  • PDF