• 제목/요약/키워드: gas chromatograph (GC)

검색결과 145건 처리시간 0.024초

OXYGEN CONCENTRATION IN THE CATHODE CHANNEL OF PEM FUEL CELL USING GAS CHROMATOGRAPH

  • Ha, T.H.;Kim, H.S.;Min, K.D.
    • International Journal of Automotive Technology
    • /
    • 제8권1호
    • /
    • pp.119-126
    • /
    • 2007
  • Because of the low temperature operation, proton exchange membrane (PEM) fuel cell has a water phase transition. Therefore, water management is an important operation issue in a PEM fuel cell because the liquid water in the fuel cell causes electrode flooding that can lower the cell performance under high current density conditions. In this study, in order to understand the reactant distributions in the cathode channels of the PEM fuel cell, an experimental technique that can measure the species concentrations of reactant gases by using gas chromatograph (GC) is applied for an operating PEM fuel cell. The oxygen distribution along the cathode flow channels of PEM fuel cell is mainly investigated with various operating conditions. Also, the relations between cathode flooding and oxygen concentrations and oxygen consumption pattern along the cathode channel configurations of the unit cell adopted for this study are discussed using GC measurement and visualization experiment of cathode flooding. It is found that the amount of oxygen consumption is very sensitive to various operating conditions of the fuel cell and was much affected by the flooding occurrence in cathode channels.

GC/AED를 이용한 HFC-134a의 미량 불순물 분석 (Determination of trace impurities of HFC-134a by gas chromatograph with atomic emission detector (GC/AED))

  • 김명자;임정식;이진복;이정순
    • 분석과학
    • /
    • 제30권5호
    • /
    • pp.240-251
    • /
    • 2017
  • 1,1,1,2-수소불화탄소(HFC-134a)는 에어컨에 주로 사용되는 냉매로, 최근 온실가스로 규제되어 정제를 통한 재사용 방법이 권장되고 있다. 폐냉매의 재사용 기준 평가를 위해서는 폐냉매에 존재하는 미량 성분의 정량분석이 매우 중요하다. 본 연구에서는 표준 물질이 없어서 정량화하기 어려웠던 C, H, Cl, F가 포함된 미량 성분들을 GC/AED (gas chromatograph-atomic emission detector)를 이용하여 정량분석하였다. 이를 위하여 GC/MSD (mass selective detector)를 통한 정성분석을 선행하였다. 또한 성분의 원자 수와 비례하여 반응하는 AED의 특성을 조사하기 위하여, 탄화수소 혼합 표준물질을 이용하여 선형성을 확인하였다. 시료 중 C, H, Cl, F가 포함된 미량 성분의 정성 분석 결과, 주성분인 HFC-134a와 유사 냉매류들을 포함한 총 15 개의 성분이 검출되었다. MSD 결과를 토대로 AED를 이용한 미량 성분들을 정량 분석한 결과, 한 시료는 $CHClF_2$ 성분($45438.38{\mu}mol/mol$), 또 다른 시료는 $C_2H_2ClF_3$ 성분($1311.47{\mu}mol/mol$)이 가장 높은 몰분율을 나타냈다. 본 연구에서는 이 분석법을 기반으로 하여, 표준 물질이 존재하지 않아 정량화하기 어려운 복합 성분들의 정성 및 정량 분석의 확장 적용이 가능할 것으로 보인다.

고분자전해질 연료전지에서 기체 크로마토그래프에 의한 수소투과도 측정 (Measurement of Hydrogen Crossover by Gas Chromatograph in PEMFC)

  • 정재진;정재현;김세훈;안병기;고재준;박권필
    • Korean Chemical Engineering Research
    • /
    • 제52권4호
    • /
    • pp.425-429
    • /
    • 2014
  • 최근까지 대부분의 PEMFC MEA(Membrnae and Electrode Assembly) 열화 연구는 전극과 전해질 막 각각 분리되어 연구되었다. 그런데 실제 PEMFC 운전조건에서는 전극과 전해질 막은 동시에 열화된다. 동시열화과정에서 전극열화와 전해질 막 열화는 상호 작용한다. 전해질 막의 열화정도를 측정하는데 수소투과도가 많이 사용되고 있다. 그런데 동시 열화가 발생했을 때 선형 쓸음 전기량 측정법(Linear Sweep Voltammetry, LSV)에 의해 수소투과도를 측정하면 전극열화가 수소투과전류를 감소시키는데, LSV 방법이 전극 촉매의 활성 면적에 의존하기 때문이다. 본 연구에서는 전극과 막 동시 열화과정에서 기체 크로마토그래프에 의한 PEMFC 전해질막의 수소투과도를 측정하였다. 기체 크로마토그래프 측정 방법은 전극 상태와 무관하기 때문에 전극과 막 동시 열화 과정에서 수소투과도가 전극 열화 영향을 받지 않음을 확인하였다.

GC 및 GC/MSD를 이용한 주요 분변 부패산물 신속분석법 (Rapid Analysis of Major Putrefactive Metabolites by GC and GC/MSD)

  • 박규용;김민철;우강융;이나경;백현동
    • KSBB Journal
    • /
    • 제18권1호
    • /
    • pp.74-77
    • /
    • 2003
  • 대표적인 부패산물들로 잘 알려진 indole, skatole, 그리고 $\rho$-cresol 등을 측정하기 위한 방법으로 HPLC, spectrophotometric 법, 그리고 GC 및 GC/MSD 방법 등이 있으며, 수십년 간에 걸쳐 이러한 물질들의 분석이 이루어져 왔다. 본 연구에서는 많은 전처리 과정을 생략하여 분석물의 손실을 최소화하면서 GC 및 GC/MSD를 이용하여 쉽고 빠르게 측정할 수 있는 조건과 방법을 확립하였다. 측정사료는 건강한 성인 남녀의 분변이었으며, 내부 표준물질로 4-isopropylphenol을 사용하였으며, 분변 중 indole의 함량은 10~90 ppm 수준이었으며, skatole의 경우에는 약 40 ppm 정도로 검출되었다. 또한, $\rho$-cresol은 30~300 ppm 수준으로 그 분포 범위가 아주 넓게 나타났었다. GC/MSD를 이용하여 시료 중상기 물질들을 정성적으로 정확히 확인할 수 있었다. DB-17 capillary 컬럼을 이용하여 시료의 전처리 과정을 생략하여도 분석하려던 부패산물의 정성 및 정량에 방해되는 불순 peak는 없었고, 분리능도 매우 우수하였으므로 보다 빠르고 신속하게 상기 물질들을 확인할 수 있었다. 향후 본 연구를 통해 개발된 신속분석법이 분변에 존재하는 주요 부패산물들의 정량에 유용하게 사용되리라 판단된다.

Applicability of Using GC-PDD (Pulsed Discharge Detector) for Multiresidual Pesticides Analysis

  • Oh, Chang-Hwan
    • Food Science and Biotechnology
    • /
    • 제15권6호
    • /
    • pp.959-966
    • /
    • 2006
  • The electron-capture detector (ECD) of gas chromatographs (GC) has been used widely in pesticide analysis. However, as ECD relies on radioactive material, it is troublesome to purchase and maintain. Therefore, potent replacements for ECD were investigated. A Pulsed-discharge detector (PDD) for ECD was tested and the analytical results of PDD (ECD mode), ${\mu}ECD$, and nitrogen-phosphorus detector (NPD) were compared for 107 pesticides including organochroline, organophosphorus, pyrethroids etc. The number of pesticides identified at the lowest limit of detection (LOD) was 36, 29, and 2 for PDD, ${\mu}ECD$, and NPD, respectively. The remaining pesticides showed same response to PDD and ${\mu}ECD$. The GC-PDD analysis of pesticides spiked into representative agricultural products (brown rice, spinach, and mandarin oranges) also showed good and/or equivalent recoveries using $GC-{\mu}ECD$.

GC/AED를 이용한 의료용 액화혼합가스 중 산화에틸렌 및 프레온 가스류의 몰분율 측정 (Determination of the mole fractions of ethylene oxide and freons in medical liquefied gas mixture by GC/AED)

  • 김현주;김달호;임아랑;이택홍;김진석
    • 분석과학
    • /
    • 제25권6호
    • /
    • pp.382-387
    • /
    • 2012
  • 산화에틸렌($C_2H_4O$, Ethylene oxide, EtO)은 에탄올아민 같은 공업적으로 중요한 물질이나 에틸렌 글리콜의 생산 원료 또는 살균제로 이용되는 물질이다. 산화에틸렌은 불화탄화수소를 분사제 또는 바탕가스로 하여 액화혼합가스로 제조되어 열에 약한 의료기기나 저장시설의 소독에 널리 사용되고 있다. 액화혼합가스의 생산 및 사용 시 품질관리 및 안전관리를 위해 각 성분의 몰분율을 정확히 측정할 필요가 있다. 휘발성 액체시료 중 각 기체성분들은 증기압이나 끓는점 등과 같이 물리 화학적 성질이 다르므로 몰분율 측정 시 실린더 내부의 상층에 평형을 이루고 있는 기체시료 또는 하층의 기화되지 않은 액체시료를 직접 측정기기에 주입하는 방법에 따라 측정 결과가 다를 수 있다. 본 연구에서는 액화혼합가스를 액체 또는 기체 상태로 주입할 수 있는 새로운 온라인 시료도입장치를 고안하고 GC/AED (gas chromatograph-atomic emission detector)를 사용하여 산화에틸렌과 불화탄화수소 액화혼합가스를 측정하였으며 AED의 검출특성, 기기에 주입 시 시료의 상태, 측정파장에 따른 측정결과의 정확성 및 반복성을 조사하였다.

인화성액체를 촉진제로 사용한 방화화재의 감식기법에 관한 연구 (Arson Fire Analysis Involving the Use of Flammable Liquilds as Accelerants)

  • 최민기;한동훈;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제28권4호
    • /
    • pp.64-72
    • /
    • 2014
  • 본 연구에서는 연소잔류물에 남아있는 미세한 인화성액체의 성분을 검출하기 위해 가스검지관, Gas Chromatograph/Mass Spectrometer (GC/MS), 열분해분석장비를 활용하였다. 일반적으로 연소했을 경우와 인화성액체를 첨가하여 연소된 경우의 성분분석결과를 비교하였다. 결과적으로 인화성액체를 첨가하지 않고 연소 후 생성된 화재잔해물에서도 가스검지관이 반응하는 것을 확인할 수 있었다. 일반적인 연소와 열분해를 통해 생성된 화학성분의 차이가 있었으며, 이는 연소 환경의 차이로 인한 것으로 판단된다. 대표적인 석유화학제품인 우드데코타일(PVC) 시료는 인화성액체를 첨가하지 않고 일반적으로 연소시켰을 경우에도 감정인의 정확한 판단을 방해할 수 있는 방해물질인 Toluene, Ethylbenzene, Undecane, Dodecane 등이 검출되는 것을 확인하였다.

전자코를 이용한 쇠고기의 신선도 예측 (Estimation of Beef Freshness with Electronic Nose)

  • 김기영;이강진;최규홍;최동수;손재룡
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2002년도 하계 학술대회 논문집
    • /
    • pp.394-399
    • /
    • 2002
  • 국민소득의 증대와 함께 소비자의 고품질 농축산물에 대한 수요와 관심이 날로 증가하고 있다 이에 따라 안전하며 고품질인 농축산물을 소비자에게 공급하기 위하여 안전한 농축산물의 생산, 신선도 유지를 위한 유통구조의 개혁, 품질 및 안전성 평가기술개발을 위한 노력이 보다 더 요구되고 있다. 소비자가 믿고 구매하기 위해서는 농축산물에 대한 품질보증이 필수적이며 이를 위해서는 신속하고 정확한 품질 및 유해물질의 판정기술 개발이 필요하다. 많은 농축산물에 있어서 주요 품질인자인 숙도 및 신선도의 변화는 휘발성 화학물질로 이루어진 냄새의 변화로 나타나므로 이를 측정하여 품질 및 안전성을 간접적으로 판정할 수 있다 기존의 냄새에 의한 품질 판정은 판별전문가에 의한 관능평가법 또는 GC(Gas Chromatography)나 GC/MS(Gas chromatograph mass spectrometer)에 의하여 주로 이루어져 왔다. 하지만, 관능평가법의 경우 판별전문가의 개인적인 차이, 피로, 건강상태 등에 따라 판정의 객관성이 떨어질 우려가 있고, GC나 GC/MS를 이용할 경우 냄새분석에 많은 시간과 노력이 소요되는 문제점이 있다. (중략)

  • PDF

열탁착식 가스크로마토질량분석기에 의한 국내 산지별 백리향의 휘발성향기성분 (Volatile Aroma Compounds of Several Domestic Thymus quinquecostatus by Thermal Desorption Gas Chromatograph Mass Spectrometer)

  • 장매희;이광우;백정애
    • 생물환경조절학회지
    • /
    • 제20권1호
    • /
    • pp.14-20
    • /
    • 2011
  • 지역별로 자생하고 있는 백리향 지상부의 휘발성 향기 성분 및 방부성 물질인 phenols의 성분을 조사하기 위해 제주도 고산종, 제주도 중간산종, 경기도, 울릉도, 강원도 서식종을 TD-GC-MSD로 분석한 결과 제주도 중간산종에서 상대적으로 높은 62종의 물질이 조사되었으며 함량도 $7365.22{\mu}g/m^3$으로 높은 농도를 나타냈다. 또한 백리향의 휘발성 향기성분 중 제주도 중간산종이 다른 조사지역보다 상대적으로 thymol과 carvacrol의 phenol성 물질이 다른 휘발성분에 비해 35.92%로 높은 결과를 보였다.

기체 크로마토그래프-질량분석법을 이용한 뇨중 비스테로이드성 소염진통제 (NSAIDs)의 동시 분석법 (Simultaneous Analysis of Several Non-Steroidal Anti-Inflammatory Drugs in Urine by Gas Chromatograph/Negative Chemical Ionization-Mass Spectrometry)

  • 명승운;박준호;김명수;조현우
    • 분석과학
    • /
    • 제12권6호
    • /
    • pp.571-576
    • /
    • 1999
  • 소변 시료에서 비스테로이드성 소염진통제 (Non-Steroidal Anti-Inflammatory Drugs)인 Fenamates 부류의 6종에 대해서 pentafluoropropionyl 유도체화 반응을 통하여 Gas Chromatograph/Negative Chemical Ionization-Mass Spectrometer에 감응도가 높은 유도체를 만들었다. 6종의 소염 진통제 약물에 대하여 반응성이 좋은 유도체화 반응 조건과 크로마토그래피 조건을 설정하였으며 이들 약물은 동시에 분석 가능하였고 검출한계가 4-25 pg/mL 이어서 경마 경기에서 자주 사용되고 있는 NSAIDs의 미량 성분에 대한 검출 및 법과학에서의 응용이 가능하다.

  • PDF