• 제목/요약/키워드: gap line

검색결과 570건 처리시간 0.029초

진공인터럽터 내부 shield gap에 따른 전계분포해석 (Electric field distribution analysis along shield gap inner vacuum interrupter)

  • 윤재훈;김병철;이승수;임기조;강성화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1368-1369
    • /
    • 2008
  • This paper describes the electric field distribution analysis along a shield form inner vacuum interrupter(VI). The equipotential line and electric field and field vector in a VI are analysed by a finite element method at various shield form. in result, The equipotential line and electric field distribution was affected to VI shield gap. The reason is as it gets distortion of equipotential line done. finally, this paper recognized whether or not affected, and proposed gap with the most suitable shield length and an external insulation.

  • PDF

Role of Gap Junction in the Regulation of Renin Release and Intracellular Calcium in As 4.1 Cell Line

  • Han, Jeong-Hee;Hong, Bing-Zhe;Kwak, Young-Geun;Yuan, Kui-Chang;Park, Woo-Hyun;Kim, Sung-Zoo;Kim, Suhn-Hee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제11권3호
    • /
    • pp.107-112
    • /
    • 2007
  • Gap junction protein, connexin, is expressed in endothelial cells of vessels, glomerulus, and renin secreting cells of the kidney. The purpose of this study was to investigate the role of gap junction in renin secretion and its underlying mechanisms using As 4.1 cell line, a renin-expressing clonal cell line. Renin release was increased proportionately to incubation time. The specific gap junction inhibitor, 18-beta glycyrrhetinic acid (GA) increased renin release in dose-dependent and time-dependent manners. Heptanol and octanol, gap junction blockers, also increased renin release, which were less potent than GA. GA-stimulated renin release was attenuated by pretreatment of the cells with amiloride, nifedipine, ryanodine, and thapsigargin. GA dose-dependently increased intracellular $Ca^{2+}$ concentration, which was attenuated by nifedipine, nimodipine, ryanodine, and thapsigargin. However, RP-cAMP, chelerythrine, tyrphostin A23, or phenylarsine oxide did not induced any significant change in GA-stimulated increase of intracellular $Ca^{2+}$ concentration. These results suggest that gap junction plays an important role on the regulation of renin release and intracellular $Ca^{2+}$ concentration in As 4.1 cells.

인쇄전자를 위한 그라비아 옵셋 인쇄 (Gravure Offset Printing for Printed Electronics)

  • 김충환;최병오;류병순;김동수
    • 한국정밀공학회지
    • /
    • 제25권5호
    • /
    • pp.96-102
    • /
    • 2008
  • Manufacturing of printed electronics using printing technology has begun to get into the hot issue in many ways due to the low cost effectiveness to existing semi-conductor process. This technology, with low cost and high productivity, can make it possible to produce printed electronics such as TFT, solar cell, RFID Tag, printed battery, and so on. In this study, apparatus of gravure-offset printing are developed for fine line-width/gap printing and the results obtained from the apparatus shows that it is possible to make around 20 micro-meter line-width/gap printing patterns. The roll-to-roll printing system for fine line-width printing based on primary experiment is presented. The printing results obtained from the system shows around 30 micro-meter line-width/gap printing patterns.

하악골 골절선상에 위치한 치아의 예후에 관한 연구 (THE PROGNOSIS OF THE TEETH IN THE MANDIBULAR FRACTURE LINES)

  • 송재철;장익준;진병로
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권5호
    • /
    • pp.507-513
    • /
    • 2000
  • Objective : The purpose of this study is to evaluate the vitality of the teeth in and adjacent to the mandibular fracture line according to variable conditions of fracture and to establish the protocol of treatment of fracture line teeth. Materials and Methods : The vitality of 97 teeth in fracture line and 104 teeth adjacent to fracture line of 52 patients were invested preoperatively. Of these, 66 teeth in fracture line and 72 teeth adjacent to fracture line were monitored at least 6 months after operation. An electric pulp tester was used to measure pulpal response. The relationships between the vitality of teeth in variable time(preoperation, immediate post-operation; within 1 week after operation, and 6 months after operation) and variable conditions of fracture(horizontal, vertical gap of fracture line, the number of fracture line)were evaluated statistically. Result : The vitality of fracture line teeth in the 6 months after operation statistically differed by the vertical gap of fracture line and the number of fracture line. The vitality of fracture line adjacent teeth in the immediate post-operation only statistically differed by the vertical gap of fracture line. There were statistically differences between preoperative EPT value and vitality of fracture line teeth on 6 months after operation. There were 5 cases of complications including periapical and periodontal abscess. Of these, only one tooth was extracted and the others were well treated with endodontic treatment and subgingival curettage. Conclusion : It is recommended to retain teeth and to monitor the vitality of teeth in and adjacent to fracture line, unless there is an absolute indication for extraction.

  • PDF

대면적 AMLCD의 신호 지연 감소를 위해 Air-gap을 갖는 게이트-데이터 라인 교차 구조 (A Novel Air-Bridge Type Gate-Data Line Inter-Crossing to Reduce Signal Delay for Large Size AMLCD)

  • 박진우;강지훈;이민철;한민구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권12호
    • /
    • pp.768-772
    • /
    • 1999
  • A new TFT-LCD panel with air-bridge type gate to data line inter-crossing has been proposed and its characteristics have been measured. The proposed structure has air-gap between gate and data line inter-crossing. This air-bridge TFT-LCD panel has very small capacitance between gate and data line. The new panes structure achieves 9 times fast signal propagation compared with conventional panel, which enables to have enough design margin for 20-inch diagonal and larger size UXGA panel. We have examined thermal and mechanical durability of new panel to verify applicability for commercial AMLCD production. After TEOS and polyimide passivation, this panel withstood a thermal stress at $250^{\circ}C$ and a mechanical stress during the rubbing process.

  • PDF

송전선로에 사용되는 갭형 피뢰기 소자의 뇌임펄스 전류특성 (Characteristics of Lightning Impulse Current of Zno Block for Transmission Line Arrester with External Gap)

  • 조한구;유대훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.61-62
    • /
    • 2009
  • This paper describes the characteristics of lightning impulse current of ZnO block for transmission line arrester with external gap. The ageing parameters of lightning arresters ate impulse current, moisture ingress, temperature ageing and so on. Especially it is important to estimate the change of electrical characteristics by impulse current. Total energy applied to the ZnO arrester each time is $4/10{\mu}s$, 30kA and $2/20{\mu}s$, 10kA impulse current. Before and After the test, the residual voltage variation of varistors passed was below 5%. According to the test, it is thought that the ZnO arrester shows good stability with impulse current test.

  • PDF

송전선로에 사용되는 갭형 피뢰기 소자의 뇌임펄스 전류특성 (Characteristics of Lightning Impulse Current of ZnO Block for Transmission Line Arrester with External Gap)

  • 조한구;유대훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.458-459
    • /
    • 2007
  • This paper describes the characteristics of lightning impulse current of ZnO block for transmission line arrester with external gap. The ageing parameters of lightning arresters are impulse current, moisture ingress, temperature ageing and so on. Especially it is important to estimate the change of electrical characteristics by impulse current. Total energy applied to the ZnO arrester each time is $4/10{\mu}s$, 30kA and $2/20{\mu}s$, 10kA impulse current. Before and After the test, the residual voltage variation of varistors passed was below 5%. According to the test, it is thought that the ZnO arrester shows good stability with impulse current test.

  • PDF

Effects of discontinuous submerged breakwater on water surface elevation

  • Ketabdari, Mohammad J.;lamouki, Mohammad Barzegar Paiin;Moghaddasi, Alireza
    • Ocean Systems Engineering
    • /
    • 제5권4호
    • /
    • pp.319-329
    • /
    • 2015
  • Submerged breakwaters are used to prevent shore line erosion and sediment transportation. One of their advantages is low visual impact. In this paper, the effects of discontinuous submerged breakwaters over water surface elevation was numerically studied considering the extended Boussinesq equations as governing equations using MIKE21 software. The result of discontinuous breakwater was compared with a beach without breakwater. The results showed that the gap dramatically effects on surface elevation from shore line to offshore. It is also evident from results that with approaching the center of the gap, fluctuation of surface elevation is generated. It is because of passing longshore currents towards offshore through the gap which leads to an increase in sediment transportation rate. Nevertheless, transferring water mass from breakwater gap results in powerful rip currents leading to high changes on longshore wave profile.

양수발전소 발전-전동기 운전중 감시 시스템의 개발 (Development of On-Line Monitoring System for Pumped Storage Generator/Motor)

  • 김희동;주영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권3호
    • /
    • pp.168-174
    • /
    • 2004
  • On-line monitoring system(OMS) has been developed for the pumped storage generator/motor The OMS is applied to diagnosis of the PD(partial discharge) activity of stator insulation, the shorted-turn of rotor winding and the variation of the air-gap between stator and rotor. The OMS consists of DAS(data acquisition system), main server system, gateway and display PC. The DAS measures the PD, the shorted-turn and air-gap from three sensors installed on the generator/motor. The gateway controls the data which sent by DAS. The main server system saves the data, analyzes the data and conducts the diagnostic algorithm. The display PC shows the diagnostic results of partial discharge, shorted-turn and air-gap. Field tests were conducted using PDA(partial discharge analyzer). The results of the OMS and PDA measurements can be directly correlated with normalized quantity number(NQN), PD magnitude(Qm) and PD pattern.

Dual Damascene 공정에서 Bottom-up Gap-fill 메커니즘을 이용한 Cu Plating 두께 최적화 (Cu Plating Thickness Optimization by Bottom-up Gap-fill Mechanism in Dual Damascene Process)

  • 유해영;김남훈;김상용;장의구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.93-94
    • /
    • 2005
  • Cu metallization using electrochemical plating(ECP) has played an important role in back end of line(BEOL) interconnect formation. In this work, we studied the optimized copper thickness using Bottom-up Gap-fill in Cu ECP, which is closely related with the pattern dependencies in Cu ECP and Cu dual damascene process at 0.13 ${\mu}m$ technology node. In order to select an optimized Cu ECP thickness, we examined Cu ECP bulge, Cu CMP dishing and electrical properties of via hole and line trench over dual damascene patterned wafers split into different ECP Cu thickness.

  • PDF