• 제목/요약/키워드: gap cooling

검색결과 173건 처리시간 0.027초

The Effect of Gap Size on Counter Current Flow Limitation Phenomena in Narrow Annular Gaps with Large Diameter

  • Jeong, Ji-Hwan;Lee, Seung-Jin;Park, Rae-Joon;Kim, Sang-Baek
    • Nuclear Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.396-405
    • /
    • 2002
  • An experimental study on counter-current flow limitation phenomena in narrow annular passages was carried out The gap sizes tested were 1, 2 and 3 mm. This is very small compared with the outer diameter of the annular passage, 500 mm. It was visually observed that a CCFL might occur in some part of the periphery while the other part is remained in a counter current flow pattern. That is, non-uniform behaviour of fluids due 4o a 2-dimensional effect appear in a large diameter facility. Because of this non-uniformity, a CCFL is defined in the present work as the situation where net water accumulation is sustained. That is, some amount of water should not be allowed to penetrate the gap and accumulate over the gap at CCFL criterion. The measured data are presented in the form of Wallis'type correlation with characteristic length of gap size. It was found that the present correlation is in good agreement with other empirical correlation based on measurements whose test section diameter is close and the gap size is much larger than that of the present test section.

라면 면대의 균일한 두께를 위한 압연공정 자동화 (Rolling Process Automation For Uniform Thickness of Dough Sheet of Ramen Noddles)

  • 유동상;유병국
    • 조명전기설비학회논문지
    • /
    • 제26권11호
    • /
    • pp.97-103
    • /
    • 2012
  • The basic processing unit for instant ramen noodles includes mixing, rolling, boiling, frying, cooling, and packing processes. For uniform thickness of dough sheets in rolling process, the roll-gap in rolling process needs to keep uniform thickness of flour sheets in spite of different kinds of raw materials. In this paper, we have developed a roll gap adjustment system using a PLC (Programmable Logic Controller) with a touch panel and an AC servo-mechanism to make dough sheets with a good gluten starch-network structure and uniform thickness and to contribute to process standardization by transferring from tacit knowledge of skilled workers to explicit knowledge. The developed system can adjust the roll gap in units of 0.01mm and correspond to various product items which have different thickness specification by recalling the presetting values of the desired thickness from database.

간극에서의 역방향 유동 제한 현상 연구 (Counter-Current Flow Limit in Narrow Gap)

  • 김용훈;서균렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1054-1060
    • /
    • 1998
  • Previous counter-current flow limitation (CCFL) and critical heat flux (CHF) studies included investigations on the inlet entrance, inclined channel and gap effects for the most part. In this study, the local CHF correlation was presented to be used in the numerical analysis for the 3 dimensional hemispherical geometry. Also, first-principle analyses were performed to determine the maximum heat removal capability from the debris through the gap that may be formed during a core melt accident. The maximum heat removal capability by gap cooling can be applied in quantitatively assessing the severe accident management measures.

  • PDF

간극에서의 역방향 유동 제한 현상 연구 (Counter-Current Flow Limit in Narrow Gap)

  • 김용훈;서균렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.706-712
    • /
    • 1998
  • Previous counter-current flow limitation (CCFL) and critical heat flux (CHF) studies included investigations on the inlet entrance, inclined channel and gap effects for the most part. In this study, the local CHF correlation was presented to be used in the numerical analysis for the 3 dimensional hemispherical geometry. Also, first-principle analyses were performed to determine the maximum heat removal capability from the debris through the gap that may be formed during a core melt accident. The maximum heat removal capability by gap cooling can be applied in quantitatively assessing the severe accident management measures.

  • PDF

간극에서의 역방향 유동 제한 현상 연구 (Counter-Current Flow Limit in Narrow Gap)

  • 김용훈;서균렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.386-392
    • /
    • 1998
  • Previous counter-current flow limitation (CCFL) and critical heat flux (CHF) studies included investigations on the inlet entrance, inclined channel and gap effects for the most part. In this study, the local CHF correlation was presented to be used in the numerical analysis for the 3 dimensional hemispherical geometry. Also, first-principle analyses were performed to determine the Maximum heat removal capability from the debris through the gap that may be formed during a core melt accident. The maximum heat removal capability by gap cooling can be applied in quantitatively assessing the severe accident management measures.

  • PDF

초음파 진동자에 의해 유도된 음향유동을 이용한 첨단 냉각법 (A Novel Cooling Method by Acoustic Streaming Induced by Ultrasonic Resonator)

  • 노병국;이동렬
    • 한국음향학회지
    • /
    • 제22권3호
    • /
    • pp.217-223
    • /
    • 2003
  • 30 ㎑의 초음파 (ultrasonic wave)의 미세 진동에 의해서 유도된 음향유동 (acoustic streaming)에 의한 공기대류를 이용한 새로운 냉각방법을 소개한다. 초음파 진동은 압전소자 (piezoelectric device)에 의해서 얻어지며 50 m 정도의 진동진폭을 얻기 위해 기계적 진동 증폭자인 혼 (horn)을 추가하여 전체 진동 시스템이 공진하도록 구성된다. 음향유동에 의한 열전달 효과의 상승을 측정하기 위해 열원 (heat source) 및 열원 주위의 대기의 온도변화를 실시간으로 측정하였다. 초음파 진동 시작 후 시간지연 없이 음향유동이 유도되어 진동자 주위의 대량의 공기유동으로 인한 급격한 온도감소가 관찰되었다. 또한 열원과 진동자와의 거리가 방사 (radiation)되는 음파 (sound wave)의 반파장 (half wave length)의 정배수가 될 때 열원의 냉각효과가 극대화됨을 실험적으로 관찰하였다. 이는 음파의 공진현상에 기인한 것으로 이론적 고찰을 통한 검증 또한 수행되었다. 음향유동을 이용한 냉각법의 장점은 초음파 진동을 이용하기 때문에 무소음이며 이동 형태의 부품이 없기 때문에 반영구적으로 사용할 수 있다. 또한 기존의 전기모터를 이용한 냉각팬 (cooling fan)으로는 냉각이 어려운 초소형 기전시스템 (MEMS)의 냉각법으로 사용될 수 있는 첨단 냉각방법이다.

상부가 개방된 수직 캐비티내에 장착된 불연속 균일 발열체의 자연대류 냉각 (Natural convection cooling of discrete heaters with same heat generation in a vertical open top cavity)

  • 유갑종;추홍록;김병하;최병철
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.1-14
    • /
    • 1997
  • Natural convection cooling of discrete heaters located in a two-dimensional vertical open top cavity is investigated experimentally. The five discrete heaters with same heat generation are located on the wall of the cavity. The heaters are arranged in two configurations; flush-mounted on a vertical wall and protruding from the wall about 4.5 mm. The materials used for the vertical walls are copper and epoxy-resin, and air is used as the cooling fluid. The temperature and flow fields in the cavity were visualized by means of Mach-Zehnder interferometer and smoke-method. Also, local temperature measurements are made along the vertical wall. Results are obtained for cavity aspect ratios of 4.6, 7.5 and 9.5 and modified Rayleigh numbers ranging from 10$^{3}$ to 10$^{6}$ . Results indicate that the cooling efficiency for the copper wall is superior to that of the epoxy-resin. For the epoxy-resin wall, the protrusion of the heaters plays a role in decreasing the heat transfer performance. The location of maximum temperature is significantly influenced by the wall materials and heater configurations. Correlations relating the Nusselt number to the modified Rayleigh number are proposed.

학교건물 냉난방설비시스템의 실태조사 (Evaluation of the Heating and Cooling Systems in School Buildings)

  • 안철린;김동규;금종수;박종운;박희욱;정용현
    • 수산해양교육연구
    • /
    • 제17권1호
    • /
    • pp.18-25
    • /
    • 2005
  • We have researched 10,811 schools to evaluate the characteristics of school buildings and the conditions of heating and cooling systems at the elementary, middle and high school levels. Air conditioning systems in school buildings are related to school scale, and 35% of the researched schools have less than 10 air conditioned classrooms among all of the schools in Korea. The LOADSYS is used to grasp the characteristics of school buildings heating and cooling load. From the results of this work, the heating load differs by nearly 24% between Seoul and Busan, but other than that there are not so many serious regional differences. Almost 85.4% of the classrooms are equipped with heating facilities and 6.9% of them are equipped with heating and cooling facilities. As a result, it is necessary to make improvements in 31.8% of the classrooms using only heaters and 14.6% of the classrooms not equipped with HVAC. The survey shows that there is a wide gap in the heating equipment status of the classrooms according to the region and school district.

충돌제트/유출냉각기법에서 횡방향유동이 열/물질전달에 미치는 영향 (Effect of Crossflow on Heat (Mass) Transfer of an Impingement/Effusion Cooling System)

  • 남용우;최종현;조형희;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2219-2226
    • /
    • 2003
  • Two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of the hole diameter, and initial crossflow passes between the plates. Both the injection and effusion hole diameters are 10 mm, and the Reynolds number based on the hole diameter and hole-to-hole pitch are fixed to 10,000 and 6 times of the hole diameter, respectively. To investigate the effect of crossflow, the flow rate of crossflow is changed from 0.2 to 2 times of that of the impinging jet. A naphthalene sublimation method is used to determine the local heat/mass transfer coefficients on the upward facing surface of the effusion plate. With the initial crossflow, the heat/mass transfer rates on the effusion (target) plate decrease as the velocity of crossflow increases, since the crossflow induces the locally low transfer regions formed at the mid-way between the effusion holes. However, the impingement/effusion cooling with crossflow presents higher heat/mass transfer rates than the array jet impingement cooling with the same initial crossflow.

  • PDF

예압과 냉각조건에 따른 고주파 모터 내장형 주축계의 열특성 (Thermal Characteristics of the High Frequency Motor Spindle according to the Bearing Preloads and Cooling Conditions)

  • 최대봉;김수태;정성훈;김진한;김용기
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.138-143
    • /
    • 2005
  • The important problem in the high speed spindles is to reduce and minimize the thermal effect by the motor and ball bearings. Thermal characteristics according to the bearing preload and hollow shaft cooling are studied for the spindle with the oil mist lubrication and high frequency motor. Temperature distribution and thermal deformation according to the spindle speed, preload and flow rate are measured by thermocouple and gap sensor. Temperature distribution and thermal deformation are analyzed by using the finite element method. The results of analysis are compared with the measured data. This paper show that the suitable preload and hollow shaft cooling are very effective to minimize the thermal effect by the motor and ball bearings. This study indicates that temperature distribution and thermal deformation of the high speed spindle system can be estimated reasonably by using the three dimensional model through the finite element method and supports thermal optimization and more effective cooling method.

  • PDF