• Title/Summary/Keyword: gamma-spectrometer

Search Result 111, Processing Time 0.026 seconds

Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

  • Jeong, Meeyoung;Lee, Kyeong Beom;Kim, Kyeong Ja;Lee, Min-Kie;Han, Ju-Bong
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.317-323
    • /
    • 2014
  • Odyssey, one of the NASA's Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe) detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA) method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA) method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of $^{40}K$, $^{232}Th$ and $^{238}U$ in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl) and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

Large-volume and room-temperature gamma spectrometer for environmental radiation monitoring

  • Coulon, Romain;Dumazert, Jonathan;Tith, Tola;Rohee, Emmanuel;Boudergui, Karim
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1489-1494
    • /
    • 2017
  • The use of a room-temperature gamma spectrometer is an issue in environmental radiation monitoring. To monitor radionuclides released around a nuclear power plant, suitable instruments giving fast and reliable information are required. High-pressure xenon (HPXe) chambers have range of resolution and efficiency equivalent to those of other medium resolution detectors such as those using NaI(Tl), CdZnTe, and $LaBr_3:Ce$. An HPXe chamber could be a cost-effective alternative, assuming temperature stability and reliability. The CEA LIST actively studied and developed HPXe-based technology applied for environmental monitoring. Xenon purification and conditioning was performed. The design of a 4-L HPXe detector was performed to minimize the detector capacitance and the required power supply. Simulations were done with the MCNPX2.7 particle transport code to estimate the intrinsic efficiency of the HPXe detector. A behavioral study dealing with ballistic deficits and electronic noise will be utilized to provide perspective for further analysis.

Soil and Coal Radioactivity around Zuunmod Town of Mongolia

  • Erkhembayar, Ts.;Norov, N.;Khuukhenkhuu, G.;Oyunchimeg, Ts.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.501-505
    • /
    • 2002
  • The specific radioactivity concentrations of $\^$238/U, $\^$232/Th, $\^$40/K were measured in soil samples around Zuunmod town of Mongolia using HP-Ge gamma-spectrometer. Also the specific radioactivity concentrations of above elements were measured in coal and ash samples which were collected from the Central steam heating in Zuunmod town. It was determined the effective equivalent dose.

  • PDF

Measurement of Branching Ratio for broad 27-keV Resonance of $^{19}F(n,g)^{20}F$ Reaction by using Time-of-flight Method with Anti-Compton NaI(Tl) Spectrometer

  • Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.1
    • /
    • pp.31-34
    • /
    • 2008
  • The neutron capture spectrum for the light nuclide was very useful to study the nuclear structure. In the present study, the capture gamma-ray from the 27-keV resonance of $^{19}F(n,g)^{20}F$ reaction were measured with an anti-Compton NaI(Tl) spectrometer and the 3-MV Pelletron accelerator of the Research Laboratory for Nuclear Reactors at the Tokyo institute of technology. A neutron Time-of-Flight method was adopted with a 1.5 ns pulsed neutron source by the $^7Li(p,n)^7Be$ reaction. In the present experiment, a Teflon(($CF_2$)n) sample was used The sample was disk with a diameter of 90mm. The thickness of sample was determined so that reasonable counting rates could be obtained and the correction was not so large for the self-shielding and multiple scattering of neutrons in the sample, and was 5mm. The primary gamma-ray transitions were compared with previous measurement of Kenny.

  • PDF

Design of Neutron Shielder for Reducing Background of Low Level Gamma Ray Spectrometer (극저준위 감마선 분광시스템의 백그라운드 저감화를 위한 중성자 차폐체 설계)

  • Kim, Tae-Wook;Park, Jong-Mook;Park, Jong-Gil;Shin, Sang-Woon;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.67-71
    • /
    • 2001
  • In order to shield the neutrons affecting the background of Low Level Gamma Ray Spectrometer, a neutron shielder was designed. The method used in this study for neutron shielding was the deceleration of fast neutrons by high density polyethylene(HDPE) and the absorption of those slowing-down neutrons by $B_4C$. The calculation results of neutron Interaction in HDPE using Monte Carlo simulation code MCNP4B showed that the thermal-neutron flux was maximum at 10 cm thickness of HDPE. The results also showed that 95% of the thermal neutrons were absorbed by 2 mm thickness of $B_4C$ absorber Consisted of 30 w% $B_4C$ and 70 w% polymer. The results of the Monte Carlo calculation were in good agreement with the experimental value obtained by a neutron shielding apparatus designed for this purpose.

  • PDF

Quality Control of Radiation Counting Systems and Measurement of Minimum Delectable Activity (방사선 계측기의 품질관리 및 최소검출방사능 측정)

  • 송병철;한성심;김영복;지광용;손세철
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.419-424
    • /
    • 2004
  • Various radiation counters have been using to determine radioactivity of radwastes for disposal. A radiation counting system was set up using a radiation detector chosen in this study and its stability was investigated through the periodic determination of background and counting efficiencies in accordance with a quality control program to increase the confidence level. The average background level for the $\gamma$-spectrometer was 1.59 cps and the average counting level for the standard sample was 45248 Ops within $2{\sigma}$ confidence levels. The average alpha background level for the low background ${\alpha}{\beta}$ counting system was 0.31 cpm and the efficiency for alpha counting was 34.38%. The average beta background level for the ${\alpha}{\beta}$ counting system was 1,30 cpm and the efficiency for beta counting was 46.5%, The background level in the region of 3H and 14C for the liquid scintillation counting system was 2.52 and 3.31 cpm and the efficiency for alpha counting was 58.5 and 95.6%, respectively. The minimum detectable activity for the$\gamma$-spectrometer was found to be 3.2 Bq/$m\ell$ and 3.8 Bq/$m\ell$ for the liquid scintillation counter, and 20.5 and 23.0 Bq/$m\ell$, respectively for the $\alpha$ and $\beta$ counting system.

  • PDF

Measurement of Energy Dependent Neutron Capture Cross Sections of $^{197}Au$ in Energy Region from 0.1 eV to 10 keV using a Lead Slowing-down Spectrometer

  • Yoon, Jung-Ran
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.29-32
    • /
    • 2010
  • The neutron capture cross section of $^{197}Au$ has been measured relative to the $^{10}B(n,{\gamma})$ standard cross section by the neutron time-of-flight(TOF) method using a 46-MeV electron linear accelerator(linac) at the Research Reactor Institute, Kyoto University(KURRI). In order to experimentally prove the result obtained, the supplementary cross section measurement has been made from 0.1 eV to 10 keV using the Kyoto University Lead slowing-down spectrometer (KULS) coupling to the linac. The relative measurement by the TOF method has been normalized to the reference value(24.5 b) at 1 eV. The evaluated capture cross sections in JENDL/D-99 Dosimetry have been compared with the current measurements by the KULS experiments.

Development of Anticosmic Shielded Ultra Low Background Gamma Spectrometer for Precise Measurement of Environmental Radioactivity

  • Byun, Jong-In;Park, Yun-Ho;Kwak, Seung-Im;Hwang, Han-Yull;Chung, Kun-Ho;Park, Gun-Sik;Park, Doo-Won;Lee, Chnag-Woo
    • Nuclear Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.545-552
    • /
    • 2002
  • We developed an ultra low background gamma ray spectrometer particularly suitable for experiment which require lower detection limit. The background of a germanium spectrometer is suppressed by applying active and passive shielding technique at the same time. The active shielding devices consist of plastic scintillating plates of 50 mm thick and anti-coincidence electronic system. The shielding is made of 150 mm thick walls of very low activity lead,20 mm with activity of <10 Bq/kg and 130 mm with activity of <50 Bq/kg. The observed background count rates are 1.2 $s^{-1}$ and 0.36 $s^{-1}$ without and with the active shielding, respectively, overall the energy regions from 30 keV to 3 MeV The cosmic ray induced background is suppressed by a rate of 0.8 $s^{-1}$ at the present work. The detection efficiency curve necessary to obtain the radioactivity of environmental samples has been precisely determined on the energy regions from 80 to 2000 keV with a 10$^3$ ml marinelli beaker sample, consisting of the calibrated radionuclides $^{109}$ Cd, $^{57}$ CO, $^{139}$ Ce, $^{203}$ Hg, $^{113}$ Sn, $^{85}$Sr, $^{137}$ Cs, $^{60}$ Co and $^{88}$ Y. Virtues Of the method are demonstrated by measuring the activity of $^{137}$ Cs contained in the powdered milk.

Measurement of Neutron Capture Gamma-ray Spectrum of Natural Gold in the keV Energy Region

  • Lee, Jae-Hong;Lee, Sam-Yol;Lee, Sang-Bock;Lee, Jun-Haeng;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.45-49
    • /
    • 2007
  • keV-neutron capture gamma-ray spectrum of $^{197}Au$(natural gold) sample have been measured in neutron energy range from 10 to 90 keV using the 3-MV pelletron accelerator of the Research Laboratory for Nuclear Reactors at the Tokyo Institute of Technology. Pulsed keV neutrons were produced from the $^7Li(p,n)^7Be$ reaction by bombarding on the $^7Li$ target with the 1.5-ns bunched proton beam. The incident neutron spectrum on the Au sample was measured by a $^6Li$-glass scintillation detector and TOF method. Capture gamma-rays from Au sample were measured by anti-Compton NaI(TI) spectrometer. Five average neutron energy regions were selected to obtain the neutron capture spectrum. Several gamma-ray peaks in the spectrum were found in the present experiment.

  • PDF