• Title/Summary/Keyword: gamma-radiation dose rate

Search Result 348, Processing Time 0.031 seconds

Influence of Low Dose Gamma Radiation on the Growth of Maize(Zea mays L.) Varieties (옥수수 생육에 미치는 저선량 감마선 조사효과)

  • Kim, Jae-Sung;Lee, Young-Keun;Park, Hong-Sook;Back, Myung-Hwa;Kim, Dong-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.4
    • /
    • pp.328-331
    • /
    • 2000
  • Maize (Zea mays L. cv. kosungjaerae and cv. youngwoljaerae) seeds were irradiated with the dose of $0.5{\sim}20$ Gy by $^{60}Co\;{\gamma}-ray$ radiation to investigate the effect of the low dose ${\gamma}-ray$ radiation on the germination rate, early growth and yield. The low dose radiation was able to improve the germination rate and early growth in maize, but the optimal radiation doses were different depended on kinds of cultivars. High stimulatory effect in early growth of maize was observed in 2 Gy irradiation group of kosungjaerae cultivar and in 12 Gy irradiation group of youngwoljaerae cultivar. The optimal radiation dose for the enhancement of yield and yield components in maize was 8 Gy in kosungjaerae cultivar and $4{\sim}12$ Gy in youngwoljaerae cultivar.

  • PDF

Dosimetric Evaluation of an Automatically Converted Radiation Therapy Plan between Radixact Machines

  • Lee, Mi Young;Kang, Dae Gyu;Kim, Jin Sung
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.153-162
    • /
    • 2020
  • Purpose: We aim to evaluate the accuracy and effectiveness of an automatically converted radiation therapy plan between Radixact machines by comparing the original plan with the transferred plan. Methods: The study involved a total of 20 patients for each randomly selected treatment site who received radiation treatment with Radixact. We set up the cheese phantom (Gammex RMI, Middleton, WI, USA) with an Exradin A1SL ion chamber (Standard Imaging, Madison, WI, USA) and GAFCHROMIC EBT3 film (International Specialty Products, Wayne, NJ, USA) inserted. We used three methods to evaluate an automatically converted radiation therapy plan using the features of the Plan transfer. First, we evaluated and compared Planning target volume (PTV) coverage (homogeneity index, HI; conformity index, CI) and organs at risk (OAR) dose statistics. Second, we compared the absolute dose using an ion chamber. Lastly, we analyzed gamma passing rates using film. Results: Our results showed that the difference in PTV coverage was 1.72% in HI and 0.17% in CI, and majority of the difference in OAR was within 1% across all sites. The difference (%) in absolute dose values was averaging 0.74%. In addition, the gamma passing rate was 99.64% for 3%/3 mm and 97.08% for 2%/2 mm. Conclusions: The Plan transfer function can be reliably used in appropriate situations.

Dose Estimation Model for Terminal Buds in Radioactively Contaminated Fir Trees

  • Kawaguchi, Isao;Kido, Hiroko;Watanabe, Yoshito
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.3
    • /
    • pp.143-151
    • /
    • 2022
  • Background: After the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident, biological alterations in the natural biota, including morphological changes of fir trees in forests surrounding the power plant, have been reported. Focusing on the terminal buds involved in the morphological formation of fir trees, this study developed a method for estimating the absorbed radiation dose rate using radionuclide distribution measurements from tree organs. Materials and Methods: A phantom composed of three-dimensional (3D) tree organs was constructed for the three upper whorls of the fir tree. A terminal bud was evaluated using Monte Carlo simulations for the absorbed dose rate of radionuclides in the tree organs of the whorls. Evaluation of the absorbed dose targeted 131I, 134Cs, and 137Cs, the main radionuclides subsequent to the FDNPP accident. The dose contribution from each tree organ was calculated separately using dose coefficients (DC), which express the ratio between the average activity concentration of a radionuclide in each tree organ and the dose rate at the terminal bud. Results and Discussion: The dose estimation indicated that the radionuclides in the terminal bud and bud scale contributed to the absorbed dose rate mainly by beta rays, whereas those in 1-year-old trunk/branches and leaves were contributed by gamma rays. However, the dose contribution from radionuclides in the lower trunk/branches and leaves was negligible. Conclusion: The fir tree model provides organ-specific DC values, which are satisfactory for the practical calculation of the absorbed dose rate of radiation from inside the tree. These calculations are based on the measurement of radionuclide concentrations in tree organs on the 1-year-old leader shoots of fir trees. With the addition of direct gamma ray measurements of the absorbed dose rate from the tree environment, the total absorbed dose rate was estimated in the terminal bud of fir trees in contaminated forests.

A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber using Fiber Bragg Grating Sensor Systems (광섬유 브래그 격자 센서를 이용한 국내외 상용 단일모드 광섬유의 감마선 영향 연구)

  • Kim, Jong-Yeol;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2287-2292
    • /
    • 2012
  • In this study, $Co^{60}$ gamma-ray induced loss on Ge-doped single mode (SM) fiber has been measured. Gamma-ray is irradiated for 4 hours at the dose rate of 0.5 kGy/hr, 2 kGy/hr, 8 kGy/hr. Consequently, gamma-ray induced loss based on radiation effects in Ge-doped SM fiber occur significantly. Furthermore, dose rate effect was observed, that dose rate using the same total dose increased higher, then optical fiber loss increased more. Also annealing effect was observed, that the loss after irradiation, increased higher, then the recovery rate of loss was increased. This results are foreseen to be base data in the future radiation-hardened optical fiber study.

Study on the Thermal Properties of the Gamma-ray Irradiated EVA/MWCNT Nanocomposites

  • Lee, Kyoung-Yong;Kim, Ki-Yup;Hwang, In-Ra
    • Journal of Radiation Industry
    • /
    • v.3 no.1
    • /
    • pp.31-37
    • /
    • 2009
  • This paper describes the preparation of manufacturing a new nanocomposite material, which involves adding a multi walled carbon nanotube (MWCNT) to improve thermal characteristics of poly (ethylene-co-vinyl acetate) (EVA). We irradiated the prepared nanocomposites with doses of 50 kGy, 100 kGy and 200 kGy at a dose rate of $5kGy\;hr^{-1}$ and examined their thermal stability, activation energy and crosslink level by using a thermogravimetric analyzer (TGA) and gel fraction experiments. TGA results indicated that the samples with a MWCNT had higher Derivative Thermo Gravimetry (DTG) 2nd peak temperatures than those without a MWCNT. And activation energy of the samples reduced as the absorption dose and the MWCNT content increased. Finally, the gel fraction increased rapidly up to 100 kGy as total absorption dose increased, and then the growth rate of all samples was slowly increased from 100 kGy.

A Review of Dose Rate Meters as First Responders to Ionising Radiation

  • Akber, Aqeel Ahmad;Wiggins, Matthew Benfield
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.97-102
    • /
    • 2019
  • Background: Dose rate meters are the most widely used, and perhaps one of the most important tools for the measurement of ionising radiation. They are often the first, or only, device available to a user for an instant check of radiation dose at a certain location. Throughout the world, radiation safety practices rely strongly on the output of these dose rate meters. But how well do we know the quality of their output? Materials and Methods: This review is based on the measurements 1,158 commercially available dose rate meters of 116 different makes and models. Expected versus the displayed dose patterns and consistency was checked at various dose rates between $5{\mu}Gy{\cdot}h^{-1}$ and $2mGy{\cdot}h^{-1}$. Samples of these meters were then selected for further investigation and were exposed to radiation sources covering photon energies from 50 keV to 1.5 MeV. The effect of detector orientation on its reading was also investigated. Rather than focusing on the angular response distribution that is often reported by the manufacturer of the device, this study focussed on the design ergonomics i.e. the angles that the operator will realistically use to measure a dose rate. Results and Discussion: This review shows the scope and boundaries of the ionising radiation dose rate estimations that are made using commonly available meters. Observations showed both inter and intra make and model variations, occasional cases of instrument failure, instrument walk away, and erroneous response. Conclusion: The results indicate the significance of selecting and maintaining suitable monitors for specific applications in radiation safety.

Assessment of Gamma-radiation dose Rate in the Ogcheon Lower Phyllite Area, Goesan County, Korea, Using Gamma-ray Spectrometry (감마선분광분석기를 이용한 괴산 옥천하부천매암대 일대의 감마선량 평가)

  • Yun, Uk;Cho, Byong-Wook
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.461-468
    • /
    • 2019
  • Gamma-radiation dose rates were measured at 77 points around the Ogcheon lower phyllite zone (og2) in Goesan County, Korea, using gamma-ray spectrometry. Sample K contents were in the range 1.8-8.8% (average 4.6%), highest in Kgr. The eU contents were 0.2-217.9 ppm (average 16.7 ppm), highest in og2 (median 29.6 ppm). The eTh contents were 11.9-76.5 ppm (average 29.5 ppm) and the average eTh content of Kgr was 45.4 ppm, higher than those of Ogcheon meta-sedimentary rocks (og1, og2, and og3) (26.6-30.6 ppm). Except for some high-uranium sites in og2, 40K is the main radioactive material contributing to the gamma-radiation dose in the study area. Our results indicate that the outdoor effective dose rate of the area is 0.08-1.71 mSv y-1 (average 0.28 mSv y-1), with most areas apart from three points in og2 displaying dose rates <1 mSv y-1, which is the normal natural radiation background level.

Feasibility of Improving the Accuracy of Dose Calculation Using Hybrid Computed Tomography Images: A Phantom Study

  • Jeon, Hosang;Kim, Dong Woon;Joo, Ji Hyeon;Ki, Yongkan;Kim, Wontaek;Park, Dahl;Nam, Jiho;Kim, Dong Hyeon
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.18-24
    • /
    • 2021
  • Purpose: Kilovoltage computed tomography (kV-CT) is essential for radiation treatment planning. However, kV-CT images are significantly distorted by artifacts when a metallic prosthesis is present in the patient's body. Thus, the accuracies of target delineation and treatment dose calculation are inevitably lowered. We evaluated the accuracy of the calculated doses using an image restoration method with hybrid CT, which was introduced in our previous study. Methods: A cylindrical phantom containing four metals, namely, silver, copper, tin, and tungsten, was scanned using kV-CT and megavoltage CT to produce hybrid CT images. We created six verification plans for three head and neck patients on kV-CT and hybrid CT images of the phantom and calculated their doses. The actual doses were measured with film patches during beam delivery using tomotherapy. We used the gamma evaluation method to compare dose distribution between kV-CT and hybrid CT with three gamma criteria, namely, 3%/3 mm, 2%/2 mm, and 1%/1 mm. Results: The gamma pass rates decreased as the gamma criteria were strengthened, and the pass rate of hybrid CT was higher than that of kV-CT in all cases. When the 1%/1 mm criterion was used, the difference in gamma pass rates between them was up to 13%p. Conclusions: According to our findings, we expect that the use of hybrid CT can be a suitable approach to avoid the effect of severe metal artifacts on the accuracy of dose calculation and contouring.

Effects of Low Dose Gamma Radiation on the Early Growth of Pepper and the Resistance to Subsequent High Dose of Radiation (저선량 방사선이 고추의 초기생육과 후속고선량 내성에 미치는 영향)

  • 김재성;백명화;김동희;이영근;이영복
    • Korean Journal of Environmental Biology
    • /
    • v.19 no.1
    • /
    • pp.71-77
    • /
    • 2001
  • Pepper (Capsicum annuum L. cv. Jokwang and cv. Johong) seeds were irradiated with the doses of 0-50 Gy to investigate the effect of the low dose ${\gamma}$-radiation on the early growth and resistance to subsequent high dose of radiation. Following effect was observed in Johong cultivar but not in Jokwang cultivar Germination and early growth rate of Johong cultivar were noticeably increased at 4, 8 and 20 Gy irradiation group. Resistance to subsequent high dose of radiation of Johong cultivar increased at almost all of the low dose irradiation group. Especially it was highest at 4 Gy irradiation group. Plant groups of Johong cultivar showing the resistance to subsequent high dose of radiation, which had been pre-irradiated with 4 Gy and 8 Gy, were also higher in the carotenoid contents and enzyme activity than the plant group not irradiated previously.

  • PDF