• Title/Summary/Keyword: gamma ray dose

Search Result 479, Processing Time 0.036 seconds

Induction of Micronuclei in Human and Mouse Lymphocytes Irradiated with Gamma Radiation and Effect of Panax ginseng C.A. Meyer (마우스와 사람 림프구에서 방사선에 의한 미소핵의 형성 및 고려인삼의 효과)

  • Kim, Sung-Ho;Oh, Heon;Lee, Song-Eun;Lee, Yun-Sil;Kim, Tae-Hwan;Jeong, Kyu-Sik;Ryu, Si-Yun
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.153-160
    • /
    • 1997
  • The frequencies of ${\gamma}$-ray-induced micronuclei (MN) in cytokinesis-blocked (CB) lymphocytes at several doses were measured in three donors of human and C57BL/6 mice. Measurements performed after irradiation showed a dose-related increases in MN frequency in each of the donors studied. The relative sensitivity of mouse in spleen lymphocytes (SLs) compared with human peripheral blood lymphocytes (PBLs) was estimated by best fitting linear-quadratic model based on the radiation-induced MN data over the range from 0 cGy to 400 cGy. In the case of MN frequency with 0.2 per CB cell, the relative sensitivity of mouse SLs was 1.67. Compared with the radiation-induced MN formation in the PBLs of human, the SLs of mouse were more radiosensitive. Using this MN assay with human PBLs and mouse SLs, studies were performed to determine whether the water fraction of ginseng (Panax ginseng C.A.Meyer) against radiation-induced MN in human PBLs after in vitro irradiation (3Gy) and in SLs of C57BL/6 mice after in vivo irradiation (3Gy). The frequency of MN in human PBLs was reduced by water fraction of ginseng (0.5mg/ml of medium) both pre-and post treatment (p<0.0l) in vitro. In addition, the frequency of MN in mouse SLs was also reduced by pretreatment of ginseng (2mg/ml of drinking water for 7days) in vivo. The data suggested that the ginseng may reduce cell damage caused by ${\gamma}$-rays in vitro and in vivo. Further studies are needed to characterize better the protective nature of ginseng extract, its fractions and compounds.

  • PDF

Effect of Irradiation Temperature on Physicochemical and Sensory Properties of Tarakjuk (Milk Porridge) (방사선 조사 온도가 타락죽의 이화학적 및 관능적 품질 특성에 미치는 영향)

  • Han, In-Jun;Song, Beom-Seok;Lee, Ju-Woon;Kim, Jae-Hun;Choi, Kap-Sung;Park, Jeong-Ro;Chun, Soon-Sil
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.9
    • /
    • pp.1307-1313
    • /
    • 2011
  • This study was conducted to evaluate the effects of irradiation temperature on the physicochemical and sensory properties of Tarakjuk, milk porridge. Tarakjuk was gamma-irradiated at different temperatures of $25^{\circ}C$ (in room), $4^{\circ}C$ (in ice), and $-20^{\circ}C$ (in dry ice) at a dose of 10 kGy, and then autoclaved at $120^{\circ}C$ for 15 min for comparison. pH and Hunter's color value of Tarakjuk were not changed by irradiation regardless of the temperature. However, the TBA (2-thiobarbituric acid) value decreased as irradiation temperature was decreased. The viscosity of Tarakjuk irradiated in dry ice was significantly higher than that irradiated at room temperature and in ice (p<0.05). For the sensory evaluation, there were no significant differences in overall acceptability between non-treated Tarakjuk and that irradiated in dry ice. Flavor pattern analysis using an electronic nose with a SAW (surface acoustic wave) sensor determined that the main peaks at retention times 3.88 and 7.34 sec were related with off-flavor induced by irradiation and unique flavor of Tarakjuk, respectively. These results indicated that irradiation at freezing temperature improved quality deterioration of Tarakjuk by gamma irradiation. However, sensory quality of Tarakjuk irradiated at freezing temperature was still lower than that of non-irradiated Tarakjuk. Therefore, further research is needed to improve the quality of Tarakjuk using combined treatment such as addition of antioxidants and vacuum packaging method.

Evaluation of Radiation effective dose by Naturally Radionuclides in the Soil of Busan (부산지역 토양 내 천연방사성핵종 분석 및 유효선량율 평가)

  • Kim, Jung-Hoon;Kim, Chang-Soo;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3658-3666
    • /
    • 2014
  • The presence of $^{238}U$, $^{232}Th$ and $^{40}K$, which are naturally residing radionuclides, in the ordinary soil of Busan, the 2nd largest city in Korea, was anlayzed and the residents' radiation exposure to ordinary soil was evaluated. Regarding the measurement methods, to conduct a detailed analysis of the naturally residing radionuclides in the soil of Busan, this study divided the 16 administrative districts into a lattice structure with 3 spots, and collected a total of 48 soil samples (July 2012 and April 2013). ICP-MS was used to analyze the concentration of the radioactivity of $^{238}U$ and $^{232}Th$ in the soil, and a HpGe detector, a gamma ray detector, was used to analyze the radioactivity of $^{40}K$. The measurement values of this study were compared with the concentration of radioactivity of East Asian regions. The concentration of $^{238}U$ nuclides in Korea was lower than the mean, whereas the concentration of $^{232}Th$ and $^{40}K$ nuclides was higher than the mean. The higher mean concentrations of $^{232}Th$ and $^{40}K$ than the mean were attributed to the many granite areas that contain a great deal of naturally occurring radionuclides.

Incidence of Micronuclei in Lymphocytes of Cattle in the High Background Radiation Area (자연방사선 고준위 지역 사육 소의 림프구 미소핵 발생 평가)

  • Lee, Hae-June;Kang, Chang-Mo;Kim, Se-Ra;Moon, Chang-Jong;Kim, Jong-Choon;Kim, Ill-Hwa;Jo, Sung-Kee;Jang, Jong-Sik;Kim, Sung-Ho
    • Toxicological Research
    • /
    • v.22 no.4
    • /
    • pp.417-422
    • /
    • 2006
  • Cytogenetic and hematological analysis was performed in peripheral blood obtained from cattle bred in the high background radiation areas (HBRA, Goesan-gun, Cheongwon-gun, Boeun-gun) and a control area. The frequencies of gamma-ray induced micronuclei (MN) in the cytokinesis-blocked (CB) lymphocytes at several doses were measured in 3 cattle. An estimated dose of radiation was calculated by a best fitting linear-quadratic model based on the radiation-induced MN formation from the bovine lymphocytes exposed in vitro to radiation over the range from 0 mGy to 1,969 mGy. The measurements performed after irradiation showed dose-related increases in the MN frequency in each donors. The results were analyzed using a linear-quadratic model with a line of best fit of $y=(0.0583{\pm}0.0137)D+(0.0366{\pm}0.0081)D^2+(0.0093{\pm}0.0015)$ (y=number of MN/CB cells and D=irradiation dose in Gy). MN rates per 1,000 CB lymphocytes of cattle from the Goesan-gun, Cheongwon-gun, Boeun-gun and the control area were $6.50{\pm}2.72,\;9.00{\pm}4.50,\;10.89{\pm}4.23\;and\;9.60{\pm}4.70$, respectively. The MN frequencies of CB lymphocytes from cattle bred in 4 areas mean that the values are within the background variation in this experiment. The MN frequencies and hematological values were similar regardless of whether the cattle were bred in the HBRA or the control area.

Incidence of micronuclei in lymphocytes of pig in the high background radiation area (Cheongwon-gun and Boeun-gun) (국내 자연 방사선 고준위 지역(청원군, 보은군) 사육 돼지의 림프구 미소핵 발생 평가)

  • Lee, Hae-June;Kang, Chang-Mo;Kim, Se-Ra;Lee, Jin-Hee;Kim, Joong-Sun;Kim, Jong-Choon;Kim, Ill-Hwa;Kim, Tae-Hwan;Ryu, Si-Yun;Jo, Sung-Kee;Choi, Soo-Yong;Kim, Sung-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.4
    • /
    • pp.469-475
    • /
    • 2005
  • Cytogenetic and hematological analysis was performed in peripheral blood obtained from pigs bred in the high background radiation areas (HBRA) (Cheongwon-gun and Boeun-gun) and a control area. The frequencies of gamma-ray induced micronuclei (MN) in the cytokinesis-blocked (CB) lymphocytes at several doses were measured in three pigs. An estimated dose of radiation was calculated by a best fitting linear-quadratic model based on the radiation-induced MN formation from the swine lymphocytes exposed in vitro to radiation over the range from 0 mGy to 1,969 mGy. The measurements performed after irradiation showed dose-related increases in the MN frequency in each donors. The results were analyzed using a linear-quadratic model with a line of best fit of $y=0.0005404D^2+0.04237D+0.00833$ [y = number of MN/cytokinesis-blocked (CB) cells and D = irradiation dose in Gy]. MN rates per 1,000 CB lymphocytes of pig from the HBRA (Cheongwon-gun, Boeun-gun) and the control area were $6.70{\pm}2.36$, $9.00{\pm}3.50$ and $11.00{\pm}2.98$, respectively. The MN frequencies of CB lymphocytes from pigs bred in three areas means that the values are within the background variation in this experiment. The MN frequencies and hematological values were similar regardless of whether the pigs were bred in the HBRA or the control area.

A Study on the Evaluation of Radiation Safety in Opened-Ceiling-Facilities for Radiography Testing (천장 개방형 RT 사용시설의 방사선 안전성 평가 연구)

  • Sung-Hoe, Heo;Won-Seok, Park;Seung-Uk, Heo;Byung-In, Min
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.741-749
    • /
    • 2022
  • Radiography-Testing that verify the quality of welding structures without destruction are overwhelmingly used in industries, but many safety precautions are required as radiation is used. The workers for Radiography-Testing perform the inspection by moving the Iridium-192 radiation source embedded in the transport container of the gamma-ray irradiator within or outside the facility. The general facility is completely blocked about radiation from the outside with thick concrete, but if it is difficult for worker to handle object of inspection, facilities ceiling can be opened. A general facility may be constructed using a theoretical dose evaluation method because all exterior facilities are blocked, but if the ceiling is open, it is not appropriate to evaluate radiation safety with a simple theoretical calculation method due to the skyshine effect. Therefore, in this study, the radiation safety of the facility was evaluated in the actual field through an ion chamber survey-meter and an accumulated dose-meter called as OSLD, and the actual evaluation environment was modeled and evaluated using the Monte Carlo simulation code as FLUKA. According to the direction of the irradiation, the radiation dose at the facility boundary was difficult to meet the standards set by the regulatory authority, and radiation safety could be secured through additional methods. In addition, it was confirmed that the simulation results using the Iridium-192 source were valid evaluation with the actual measured results.

Dosimetric Study Using Patient-Specific Three-Dimensional-Printed Head Phantom with Polymer Gel in Radiation Therapy

  • Choi, Yona;Chun, Kook Jin;Kim, Eun San;Jang, Young Jae;Park, Ji-Ae;Kim, Kum Bae;Kim, Geun Hee;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.99-106
    • /
    • 2021
  • Purpose: In this study, we aimed to manufacture a patient-specific gel phantom combining three-dimensional (3D) printing and polymer gel and evaluate the radiation dose and dose profile using gel dosimetry. Methods: The patient-specific head phantom was manufactured based on the patient's computed tomography (CT) scan data to create an anatomically replicated phantom; this was then produced using a ColorJet 3D printer. A 3D polymer gel dosimeter called RTgel-100 is contained inside the 3D printing head phantom, and irradiation was performed using a 6 MV LINAC (Varian Clinac) X-ray beam, a linear accelerator for treatment. The irradiated phantom was scanned using magnetic resonance imaging (Siemens) with a magnetic field of 3 Tesla (3T) of the Korea Institute of Nuclear Medicine, and then compared the irradiated head phantom with the dose calculated by the patient's treatment planning system (TPS). Results: The comparison between the Hounsfield unit (HU) values of the CT image of the patient and those of the phantom revealed that they were almost similar. The electron density value of the patient's bone and brain was 996±167 HU and 58±15 HU, respectively, and that of the head phantom bone and brain material was 986±25 HU and 45±17 HU, respectively. The comparison of the data of TPS and 3D gel revealed that the difference in gamma index was 2%/2 mm and the passing rate was within 95%. Conclusions: 3D printing allows us to manufacture variable density phantoms for patient-specific dosimetric quality assurance (DQA), develop a customized body phantom of the patient in the future, and perform a patient-specific dosimetry with film, ion chamber, gel, and so on.

Physical Dosimetry in Radioactive Iodine Treatment in the Patients with Thyroid Cancer (갑상선암 환자에 대한 방사성옥소 치료시 물리적 선량 측정)

  • Kim, Myung-Seon;Jeong, Nae-In;Lee, Jai-Yong;Kim, Chong-Soon;Kim, Chong-Ho;Lee, Myung-Chul;Koh, Channg-Soon;Kim, Hee-Geun;Kang, Duck-Won;Song, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.124-132
    • /
    • 1994
  • Radioactive iodine has been widely used in patients with thyroid cancer combined with surgical treatment. However, due to individual variations in absorption and excretion and uptake by tumor tissue of radioactive iodine, there are differences in therapeutic effect and adverse effects even if the same doses are administrated. So this study compared the therapeutic effect and radiation hazard by measuring internal radiation dose. Of total 27 patients with well differentiated thyroid cancer who had been thyroidectomized, we administered radioactive iodine 100 mCi, 150 mCi, 200 mCi. According to BEL DOSIMETRY PROTO-COL, beta and gamma ray dose were estimated from a pelt of the logarithm of the percent of dose per liter of whole blood versus day, and percent dose retained versus day using somilogarithmic paper, respectively. 1) Physical dose to whole blood averaged $56.54{\pm}13.02$ rad in 100 mCi administered group, $76.83{\pm}19.97$ rad in 150 mCi administered group, $95.08{\pm}25.51$ rad in 200 mCi administered group and there has been a significant correlation among the groups. 2) Mean percent dose retained 48 hours later was 26.34%. 3) There was no significant correlation of physical dose between absence and presence of metastasis. 4) 17 of 19 patients who has been followed up with TSH and serum throglobulin, Thallium scan were successfully ablated by radioactive iodine. 5) Leukocyte, lymphocyte, neutrophil, platelet counts all deelined in 4.6 weeks and most of all were restored 3 months later. 6) There was no significant correlation between physical dosimetry and biologic dosimetry. Generally administered doses of radioactive iodine (100-200 mCi) to patients with thyroid cancer postoperatively had developed transient bone marrow suppression and minimal chromosomal aberration, but they were within safety dose to blood (200 rad). And there has been no significant differences in residual dose 48 hours later between Korean and western people.

  • PDF

Packing effects on the intracavitary radiation therapy of the utaine lervix cancer ($^{192}Ir$source를 이용할 자궁경부암 강내치료시 사용하는 packing의 효과에 대한 고찰)

  • Cho, Jung-Kun;Lee, Du-Hyun;Si, Chang-Kun;Choi, Yoon-Kyung;Kim, Tae-Yoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.73-77
    • /
    • 2004
  • Purpose of the radio-therapy is maximize the radiation dose to the tumor while minimizing the dose to the critical organ. Carcinoma of the uterine cervix treatment are external irradiation or an interstitial brachtheraphy make use of isotope. Brachytherapy is a method of radiotherapy in advantage to achieve better local control with minimum radiation toxicity in comparison with external irradiation because radiation dose is distributed according to the inverse square low of gamma-ray emitted from the implanted sources. Authors make use of the patients data which 192Ir gives medical treatment intrcavity. Intracavitary radiation of the uterine cervix cancer, critical organ take $20\%$ below than exposure dose of A point in the ICRU report. None the less of the advice, Radiation proctitis and radiation cystitis are frequent and problematic early complications in patients treated with radiation for the uterine cervix cancer. In brachytherapy of uterine cervical cancer using a high dose rate remote afterloading system, it is of prime importance to deliver a accurate dose in each fractionated treatment by minimizing the difference between the pre-treatment planned and post-treatment calculated doses. Use of packing to reduce late complications intracavitary radiation of the uterine cervix cancer. Bladder and rectum changes exposure dose rate by radiotherphy make use of packing.

  • PDF

Quality Characteristics of Milk Porridge (Tarakjuk) Sterilized with Radiation Technology (방사선 조사 기술을 이용하여 제조한 멸균 우유죽(타락죽)의 품질 특성)

  • Han, In-Jun;Park, Jae-Nam;Park, Jin-Gyu;Song, Beom-Seok;Lee, Ju-Woon;Kim, Jae-Hun;Ryu, Hong-Soo;Park, Jeong-Ro;Chun, Soon-Sil
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.6
    • /
    • pp.885-891
    • /
    • 2011
  • We conducted this study to determine the optimum dose of gamma irradiation needed for the sterilization of milk porridge for patients. Milk porridge, known as Tarakjuk, was irradiated with gamma ray at doses of 0, 1, 3, 5, 7, or 10 kGy. The microbial contamination, $D_{10}$ values of isolated microbe spores, color, and viscosity were measured during storage at $35^{\circ}C$. The initial count of total aerobic bacteria was 2.60 log CFU/g in the non-irradiated milk porridge, but coliforms, spore-forming bacteria, yeast, and molds were not detected. The total counts of aerobic and spore-forming bacteria in the non-irradiated and 1 kGy irradiated milk porridge increased with storage period. These microbes were not detected in the milk porridge irradiated with 10 kGy. The $D_{10}$ values of isolated spores from milk porridge were 2.71 kGy (in milk porridge) and 2.21 kGy (in saline solution). All CIE color increased with gamma irradiation, but the sensory value of color did not significantly change. The viscosity of the milk porridge decreased with gamma irradiation and storage period, and the decrease in viscosity with storage period became smaller as the radiation doses increased. Sensory evaluation scores of the milk porridge were above normal (4.0) when irradiated with less than 5 kGy. These results indicate that gamma irradiation could be beneficial for preparing food with higher nutrient density and lower viscosity, especially for gastric tube-fed patients.