• Title/Summary/Keyword: gamma ray dose

Search Result 484, Processing Time 0.027 seconds

Change of Lacquer Surface by Radiation (방사선에 의한 옻칠표면의 변화)

  • Yoon, Guk-joung
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.333-336
    • /
    • 2018
  • Natural lacquer was cured at room temperature at a relative humidity of 60% at $27^{\circ}C$ to obtain a lacquer film. Photolysis of lacquer was investigated by irradiating 1~75 kGy of gamma ray to this lacquer film. No significant changes were observed in the range of 1~10 kGy radiation. As the radiation doses were increased, the white spots were increased in the scanning electron microscope photographs. The increase of the white dots of the lacquer surface shows that the lacquer is degradation by radiation. As a result of IR spectral analysis of the lacquer surface with increasing irradiation dose, there was no significant change in $3,445cm^{-1}$ hydroxide group, $2,900cm^{-1}$ hydrocarbon group, and $993cm^{-1}$ triene group. However, the $1,745cm^{-1}$ carbonyl group was found to increase, and the $1,715cm^{-1}$ unsaturated hydrocarbon group and the $1,463cm^{-1}$ methylene group showed a tendency to decrease.

Transmission Dose Measurement of Gamma-ray Using Tungsten Shield (텅스텐 차폐체의 감마선 투과선량 측정)

  • Han, Sang-Hyun;Koo, Bon-Yeoul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.124-129
    • /
    • 2018
  • This study was conducted to investigate the penetration dose and shielding rates of tungsten shields used in apron material by changing the type of source used in the nuclear medicine department, thickness of shielding material and distance between the source and detector. For the experiment, the source, shield, and detector were arranged in a straight line and measured with an inspector at a height of 100 cm. The highest shielding effect of tungsten was measured for $^{201}Tl$, while $^{123}I$ showed a higher shielding effect than $^{99m}Tc$. For the sources used in the experiment, the penetration dose decreased with distance and the shielding rate was measured with thicker thickness. However, the shielding rate of $^{13}1I$ and $^{18}F$ sources was found to be lower than when there was no shielding at 0.25 mmPb shield. Therefore, even if the radiation shielding effect of tungsten is high, considering the characteristics according to the type of source and the thickness of the shielding material, it may be helpful to reduce the exposure.

Evaluation of Radiation Effect on Damage to Nuclear Fuel of Spent Fuel Transport CASK due to Sabotage Attack (사보타주 공격으로 인한 사용후핵연료 운반용기 격납 실패시 핵연료 손상에 따른 방사선 영향 평가)

  • Ki Ho Park;Jong Sung Kim;Gun il Cha;Chang Je Park
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.18 no.2
    • /
    • pp.43-49
    • /
    • 2022
  • The purpose of this study is to evaluate the radiation effect on damage when the external shield of the spent nuclear fuel transport cask is damaged due to impact as the cause of an unexpected accident. The neutron and gamma-ray intensities and spectra are calculated using the ORIGEN-Arp module in the SCALE 6.2.4 code package(1) and then using MCNP6.2(2) code calculate the dose rate. In order to evaluate the radiation dose according to the size of damage caused by external impact, various sized holes of 0.3~13.7% are assumed in the outer shield of the cask to evaluate the sensitivity to the dose. In the case of radiation source leakage, damage to the nuclear fuel assembly is assumed to be up to 6% based on overseas test cases. When only the outer shield is damaged, the maximum surface dose is calculated as 3.12E+03 mSv/hr. However, if the radiation source is leaked due to damage to the nuclear fuel assembly, it becomes 7.00E+05 mSv/hr which is about 200 times greater than the former case.

Evaluating internal exposure due to intake of 131I at a nuclear medicine centre of Dhaka using bioassay methods

  • Sharmin Jahan;Jannatul Ferdous;Md Mahidul Haque Prodhan;Ferdoushi Begum
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2050-2056
    • /
    • 2024
  • Handling of radioisotopes may cause external and internal contamination to occupational workers while using radiation for medical purposes. This research aims to monitor the internal hazard of occupational workers who handle 131I. Two methods are used: in vivo or direct method and in vitro or indirect method. The in vivo or direct method was performed by assessing thyroid intake with a thyroid uptake monitoring machine. The in vitro or indirect method was performed by assessing urine samples with the help of a gamma-ray spectroscopy practice using a High-Purity Germanium (HPGe) Detector. In this study, fifty-nine thyroid counts and fifty-nine urine samples were collected from seven occupational workers who were in charge of 131I at the National Institute of Nuclear Medicine and Allied Sciences (NINMAS), Dhaka. The result showed that the average annual effective dose of seven workforces from thyroid counts were 0.0208 mSv/y, 0.0180 mSv/y, 0.0135 mSv/y, 0.0169 m Sv/y, 0.0072 mSv/y, 0.0181 mSv/y, 0.0164 mSv/y and in urine samples 0.0832 mSv/y, 0.0770 mSv/y, 0.0732 mSv/y, 0.0693 mSv/y, 0.0715 mSv/y, 0.0662 mSv/y, 0.0708 mSv/y.The total annual effective dose (in vivo and in vitro method) was found among seven workers in average 0.1039 mSv/y, 0.0950 mSv/y, 0.0868 mSv/y, 0.0862 mSv/y, 0.0787 mSv/y, 0.0843 mSv/y, 0.0872 mSv/y. Following the rules of the International Commission on Radiological Protection (ICRP), the annual limit of effective dose for occupational exposure is 20 mSv per year and the finding values from this research work are lesser than this safety boundary.

Gamma Irradiation Effects on Conchospores of Porphyra Species 2. The Effects of High Gamma Irradiation on Germination and Growth of Conchospores of Two Varieties (김의 각포자에 대한 r-선의 조사효과 2. 두 품종의 각포자의 발아생장에 미치는 고선량 r-선의 조사효과)

  • KIM Joong-Rae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.1
    • /
    • pp.52-56
    • /
    • 1985
  • For the fundamental studies of radiation breeding in edible marine algae, the biological effects on conchospores of Porphyra species by gamma-irradiation were examined. Two varieties, Keun-cham-gim (Porphyra tenera Kjell. form tamatsuensis Miura) and Saga No.5, were chosen for this study, and their conchospores after r-irradiation($5.0{\sim}20.0$ KR) were cultured for 50 days. The results obtained were summarized as follows. 1. Gamma-irradiation in less than the dose of 20KR did not affect germination of conchospores, and almost all spores grew into two cells germ in 24 hours after irradiation, but withering germs were gradually increased in number according to higher exposure within 5 days old culture. 2. High irradiation caused the induction of giant cells, abnormal useless growth of hold-fast, lumpish thalli and callus-like lumpy tissues. 3. The liberation of neutral spores from young germs and carpospores from mature thalli were observed on the frond exposed at $10{\sim}20$ KR irradiation. All spores were normal in division and its size. 4. The best irradiation effect on growth of Keun-cham-gim was observed at 10 KR dose, whose growth-rates were $140\%$ in wet weight and $108\%$ in mean frond area, but only $48\%$ was recorded in wet weight at 20 KR exposure. Saga No.5 were in contrast with Keun-cham-gim, and their most growth-rate was $400\%$ in wet weight ($258\%$ in frond area) at 10 KR irradiation and the worst was $20\%$ at the dose of 20 KR. 5. The withering phenomenon to death by treatment of gamma-ray presented substantial difference between two varieties. Survival rate compared with control in Keun-cham-gim was $70.7\%$ at 20 KR, but that in Saga No.5 recorded $47.0\%$ at same dose. 6. Synthesizing the results of high and low r-irradiation, it was suggested tat high r-irradiation in more than 5.0 KR inhibited conspicuously the growth of germs derived from conchospores, and about half of them withered at 15.0 KR dose or more.

  • PDF

Dose- Response Curves of Mouse Jejunal Crypt Cells by Multifractionated Irradiation (다분할조사에 의한 마우스공장소낭선 세포의 선량반응곡선)

  • Hong, Seong-Eon;Ahn, Chi-Yul
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.89-97
    • /
    • 1986
  • Using as assay for jejunal crypt stem cell survival, dose-response curves for the reproductive capacity of crypt stem cells of mouse jejunum exposed to multifractionated gamma-ray irradiation (single, 2, 3, 4, 5, 8, 10, 12, and 16 fractions) were analyzed and single-dose survival curve of these cells was constructed. The following conclusion were drawn: 1) Survival curves for higher numbers of dose fractions were displaced to higher dose, and characterized by increasingly shallower slopes. 2) The single-dose survival curve had broad shoulder, Dq=460 cGy, remaining near-exponential over initial dose range 0 to 300 cGy, with initial slope 1Do=474 cGy. 3) At fractionated dose En the range of 180 to 450 cGy, the average recovered dose per fraction interval was approximately $50\%$ of the dose per fraction. 4) The value of $\alpha/\beta$ ratio by using of linear regression analysis for the reciprocal dose plots was 8.3 Gy which lied in the range of 6-14 Gy for early-reacting tissues. 5) The linear-quadratic model for dose-response formula offers valid approximations for at 1 doses to be used in radiotherapy, only two parameters to be determined, and considerable convenience in practical applications.

  • PDF

Induction of micronuclei in human, rabbit and dog lymphocytes irradiated in vitro with gamma radiation (사람, 토끼 및 개 유래 말초혈액 림프구의 미소핵을 이용한 방사선 피폭의 생물학적 선량측정)

  • Ryu, Si-yun;Kang, Bit-na;Kim, Ho-jun;Kim, Tae-hwan;Jeong, Kyu-sik;Kim, Se-ra;Lee, Hae-june;Kim, Sung-ho;An, Mi-Young
    • Korean Journal of Veterinary Research
    • /
    • v.42 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • The frequencies of gamma-ray-induced micronuclei (MN) in cytokinesis-blocked (CB) lymphocytes at several doses were measured in three donors of three species (human, rabbit, dog). Measurements performed after irradiation showed a dose-related increases in MN frequency in each of the donors studied. When analysed by linear-quadratic model the line of best fit was : human : $y=0.1184D+0.01867D^2+0.01$, rabbit : $y=0.0387D+0.00528D^2+0.01$ (y = number of MN/CB cells and D = irradiation dose in Gy). The relative sensitivity of rabbit lymphocytes compared with human lymphocytes was estimated by best fitting linear-quadratic model based on the radiation-induced MN data over the range from 0 Gy to 4 Gy. In the case of MN frequency with 0.2, the relative sensitivities of rabbit lymphocytes was 0.39. These data indicate that the induction of MN in rabbit CB cells following irradiation was much less sensitive to the MN induction effects of gamma-irradiation than those from human. The MN assay with dog lymphocytes was very difficult and time-consumed because the dog PHA-stimulated lymphocytes yielded cultures with very low level of CB cells formation in the condition of this experiment. Our in vitro radiobiological study confirmed that the cytogenetic response obtained in blood from rabbit can be utilized for application in environmental studies.

Physicochemical and Organoleptic Properties of Starch Isolated from Gamma-Irradiated Acorn (감마선 조사 도토리로부터 분리한 전분의 이화학적 및 관능적 특성)

  • Kwon, Joong-Ho;Kim, Soo-Jin;Lee, Jung-Eun;Lee, Soo-Jeong;Kim, Sung-Kon;Kim, Jeong-Sook;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.1007-1012
    • /
    • 2002
  • Physicochemical and organoleptic properties were investigated in starch extracted from acorn gamma-irradiated for insect control. Hunter's color L, a, and b values were unchanged upon irradiation at 0.25 to 10 kGy. Scanning electron microscopic observation revealed no changes with gamma irradiation at 1 kGy, that is effective for disinifestation, whereas 10 kGy resulted in some clefts on the starch surface. X-ray diffraction analysis showed patterns of both amorphous and crystalline regions were not different among the treatment groups. Water-binding property, swelling power, solubility, and gelatinization patterns of starch were influenced by irradiation dose, but 1 kGy dose was not detrimental to the physicochemical properties. Textural parameters of acorn gel were relatively stable, but significant reductions were found in hardness, adhesiveness, and chewiness in samples irradiated at 3 kGy or higher. Rrsults revealed that irradiation at 1 kGy or lower could be applied for insect control without causing apparent changes in physicochemical and organoleptic properties of acorn starch.

Assessment of natural radioactivity in soil and olive mill pomace utilizing nal (TI) gamma-ray spectrometry and low background alpha/beta counting system

  • Amani Kraishan;Mohammad Abu Shayeb;Hafedh Belmabrouk;Ahmad Ali Husein Qwasmeh;Muzahir Ali Baloch
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1925-1931
    • /
    • 2024
  • The study conducted in the northwest region of Jordan aimed to assess the levels of natural radioactivity in soil and olive mill pomace (OMP) samples. The researchers used Nal (TI) gamma-ray spectrometry to measure the activity concentrations of 226Ra, 232Th, 40K, and 137Cs in the samples. The average activity concentrations of 226Ra, 232Th, 40K, and 137Cs in the soil samples were found to be 18.624 ± 5.82, 12.276 ± 5.728, 518.33 ± 212.57, and 0.140 ± 0.09 (Bq, kg-1), respectively. In the OMP samples, the average activity concentrations of 226Ra, 232Th, and 40K were 7.272 ± 4.386, 3.454 ± 1.503, and 169.997 ± 81.873 (Bq kg-1), respectively, and no 137Cs was detected. The study also investigated fundamental parameters associated with radon, specifically the radon emanation coefficient (RnEC) and radon mass exhalation rate (Ex). The RnEC values ranged from 0.621 to 0.78 (Bq kg-1), with an average value of 0.71 ± 0.06 (Bq kg-1). The estimated Ex from the soil samples ranged from 65.83 to 124.86 (mBq kg-1h-1), with an average value of 99.74 ± 21.73 (mBq kg-1h-1). Regarding radiological hazards, the study examined various parameters, including radium equivalent activity, external and internal hazard indices, gamma and alpha indices, absorbed gamma dose rate, and excess lifetime cancer risk. All of these assessed values were found to be below the worldwide recommended limits for radiological safety. Additionally, the study analyzed the concentrations of gross alpha and gross beta radioactivities in soil and OMP samples. The soil samples had an average gross alpha activity of 4.642 ± 1.04 (Bq kg-1) and an average gross beta activity of 48.13 ± 14.50 (Bq kg-1). The OMP samples showed an average gross alpha activity of 0.32 ± 0.27 (Bq kg-1) and an average gross beta activity of 59.19 ± 12.94 (Bq kg-1). Overall, the obtained results are crucial for evaluating the radiological risks associated with natural radioactivity in the northwest region of Jordan. The findings establish baseline data for comparison and reference for radioactivity levels in the environment.

Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife (로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가)

  • Jeong, Young-Joon;Jung, Jae-Hong;Lim, Kwang-Chae;Cho, Eun-Ju
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: The purpose is to evaluate the accuracy of correcting the targeting error through the Target Location System (TLS) for the location change error of the reference point which arises from the movement or motion of patient during the treatment using the CyberKnife. Materials and Methods: In this test, Gafchromic MD-55 film was inserted into the head and neck phantom to analyze the accuracy of the targeting, and then the 6 MV X-ray of CyberKnife (CyberKnife Robotic Radiosurgery System G4, Accuray, US) was irradiated. End to End (E2E) program was used to analyze the accuracy of targeting, which is provided by Accuray Corporation. To compute the error of the targeting, the test was carried out with the films that were irradiated 12 times by maintaining the distance within the rage of $0{\pm}0.2\;mm$ toward x, y, z from the reference point and maintaining the angle within the rage of $0{\pm}0.2^{\circ}$ toward roll, pitch, yaw, and then with the films which were irradiated 6 times by applying intentional movement. And the correlation in the average value of the reference film and the test film were analyzed through independent samples t-test. In addition, the consistency of dose distribution through gamma-index method (dose difference: 3%) was quantified, compared, and analyzed by varying the distance to agreement (DTA) to 1 mm, 1.5 mm, 2 mm, respectively. Results: E2E test result indicated that the average error of the reference film was 0.405 mm and the standard deviation was 0.069 mm. The average error of the test film was 0.413 mm with the standard deviation of 0.121 mm. The result of independent sampling t-test for both averages showed that the significant probability was P=0.836 (confidence level: 95%). Besides, by comparing the consistency of dose distribution of DTA through 1 mm, 1.5 mm, 2 mm, it was found that the average dose distribution of axial film was 95.04%, 97.56%, 98.13%, respectively in 3,314 locations of the reference film, consistent with the average dose distribution of sagittal film that was 95.47%, 97.68%, 98.47%, respectively. By comparing with the test film, it was found that the average dose distribution of axial film was 96.38%, 97.57%, 98.04%, respectively, at 3,323 locations, consistent with the average dose distribution of sagittal film which was 95.50%, 97.87%, 98.36%, respectively. Conclusion: Robotic CyberKnife traces and complements in real time the error in the location change of the reference point caused by the motion or movement of patient during the treatment and provides the accuracy with the consistency of over 95% dose distribution and the targeting error below 1 mm.

  • PDF