• 제목/요약/키워드: galvanized(GI)

검색결과 16건 처리시간 0.028초

Investigation of Galling In Forming Galvanized Steel Sheet

  • Altan, Taylan;Kardes, Nimet;Kim, Hyunok
    • Corrosion Science and Technology
    • /
    • 제10권1호
    • /
    • pp.1-5
    • /
    • 2011
  • The major purpose of the present study is to evaluate the performance of various galvanized (GI) or galvannealed (GA) mild steels and AHSS in stamping applications. Finite Element Analysis (FEA) of selected stamping operations was conducted to estimate the critical pressure boundary conditions that exist in practice. Using this information, laboratory tribotests, e.g. Twist Compression (TCT), Deep Drawing (DDT) and Strip Drawing (SDT) Tests, were developed to evaluate the performance of selected lubricants and die materials/coatings in forming galvanized steels of interest. The sheet materials investigated included mild steels and AHSS (e.g. DP600 GI/GA, DP780 GI/GA, TRIP780 GA and DP980 GI/GA). Experimental results showed that galvanized material resulted in more galling, while galvannealed material showed more powdering and flaking. The surface roughness and chemical composition of galvanized sheet materials affected the severity of galling under the same testing conditions, i.e. lubricants and die materials/coatings. The results of this study helped to determine the critical interface pressure that initiates lubricant failure and galling in stamping selected galvanized sheet materials. Thus, to prevent or postpone the critical interface conditions, the results of this study can be used to select the optimum combination of galvanized sheet, die material, die coating and lubricant for forming structural automotive components.

아연도금강판의 방식을 위한 새로운 방청안료인 이온 교환된 제올라이트의 방청 성능 (Anti-Corrosion Performance of the Novel Pigment, Ion-Exchanged Zeolite for the Protection of Galvanized Steel)

  • 김정택;정호수;유상수;이근대;박종명
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.745-751
    • /
    • 2011
  • 내부식성이 강화된 새로운 방청안료를 개발하기 위한 연구의 일환으로, 본 연구에서는 높은 내부식성을 제공하는 아연 및 세륨 이온 교환된 제올라이트를 도입하였다. 그리고 이온교환 제올라이트를 이용하여 프라이머 도료 제조 및 도장을 수행한 후, 그것의 방식성능을 측정하였다. 도장을 위한 금속 기재는 아연도금(galvanized, GI) 강판이었고, 도장된 강판의 방식성능은 electrochemical impedance spectroscopy(EIS)와 scanning vibrating electrode technique(SVET)으로 측정되었다. EIS 및 절단면의 내부식성을 확인하기 위한 SVET 측정으로부터 세륨이온 교환된 제올라이트가 가장 높은 효율을 제시하였고, 아연 및 세륨 이온 교환된 제올라이트의 경우 GI 강판에 대하여 cathodic 부식 방지제로 기여함을 확인할 수 있었다.

36개월간 국내 옥외폭로시험에 따른 아연도강의 표면외관 변화 (Surface Appearance of Galvanized Steel with Outdoor Exposure Testing in Korea for 36 Months)

  • 김기태;김영식
    • Corrosion Science and Technology
    • /
    • 제17권6호
    • /
    • pp.301-309
    • /
    • 2018
  • If galvanized steel is exposed to an outdoor environment, atmospheric corrosion will occur with time and red rust will form when the sacrificial protection capacity of zinc reaches its limit. With corrosion, the surface appearance of steel changes, and the properties of the exterior materials degrade. In this study, two kinds of galvanized steel, (GA and GI specimens) were subjected to an outdoor exposure test for 36 months in six regions of Korea. Chrominance (color, chroma, and brightness) and glossiness surface analyses were performed. The color change was not significant, regardless of the exposed area or the specimens tested. With increasing exposure times, the GA specimen became blackened by the formation of zinc oxide, and red coloration was increased by the formation of red rust. As the exposure time of GI specimen increased, the surface proceeded to blacken, but no red rust was formed and the color did not change significantly. Regardless of the outdoor exposure area or the specimen, longer exposure times led to lower glossiness, and this behavior appears to be influenced by the formation of zinc oxide.

36개월간 국내 옥외폭로시험에 따른 아연도강의 부식거동 (Corrosion Behavior of Galvanized Steels with Outdoor Exposure Test in Korea for 36 Months)

  • 김기태;김영식
    • Corrosion Science and Technology
    • /
    • 제17권5호
    • /
    • pp.231-241
    • /
    • 2018
  • Atmospheric corrosion is generally an electrochemical degradation process of metal. It can be caused by various corrosion factors of atmospheric component, weather, and air pollutants. Moisture, particles of sea salts, and sulfur dioxide are major factors in atmospheric corrosion. Galvanizing coating is one of the most efficient ways to protect iron from corrosion by zinc plating on the surface of the iron. Galvanized steels are being widely used in automobiles, building structures, roofing, and other industrial structures due to their high corrosion resistance compared to bare iron. Atmospheric corrosion of galvanized steel has shown complex corrosion behavior depending on coating process, coating thickness, atmospheric environment, and air pollutants. In addition, different types and kinds of corrosion products can be produced depending on the environment. Lifespan of galvanized steels is also affected by the environment. Therefore, the objective of this study was to determine the corrosion behavior of galvanized steel under atmospheric corrosion at six locations in Korea. When the exposure time was increased, content of zinc from GA surface decreased while contents of iron and oxygen tended to increase. On the other hand, content of iron was constant even after 36 months of exposure of GI.

The Characteristics of Galvanized Steel Coated with Organic-Inorganic Resin

  • Kim, Jong-Gi;Park, Sang-Jin;Goo, Bong-Joo;Lee, Bo-Ryong;Yoo, Jeong-Mo
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 춘계학술발표회 논문집
    • /
    • pp.281-281
    • /
    • 2012
  • We could confirm the results such as excellent anti-corrosion compared to chromate, conductivity, chemical resistance and detergent resistance as the result of analysis of various characteristics of the galvanized steel coated with organic-inorganic developed in this research.

  • PDF

마찰교반점용접을 이용한 이종재료의 접합 (Friction spot joining of dissimilar materials)

  • 천창근;김특기;;김흥주;장웅성
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2007년 추계학술발표대회 개요집
    • /
    • pp.155-157
    • /
    • 2007
  • The Friction spot dissimilar welding of galvanized steel/Al6061-T6 was performed to investigate the mechanical characteristics of the joints. The presence of thin film of aluminum oxide on the surface and melting of zinc in the coating, made substandard joint characteristics for dissimilar Friction spot joining(FSJ) performed with out removing the coating. Where as, for dissimilar FSJ of galvanized steel/Al6061-T6 after removing the coating, superior agitation and welding quality has been obtained for a configuration of galvanized steel as the upper plate and Al6061-T6 as lower plate. The results from tensile tests and microscopic examination for various combinations of the welding parameters have been presented.

  • PDF

슈퍼픽셀 DBSCAN 군집 알고리즘을 이용한 용융아연도금 강판의 부식이미지 분석 (Corrosion image analysis on galvanized steel by using superpixel DBSCAN clustering algorithm)

  • 김범수;김연원;이경황;양정현
    • 한국표면공학회지
    • /
    • 제55권3호
    • /
    • pp.164-172
    • /
    • 2022
  • Hot-dip galvanized steel(GI) is widely used throughout the industry as a corrosion resistance material. Corrosion of steel is a common phenomenon that results in the gradual degradation under various environmental conditions. Corrosion monitoring is to track the degradation progress for a long time. Corrosion on steel plate appears as discoloration and any irregularities on the surface. This study developed a quantitative evaluation method of the rust formed on GI steel plate using a superpixel-based DBSCAN clustering method and k-means clustering from the corroded area in a given image. The superpixel-based DBSCAN clustering method decrease computational costs, reaching automatic segmentation. The image color of the rusty surface was analyzed quantitatively based on HSV(Hue, Saturation, Value) color space. In addition, two segmentation methods are compared for the particular spatial region using their histograms.

용융도금한 콘크리트 방식철근재의 내식특성 (Anti-corrosive characteristics of hot dip galvanized steel rebar for concrete)

  • 양정현;배일용;백상민;김기준;이명훈;이상민
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2007년도 추계학술대회 논문집
    • /
    • pp.24-24
    • /
    • 2007
  • 콘크리트 강화용 철근재료의 제작을 위하여 여러 가지 조성의 용융도금을 실시하였다. 여기서는 여러 가지의 중성 및 알칼리 환경에서 이들 용융도금 철근재의 내식특성 변화에 대해 조사함으로써 콘크리트용 용융도금철근재료에 대한 유효성을 검코하고 적용설계에 관한 기초적인 지침을 제시하고자 하였다.

  • PDF

The Characteristics of Cr-Free Coating Hot Dip Galvanized Sheet Steel

  • Kim, Jong-Gi;Moon, Man-Been;Yun, Jeong-Mo
    • Corrosion Science and Technology
    • /
    • 제10권1호
    • /
    • pp.24-29
    • /
    • 2011
  • The greatest purpose of chromate treatment is to improve anti-corrosion by stabilizing a metal surface. Because metal surface forms a compound by absorbing oxygen or water in the air by being generally unstable, it is necessary to improve anti-corrosion of the metal by forming the metal surface with a stable film. When considering the economical efficiency and requirements together because the film of the metal surface treated with chromate has good anti-corrosion and the stability also in the air by being compact and strong, Chromate treatment has been used most up to the electronics industry from the auto industry. However, these days, because hexavalent chromium is both a toxic agent to be able to cause cancers and deadly poisonous environmental pollutant, the strong legal controls on its use is being imposed all over the world. Because of this reason, a new anti-corrosion method is being required. Also, by users' various demands, the passivations that have recently been developed require various characteristics such as conductivity, chemical resistance, alkali cleaning resistance as well as anti-corrosion. We could confirm the results such as excellent anti-corrosion compared to chromate, conductivity, chemical resistance and detergent resistance as the result of analysis of various characteristics of the galvannealed sheet steels coated with Cr-Free solution developed in this research.

엑스트라도조교 사재 정착구 시스템에 대한 실험적 연구 (Experimental Study of Extradosed Bridge Anchor System)

  • 김기동;박원태
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.146-154
    • /
    • 2010
  • In this study the experimental results of fatigue specimen for the Strand Stay Cable Assembly of Extadosed bridges is investigated. The fatigue test and tensile experiment is conducted to 6 kinds of specimens. Test specimen OVM250-31 Strand Cable System manufactured by china OVM B-Machinery Co., Ltd, and OVM250-42 Parallel Strand Stay Cable Assembly manufactured by china OVM B-Machinery Co., Ltd, are passed for fatigue test and rupture tensile test. But Test specimen OVM250-42 Parallel Strand Stay Cable Assembly manufactured by korean A-Machinery Co., Ltd, is not passed for fatigue test conducted according to the "Recommendation for Stay Cable Design. The test result are compared to the fatigue criteria of PHI 2001 for cyclic load, and it is concluded that the current korean design code will be needed for representing the fatigue load in Hot Dip Galvanized Strand Stay Cable. It is verified that the new korean specification and quality criteria of Strand Stay Cable and exact experimental applied process will be needed.