• Title/Summary/Keyword: fuzzy PI and PI controllers

Search Result 62, Processing Time 0.026 seconds

Hybrid Fuzzy PI-Control Scheme for Quasi Multi-Pulse Interline Power Flow Controllers Including the P-Q Decoupling Feature

  • Vural, Ahmet Mete;Bayindir, Kamil Cagatay
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.787-799
    • /
    • 2012
  • Real and reactive power flows on a transmission line interact inherently. This situation degrades power flow controller performance when independent real and reactive power flow regulation is required. In this study, a quasi multi-pulse interline power flow controller (IPFC), consisting of eight six-pulse voltage source converters (VSC) switched at the fundamental frequency is proposed to control real and reactive power flows dynamically on a transmission line in response to a sequence of set-point changes formed by unit-step reference values. It is shown that the proposed hybrid fuzzy-PI commanded IPFC shows better decoupling performance than the parameter optimized PI controllers with analytically calculated feed-forward gains for decoupling. Comparative simulation studies are carried out on a 4-machine 4-bus test power system through a number of case studies. While only the fuzzy inference of the proposed control scheme has been modeled in MATLAB, the power system, converter power circuit, control and calculation blocks have been simulated in PSCAD/EMTDC by interfacing these two packages on-line.

High Performance Control of Induction Motor Drive using Multi Adaptive Fuzzy Controller (다중 적응 퍼지제어기를 이용한 유도전동기 드라이브의 고성능 제어)

  • Ko, Jae-Sub;Choi, Jung-Sik;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.59-68
    • /
    • 2009
  • The field oriented control of induction motors is widely used in high performance applications. However, detuning caused by parameter disturbance still limits the performance of these drives. In order to accomplish variable speed operation, conventional PI-like controllers are commonly used. These controllers provide limited good performance over a wide range of operation, even under ideal field oriented conditions. This paper is proposed high performance control of induction motor drive using multi adaptive fuzzy controller. This controller has been performed for speed control with fuzzy adaptation mechanism (FAM)-PI, current control with model reference adaptive fuzzy control(MFC) and estimation of speed using ANN. The proposed control algorithm is applied to induction motor drive system using FAM-PI, MFC and ANN controller. The performance of proposed controller is evaluated by analysis for various operating conditions using parameters of induction motor drive. Also, this paper is proposed the analysis results to verify the effectiveness of this controller.

Current Control of Switched Reluctance Motor Using Self-tuning Fuzzy Controller (자기동조 퍼지 제어기를 이용한 스위치드 릴럭턴스 모터의 전류제어)

  • Lee, Young-Soo;Kim, Jaehyuck;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.473-479
    • /
    • 2016
  • This paper describes an accurate and stable current control method of switched reluctance motors(SRMs), which have recently attracted considerable wide attention owing to their favorable features, such as high performance, high durability, structural simplicity, low cost, etc. In most cases, the PI controllers(PICC) have been used mostly for the current control of electric motors because their algorithm and selection of controller gain are relatively simpler compared to other controllers. On the other hand, the PI controller requires an adjustment of the controller gains for each operating point when nonlinear system parameters change rapidly. This paper presents a stable current control method of an SRM using self-tuning fuzzy current controller(STFCC) under nonlinear parameter variation. The performance of the considered method is validated via a dynamic simulation of the current controlled SRM drive using Matlab/Simulink program.

추정된 절삭력 신호를 이용한 선삭력 제어

  • 허건수;김재옥
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.5
    • /
    • pp.173-179
    • /
    • 2000
  • While a cutting tool is machining a workpiece at various cutting depth, the feedrate is usually selected based on the maximum depth of cut. Even if this selection can avoid power saturation or tool breakage, it is very conservative compared to the capacity of the machine tools and can reduce the productivity significantly. Many adaptive control techniques that can adjust the feedrate to maintain the constant cutting force have been reported. However, these controllers are not very widely used in manufacturing industry because of the limitations in measuring the cutting force signals. In this paper, turning force control systems based on the estimated cutting force signals are proposed. A synthesized cutting force monitor is introduced to estimate the cutting force as accurately as a dynamometer does. Three control strategies of PI, adaptive and fuzzy logic controllers are applied to investigate the feasibility of utilizing the estimated cutting force fur turning force control. The experimental results demonstrate that the proposed systems can be easily realized in CNC lathe with requiring little additional hardware.

  • PDF

Speed Control of Induction Machines Using Fuzzy Algorithm with Hierarchical Structure

  • Lee, Ho-Seok;Cho, Soon-Bong;Hyun, Dong-Seok
    • Journal of Electrical Engineering and information Science
    • /
    • v.1 no.2
    • /
    • pp.101-108
    • /
    • 1996
  • A new speed controller based on the fuzzy algorithm with hierarchical structure is presented. The input variables of the controller are speed error and its derivative(change of error), where the output variable is the change of torque current command. Several comparisons were performed with conventional PI (proportional plus integral) controller and proposed controller. These controllers are applied to the laboratory model drive system with 2.2kW induction motor. Some simulation and experimental results show that the speed controller using fuzzy algorithm is more robust than the conventional PI controller.

  • PDF

Design of Optimal Fuzzy Logic based PI Controller using Multiple Tabu Search Algorithm for Load Frequency Control

  • Pothiya Saravuth;Ngamroo Issarachai;Runggeratigul Suwan;Tantaswadi Prinya
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.2
    • /
    • pp.155-164
    • /
    • 2006
  • This paper focuses on a new optimization technique of a fuzzy logic based proportional integral (FLPI) load frequency controller by the multiple tabu search (MTS) algorithm. Conventionally, the membership functions and control rules of fuzzy logic control are obtained by trial and error method or experiences of designers. To overcome this problem, the MTS algorithm is proposed to simultaneously tune proportional integral gains, the membership functions and control rules of a FLPI load frequency controller in order to minimize the frequency deviations of the interconnected power system against load disturbances. The MTS algorithm introduces additional techniques for improvement of the search process such as initialization, adaptive search, multiple searches, crossover and restart process. Simulation results explicitly show that the performance of the proposed FLPI controller is superior to conventional PI and FLPI controllers in terms of overshoot and settling time. Furthermore, the robustness of the proposed FLPI controller under variation of system parameters and load change are higher than that of conventional PI and FLPI controllers.

A Novel Approach to Prevent Pressure Ulcer for a Medical Bed using Body Pressure Sensors

  • Young Dae Lee;Arum Park
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.146-157
    • /
    • 2024
  • Despite numerous air mattresses marketed to prevent Pressure Ulcers (PU), none have fully succeeded due to residual pressure surpassing critical levels. We introduces an innovative medical bed system aiming at complete PU prevention. This system employs a unique 4-bar link mechanism, moving keys up and down to manage body pressure. Each of the 17 keys integrates a sensor controller, reading pressure from 10 sensors. By regulating motor input, we maintain body pressure below critical levels. Keys are equipped with a servo drive and sensor controller, linked to the main controller via two CAN series. Using fuzzy or PI/IP controllers, we adjust keys to minimize total error, dispersing body pressure and ensuring comfort. In case of controller failure, keys alternate swiftly, preventing ulcer development. Through experimental tests under varied conditions, the fuzzy controller with tailored membership functions demonstrated swift performance. PI control showed rapid convergence, while IP control exhibited slower convergence and oscillations near zero error. Our specialized medical robot bed, incorporating 4-bar links and pressure sensors, underwent testing with three controllers-fuzzy, PI, and IP-showcasing their effectiveness in keeping body pressure below critical ulcer levels. Experimental results validate the proposed approach's efficacy, indicating potential for complete PU prevention.

Position-type fuzzy controller using the accumulated error scaling factor (누적오차 조정계수를 이용한 위치형 퍼지제어기)

  • 김동하;전해진;최봉열
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.177-177
    • /
    • 2000
  • In this paper, we propose a two-input two-output fuzzy controller to improve the performance of transient response and to eliminate the steady state error. The outputs of this controller are the control input calculated by position-type fuzzy controller and the accumulated error scaling factor. Here, the accumulated error scaling factor is adjusted on-line by fuzzy rules according to the current trend of the controlled process. To show the usefulness of the proposed controller, it is applied to several systems that are difficult to get satisfactory response by conventional PD controllers or PI controllers.

  • PDF

Expert Knowledge-Based Fuzzy Auto-Tuning of PI Controllers for a Drum-Type Boiler of Fossil Power plant (전문가 지식을 이용한 화력 발전소 드럼형 보일러 PI 제어기의 퍼지 자동 동조에 관한 연구)

  • ;;;Zeungnam Bien
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.11
    • /
    • pp.941-954
    • /
    • 1991
  • The characteristics of a power plant changes as it operates for a long time and/or for different operating point. As a result, operators must retune gains of the controllers for better performance. In fact, skilled operators can retune the gains in reference to recorded data obtained by a test called dynamic test. The dynamic test, however, requires much time, and can be heavy burden for operators. In this paper, an expert knowledge-based auto-tuner is designed for drum-type boiler controllers of a fossil power plant using fuzzy logic. The performance of the proposed auto-tuner is shown via computer simulation and the simulation results show that the proposed auto-tuner is satisfactory for the desired performance.

  • PDF

A Study on an Analytical Approach to the Derivation of Fuzzy PI Scaling Factor (퍼지 PI scaling factor의 분석적인 유도방법에 관한 연구)

  • 전기영
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.460-463
    • /
    • 2000
  • Fuzzy logic control(FLC) has been studied extensively and has been applied in various applications. The most popular control strategy takes the Fuzzy Proportional-Integral(FPI) form while systematic methods have been developed to derive the fuzzy rules and membership functions the choice of the scaling factors remains an open problem, In this paper an analytical FPI scaling factor determining method is derived based on the functional equivalence of the PI and FPI controllers. Simulation have been carried out with a brushless DC motor drive system as test-bed the obtained results drive system as test-bed the obtained results have verified that the derived method is applicable to both the initial choice and further tuning of the FPI scaling factors.

  • PDF