• Title/Summary/Keyword: fusion material

Search Result 552, Processing Time 0.029 seconds

Study on the Mechanical Properties and Thermal Conductive Properties of Cu/STS/Cu Clad Metal for LED/semiconductor Package Device Lead Frame (LED 및 반도체 소자 리드프레임 패키징용 Cu/STS/Cu 클래드메탈의 기계적/열전도/전기적 특성연구)

  • Lee, Chang-Hun;Kim, Ki-Chul;Kim, Young-Sung
    • Journal of Welding and Joining
    • /
    • v.30 no.3
    • /
    • pp.32-37
    • /
    • 2012
  • Lead frame which has a high thermal conductivity and high mechanical strength is one of core technology for ultra-thin electronics such as LED lead frames, memory devices of semiconductors, smart phone, PDA, tablet PC, notebook PC etc. In this paper, we fabricated a Cu/STS/Cu 3-layered clad metal for lead frame packaging materials and characterized the mechanical properties and thermal conductive properties of the clad metal lead frame material. The clad metal lead frame material has a comparable thermal conductivity to typical copper alloy lead frame materials and has a reinforced mechanical tensile strength by 1.6 times to typical pure copper lead frame materials. The thermal conductivity and mechanical tensile strength of the Cu/STS/Cu clad metal are 284.35 W/m K and $52.78kg/mm^2$, respectively.

Axial compression behavior of double-skinned composite tubular columns under pure compression on concrete cores

  • Lee, Jeonghwa;Byun, Namju;Kang, Young Jong;Won, Deok Hee;Kim, Seungjun
    • Steel and Composite Structures
    • /
    • v.43 no.4
    • /
    • pp.431-445
    • /
    • 2022
  • A double-skinned composite tubular (DSCT) column, which is an internally confined concrete-filled tubular column with a hollow section, has been developed for efficient use of materials that reduce self-weight and enhance seismic performance. It exhibits excellent material behavior with ductility owing to the confinement induced by outer and inner steel tubes. This study conducted axial compression tests considering the effects of steel tube thickness and hollow diameter ratios of DSCT columns on the material behavior of confined concrete under pure axial compression on concrete cores. From the axial compression tests, various combinations of outer and inner tube thicknesses and two different hollow section ratios were considered. Additionally, confined concrete material behavior, axial strength, failure modes, and ductility of DSCT columns were evaluated. Based on this study, it was concluded that the tests show a good correlation with peak strength and shapes of nonlinear stress-strain curves presented in literature; however, the thinner outer and inner steel tubes may reduce the ductility of DSCT columns when using thinner outer and inner tubes and higher confined stress levels. Finally, the minimum thickness requirements of the steel tubes for DSCT columns were discussed in terms of strength and ductility of test specimens.

Radical Mist Generator Using a Water Plasma Jet and Its Sterilization Effect

  • Huh, Jin Young;Ma, Suk Hwal;Kim, Kangil;Choi, Eun Ha;Hong, Yong Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.175.1-175.1
    • /
    • 2016
  • In recent, tract infections such as atopic dermatitis, allergic rhinitis and a respiratory disease are increasing, giving rise to the atmospheric pollution, inflow of micro-size dust and side effect of humidifier disinfectant. In this context, the environment-friendly technology is required to eliminate airborne pathogens. We propose solution of the previous problems, making use of Radical Mist Generator (RMG). Existing technologies of air purification using a gas discharge produce harmful substances such as ozone, NOx, etc. However, the RMG uses a pure water as a plasma forming material. The RMG sprays the water mist, which contains reactive radicals to sterilize microorganisms. RMG is comprised of a power supply, plasma electrodes and a nozzle. In order to analyze the electrical characteristic and concentrations of reactive radicals, we employ an oscilloscope and a titration method. To test the sterilization effect of RMG, we used E.coli. We confirmed that E.coli was killed over 90%. Eventually, we expect that RMG can be promising tool for a purified system.

  • PDF

Temperature-dependent Structural and Magnetic Properties of Diamagnetic $HgI_2$

  • Park, C.I.;Jin, Zhenlan;Hwang, I.H.;Yeo, S.M.;Han, S.W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.291.1-291.1
    • /
    • 2013
  • We examined the temperature-dependent structural and magnetic properties of HgI2 in the temperature range of 300~400 K. HgI2 is a diamagnetic material and can be used for X-ray or γ-ray detectors. DCmagnetization measurements on HgI2 showed that there is a small but distinguishable change in its diamagnetic properties near 375 K. The magnetic property change is not expected because Hg and I are known as nonmagnetic elements. X-ray diffraction (XRD) measurements revealed a structural transition in the temperature of 350~400 K. Temperature-dependent x-ray absorption fine structure (XAFS) demonstrated that the chemical valence states of both Hg and I did not changed in the temperature range of 300~400 K. However, XAFS revealed that the bond-length disorder was slightly increased in the temperature range, particularly, near Hg atoms. The structural changes of HgI2 are likely related to its diamagnetic property change. We will discuss the relation between the diamagnetic properties and local structural properties of HgI2 in detail.

  • PDF

Fabrication and Characterization of Superhydrophobic Glass Surfaces Using Silicon Micro-mold and Thermal-reflow Process (실리콘 마이크로 몰드와 유리의 열-재흐름 현상을 이용한 초소수성 유리 표면 제작 및 젖음 특성 평가)

  • Kim, Seung-Jun;Kong, Jeong-Ho;Lee, Dongyun;Kim, Jong-Man
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.8
    • /
    • pp.591-597
    • /
    • 2012
  • This paper presents regularly micro-textured glass surfaces ensuring the superhydrophobic properties in the Cassie-Baxter regime. The proposed surfaces were fabricated simply and efficiently by filling the glass material into a silicon micro-mold with periodic micro-cavities based on a thermal-reflow process, resulting in a successful demonstration of the textured glass surface with periodically-arrayed micro-pillar structures. The static and dynamic wetting properties of the micro-textured glass surfaces were characterized by measuring the static contact angle (SCA) and contact angle hysteresis (CAH), respectively. In addition, the surface wettability was estimated theoretically based on Wenzel and Cassie-Baxter wetting theories, and compared with the experimental ones. Through the experimental and theoretical observations, it was clearly confirmed that the proposed micro-textured glass surfaces showed the slippery superhydrophobic behaviors in the Cassie-Baxter wetting mode.

Radiographic Analysis of Instrumented Posterolateral Fusion Mass Using Mixture of Local Autologous Bone and b-TCP (PolyBone$^{(R)}$) in a Lumbar Spinal Fusion Surgery

  • Park, Jin-Hoon;Choi, Chung-Gon;Jeon, Sang-Ryong;Rhim, Seung-Chul;Kim, Chang-Jin;Roh, Sung-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.5
    • /
    • pp.267-272
    • /
    • 2011
  • Objective : Although iliac crest autograft is the gold standard for lumbar fusion, the morbidity of donor site leads us to find an alternatives to replace autologous bone graft. Ceramic-based synthetic bone grafts such as hydroxyapatite (HA) and b-tricalcium phosphate (b-TCP) provide scaffolds similar to those of autologous bone, are plentiful and inexpensive, and are not associated with donor morbidity. The present report describes the use of Polybone$^{(R)}$ (Kyungwon Medical, Korea), a beta-tricalcium phosphate, for lumbar posterolateral fusion and assesses clinical and radiological efficacy as a graft material. Methods : This study retrospectively analyzed data from 32 patients (11 men, 21 women) who underwent posterolateral fusion (PLF) using PolyBone$^{(R)}$ from January to August, 2008. Back and leg pain were assessed using a Numeric Rating Scale (NRS), and clinical outcome was assessed using the Oswestry Disability Index (ODI). Serial radiological X-ray follow up were done at 1, 3, 6 12 month. A computed tomography (CT) scan was done in 12 month. Radiological fusion was assessed using simple anterior-posterior (AP) X-rays and computed tomography (CT). The changes of radiodensity of fusion mass showed on the X-ray image were analyzed into 4 stages to assess PLF status. Results : The mean NRS scores for leg pain and back pain decreased over 12 months postoperatively, from 8.0 to 1.0 and from 6.7 to 1.7, respectively. The mean ODI score also decreased from 60.5 to 17.7. X-rays and CT showed that 25 cases had stage IV fusion bridges at 12 months postoperatively (83.3% success). The radiodensity of fusion mass on X-ray AP image significantly changed at 1 and 6 months. Conclusion: The present results indicate that the use of a mixture of local autologous bone and PolyBone$^{(R)}$ results in fusion rates comparable to those using autologous bone and has the advantage of reduced morbidity. In addition, the graft radiodensity ratio significantly changed at postoperative 1 and 6 months, possibly reflecting the inflammatory response and stabilization.

The Availability of Allogenic Fibular Bone Graft with Autogenous Bone Dust in Anterior Cervical Fusion after Cervical Discectomy (경추 추간판절제술후 전방 골유합시에 자가골분진을 충전시킨 동결건조된 동종비골이식의 유용성)

  • Lee, Sang Dae;Rhee, Dong Youl;Kim, Soo Young;Jeong, Young Gyun;Cho, Bong Soo;Park, Hyuck
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.1043-1049
    • /
    • 2000
  • Objective : This study was undertaken to evaluate the availability of allogenic fibular bone graft filled with autogenous bone dust in anterior cervical fusion after cervical discectomy. Methods : During a 4-year period(1995-1998), twenty four cases of anterior cervical fusion after discectomy were performed with fibular allograft filled with autogenous bone dust in degenerative cervical disease. We used freeze-dried fibular allograft and autogenous bone dust. Autogenous bone dust obtained from spondylotic spurs, osteophytes, and during foraminotomy. Cervical plating system was done at 8 patients. 5 patients were 1 level and 3 patients were 2 levels. All patients were routinely evaluated after surgery at 2 weeks, 1 month, 3 months, 5 months and 12 months. Mean follow-up period was 21months. Results : Eighty eight percent of the patients were found to have excellent or good clinical results. Radiographic follow-up revealed that 92% of the patients obtained complete or partial union by 5 months after surgery. One patient had graft extrusion immediately after surgery and had the graft reinserted. Two patients had longitudinal graft fractures. There were no graft related complications. Conclusion : Fibular allograft filled with autogenous bone dust for cervical interbody fusion after discectomy is an ideal graft material by showing obvious benefits of good fusion rate and elimination of donor site complications. And also we were able to obtain satisfactory clinical outcome.

  • PDF

Reduction of Inflammatory Reaction of PLGA Using Fibrin; in vivo Study (PLGA의 염증완화에 대한 피브린의 효과 ; In vivo 연구)

  • Kim, Su-Jin;Hong, Hyun-Hye;Kim, Soon-Hee;Kim, Hye-Lin;Kim, Se-Ho;Khang, Gil-Son
    • Polymer(Korea)
    • /
    • v.34 no.1
    • /
    • pp.63-68
    • /
    • 2010
  • In this study, we evaluated the effect of fibrin, a natural material, on the local inflammatory reaction of PLGA in vivo. PLGA degradation products can decrease the pH in the surrounding tissue, causing local inflammatory reaction. To solve this problem, fibrin/PLGA scaffolds were implanted in 5-week-old Wister rats. To evaluate the influence of fibrin content on inflammatory cytokine expression induced by PLGA, RT-PCR analysis was used. Fibrous wall thickness and macrophage infiltration were evaluated by H&E and ED-1 immunohistochemical staining, respectively. In this study, we showed that fibrin/PLGA scaffolds reduced inflammatory reaction as compared to PLGA scaffold. We concluded that fibrin could reduce inflammatory response of PLGA.

Effect of Hot-stamping on Microstructures and Tensile Properties of Al-Si Coated Boron Steel Welds with Laser Source (Al-Si 도금된 보론강 레이저 소스에 따른 레이저 용접부의 미세조직과 기계적 성질에 미치는 핫스탬핑 처리의 영향)

  • Oh, Myeong-Hwan;Kong, Jong-Pan;Kwon, Min-Suck;Kang, Chung-Yun
    • Journal of Welding and Joining
    • /
    • v.31 no.6
    • /
    • pp.96-106
    • /
    • 2013
  • In this study, the effect of laser source($CO_2$ and Nd:YAG) on the microstructure and tensile properties of laser welded Al-Si coated boron steel(1.2mmt) was investigated with before and after hot-stamping. In case of as welds condition, fracture occurred in base metal unrelated to the laser source. It could be explained that tensile strength of fusion zone composed of martensite and bainite is higher than that of base metal that contains a lot of ferrite despite dilution of Al and Si from coating layer to fusion zone. In case of hot-stamping condition, the fracture occurred in fusion zone irrelevant to laser source and the tensile strength was lower than hot stamped base metal. In the $CO_2$ laser welds, $Fe_3$(Al,Si) formed near the bond line was transformed into ferrite during hot-stamping. Therefore tensile strength of bond line is lower than that of base metal and center of fusion zone and the fracture occurred in the bond line. On the other hand, in the Nd:YAG laser welds, the higher concentration of Al formed the ferrite in the fusion zone during hot-stamping treatment. Also, the thickness of centerline was thinner than that of base metal. Therefore, it is considered that fracture occurred in centerline of fusion zone due to effect of concentration stress, and it leaded to a lower tensile strength and elongation.

Electrofusion Joining Technology for Polyethylene Pipes Using Carbon Fiber (탄소섬유를 이용한 Polyethylene배관의 전기융착 기술)

  • Ahn, Seok-Hwan;Ha, Yoo-Sung;Moon, Chang-Kwon
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.93-98
    • /
    • 2013
  • Fuel gas is an important energy source that is being increasingly used because of the convenience and clean energy provided. Natural gas is supplied to consumers safely through an underground gas-pipe network made of a polyethylene material. In electrofusion, which is one of the joining methods used, copper wire is used as the heating wire. However, it takes a long time for fusion to occur because the electrical resistance of copper is low. In this study, therefore, electrofusion was conducted by replacing the copper heating wire with carbon fiber to reduce the fusion time and improve the production when joining large pipes. Fusion and tensile tests were performed after the electrofusion joint was made in the polyethylene pipe using carbon fiber. The results showed that the fusion time was shorter and the temperature inside the pipe was higher with an increase in the current value. The ultimate tensile strength of specimens was higher than that of virgin polyethylene pipe, except for polyethylene pipes joined using a current of 0.8 A. The best fusion current value was 0.9 or 1.0 A because of the short fusion time and lack of transformation inside the pipe. Thus, it was shown that carbon fiber can be used to replace the copper heating wire.