• 제목/요약/키워드: fusion index

검색결과 232건 처리시간 0.02초

충남탄전(忠南炭田) 무연탄(無煙炭)의 특성(特性) (Property of the Jurassic anthracite (Anthracite from the Seongju Area of the Chungnam Coalfield))

  • 박석환;박홍수
    • 자원환경지질
    • /
    • 제22권2호
    • /
    • pp.129-139
    • /
    • 1989
  • The anthracite coalfields of Korea are confined to the areas where sedimentary rocks of Permian and Jurassic are preserved. The Chungnam coalfield lies in the sedimentary rocks of Jurassic which belongs to the Daedong Supergroup (the Nampo group). For the property analysis of each coal seam interbeded in Daedong Supergroup, Seongju area is chosen and twelve coalseams are taken. Many standard tests have been established for optical analysis (maceral analysis, coalification degree measurement), chemical analysis (proximate, ultimate analysis) and physical analysis (ignition temperature, ash fusion temperature, hardgrove grindability index and X-ray diffraction). The Jurassic anthracite mainly consist of vitrinite and macrinite and the range of the reflectance is $R_{max}$ 5.0-6.5 which means metaanthracite rank. By the chemical composition analysis, it shows low H/C and high O/C value compare with international average value. By the physical analysis, it has very high ignition temperature ($531-584^{\circ}C$) and ash fusion temperature ($1510-1700^{\circ}C$) and very low combustion velocity (0.2-1.9 mg/min). The very wide range of the hardgrove grindability index (46-132) means that the grindability controlled mainly by the structural conditions of coal bearing strata.

  • PDF

COSMO-SkyMed 2 Image Color Mapping Using Random Forest Regression

  • Seo, Dae Kyo;Kim, Yong Hyun;Eo, Yang Dam;Park, Wan Yong
    • 한국측량학회지
    • /
    • 제35권4호
    • /
    • pp.319-326
    • /
    • 2017
  • SAR (Synthetic aperture radar) images are less affected by the weather compared to optical images and can be obtained at any time of the day. Therefore, SAR images are being actively utilized for military applications and natural disasters. However, because SAR data are in grayscale, it is difficult to perform visual analysis and to decipher details. In this study, we propose a color mapping method using RF (random forest) regression for enhancing the visual decipherability of SAR images. COSMO-SkyMed 2 and WorldView-3 images were obtained for the same area and RF regression was used to establish color configurations for performing color mapping. The results were compared with image fusion, a traditional color mapping method. The UIQI (universal image quality index), the SSIM (structural similarity) index, and CC (correlation coefficients) were used to evaluate the image quality. The color-mapped image based on the RF regression had a significantly higher quality than the images derived from the other methods. From the experimental result, the use of color mapping based on the RF regression for SAR images was confirmed.

기술융합의 세계적 추세와 한국의 현황 비교분석 (A Comparative Study on the Trend of Technological Convergence)

  • 이준영;김도현;안세정;권오진;문영호
    • 대한산업공학회지
    • /
    • 제39권3호
    • /
    • pp.222-232
    • /
    • 2013
  • In recent years, 'technological fusion or convergence' has drawn a lot of attention of innovation researchers and governmental policy makers as the driving force of technological innovation and industrial growth. There are, however, few studies on the analysis of longitudinal trends of technological convergence and its comparison between global and national level. In this study, with the citation data of about 18 million articles, we analyzed 1) the growth of representative convergence research areas, 2) the convergence of citing patterns between research fields, and 3) the changing trend of diversity index of all research fields. We conclude that technological convergence in korea shows the relatively strong orientation to the combination of neighboring fields than that of heterogenous fields in comparison to global trend. In particular, the relatively weak activity of cognitive science and the low level of mutual exchange between arts/humanities/social sciences and natural/engineering sciences in Korea are emphasized.

융복합 농산업화 모델 유형별 잠재가능성 분석 - 밭작물 주산단지를 중심으로 - (Assessing the Potential of Fusion and Convergence in Industrial Agricultures - Focusing on Main Production Areas of Upland Crops -)

  • 이상현;김윤형;배승종;서동욱;오윤경
    • 농촌계획
    • /
    • 제26권2호
    • /
    • pp.25-37
    • /
    • 2020
  • The aim of this study is to assess the potential for fusion and convergence in industrial agriculture. First, we analyzed the types of industrial agriculture and applied the agri-business and ICT agriculture. After then, we analyzed the Project Potential Index (PPI) of the agri-business and ICT agriculture using the agricultural enterprise database provided from Rural Research Institute in Korea. The results revealed that Haenam have a high potential for agri-business project because of large number of farmers and annual sales. Wanju was considered as the suitable place for ICT agriculture project because of large area of greenhouse. This study was applied only 7 study area but the methodology suggested in this study could be widely used for assessing potential project various types of industrial agriculture.

Polarity Index Dependence of M13 Bacteriophage-based Nanostructure for Structural Color-based Sensing

  • Lee, Yujin;Moon, Jong-Sik;Kim, Kyujung;Oh, Jin-Woo
    • Current Optics and Photonics
    • /
    • 제1권1호
    • /
    • pp.12-16
    • /
    • 2017
  • Color sensor systems based on M13 bacteriophage are being considerably researched. Although many studies on M13 bacteriophage-based chemical sensing of TNT, endocrine disrupting chemicals, and antibiotics have been undertaken, the fundamental physical and chemical properties of M13 bacteriophage-based nanostructures require further research. A simple M13 bacteriophage-based colorimetric sensor was fabricated by a simple pulling technique, and M13 bacteriophage was genetically engineered using a phage display technique to exhibit a negatively charged surface. Arrays of structurally and genetically modified M13 bacteriophage that can determine the polarity indexes of various alcohols were found. In this research, an M13 bacteriophage-based color sensor was used to detect various types of alcohols, including methanol, ethanol, and methanol/butanol mixtures, in order to investigate the polarity-related property of the sensor. Studies of the fundamental chemical sensing properties of M13 bacteriophage-based nanostructures should result in wider applications of M13 bacteriophage-based colorimetric sensors.

Non-operative Korean Medicine Treatment for Four Patients with Failed Back Surgery Syndrome after Spinal Fusion Surgery : A Retrospective Case Series

  • Seo, Young Hoon;Lee, Jeong Ryo;Lee, Sang Min;Kim, Min Chul;Kim, Yu Jong;Hong, Je Rak;Kim, She Young;Seo, Young Woo;Kim, Ji Su;Park, Han Sol;Lee, Min ho;Kim, Tae Hun;Kim, Kiok
    • 대한한의학회지
    • /
    • 제37권2호
    • /
    • pp.93-103
    • /
    • 2016
  • Objectives: The purpose of this study was to report Four cases of Failed Back Surgery Syndrome (FBSS) patients after spinal fusion surgery who showed significant improvement in pain and function with Complex Korean medical treatment. Methods: This study was a retrospective observational study. We reviewed medical records of Four patients with lumbar pain or radiating leg pain, who have received spinal fusion surgery in the past. All Four patients took complex treatments of Mokhuri Neck and Back hospital which involes Acupuncture, Pharmaco-acupuncture, Gangchuk herbal medicine, Chuna and Physical therapy during about four-week of admission treatment. Visual Analogue Scale (VAS), Oswestry disability index (ODI), Pain Free Walking Distance (PFWD) scores were assessed before and after treatments. Results: The average of hospitalization period was 28.5 days. Mean VAS scores decreased from 6.5 to 2.3, Oswestry Disability Index (ODI) scores decreased from 56.25 to 38.25 and Pain Free Walking Distance (PFWD) also improved from 10m to 166.6m. Conclusion: This study implies that a combination of Korean medical treatments might be effective in relieving pain, and improving the functional status of FBSS patients. Further studies are needed to fully understand the mechanisms underlying the effects.

유기 발광소자의 효율 향상을 위한 광학박막 및 마이크로렌즈 설계 (Optical Thin Film and Micro Lens Design for Efficiency Improvement of Organic Light Emitting Diode)

  • 기현철;김두근;김선훈;김상기;박아름;구할본
    • 한국전기전자재료학회논문지
    • /
    • 제24권10호
    • /
    • pp.817-821
    • /
    • 2011
  • We have proposed an optical thin film and micro lens to improve the luminance of organic light emitting device. The first method, optical thin film was calculated refractive index of dielectric layer material that was modulated refractive index of organic material, ITO (indium tin oxide)and glass. The second method, microlens was applied with lenses on the organic device. Optical thin films were designed with Macleod Simulator and Micro Lenses were calculated by FDTD (finite-difference time-domain) solution. The structure of thin film was designed in organic material/ITO/dielectric layer/glass. The lenses size, height and distance were 5 ${\mu}m$, 1 ${\mu}m$, 1 ${\mu}m$, respectively. The material of micro lenses used silicon dioxide. Result, The highest luminance of OLED which applied with microlens was 11,185 $cd/m^2$, when approval voltage was 14.5 V, applied thin film was 5,857 $cd/m^2$. The device efficiency applying microlens increased 3 times than the device which does not apply microlens.

A Morphometric Analysis of Neuroforamen in Grade I Isthmic Spondylolisthesis by Anterior Lumbar Interbody Fusion with Pedicle Screw Fixation

  • Lee, Dong-Yeob;Lee, Sang-Ho;Kim, Seok-Kang;Maeng, Dae-Hyeon;Jang, Jee-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권6호
    • /
    • pp.377-381
    • /
    • 2007
  • Objective : The aim of this study was to evaluate the morphometric changes in neuroforamen in grade I isthmic spondylolisthesis by anterior lumbar interbody fusion [ALIF]. Methods : Fourteen patients with grade I isthmic spondylolisthesis who underwent single level ALIF with percutaneous pedicle screw fixation were enrolled. All patients underwent standing lateral radiography and magnetic resonance imaging [MRI] before surgery and at 1 week after surgery. For quantitative analysis, the foraminal height, width, epidural foraminal height, epidural foraminal width, and epidural foraminal area were evaluated at the mid-portion of 28 foramens using T2-weighted sagittal MRI. For qualitative analysis, degree of neural compression in mid-portion of 28 foramens was classified into 4 grades using T2-weighted sagittal MRI. Clinical outcomes were assessed using Visual Analogue Sale [VAS] scores for leg pain and Oswestry disability index before surgery and at 1 year after surgery. Results : The affected levels were L4-5 in 10 cases and L5-S1 in 4. The mean foraminal height was increased [p<0.001], and the mean foraminal width was decreased [p=0.014] significantly after surgery. The mean epidural foraminal height [p<0.001], epidural foraminal width [p<0.001], and epidural foraminal area [p<0.001] showed a significant increase after surgery. The mean grade for neural compression was decreased significantly after surgery [p<0.001]. VAS scores for leg pain [p=0.001] and Oswestry disability index [p=0.001] was decreased significantly at one year after surgery. Conclusion : Foraminal stenosis in grade I isthmic spondylolisthesis may effectively decompressed by ALIF with percutaneous pedicle screw fixation.

EPDM고무와 씨트라코닉산의 melt grafting - 반응조건과 개시제에 따른 영향 연구 - (Melt Grafting of Citraconic Acid onto an Ethylene-Propylene-Diene Terpolymer (EPDM) -Effect of Reaction Conditions and Initiator Type on the Melt Grafting of Citraconic Acid onto EPDM-)

  • 김정수;배종우;이진혁;오상택;김구니;이영희;김한도
    • Elastomers and Composites
    • /
    • 제48권1호
    • /
    • pp.39-45
    • /
    • 2013
  • Haake Rheocorder로 각종 과산화물 개시제를 사용하여 ethylene-propylene-diene terpolymer (EPDM)에 단량체 citraconic acid (CCA)을 용융 그라프트 중합을 하여 그라프트 중합물 CCA-g-EPDM을 얻었으며, 이때 효율적인 그라프트 정도와 우수한 성능을 지닌 그라프트 중합물을 얻기 위해서 최적의 반응조건과 최적의 단량체/개시제 농도를 찾는 것은 매우 중요하다. 따라서 본 연구에서는 반응조건과 단량체 및 개시제 함량이 CCA-g-EPDM의 그라프트 정도, 그라프트 효율, 가교정도 (겔화도), 용융흐름지수(MI) 및 기계적 물성 등에 미치는 영향에 초점을 맞추었다. 그라프트 정도와 가교도가 증가함에 따라서 인장강도는 상당히 증가한 반면, 파괴신도 및 MI는 감소하였다. 개시제 중에서 2,5-dimethyl-2,5-di(tert-butyl peroxy)-hexane (T-101)가 가장 우수한 그라프트 정도 (2.31%)를 나타내었으며, CCA와 T-101의 함량이 증가함에 따라 그라프트 정도가 크게 증가하였다. 그리고 그라프트 정도는 반응(혼합)온도 및 반응시간이 증가함에 따라 역시 증가하다가 어느 온도/시간 이상에서는 안정화 혹은 약간 감소하는 경향을 나타내었다. 이러한 영향으로 결과로부터 최적의 단량체/개시제 농도는 5/0.05 wt%이었으며, 최적의 반응온도/시간은 $180^{\circ}C$/15분인 것을 알 수 있었다.

Comparison of Outcomes after Atlantoaxial Fusion with Transarticular Screws and Screw-Rod Constructs

  • Kim, Ji Yong;Oh, Chang Hyun;Yoon, Seung Hwan;Park, Hyeong-Chun;Seo, Hyun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권5호
    • /
    • pp.255-260
    • /
    • 2014
  • Objective : The purpose of this study was to compare the radiological and neurological outcomes between two atlantoaxial fusion method for atlantoaxial stabilization; C1 lateral mass-C2 pedicle screws (screw-rod constructs, SRC) versus C1-2 transarticular screws (TAS). Methods : Forty-one patients in whom atlantoaxial instability was treated with atlantoaxial fixation by SRC group (27 patients, from March 2005 to May 2011) or TAS group (14 patients, from May 2000 to December 2005) were retrospectively reviewed. Numeric rating scale (NRS) for pain assessment, Oswestry disability index (ODI), and Frankel grade were also checked for neurological outcome. In radiologic outcome assessment, proper screw position and fusion rate were checked. Perioperative parameters such as blood loss during operation, operation time, and radiation exposure time were also reviewed. Results : The improvement of NRS and ODI were not different between both groups significantly. Good to excellent response in Frankel grade is shown similarly in both groups. Proper screw position and fusion rate were also observed similarly between two groups. Total bleeding amount during operation is lesser in SRC group than TAS group, but not significantly (p=0.06). Operation time and X-ray exposure time were shorter in SRC group than in TAS group (all p<0.001). Conclusion : Both TAS and SRC could be selected as safe and effective treatment options for C1-2 instability. But the perioperative result, which is technical demanding and X-ray exposure might be expected better in SRC group compared to TAS group.