• Title/Summary/Keyword: functional images

Search Result 504, Processing Time 0.029 seconds

Brain-wave Analysis using fMRI, TRS and EEG for Human Emotion Recognition (fMRI와 TRS와 EEG를 이용한 뇌파분석을 통한 사람의 감정인식)

  • Kim, Ho-Duck;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.6
    • /
    • pp.832-837
    • /
    • 2007
  • Many researchers are studying brain activity to using functional Magnetic Resonance Imaging (fMRI), Time Resolved Spectroscopy(TRS), Electroencephalography(EEG), and etc. They are used detection of seizures or epilepsy and deception detection in the main. In this paper, we focus on emotion recognition by recording brain waves. We specially use fMRI, TRS, and EEG for measuring brain activity Researchers are experimenting brain waves to get only a measuring apparatus or to use both fMRI and EEG. This paper is measured that we take images of fMRI and TRS about brain activity as human emotions and then we take data of EEG signals. Especially, we focus on EEG signals analysis. We analyze not only original features in brain waves but also transferred features to classify into five sections as frequency. And we eliminate low frequency from 0.2 to 4Hz for EEG artifacts elimination.

Trends of Tongue Features in Functional Dyspepsia Patients (기능성 소화불량 환자에서 설 지표의 경향성 파악)

  • Kim, Jihye;Ko, Seok-jae;Park, Jae-woo;Kim, Keun Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.4
    • /
    • pp.637-644
    • /
    • 2018
  • Objectives: In this study, the tongue features of patients with functional dyspepsia (FD) were compared with those of healthy controls. Methods: This prospective, case-control study was conducted on patients with FD and controls recruited at a single center. After screening, the subjects were allocated to the patient or control groups (patients=42, controls=40). Tongue images were acquired using a computerized tongue image acquisition system (CTIS). An independent t-test was conducted to compare the measurements from patients and controls. Binary logistic regression was performed to determine significant differences between the two groups after adjusting for age and sex. Results: The CIE $a^*$ color value in the tongue coating area was significantly lower in the patients with FD than in the controls (p=0.001). The tongue coating ratios were also significantly higher in the FD group than in the control group (p=0.003). We found that the CIE $a^*$ color value in the tongue coating area and the tongue coating ratios were significant predictive factors in both groups, based on binary regression analysis (p=0.016, 0.044, respectively). Conclusions: This study found that FD was significantly associated with CIE $a^*$ color value in the tongue coating area and tongue coating ratios. We suggest that these factors could be used as objective indicators of FD.

Reorganization of Motor Network and the Effect of Cross Education Derived From Unilateral Coordination Training (편측 협응훈련에 의한 운동신경망의 재조직 및 교차훈련의 효과 -사례연구-)

  • Park, Ji-Won;Kim, Jong-Man;Seo, Jeong-Hwan;Kim, Yun-Hee
    • Physical Therapy Korea
    • /
    • v.9 no.3
    • /
    • pp.67-76
    • /
    • 2002
  • We report the reorganization of motor network resulted from intensive unilateral coordination training and the effect of cross education on the untrained side in patient with traumatic brain injury using functional magnetic resonance imaging (fMRI). A 22 year-old male patient who had suffered from diffuse axonal injury for 58 months showed coordination deficit in the left hand at initial examination. Intensive motor training including complex finger movements and coordination activities using a metronome was introduced to the patient 4 hours per day for a week. FMRI was performed on a 3T ISOL Forte scanner. All functional images were analyzed using SPM-99 software. Hand function was improved after training not only in the trained left hand, but also in the untrained right hand. There was no activation in the right primary motor area (M1) during left hand movement before training whereas robust activation of left M1 was demonstrated by the right hand movement. Profuse activation of bilateral prefrontal lobes was seen during both hand movements before training. After training of left hand, right M1 became prominently activated during the left hand motion. The activation of bilateral prefrontal lobes disappeared after training not only for the left hand movement but also for the right, which clearly demonstrated the effect of cross education. This case report demonstrated the learning-dependent reorganization of the M1 and the effect of cross education.

  • PDF

A Study on Dynamic Material Properties of Functional High Explosive Formulation Simulant Subjected to Dynamic Loading (동적하중을 받는 기능성 고폭화약조성 시뮬런트 재료물성 연구)

  • Park, Jungsu;Yeom, Kee Sun;Park, Chunghee;Jeong, Sehwan;Lee, Keundeuck;Huh, Hoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.857-866
    • /
    • 2013
  • This paper is concerned with the material properties of functional high explosive(FHX) simulant at various strain rates ranging from $10^{-4}/sec$ to $10^1/sec$. Material properties of FHX at high strain rates are important in prediction of deformation modes of FHX in a warhead which undergoes dynamic loading. Inert FHX stimulant which has analogous mechanical properties with FHX was utilized for material tests due to safety issues. Uniaxial tensile tests at quasi-static strain rates ranging from $10^{-4}/sec$ to $10^{-2}/sec$ and intermediate strain rates ranging from $10^{-1}/sec$ to $10^1/sec$ were conducted with JANNAF specimen using a tensile testing machine, INTRON 5583, and developed high speed material testing machine, respectively. Uniaxial compressive tests at quasi-static strain rates and intermediate strain rates were conducted with cylindrical specimen using a dynamic materials testing machine, INSTRON 8801. And cyclic compressive loading tests were performed with various strain rates and strains. Deformation behaviors were investigated using captured images obtained from a high-speed camera.

Effects of Bu-Zhong-Yi-Qi-Tang for the treatment of functional dyspepsia: a feasibility study protocol

  • Kim, Jihye;Kim, Hyunho;Kim, Keun Ho
    • Integrative Medicine Research
    • /
    • v.6 no.3
    • /
    • pp.317-324
    • /
    • 2017
  • Background: Bu-Zhong-Yi-Qi-Tang (BZYQT) has long been used for the treatment of severe weakness caused by general fatigue, loss of appetite, or indigestion. The aim of this feasibility study is to assess the effectiveness and safety of BZYQT for the treatment of functional dyspepsia (FD) with spleen qi deficiency. Methods: This study will be conducted at a single center as a prospective, nonrandomized, nonblinded, single-arm feasibility study. A total of 30 participants diagnosed with FD in accordance with the Rome III criteria will be enrolled. All patients will receive BZYQT for 4 weeks. The primary outcome is the change in the Nepean Dyspepsia Index-Korean version (NDI-K) scores between the baseline and 4-week images. The secondary outcomes include the tongue coating thickness, blood parameters, and BZYQT Questionnaire score. The NDI-K score will be acquired four times, at Weeks 0 (baseline), 2 (during treatment), 4 (after treatment), and 8 (after follow-up). Written informed consent will be obtained from all study participants prior to enrollment. This study has been approved by the Institutional Review Board of Kyung Hee University Korean Medicine Hospital. This study protocol is registered with the national clinical trial registry of the World Health Organization International Clinical Trials Registry Platform. Results will be published in a journal and will be disseminated both electronically and in print. Discussion: The results of this study may serve as a guide for researchers seeking to effectively evaluate the effects of BZYQT.

Quality Evaluation of Ultrasonographic Equipment Using an ATS-539 Multipurpose Phantom in Veterinary Medicine

  • Cho, Young-kwon;Lee, Youngjin;Lee, Kichang
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.114-120
    • /
    • 2022
  • The purpose of this study is to examine the status of quality control using multipurpose phantom of ultrasound equipment used in hospital of veterinary college in South Korea by using ATS-539 multipurpose phantom so as to examine quantitative and objective new image evaluation method. Specialists discussed and analyzed multipurpose phantom images acquired by using convex transducer of 10 ultrasound imaging devices, currently used in 9 veterinary colleges, at 4.0-6.0 MHz. Total 8 items that can be measured with ATS-539 multipurpose phantom including dead zone, vertical and horizontal measurement, axial/lateral resolution, sensitivity, focal zone, functional resolution and gray scale/dynamic range were evaluated. For qualitative evaluation, valid decisions were made based on dead zone, axial/lateral resolution, and gray scale/dynamic range which are resolution index, and coefficient of variation (COV) and blind referenceless image spatial quality evaluator (BRISQUE) were found to increase objectivity. As a result of experiment, all the targeted ultrasonic devices were found appropriate from qualitative evaluation items of dead zone, axial/lateral resolution, and gray scale/dynamic range. In other evaluation items, they were found to be appropriate from focal zone and vertical measurement of quantitative evaluation while inappropriate from horizontal measurement, sensitivity, and functional resolution. COV value was 0.12 ± 0.04, and BRISQUE value was 47.77 ± 2.77, both analysis results show that the noise level of all ultrasonic devices was located within tolerance range. Upon image examination using ATS-539 multipurpose phantom, they were 100% appropriate with inspection standards of dead zone, axial/lateral resolution, and gray scale/dynamic range, and besides, focal zone and functional resolution can be used as evaluation items. In the field of veterinary medicine, 8 standard items using ATS-539 multipurpose phantom and image evaluation items using COV and BRISQUE can be used as standards for quality control of ultrasonography machine.

A Reproducible and Reliable Method for Measuring Masseter Muscle Thickness in Maximal Bite Force Using Ultrasonography

  • Hyun-Jeong Park;Sun-Kyoung Yu;Yo-Seob Seo;Ji-Won Ryu
    • Journal of Oral Medicine and Pain
    • /
    • v.47 no.4
    • /
    • pp.206-211
    • /
    • 2022
  • Purpose: The purpose of this study is to develop a reproducible and reliable method for evaluating the masseter's functional state by measuring the masseter muscle with ultrasonography (US). Methods: Nineteen healthy adults (9 males, 10 females) were the subjects of this study. During US scanning, the image was taken from the thickest part of the masseter muscle in the image. To evaluate changes in thickness during masseter function, US images were taken of the participant's masseter muscle at rest and during clenching. In this study, US scanning was conducted using two approaches to compare the difference in masseter muscle thickness determined when inducing maximum bite force (MBF). Results: All 19 subjects completed US scanning of the masseter muscle at rest and during clenching under the conventional method and the articulation paper method. There was no difference in masseter muscle thickness measured at rest. However, the thickness of the masseter muscles determined by the articulation paper during jaw clenching was greater than that measured by the conventional method. Conclusions: In conclusion, using the US for masseter muscle evaluation can offer objective and functional information on the masseter muscle. A standardized US scanning method needs to be developed to obtain reproducible and reliable information on the masseter muscle at rest and during clenching. In particular, generating MBF using an articulation paper can be a reproducible and reliable method of measuring the functional state of the masseter muscle.

Quantification of Brain Images Using Korean Standard Templates and Structural and Cytoarchitectonic Probabilistic Maps (한국인 뇌 표준판과 해부학적 및 세포구축학적 확률뇌지도를 이용한 뇌영상 정량화)

  • Lee, Jae-Sung;Lee, Dong-Soo;Kim, Yu-Kyeong;Kim, Jin-Su;Lee, Jong-Min;Koo, Bang-Bon;Kim, Jae-Jin;Kwon, Jun-Soo;Yoo, Tae-Woo;Chang, Ki-Hyun;Kim, Sun-I.;Kang, Hye-Jin;Kang, Eun-Joo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.241-252
    • /
    • 2004
  • Purpose: Population based structural and functional maps of the brain provide effective tools for the analysis and interpretation of complex and individually variable brain data. Brain MRI and PET standard templates and statistical probabilistic maps based on image data of Korean normal volunteers have been developed and probabilistic maps based on cytoarchitectonic data have been introduced. A quantification method using these data was developed for the objective assessment of regional intensity in the brain images. Materials and Methods: Age, gender and ethnic specific anatomical and functional brain templates based on MR and PET images of Korean normal volunteers were developed. Korean structural probabilistic maps for 89 brain regions and cytoarchitectonic probabilistic maps for 13 Brodmann areas were transformed onto the standard templates. Brain FDG PET and SPGR MR images of normal volunteers were spatially normalized onto the template of each modality and gender. Regional uptake of radiotracers in PET and gray matter concentration in MR images were then quantified by averaging (or summing) regional intensities weighted using the probabilistic maps of brain regions. Regionally specific effects of aging on glucose metabolism in cingulate cortex were also examined. Results: Quantification program could generate quantification results for single spatially normalized images per 20 seconds. Glucose metabolism change in cingulate gyrus was regionally specific: ratios of glucose metabolism in the rostral anterior cingulate vs. posterior cingulate and the caudal anterior cingulate vs. posterior cingulate were significantly decreased as the age increased. 'Rostral anterior'/'posterior' was decreased by 3.1% per decade of age ($P<10^{-11}$, r=0.81) and 'caudal anterior'/'posterior' was decreased by 1.7% ($P<10^{-8}$, r=0.72). Conclusion: Ethnic specific standard templates and probabilistic maps and quantification program developed in this study will be useful for the analysis of brain image of Korean people since the difference in shape of the hemispheres and the sulcal pattern of brain relative to age, gender, races, and diseases cannot be fully overcome by the nonlinear spatial normalization techniques.

Usefulness of "Volumetrix Suite" with SPECT/CT (SPECT/CT 영상에서 Volumetrix Suite의 유용성)

  • Cho, Seung-Wook;Shin, Byeong-Ho;Kim, Jong-Pil;Yoon, Seok-Hwan;Kim, Tae-Yeub;Seung, Yong-Joon;Moon, Il-Sang;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.166-171
    • /
    • 2010
  • Purpose: The SPECT/CT is able to acquire diagnostic information resolved the difficult problems that discriminate regions of focals by intergrating functional images and anatomical images. We introduce the usefulness of "Volumetrix Suite" which can describe 3D images by the convergence of the SPECT/CT images and reference CT images. Materials and Methods: We applied Volumetrix Suite program (Volumetrix IR, Volumetrix 3D) to patients, Bone, Venography, Parathyroid, WBC, taken diagnostic CT examination which have same regions of focal in Seoul Metropolitan Government Seoul National University Boramae Medical Center. After acquiring SPECT/CT images and reference CT images, we fused a couple of scans applying for this programs. The CT scan of Infinia Hawkeye 4 shows limitation of anatomical information. For this reason, we tried to transfer CT images that have lots of diagnostic informations as the form of Dicom file in PACS, and changed from 2D images to 3D images after image registering in Xeleris Workstaion of Hawkeye 4. Results & Conclusion: By using Volumetrix Suite program, we're able to acquire more accurate anatomical informations with 3D rendering which can distinguish both location and range of focals in Infinia Hawkeye 4. Thus, the result of utilizing this program indicate that nuclear medicine anatomical images can be improved by providing more diagnostic imformations produced by its program.

  • PDF

IMAGE SIMULATIONS FOR THE KVN USING THE VLBA IMAGE OF SiO MASERS (SiO MASERS의 VLBA 이미지를 이용한 KVN 이미지 모의실험)

  • Yi, Ji-Yune;Jung, Tae-Hyun
    • Publications of The Korean Astronomical Society
    • /
    • v.23 no.2
    • /
    • pp.37-45
    • /
    • 2008
  • We present the results of image simulations of 43.1 GHz SiO maser emission toward a Mira variable using the KVN (Korean VLBI Network) and other facilities which can make joint VLBI experiments with the KVN. To test the imaging capability of the KVN we used the image of SiO masers in the simulation obtained by the VLBA, which is considered to be the optimum VLBI facility at present to study SiO masers toward evolved stars. The simulated images of SiO maser emission confirm that coordinate VLBI expriments of KVN with several more stations in Japan or in the neighborhood of Korean Peninsula are necessary to exert the functional benefit of the KVN as the first mm VLBI facility which can perform simultaneous observations at four different frequency bands.