• Title/Summary/Keyword: function-safe

Search Result 728, Processing Time 0.03 seconds

A Method of Reducing a Tolerance of a Shunt Resistor for Balance of the Battery Cell to Improve a Precision of BMS (BMS 정밀도 향상을 위한 셀 밸런싱용 션트 고정저항의 허용오차 저감 방법)

  • Kim, Eun-Min;Son, Mi-Ra;Kang, Chang-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1055-1061
    • /
    • 2018
  • Recently, due to the rapid development of electric vehicle and energy storage system, it is emphasized for battery management system to be needed and to be improved. BMS carries out various movement for optimization the use of the energy and safe use of secondary battery, these movement of BMS start at high wattage shunt fixed resistor which performs a function for detecting current among the BMS components. In addition, for the safe operation of secondary battery, the reliability of current voltage variation detected from shunt should be secured, and for corresponding characteristics, the quality of Temperature coefficient of resistance for BMS shunt and the quality of Thermo electromotive force all must be excellent. For these reasons, this study comes up with the stabilization plan for thermo electromotive force and temperature coefficient of resistance of BMS shunt resistor which is key to secondary battery operation.

Proposal of safe fire escape system for the day-care center and the kindergarten (어린이집 및 유치원의 화재 대피용 안전 경로 시스템 제안)

  • Choi, Jun-Ho;Kwon, Mee-Rhan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.297-301
    • /
    • 2015
  • Day-care centers and kindergartens are increasing along with the damage caused by fire year after year. Infants and toddlers have a low response capability than adults to fire situations such as heavy smoke which causes less or zero visibility thus it is difficult in evacuation route during dangerous fire situations. Because of these circumstances, teachers need to build a safe pathway signage system along with the usual fire safety training needs of infants and children. In this paper, we propose a system for fire escape which marks the escape routes and are automatically implemented through the push function that smartphone recognizes during the real-time fire situation, and establish a system that verifies its authenticity.

Determination of an Optimal Sentence Segmentation Position using Statistical Information and Genetic Learning (통계 정보와 유전자 학습에 의한 최적의 문장 분할 위치 결정)

  • 김성동;김영택
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.10
    • /
    • pp.38-47
    • /
    • 1998
  • The syntactic analysis for the practical machine translation should be able to analyze a long sentence, but the long sentence analysis is a critical problem because of its high analysis complexity. In this paper a sentence segmentation method is proposed for an efficient analysis of a long sentence and the method of determining optimal sentence segmentation positions using statistical information and genetic learning is introduced. It consists of two modules: (1) decomposable position determination which uses lexical contextual constraints acquired from a training data tagged with segmentation positions. (2) segmentation position selection by the selection function of which the weights of parameters are determined through genetic learning, which selects safe segmentation positions with enhancing the analysis efficiency as much as possible. The safe segmentation by the proposed sentence segmentation method and the efficiency enhancement of the analysis are presented through experiments.

  • PDF

A Study on Safe Hiking According to Caution Against Cardiac Arrest That Occurs Unexpectedly during Mountaineering (등산 중 발생하는 심정지 주의에 따른 안전산행 연구)

  • Park, Ok-Nam;OH, Hye-Ryeong
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.129-130
    • /
    • 2023
  • The From COVID-19 until recently, the demand for hiking has been rapidly increasing due to the popularization of mountain seekers.,On weekends and holidays, people who do not hike frequently while hiking in large and small mountains to see wildflowers and foliage in the mountains are more likely to be exposed to safety accidents due to an increase in sudden muscle use.,If you fall or get muscle damage during a hike, you can prevent a major accident with a simple treatment. In some cases, the error of first aid may permanently damage the important function of the body.,In particular, during a safety accident on a mountain, while climbing in light clothes, the body temperature rises due to the sweat that was shed at the beginning, and the blood pressure rises due to the contraction of the blood vessels due to the drop in body temperature from the top, resulting in an emergency such as cardiac arrest.,According to statistics from the National Park Service, nearly half (48%) of deaths in national parks are known to be sudden cardiac deaths.,There are many safety accidents that occur frequently in the mountains, but among them, we will study how to cope with acute diseases such as cardiac arrest due to increased blood pressure due to insufficient body temperature control, chest pain or dyspnea, and heart burden due to excessive hiking.

  • PDF

Safety of Industrial Overhead Doors : A Review of Maintenance and Parallel Safety Devices (산업용 오버헤드 도어의 사고 예방 : 유지관리 및 병렬구조 안전장치를 중심으로)

  • Bok Ki Kim;Jaewook Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.33-40
    • /
    • 2024
  • This study analyzes the impact of regular preventive maintenance (PM) on reducing the failure rate and occurrence of falling accidents of industrial overhead doors. A reliable safety device model with an additional safety device, which is installed to replace a defective one, is proposed. The research methodology involves collecting breakdown and falling accident records, comparing and analyzing data before and after regular PM implementation, and experimenting with two types of retrofittable safety devices. Key findings are as follows. 1. Regular PM implementation significantly reduces the failure rate of old overhead doors. 2. A parallel structured model with two alternative safety devices can minimize falling accident risks. The study's contributions include the following. 1. The positive impact of PM on extending overhead door lifespan is quantified. 2. A general safety device model that can be retrofitted and used as replacement with a fail-safe function is proposed.

Development of a Model for Physiological Safe Work Load from a Model of Metabolic Energy for Manual Materials Handling Tasks (에너지 대사량을 고려한 인력물자취급시의 생리적 안전 작업하중 모델 개발)

  • Kim Hong-Ki
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.27 no.3
    • /
    • pp.90-96
    • /
    • 2004
  • The objective of this study was to develop a model for safe work load based on a physiological model of metabolic energy of manual material handling tasks. Fifteen male subjects voluntarily participated in this study. Lifting activities with four different weights, 0, 8, 16, 24kg, and four different working frequencies (2, 5, 8, 11 lifts/min) for a lifting range from floor to the knuckle height of 76cm were considered. Oxygen consumption rates and heart rates were measured during the performance of sixteen different lifting activities. Simplified predictive equations for estimating the oxygen consumption rate and the heart rate were developed. The oxygen consumption rate and the heart rate could be expressed as a function of task variables; frequency and the weight of the load, and a personal variable, body weight, and their interactions. The coefficients of determination ($r^2$) of the model were 0.9777 and 0.9784, respectively, for the oxygen consumption rate and the heart rate. The model of oxygen consumption rate was modified to estimate the work load for the given oxygen consumption rate. The overall absolute percent errors of the validation of this equation for work load with the original data set was 39.03%. The overall absolute percent errors were much larger than this for the two models based on the US population. The models for the oxygen consumption rate and for the work load developed in this study work better than the two models based on the US population. However, without considering the biomechanical approach, the developed model for the work load and the two US models are not recommended to estimate the work loads for low frequent lifting activities.

Ad-hoc Security Authentication Technique based on Verifier (검증자 기반 Ad-hoc 보안 인증기법)

  • Lee, Cheol-Seung;Hong, Seong-Pyo;Lee, Ho-Young;Lee, Joon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.713-716
    • /
    • 2007
  • This paper suggests One-time Password key exchange authentication technique for a strong authentication based on Ad-hoc Networks and through identify wireless environment security vulnerabilities, analyzes current authentication techniques. The suggested authentication technique consists of 3 steps: Routing, Registration, and Running. The Routing step sets a safe route using AODV protocol. The Registration and Running step apply the One-time password S/key and the DH-EKE based on the password, for source node authentication. In setting the Session key for safe packet transmission and data encryption, the suggested authentication technique encrypts message as H(pwd) verifiers, performs key exchange and utilizes One time password for the password possession verification and the efficiency enhancement. EKE sets end to end session key using the DH-EKE in which it expounds the identifier to hash function with the modula exponent. A safe session key exchange is possible through encryption of the H(pwd) verifier.

  • PDF

Fabrication and Characterisitics of Al2O3-SiC Ceramic Composites for Electrostatic Discharge Safe Components (대전방지용 Al2O3-SiC 복합세라믹 소결체의 제조 및 특성)

  • Kim, Ha-Neul;Oh, Hyun-Myung;Park, Young-Jo;Ko, Jae-Woong;Lee, Hyun-Kwuon
    • Journal of Powder Materials
    • /
    • v.25 no.2
    • /
    • pp.144-150
    • /
    • 2018
  • $Al_2O_3-SiC$ ceramic composites are produced using pressureless sintering, and their plasma resistance, electrical resistance, and mechanical properties are evaluated to confirm their applicability as electrostatic-discharge-safe components for semiconductor devices. Through the addition of Mg and Y nitrate sintering aids, it is confirmed that even if SiC content exceeded 10%, complete densification is possible by pressureless sintering. By the uniform distribution of SiC, the total grain growth is suppressed to about $1{\mu}m$; thus an $Al_2O_3-SiC$ sintered body with a high strength over 600 MPa is obtained. The optimum amount of SiC to satisfy all the desired properties of electrostatic-discharge-safe ceramic components is obtained by finding the correlation between the plasma resistance and the electrical resistivity as a function of SiC amount.

Testing of Common Electromagnetic Environments for Risk of Interference with Cardiac Pacemaker Function

  • Tiikkaja, Maria;Aro, Aapo L.;Alanko, Tommi;Lindholm, Harri;Sistonen, Heli;Hartikainen, Juha E.K.;Toivonen, Lauri;Juutilainen, Jukka;Hietanen, Maila
    • Safety and Health at Work
    • /
    • v.4 no.3
    • /
    • pp.156-159
    • /
    • 2013
  • Background: Cardiac pacemakers are known to be susceptible to strong electromagnetic fields (EMFs). This in vivo study investigated occurrence of electromagnetic interference with pacemakers caused by common environmental sources of EMFs. Methods: Eleven volunteers with a pacemaker were exposed to EMFs produced by two mobile phone base stations, an electrically powered commuter train, and an overhead high voltage transmission lines. All the pacemakers were programmed in normal clinically selected settings with bipolar sensing and pacing configurations. Results: None of the pacemakers experienced interference in any of these exposure situations. However, often it is not clear whether or not strong EMFs exist in various work environments, and hence an individual risk assessment is needed. Conclusions: Modern pacemakers are well shielded against external EMFs, and workers with a pacemaker can most often return to their previous work after having a pacemaker implanted. However, an appropriate risk assessment is still necessary after the implantation of a pacemaker, a change of its generator, or major modification of its programming settings.

Finger Printing Based Radio Positioning Scheme for Maritime Safety (수상 안전을 위한 Finger Printing 기반 무선 위치추적 기술)

  • Seok, Keun Young;Ryu, Jong Yeol;Lee, Jung Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.1001-1008
    • /
    • 2018
  • In this paper, we propose an efficient location tracking scheme using wireless signals for various situations in marine environment that requires location information for many reasons such as lifesaving, accident prevention, and facility management. Our proposed location tracking scheme not only monitors user's location, but also minimizes the risk under the user's limited battery power budget. The position of a user can be obtained at base stations from the strengths of the received signals from the user. In this case, it may require to prevent the user from getting out of the predetermined safe area. For each location in the safe area, we define a risk function, which is influenced by many factors such as location accuracy, depth, flow rate, and geometry. Our proposed scheme is based on finger printing technique and aims at minimizing the average risk of each user in the safe area.