• 제목/요약/키워드: full-scale measurements

검색결과 147건 처리시간 0.026초

Experimental and finite element parametric investigations of the thermal behavior of CBGB

  • Numan, Hesham A.;Taysi, Nildim;Ozakca, Mustafa
    • Steel and Composite Structures
    • /
    • 제20권4호
    • /
    • pp.813-832
    • /
    • 2016
  • This research deals with the behavior of Composite Box Girder Bridges (CBGBs) subjected to environmental effects such as solar radiation, atmospheric temperature, and wind speed. It is based on temperature and thermal stress results, which were recorded hourly from a full-scale experimental CBGB segment and Finite Element (FE) thermal analysis. The Hemi-cube method was adopted to achieve the accuracy in temperature distributions and variations in a composition system during the daily environmental variations. Analytical findings were compared with the experimental measurements, and a good agreement was found. On the other hand, parametric investigations are carried out to investigate the effect of the cross-section geometry and orientation of the longitudinal axis of CBGB on the thermal response and stress distributions. Based upon individual parametric investigations, some remarks related to the thermal loading parameters were submitted. Additionally, some observations about the CBGB configurations were identified, which must be taken into account in the design process. Finally, this research indicates that the design temperature distribution with a uniform differential between the concrete slab and the steel girder is inappropriate for describing the thermal impacts in design objective.

A review of cognitive orientation to daily occupational performance with stroke

  • Ahn, Si-Nae
    • Physical Therapy Rehabilitation Science
    • /
    • 제6권4호
    • /
    • pp.202-207
    • /
    • 2017
  • Objective: The self-decisions of the client regarding the meaningful work as a therapeutic approach of client-orientation. The Cognitive Orientation to daily Occupational Performance (CO-OP) is an occupation-oriented problem-solving approach. The purpose of this study was to describe the goals and intervention protocols of CO-OP in those affected by stroke. Design: A systematic review. Methods: Using EBSCOhost, PubMed, and ProQuest databases, we searched studies published in the past decade that utilized the CO-OP intervention. An initial search revealed 71,171 potential articles. After applying our search criteria to screen the titles, abstracts, and full-text, we included 7 articles that met our inclusion and exclusion criteria. In this study, we used the patient, intervention(s), comparison, outcome method to analyze the 7 selected studies. We analyzed the frequency of goals and intervention protocols. Results: Seven articles met our selection criteria; these studies included participants with an almost normal cognitive function from inpatient and outpatient rehabilitation facilities. CO-OP was used for 237 goals; the most used goal was the instrumental activities of daily living. The training procedure used 3 types of self-selecting goals in the activities. One of the goals was not trained, but was only evaluated to determine the generation effect. The most common outcome measurements included the Canadian Occupational Performance Measure and the Performance Quality Rating Scale. Conclusions: This research provided information about the effectiveness of CO-OP and selecting the correct evaluation tool to assess the efficiency of the intervention. This study suggests that treatment with CO-OP in occupational therapy is effective and that it outlines common protocols.

실지형을 지나는 대기유동에 대한 수치모델의 검증 (Validation of Numerical Model for the Wind Flow over Real Terrain)

  • 김현구;이정묵;노유정
    • 한국대기환경학회지
    • /
    • 제14권3호
    • /
    • pp.219-228
    • /
    • 1998
  • In the present investigation, a numerical model developed for the prediction of the wind flow over complex terrain is validated by comparing with the field experiments. For the solution of the Reynolds - Averaged Clavier- stokes equations which are the governing equations of the microscale atmospheric flow, the model is constructed based on the finite-volume formulation and the SIMPLEC pressure-correction algorithm for the hydrodynamic computation. The boundary- fitted coordinate system is employed for the detailed depiction of topography. The boundary conditions and the modified turbulence constants suitable for an atmospheric boundary- layer are applied together with the k- s turbulence model. The full- scale experiments of Cooper's Ridge, Kettles Hill and Askervein Hill are chosen as the validation cases . Comparisons of the mean flow field between the field measurements and the predicted results show good agreement. In the simulation of the wind flow over Askervein Hill , the numerical model predicts the three dimensional flow separation in the downslope of the hill including the blockage effect due to neighboring hills . Such a flow behavior has not been simulated by the theoretical predictions. Therefore, the present model may offer the most accurate prediction of flow behavior in the leeside of the hill among the existing theoretical and numerical predictions.

  • PDF

Design and performance validation of a wireless sensing unit for structural monitoring applications

  • Lynch, Jerome Peter;Law, Kincho H.;Kiremidjian, Anne S.;Carryer, Ed;Farrar, Charles R.;Sohn, Hoon;Allen, David W.;Nadler, Brett;Wait, Jeannette R.
    • Structural Engineering and Mechanics
    • /
    • 제17권3_4호
    • /
    • pp.393-408
    • /
    • 2004
  • There exists a clear need to monitor the performance of civil structures over their operational lives. Current commercial monitoring systems suffer from various technological and economic limitations that prevent their widespread adoption. The wires used to route measurements from system sensors to the centralized data server represent one of the greatest limitations since they are physically vulnerable and expensive from an installation and maintenance standpoint. In lieu of cables, the introduction of low-cost wireless communications is proposed. The result is the design of a prototype wireless sensing unit that can serve as the fundamental building block of wireless modular monitoring systems (WiMMS). An additional feature of the wireless sensing unit is the incorporation of computational power in the form of state-of-art microcontrollers. The prototype unit is validated with a series of laboratory and field tests. The Alamosa Canyon Bridge is employed to serve as a full-scale benchmark structure to validate the performance of the wireless sensing unit in the field. A traditional cable-based monitoring system is installed in parallel with the wireless sensing units for performance comparison.

Wind Tunnel Test of an Unmanned Aerial Vehicle (UAV)

  • Chung, Jin-Deog;Lee, Jang-Yeon;Sung, Bong-Zoo;Koo, Sa-Mok
    • Journal of Mechanical Science and Technology
    • /
    • 제17권5호
    • /
    • pp.776-783
    • /
    • 2003
  • A low speed wind tunnel test was conducted for full-scale model of an unmanned aerial vehicle (UAV) in Korea Aerospace Research Institute (KARI) Low Speed Wind Tunnel(LSWT). The purpose of the presented paper is to illustrate the general aerodynamic and performance characteristics of the UAV that was designed and fabricated in KARI. Since the testing conditions were represented minor portions of the load-range of the external balance system, the repeatability tests were performed at various model configurations to confirm the reliability of measurements. Variations of drag-polar by adding model components such as tails, landing gear and test boom are shown, and longitudinal and lateral aerodynamic characteristics after changing control surfaces such as aileron, flap, elevator and rudder are also presented. To explore aerodynamic characteristics of an UAV with model components build-up and control surface deflections, lift curve slope, pitching moment variation with lift coefficients and drag-polar are examined. The discussed results might be useful to understand the general aerodynamic characteristics and drag pattern for the given UAV configuration.

식물에 의한 계절별 실내공기오염물질 저감효과에 관한 연구 (A Study on Indoor Air Pollutants Reduction Effect by Plants per Season)

  • 손정은;김용식;손장열
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.25-30
    • /
    • 2008
  • This study aims at examining the reduction of indoor air contaminants by plants placed in an indoor space. The effect of reducing the concentration of air contaminants by three species of plants was studied in a full-scale mock-up model. Field measurements were performed using Aglaonema brevispathum, Pachira aquatica and Ficus benjamiana which were verified as air-purifying plants by NASA. Their positions and amount were controlled. Two conditions for the amount of plants(10%, 5%) and positions(sun-shine, scatter) were used in two separate rooms whose dimensions are identical. The concentration of Volatile Organic Compounds(VOCs) was monitored three hours after the plants were placed and three days after the plants were placed. The variations of concentration of Benzene, Toluene, Etylbenzene, Xylene, Stylene and Formaldehyde, which are all known as the major elements of Volatile Organic Compounds were monitored. The more plants were used, the more a reduction of indoor air contaminants occurred. The effect of reducing the concentration of air contaminants increased when the amount of plants increased.

Hydro-structural issues in the design of ultra large container ships

  • Malenica, Sime;Derbanne, Quentin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권4호
    • /
    • pp.983-999
    • /
    • 2014
  • The structural design of the ships includes two main issues which should be checked carefully, namely the extreme structural response (yielding & buckling) and the fatigue structural response. Even if the corresponding failure modes are fundamentally different, the overall methodologies for their evaluation have many common points. Both issues require application of two main steps: deterministic calculations of hydro-structure interactions for given operating conditions on one side and the statistical post-processing in order to take into account the lifetime operational profile, on the other side. In the case of ultra large ships such as the container ships and in addition to the classical quasi-static type of structural responses the hydroelastic structural response becomes important. This is due to several reasons among which the following are the most important: the increase of the flexibility due to their large dimensions (Lpp close to 400 m) which leads to the lower structural natural frequencies, very large operational speed (> 20 knots) and large bow flare (increased slamming loads). The correct modeling of the hydroelastic ship structural response, and its inclusion into the overall design procedure, is significantly more complex than the evaluation of the quasi static structural response. The present paper gives an overview of the different tools and methods which are used in nowadays practice.

The Binding of Human CLIC1 with SEDL and Its Characterization in vitro

  • Park, Jeong-Soon;Lee, Kyoung-Mi;Jeong, Mi-Suk;Jin, Gyoung-Ean;Jang, Se-Bok
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권4호
    • /
    • pp.574-580
    • /
    • 2007
  • Full-length chloride intracellular channel protein 1 (CLIC1) is a member of the family of proteins related to bovine chloride intracellular channel p64. Mutations in the SEDL gene cause spondyloepiphyseal dysplasia tarda (SEDT), a rare X-linked chondrodysplasia. The link between the intracellular chloride channels and SEDL is an important step toward understanding their functional interplay. In the present study, CLIC1 protein was subcloned into the pGEX-KG vector and overexpressed in XL-1 blue cells. We developed a large-scale expression system composed of glutathione S-transferase (GST) fused with a 240-amino-acid CLIC1 protein in Escherichia coli. The soluble CLIC1 protein was successfully purified to homogeneity, and its purity, identity, activity and conformation were determined using SDS-PAGE, MALDI-MS, biophotometer and circular dichroism spectroscopic studies. The binding of both CLIC1 and SEDL proteins in vitro was detected by BIAcore biosensor and fluorescence measurements.

Detection of Blood Agent Gas Using $SnO_2$ Thin Film Gas Sensor

  • Choi, Nak-Jin;Kwak, Jun-Hyuk;Lim, Yeon-Tae;Joo, Byung-Su;Lee, Duk-Dong;Bahn, Tae-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제20권E2호
    • /
    • pp.69-75
    • /
    • 2004
  • In this study, thin film gas sensor based on tin oxide was fabricated to examine its characteristics. Target gas is acetonitrile ($CH_3$CN) which is a blood simulant for the chemical warfare agent. Sensing materials are SnO$_2$ SnO$_2$/Pt, and Sn/Pt with thickness from 1000 to 3000 $\AA$. The sensor consists of a sensing electrode with inter-digit (IDT) type in front side and a heater in rear side. Resistance changes of sensing materials are monitored on real time basis using a data acquisition board with a 12-bit analog to digital converter. Sensitivities are measured at different operating temperatures also with different gas concentrations and film thickness. The high sensitivity is obtained for Sn (3000 $\AA$)/Pt (30 $\AA$) at 30$0^{\circ}C$ for 3 ppm. Response and recovery times were about 40 and 160 s, respectively. Repetition measurements showed very good results with $\pm$3% in full scale range.

소규모 사무실의 조명 색 변화에 따른 시각적 감지 및 무드 변화 분석 (Analysis on Visual Perception and Mood for Color of Light in a Small Office)

  • 강민혜;김수영
    • 설비공학논문집
    • /
    • 제23권4호
    • /
    • pp.287-296
    • /
    • 2011
  • This study examines the influences of correlated color temperature and illuminance on visual perception and temporary mood sensation in a small office. Field measurements and surveys were conducted in a full-scale mock-up model. Twenty subjects participated in the survey under six lighting conditions formed by three color temperature and two illuminance levels. Results indicate that 4000 K color temperature was effective to mitigate glare sensation from light source. Lamps with low color temperature such as 2700 K was not recommended for office lighting since they are likely to caused glare and visual discomfort. Preferred color temperature was 4000 K and 6500 K for 750 lx and 500 lx target illuminance respectively. The increase of illuminance was not an effective contributor to improve mood perception. The illuminance should be lower than 500 lx to achieve good mood, but the illuminance level in office space should be considered with visual performance simultaneously. This study suggests that fluorescent lighting fixtures with 4000 K lamps would be usefully used for office lighting since they formed friendly conditions for better visual performance.