• Title/Summary/Keyword: full ratio

Search Result 1,285, Processing Time 0.034 seconds

Estimation of Bearing Capacity for Open-Ended Pile Considering Soil Plugging (폐색정도를 고려한 개단말뚝의 지지력 산정)

  • 백규호
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.397-404
    • /
    • 2002
  • The bearing capacity of open-ended piles is affected by the degree of soil plugging, which is quantified by the IFR. There is not at present a design criterion for open-ended piles that explicitly considers the effect of IFR on pile load capacity In order to investigate this effect, model pile load tests using a calibration chamber were conducted on instrumented open-ended piles. The results of these tests show that the IFR increases with increasing relative density and increasing horizontal stress of soils. The unit base and shaft resistances decrease with increasing IFR. Based on the results of the model pile tests, new empirical relations for base load capacity and shaft load capacity of open-ended piles are proposed. In order to check the accuracy of predictions made with the proposed equations, the equations were applied to the full-scale pile load test preformed in this study, Based on the comparisons with the pile load test results, the proposed equations appear to produce satisfactory predictions.

  • PDF

Comparison Magnetization Losses of the multi-stacked YBCO Coated conductor and the BSCCO tapes (YBCO CC와 BSCCO Tape의 적층에 따른 자화손실 특성비교)

  • Lim Hyoungwoo;Lee Heejoon;Cha Gueesoo;Lee Ji-Kwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.13-16
    • /
    • 2005
  • Multi-stacked HTS tapes are needed to conduct large current in the power application. In this paper magnetization losses of the multi-stacked YBCO coated conductor and the BSCCO tape have been measured and compared. Magnetization losses of single tape, 2-stacked, 3-stacked and 4-stacked HTS tapes have been presented in this paper. Multi-stacked tapes have been fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various stacked of external magnetic field to consider the anisotropic characteristics of HTS tapes. Test results show that loss density per unit volume decreased for both YBCO coated conductors and BSCCO tapes when the stacking number of tapes is increased. As the external magnetic field decreased, the ratio of decrement has risen because the full penetration magnetic field(Bp) of the multi-stacked tape is larger than that of the single tape.

The Effects of Pressure and Specific Heat on the Performance of Thermal Mass Flowmeter (열량형 질량유량계에 대한 압력과 비열 영향)

  • Choi, Y. M,;Park, K. A.;Choi, H. M.;Lee, K. S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.109-113
    • /
    • 1999
  • Thermal mass flow meter (TMF) is used measuring the small mass flow rate of gases. Generally, flow rate measuring accuracy of TMF is $\pm2{\%}$ of full scale. TMF is manufactured for specified working pressure and specified working gas by customer. If it were applied for different working pressure and gases, flow rate measurement accuracy decreased dramatically. In this study, a TMF tested with three different gases and pressure range of 0.2 MPa to 1.0 MPa. Effect of specific heat cause to increase flow measurement error as much as ratio of specific heat compare with reference gas. Pressure change cause to increase flowrate measurement deviation about $-0.2{\%}$ as the working pressure decreased 0.1 MPa.

  • PDF

AEffects of Impeller Blade Thickness on Performance of a Turbo Blower (임펠러 블레이드 두께가 터보블로워 성능에 미치는 영향)

  • Park, Jun-Young;Park, Moo-Ryong;Hwang, Soon-Chan;Ahn, Kook-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.5-10
    • /
    • 2010
  • This study is concerned with effects of impeller blade thickness on performance of a turbo blower. This turbo blower is developed as an air supply system in 250 kW MCFC system. The turbo blower consists of an impeller, two vaneless diffusers, a vaned diffuser and a volute. The three dimensional, steady state numerical analysis is simultaneously conducted for the impeller, diffuser and volute to investigate the performance of total system. To consider the non-uniform condition in volute inlet due to volute tongue, full diffuser passages are included in the calculation. The results of numerical analysis are validated with experimental results of thin blade thickness. Total pressure ratio, efficiency, slip factor and blade loading are compared in two cases. The slip factor is different in two cases and the comparison of two cases shows a good performance in thin blade thickness in all aspects.

Adaptive Adjustment of Radiation Properties for Entire Range of Axial Ratio using a Parasitic Microstrip Polarizer

  • Yoo, Sungjun;Lee, Dongeun;Byun, Gangil;Choo, Hosung
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1250-1256
    • /
    • 2017
  • This paper proposes the design of microstrip patch antennas for dual-band polarization adjustment. The antenna has a multi-layer structure for dual-band operation, and each layer contains a resonating patch with surrounding strips separated into two parts. The antenna polarization is adjusted by varying the separated positions of the strips, while fixing other design parameters. To demonstrate the feasibility, an antenna sample with right-hand circular polarization is fabricated, and its antenna characteristics are measured in a full anechoic chamber. The operating principle of polarization adjustment in the dual frequency bands is also verified by observing near electromagnetic fields and the magnetic surface current density around the antenna.

A Study on Development 9f Rotary Valve for Performance Enhancement in SI Engine (스파크점화 기관의 성능향상을 위한 회전형 흡배기장치의 개발에 관한 연구)

  • 김치원;윤창식;김유식
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.11-20
    • /
    • 1995
  • In recent years, the study on the high efficiency of the internal combustion engine has been mainly proceeding. In this study, we developed rotary valve to achieve the improvement of volumetric efficiency and to be simple construction. And then made a comparative analysis between rotary and poppet valve. In this experiment, rotary valve enlarged the flow area of valve port to minimize the resistance of the fluid flow and to flow smoothly in intake and exhaust process. Indeed, valve timing was controlled properly lest positive pressure in exhaust process should affect intake process. Motoring and firing experiments were using engine speed and air-fuel ratio as the principle parameter and the full opening of throttle valve and minimum spark advance for best torque (MBT) as engine operating variables.

  • PDF

Fabrication of amorphous carbon thin film using laser ablation technique (레이저 층착법에 의한 비정질 탄소계 박막의 제작)

  • ;;;K. Oura
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.484-487
    • /
    • 2001
  • Amorphous carbon thin films were deposited using laser ablation technique on Si(100) substrates at different temperatures. In this study, effects of the substrate temperature on the properties of amorphous carbon films were systematically investigated. The surface morphologic and structural properties of the films were studied by scanning electron microscopy (SEM) and raman spectroscope, respectively. With increasing of the substrate temperature, the surface morphologies were changed singnificantly. Moreover the intensity ratio of D-band and G-band and the full width at half maximum of these bands were dependent on substrate temperatures.

  • PDF

EDISON CFD를 이용한 100 kW 수평축 조류발전 터빈 주위 유동 해석

  • O, Seung-Jin;Nam, Gwon-U
    • Proceeding of EDISON Challenge
    • /
    • 2016.11a
    • /
    • pp.15-18
    • /
    • 2016
  • 본 연구는 조류발전 터빈의 블레이드 형상 최적화 해석 시스템 개발에 대한 사전연구의 일환으로 EDISON CFD의 프로펠러 단독성능 S/W와 SNUFOAM ShipMesh Advanced 자동격자생성기를 이용하여 조류발전 터빈 주위 유동장에 대한 수치해석을 수행하였다. TSR 조건 변화에 따라 수치해석을 수행하고 이에 대한 power, total coefficient를 동일한 조건에서 수행된 실험결과와 비교 검증하여 해석자의 신뢰도를 확인하였다. 또한, 블레이드 전체를 모델링한 full body 해석과 하나의 블레이드만을 모델링한 single body 해석 결과를 비교하여 경제적이면서 정도 높은 터빈 성능해석 프로세스를 제안하였다. 조류발전 터빈의 TSR 조건 변화에 따라 낮은 TSR 조건에서는 국부적 와동발생에 의해 $C_P$가 감소하는 것을 확인하였고 설계 TSR에서 가장 좋은 효율을 보임을 확인하였다. 이를 통해 suction side의 압력 분포, 팁 와동의 강도 등 성능개선을 위한 주요한 설계변수를 식별하였다.

  • PDF

Design of Transformer Turn-ratio with the Considerations of Efficiency in Bidirectional DC-DC Converter for EDLC (슈퍼커패시터 충방전용 양방향 DC-DC 컨버터의 효율을 고려한 변압기 권선비 설계)

  • Kim, Hak-Soo;Jung, Jae-Hun;Nho, Eui-Cheol;Kim, In-Dong;Kim, Heung-Geun;Chun, Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.19-20
    • /
    • 2012
  • 본 논문은 마이크로그리드에서 에너지 저장 시스템으로 이용되는 슈퍼커패시터 충방전용 양방향 DC-DC 컨버터의 효율을 고려한 변압기 권선비 설계에 관한 것이다. 본 논문에서 다루고자 하는 시스템은 Dual Full-Bridge 방식의 양방향 DC-DC 컨버터이다. 슈퍼커패시터측의 방전 동작시 컨버터는 부스트 컨버터로 등가화 할 수 있다. 따라서 등가화한 부스트 컨버터에 대해 권선비를 달리하면서 동일한 출력 조건에서 스위치 손실을 계산하였으며, 이를 통하여 최소의 손실을 가지는 출력전압 즉, 권선비를 찾는 방법을 제안한다.

  • PDF

Development of 20 kA standard current transformer with an accuracy of 0.005 % and its application (0.005 %의 초정밀 20 kA 표준용 전류변성기의 개발 및 활용)

  • Kwon, Sung-Won;Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jeon-Hong;Lee, Sung-Ha;Song, Yang-Sup;Kim, Myung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.953-954
    • /
    • 2007
  • High accurate 20 kA, 6 kA and 2 kA standard current transformers(CTs) with a ratio error within 0.005 % at full rated current have been developed. The CTs are useful as the reference CT of the CT comparator system in the current range of 20 kA to 10 A CT.

  • PDF