강제 대류를 통한 열소산 구조물의 위상최적화 (Topological Optimization of Heat Dissipating Structure with Forced Convection)

  • 윤길호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.408-409
    • /
    • 2008
  • This paper presents a new development for topology optimization of heat-dissipating structure with forced convection. To cool down electric devices or machines, two types of convection models have been widely used: Natural convection model with a large Archimedes number and Forced convection with a small Archimedes number. Nowadays, many engineering application areas such as electrochemical conversion device or fuel cell devices adopt the forced convection to transfer generated heat. Therefore, to our knowledge, it becomes an important issue to design flow channels inside which generated heat transfer. Thus, this paper studies optimal topological designs considering fluid-heat interaction. To consider the effect of the advection in the heat transfer problem, the incompressible Navier-stokes equation is solved. This paper numerically studies the coupling phenomena and presents optimal channel design considering forced convection.

  • PDF

고등훈련기 전기체 정적시험을 위한 여압시험 (Pressurization Test for Full-scale Static Test of T-50 Aircraft)

  • 심재열;김태욱;송재창;황귀철;황인희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1384-1387
    • /
    • 2003
  • Pressurization test is usually required in aircraft full-scale static test. There are several test conditions including pressurization of cockpit, fuselage fuel tank, air inlet duct for T-50 full-scale static test. In this paper, the test conditions, equipment, piping analysis for the pressurization test are introduced. Tank simulation test is performed to verify the validity of piping analysis and to find good tuning parameters for the pressurization channel in the servo controller. Several test setup for pressurization of T-50 test is introduced. Test article volume is filled by form, $60%{\sim}80%$ volume is reduced for the T-50 full-scale static test. Pressurization system is connected to servo controller which also controls hydraulic actuator. Load and pressure control is synchronized by using the same servo controller during T-50 test. Typical control result for pressurization test condition is shown. Pressurization tests of T-50 full-scale static test was completed successfully.

  • PDF

AGING ASSESSMENT OF CANDU PLANT MAJOR COMPONENTS

  • Jeong, Il-Seok;Lee, Kyoung-Soo;Kim, Tae-Ryong
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2003년도 춘계 학술발표회 논문집
    • /
    • pp.415-423
    • /
    • 2003
  • Korea Electric Power Research Institute(KEPRI) had worked a comprehensive Plant Lifetime Management (PLiM) project for a CANDU plant in corporation with Korea Hydro and Nuclear Power(KHNP). The project had been performed to understand the aging status of major components screened from the plant and to address provisions for the continued operation over its design life. A feasibility of the continued operation was reviewed in the aspects of technology, economics, and regulatory environments. This paper introduces general approach of aging assessment, screening of critical components and an experience of aging assessment for an example of fuel channel that is the most critical component in CANDU plant.

  • PDF

Sticking and Desorption of Atomic Hydrogen on the Armchair Edges of Bilayer Graphene

  • Natividad, Michelle;Arboleda Jr., Nelson;Kasai, Hideaki
    • Journal of Electrochemical Science and Technology
    • /
    • 제7권3호
    • /
    • pp.185-189
    • /
    • 2016
  • The coupled channel method via the Local Reflection (LORE) matrix is employed to investigate the quantum mechanical behavior of the sticking or adsorption and desorption of hydrogen (H) atom on bilayer graphene via the armchair edge. The sticking and desorption probabilities of H are calculated and are plotted against the initial translational energy of H. The sticking probability plot shows a barrierless reaction indicating that hydrogen is easily adsorbed on the armchair edge of graphene. The desorption probability plot, however, shows that desorption of H from the graphene sheets is an activated process with a barrier height of 4.19 eV suggesting that a strong bond exists between the adsorbed H atom and the edge carbon atom. Thus, temperatures higher than the operating temperatures (300 - 1500 K) of conventional fuel cells are necessary to release the adsorbed H atom from the armchair edge of graphene.

고분자전해질형 연료전지의 공기 채널 내에서의 액적 거동에 대한 수치적 연구 (Numerical Study of Droplet Dynamics in a PEMFC Air Flow Channel)

  • 최지영;손기헌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2390-2395
    • /
    • 2008
  • The water droplet motion in an air flow microchannel with pores through which water emerges is studied numerically by solving the equations governing the conservation of mass and momentum. The gas-liquid interface is tracked by a level set method which is based on a sharp-interface representation for accurately imposing the matching conditions at the interface and is modified to implement the contact angle conditions on the wall and pores. The numerical results show that the droplet growth and detachment pattern depend significantly on the contact angle and inlet air velocity. Also, the dynamic interaction between the droplets growing on multiple pores is investigated. The pore arrangement subject to droplet merging is found to be not effective for water removal.

  • PDF

IT-SOFC의 전류밀도 및 온도분포에 관한 수치해석 연구 (A Numerical study on current density and temperature distributions of IT-SOFC)

  • 손상호;이규진;남진현;김찬중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3067-3072
    • /
    • 2008
  • A two-dimensional model for anode-supported IT-SOFCs is proposed in order to accurately consider the heat and mass transport processes with a fully-developed axial velocity profile in channel flow. A comprehensive micro model is employed to describe the electrochemical reaction in anode and cathode of SOFCs. This paper investigates the effects of operational parameters (inlet temperature, the amount of flow rate, and air flow rate) including flow configurations (co-flow and counter-flow) on the current density and temperature distributions in the IT-SOFCs.

  • PDF

Hot-Pressing Effects on Polymer Electrolyte Membrane Investigated by 2H NMR Spectroscopy

  • Lee, Sang Man;Han, Oc Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권2호
    • /
    • pp.510-514
    • /
    • 2013
  • The structural change of Nafion polymer electrolyte membrane (PEM) induced by hot-pressing, which is one of the representative procedures for preparing membrane-electrode-assembly for low temperature fuel cells, was investigated by $^2H$ nuclear magnetic resonance (NMR) spectroscopy. The hydrophilic channels were asymmetrically flattened and more aligned in the membrane plane than along the hot-pressing direction. The average O-$^2H$ director of $^2H_2O$ in polymer electrolyte membrane was employed to extract the structural information from the $^2H$ NMR peak splitting data. The dependence of $^2H$ NMR data on water contents was systematically analyzed for the first time. The approach presented here can be used to understand the chemicals' behavior in nano-spaces, especially those reshaping and functioning interactively with the chemicals in the wet and/or mixed state.

고분자 전해질 연료전지 가스확산층의 압축상태 평면 기체투과율 측정 (Measurement of In-plane Gas Permeability of Gas Diffusion Layers in Proton Exchange Membrane Fuel Cells under Compressive Strain)

  • 오창준;이용택
    • 설비공학논문집
    • /
    • 제28권9호
    • /
    • pp.367-372
    • /
    • 2016
  • Gas diffusion layer (GDL) of PEMFCs plays a role that it diffuses the reactant gases to the catalyst layer on the membrane and discharge water from the catalyst layer to the channel. Physical parameters related to the mass transport of GDL are mostly from the uncompressed GDLs while actual GDLs in the assembled stacks are compressed. In this study, the relation of compression and strain of GDLs with various Polytetrafluoroethylene (PTFE) loading is measured experimentally and In-plane gas permeability is measured at the condition that the GDLs are in compressive strain. The gas permeability decreased with the loading of PTFE and the presentation of gas permeability under compressive stain is expected to improve the accuracy of modeling work of mass transport in the GDL.

Wire-wrap Models for Subchannel Blockage Analysis

  • Ha K.S.;Jeong H.Y.;Chang W.P.;Kwon Y.M.;Lee Y.B.
    • Nuclear Engineering and Technology
    • /
    • 제36권2호
    • /
    • pp.165-174
    • /
    • 2004
  • The distributed resistance model has been recently implemented into the MATRA-LMR code in order to improve its prediction capability over the wire-wrap model for a flow blockage analysis in the LMR. The code capability has been investigated using experimental data observed in the FFM (Fuel Failure Mock-up)-2A and 5B for two typical flow conditions in a blocked channel. The predicted results by the MATRA-LMR with a distributed resistance model agreed well with the experimental data for wire-wrapped subchannels. However, it is suggested that the parameter n in the distributed resistance model needs to be calibrated accurately for a reasonable prediction of the temperature field under a low flow condition. Finally, the analyses of a blockage for the assembly of the KALIMER design are performed. Satisfactory results by the MATRA-LMR code were obtained through and rerified a comparison with results of the SABRE code.

Preliminary analysis and design of the heat exchangers for the Molten Salt Fast Reactor

  • Ronco, Andrea Di;Cammi, Antonio;Lorenzi, Stefano
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.51-58
    • /
    • 2020
  • Despite the recent growth of interest in molten salt reactor technology and the crucial role which heat transfer plays in the design of power reactors, specific studies on the design of heat exchangers for the Molten Salt Fast Reactor have not yet been performed. In this work we deliver a preliminary but quantitative analysis of the intermediate heat exchangers, based on reference design data from the SAMOFAR H2020-Euratom project. Two different promising reference technologies are selected for study thanks to their compactness features, the Printed Circuit and the Helical Coil heat exchangers. We present preliminary design results for each technology, based on simplified design tools. Results highlight the limiting effects of the compactness constraints imposed on the fuel salt inventory and the allowed size. Large pressure drops on both flow sides are to be expected, with negative consequences on pumping power and natural circulation capabilities. The small size required for the flow channels also represents possible fabrication issues and safety concerns regarding channel blockage.