• 제목/요약/키워드: front-end DC/DC converter

검색결과 49건 처리시간 0.029초

홀드 업 타임 보상회로를 가진 IT 기기용 Front-end PSFB DC/DC 컨버터 (Phase-Shifted Full Bridge(PSFB) DC/DC Converter with a Hold-up Time Compensation Circuit for Information Technology (IT) Devices)

  • 이강현
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.501-506
    • /
    • 2013
  • A hold-up time compensation circuit is proposed to get high efficiency of the front-end phase-shifted full bridge DC/DC converter. The proposed circuit can make the phase-shifted full bridge front-end DC/DC converter built with 0.5 duty ratio so that the conduction loss of the primary side and voltage stress across rectifier in the secondary side are reduced and the higher efficiency can be obtained. Furthermore, the requirement of an output filter significantly can diminish due to the perfect filtered waveform. A 12V/100A prototype has been made and experimental results are given to verify the theoretic analysis and detailed features.

고효율, 고전력밀도 아답터를 위한 도통밴드 제어 AC-DC 벅 컨버터 (A Conduction Band Control AC-DC Buck Converter for a High Efficiency and High Power Density Adapter)

  • 문상철;정봉근;구관본
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.38-39
    • /
    • 2017
  • This paper proposes a new control method for an AC-DC Buck converter which is utilized as a front-end converter of a 2-stage high power density adapter. In the conventional adapter applications, 2-stage configuration shows higher power transfer efficiency and higher power density than those of the single stage flyback converter. In the 2-stage AC-DC converter, the boost converter is widely used as a front-end converter. However, an efficiency variation between high AC line and low AC line is large. On the other hand, the proposed conduction band control method for a buck front-end converter has an advantage of small efficiency variation. In the proposed control method, switching operation is determined by a band control voltage which represents output load condition, and an AC line voltage. If the output load increasesin low AC line, the switching operation range is expanded in half of line cycle. On the contrary, in light load and high line condition, the switching operation is narrowed. Thus, the proposed control method reduces switching loss under high AC line and light load condition. A 60W prototype which is configured the buck and LLC converter with the proposed control method is experimented on to verify the validity of the proposed system. The prototype shows 92.16% of AC-DC overall efficiency and 20.19 W/in 3 of power density.

  • PDF

배전용 반도체 변압기 구현을 위한 SiC MOSFET 기반 전력변환회로 단위모듈 설계에 관한 연구 (Design and Implementation of a Power Conversion Module for Solid State Transformers using SiC MOSFET Devices)

  • 임정우;조영훈
    • 전력전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.109-117
    • /
    • 2017
  • This paper describes the design and implementation of a unit module for a 10 kVA class 13.2 kV/220 V unidirectional solid-state transformer (SST) with silicon-carbide metal-oxide-semiconductor field-effect transistors. The proposed module consists of an active-front-end (AFE) converter to interface 1320 V AC voltage source to 2500 V DC link and an isolated resonant DC-DC converter for 500 V low-voltage DC output. The design approaches of the AFE and the isolated resonant DC-DC converters are addressed. The control structures of the converters are described as well. The experiments for the converters are performed, and results verify that the proposed unit module can be successfully adopted for the entire SST operation.

Cascaded H-bridge Multilevel Inverter employing Front-end Flyback Converter with Single Independent DC Voltage Source

  • Kim, Ki-Du;Bae, Gyou-Tak;Kang, Feel-Soon
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권2호
    • /
    • pp.197-201
    • /
    • 2013
  • Cascaded H-bridge multilevel inverter requires independent DC voltage sources to produce multi output voltage levels. When it needs to generate more levels in the output voltage wave, the number of independent DC voltage sources usually limits its extension. To solve this problem, we propose a cascaded H-bridge multilevel inverter employing a front-end flyback converter for unifying input DC voltage sources. After theoretical analysis of the proposed circuit, we verify the validity of the proposed inverter using computer-aided simulations and experiments.

더블라인 주파수 제거를 위한 양방향 컨버터의 전력 디커플링 제어 (Power Decoupling Control of the Bidirectional Converter to Eliminate the Double Line Frequency Ripple)

  • Amin, Saghir;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.62-64
    • /
    • 2018
  • In two-stage single-phase inverters, inherent double line frequency component is present at both input and output of the front-end converter. Generally large electrolytic capacitors are required to eliminate the ripple. It is well known that the low frequency ripple shortens the lifespan of the capacitor hence the system reliability. However, the ripple can hardly be eliminated without the hardware combined with an energy storage device or a certain control algorithm. In this paper, a novel power-decoupling control method is proposed to eliminate the double line frequency ripple at the front-end converter of the DC/AC power conversion system. The proposed control algorithm is composed of two loop, ripple rejection loop and average voltage control loop and no extra hardware is required. In addition, it does not require any information from the phase-locked-loop (PLL) of the inverter and hence it is independent of the inverter control. In order to prove the validity and feasibility of the proposed algorithm a 5kW Dual Active Bridge DC/DC converter and a single-phase inverter are implemented, and experimental results are presented.

  • PDF

PI Controlled Active Front End Super-Lift Converter with Ripple Free DC Link for Three Phase Induction Motor Drives

  • Elangovan, P.;Mohanty, Nalin Kant
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.190-204
    • /
    • 2016
  • An active front end (AFE) is required for a three-phase induction motor (IM) fed by a voltage source inverter (VSI), because of the increasing need to derive quality current from the utility end without sacrificing the power factor (PF). This study investigates a proportional-plus-integral (PI) controller based AFE topology that uses a super-lift converter (SLC). The significance of the proposed SLC, which converts rectified AC supply to geometrically proceed ripple-free DC supply, is explained. Variations in several power quality parameters in the intended IM drive for 0% and 100% loading conditions are demonstrated. A simulation is conducted by using MATLAB/Simulink software, and a prototype is built with a field programmable gate array (FPGA) Spartan-6 processor. Simulation results are correlated with the experimental results obtained from a 0.5 HP IM drive prototype with speed feedback and a voltage/frequency (V/f) control strategy. The proposed AFE topology using SLC is suitable for three-phase IM drives, considering the supply end PF, the DC-link voltage and current, the total harmonic distortion (THD) in supply current, and the speed response of IM.

정전 용량형 SP4T RF MEMS 스위치 구동용 4채널 승압 DC-DC 컨버터 (Four Channel Step Up DC-DC Converter for Capacitive SP4T RF MEMS Switch Application)

  • 장연수;김현철;김수환;전국진
    • 대한전자공학회논문지SD
    • /
    • 제46권2호
    • /
    • pp.93-100
    • /
    • 2009
  • 본 논문에서는 전하 펌프(charge pimp) 방식의 전압 더블러(voltage doubler) 구조를 이용한 4채널 DC-DC 컨버터 개발을 소개한다. 무선 통신 트랜시버 내부에 위치하는 FEM(Front End Module)에서의 사용을 목표로 연구 개발 중인 정전 용량형 SP4T RF MEMS 스위치 구동용 DC-DC 컨버터를 개발하였다. 소비 전력이 적으며 작은 면적을 차지하는 전하 펌프 구조와 10MHz 스위칭 주파수를 이용하여 3.3V에서 $11.3{\pm}0.1V$, $12.4{\pm}0.1V$, $14.1{\pm}0.2V$로 승압한다. 전압 레벨 변환기(Voltage level shifter)를 이용하여 DC-DC 컨버터의 출력을 3.3V 신호로 선택적으로 온오프(on/off) 할 수 있으며 정전 용량형 MEMS 기기에 선택적으로 전달할 수 있도록 구현하였다. 칩 외부에 수동 소자를 추가하지 않고 칩 내부에 CMOS 공정 중에 제작된 저항과 커패시터만으로 원하는 출력을 낼 수 있도록 설계하였다. 전체 칩의 크기는 패드를 포함하여 $2.8{\times}2.1mm^2$이며 소비 전력은 7.52mW, 7.82mW, 8.61mW이다.

고속전철 4상한 입력 컨버터 병렬 운전에 관한 연구 (A Study on the Parallel Operation of a Front-end-converter for a High Speed Electric Traction Drive)

  • 류홍제;우명호;김종수;김원호;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.121-124
    • /
    • 1998
  • Front end AC to DC converters of the boost type are used in traction applications for generating the DC link for the inverters. A GTO based converter is usually switched with a switching frequency of 300 to 500Hz, resulting in low frequency harmonic problems. In order to avoid this, multiple converters with Phase shifted carrier waveforms are used to suppress the low frequency harmonics. A detailed study of an AC to DC converter, with two converters parallely operated with Phase shifted carrier wave farms is Presented in this paper.

  • PDF

병렬 Differential Power Processing 컨버터의 비교 분석 (Comparison of Two Parallel Differential Power Processing Configurations)

  • 이현지;김예린
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.48-49
    • /
    • 2017
  • 태양광 발전 시스템 구현에 있어 가장 큰 문제점 중 하나는 불균일한 태양빛 조건에서의 전체 시스템 발전량 감소이다. 이를 해결하기 위해 module-integrated converter (MIC), dc optimizer, differential power processing (DPP) 등 다양한 컨버터가 연구되고 있다. 그 중에서도 DPP 컨버터는 낮은 전력변환 손실로 높은 시스템 효율을 얻을 수 있어 최근 많은 주목을 받고 있다. 보통 그리드 연결형 태양광발전 시스템에 적용되는 직렬 DPP의 경우, 이미 많은 연구가 진행되고 있지만, 병렬 DPP의 경우 아직 많은 연구가 필요한 상황이다. 본 논문에서는 front-end 컨버터의 존재 유무에 따른 두 가지 병렬 DPP 컨버터 배열을 비교 분석 하였다. Front-end 컨버터가 적용된 병렬 DPP 컨버터 배열의 경우, dc 전압과 태양전지의 전압 차이를 최소화해 전력 변환 손실을 감소시킬 수 있지만, front-end 컨버터에서 추가적인 전력 변환 손실이 발생한다. Front-end 컨버터가 없는 경우, dc 전압과 태양전지의 전압차이가 커 DPP 컨버터에서 발생하는 전력 변환 손실이 커진다. 따라서 주어진 조건 아래 효율적인 병렬 DPP 컨버터 디자인을 위한 가이드라인을 본 논문에서 제시하고자 한다.

  • PDF

동기 정류기를 이용한 고효율 역률보상형 AC/DC 컨버터 (High Efficiency PFC AC/DC Converter with Synchronous Rectifier)

  • 박한웅
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.266-269
    • /
    • 2000
  • This paper presents a novel single-stage unity power factor converter which features the reduced switching losses by zero-voltage switching and zero-current switching (ZVZCS). Hence the turn-on and turn-off losses of switches are sufficiently reduced. And the reduced conduction losses are achieved by the elimination of one leg of front-end rectifier. And low on-resistance MOSFETs (Synchronous Rectifier) are used in the rectifier at the secondary side of high frequency transformer instead of diodes. Theoretical analysis simulated results of a AC to DC 150W(5V, 30A) converter are presented.

  • PDF