• 제목/요약/키워드: fresh and hardened concrete property

검색결과 23건 처리시간 0.027초

콘크리트용 부순 굵은 골재의 입형이 콘크리트의 물리적 성질에 미치는 영향에 관한 연구 (A study on the Effect of Aggregate Particle Shape on Property of Concrete)

  • 서기원;이욱재;김학연;김남호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.209-212
    • /
    • 2004
  • Recent economic development caused a vast use of mineral resources in Korea. Consequently, a supply of poor quality course aggregate (poor particle shape as well as poor gradation) in construction material become a social problem. In this study, an effect of aggregate particle shape on property of concrete was evaluated. The flat and elongation ratio of crushed aggregate was controled to 8, 15, 25, 35, and $47\%$ in order to evaluate fresh concrete behavior as well as physical properties in hardened concrete. Test result shows a poor aggregate particle shape cause a significant increase in entrapped air in fresh concrete, while no significant effect on hardened concrete property, such as strength as well as stiffness. This increase in entrapped air, however, believed to cause a significant decrease in concrete durability.

  • PDF

혼화재 및 혼화제의 조절에 의한 서중 콘크리트의 효과적 관리 (The Effective Control of Hot Weather Concreting by Optimum Mineral and Chemical Admixtures)

  • 이동율;함수윤;오태근
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.59-66
    • /
    • 2015
  • 본 연구는 슬럼프 감소, 연행 공기 부족, 건조수축 균열, 강도감소 등 굳지 않은 콘크리트와 굳은 콘크리트의 성질에 대한 타설시 고온의 악영향에 대한 원인분석을 실시하고 이를 경감시키기 위한 감수제, 공기연행제, 지연제 등의 화학적 혼화제와 플라이 애쉬, 고로 슬래그 등의 무기질 혼화재의 다양한 적용이 검토되었다. 즉, 서중 콘크리트의 품질향상을 위한 다양한 콘크리트 배합이 설계되고 각 배합에서의 굳지 않은 콘크리트 및 굳은 콘크리트 에 대한 영향이 분석되고 몇 가지의 최적 배합이 도출되었다.

EEZ모래와 부순모래를 사용한 레미콘의 굳지않은 성상 및 경화성상에 관한 연구 (An Experimental Study on the Properties of Fresh and Hardened Ready Mixed Concrete Using EEZ sand and Crush sand)

  • 신승봉;구경모;나철성;유재철;김규용;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.53-56
    • /
    • 2006
  • Recently, trouble of sand supplying is occurred according to exhaustion of natural sand resources. Therefore various measures are proposed for solution of trouble of sand supply and crushed sand among measures is used as one of most universal measures. But because crushed sand have poor particle shape and plenty of makes micro particle, the quality of concrete using crushed sand deteriorated. Therefore, this study evaluated engineering property of concrete with replacement ratio of crushed sand and EEZ sand and applied evaluation result to fundamental data for quality control of concrete using crushed sand and EEZ sand. The result of this study have shown that quality of concrete using crushed sand and EEZ sand and The compressive strength of concrete up to 50, 70% EEZ sand replacement by crush sand, nearly equal to that of general sand.

  • PDF

Effect of presoaking degree of lightweight aggregate on the properties of lightweight aggregate concrete

  • Tang, Chao-Wei
    • Computers and Concrete
    • /
    • 제19권1호
    • /
    • pp.69-78
    • /
    • 2017
  • This study aimed at exploring the effect of presoaking degree of lightweight aggregate (LWA) on the fresh and hardened properties of concrete. Two series (i.e., Series A and Series B) of concrete mixes that were made of LWA with different moisture states were prepared. The presoaking degree of LWA was divided into three types: oven dry state, 1 hour prewetted and 24 hours prewetted. For the Series A, the water content of the lightweight aggregate concrete (LWAC) mixes was adjusted in accordance with the moisture condition of the LWA. Whereas the amount of water added in the Series B mixes was deliberately not adjusted for the moisture condition of the LWA. Slump test, mechanical tests, interfacial transition zone microscopical tests and thermal conductivity test were carried out on the specimens of different concretes and compared with control normal-weight aggregate concretes. The test results showed that the effect of mixing water absorption by LWA with different moisture states was reflected in the fresh concrete as the loss of mixture workability, while in the hardened concrete as the increase of its strength. With the use of oven-dried LWA, the effect of reduction of water-cement ratio was more significant, and thus the microstructure of the ITZ was more compact.

코팅 경량골재를 활용한 경량골재 콘크리트의 물리적 특성 연구 (Study on Mechanical property of lightweight aggregate concrete with coated-lightweight aggregate)

  • 김세환;김상헌;서치호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.87-88
    • /
    • 2011
  • High absorptance of lightweight aggregate make a hard product, work, quality management ect. for making low absorptance property, lightweight aggregate is coated by an organic matter and that way remarkably showed to decrease the absorptance by pre-study. but first, we would need a check to fit into the concrete which both fresh concrete and hardened concrete. In this study, mechanical property change of coated lightweight aggregate concrete was analysed by compared experiment with coated lightweight aggregate concrete and non-coated aggregate concrete.

  • PDF

구조용 경량골재 개발에 따른 경량콘크리트의 동결융해특성에 관한 연구 (Property Evaluation of the Freeze-Thawing for Lightweight Concrete with Development of Structural Lightweight Aggregates)

  • 장동일;채원규;조광현;김광일;손영현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회 논문집(I)
    • /
    • pp.129-136
    • /
    • 1998
  • In this study, lightweight aggregates were developed to see the possible application as a structural uses. For the evaluation purpose, several testings were conducted to compare the physical characteristics between the controlled lightweight aggregates and other lightweight aggregates purchased from different sources. The tests included property changes of fresh concrete and strength characteristics of hardened concrete for both normal and high strength ranges. In addition, a experiment was performed to analyze the freezing and thawing resistance of new lightweight aggregate concrete against other lightweight aggregate concrete against other lightweight aggregate concretes with some experimental parameters such as lightweight aggregates, curing conditions, and water-cement ratio. The test showed that the new lightweight aggregate could be used structural components. Continuous study will be planned for future evaluations.

  • PDF

폴리사카라이드계 증점제를 혼합한 고유동 콘크리트의 물성 (Properties of Self Compacting Concrete Using Viscosity Agent Based on Polysaccharide Derivative)

  • 최재진;유정훈;신도철;나종율
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.45-48
    • /
    • 2005
  • Self compacting concrete has the strong point in capability of concrete to be uniformly filled and compacted in every corners of formwork by its self-weight without vibration during placing. However, powder type self compacting concrete has the weak point in the heat of hydration, the drying shrinkage and the elastic property of concrete etc. Recently viscosity agent has been developed in order to overcome these weaknesses. In this study, self compacting concrete is made with viscosity agent based on polysaccharide derivative in order to develope the normal strength self compacting concrete. Slump flow, loss of slump flow and setting time are measured for comparison with normal concrete. Compressive strength, freezing and thawing test and carbonation test are conducted on normal and self compacting concrete using viscosity agent. In the experiment, we acquired good results in fresh and hardened self compacting concrete using viscosity agent based on polysaccharide derivative.

  • PDF

개질처리한 제강슬래그 잔골재 사용 콘크리트의 성질 (A Fundamental Property of Concrete Containing Atomized Steel Slag Fine Aggregate after Reforming Process)

  • 문한영;유정훈;박영훈;김주용;윤표호;김얼
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.318-321
    • /
    • 2003
  • Steel slag is produced during steel making process. Compared with the blast furnace slag, converter slag has the expansibility due to the reaction with water and free CaO. Therefore it is specified in Standard Specification for Concrete in Korea that steel slag aggregate must not be used in concrete. In this study, atomized steel slag aggregate is conducted from converter slag by the atomizing method. Atomized steel slag and conventional converter slag are same in its composite by nature in the converter but compounds of the composite become different because of different method of slag treatment. Especially atomized steel slag aggregate overcomes expansibility that is the weak point for usage. It is researched whether it has the possibility, suitability for fine aggregate in concrete. Slump and air content are measured in fresh concrete, compressive and bending strength in hardened concrete. These is compared with control concrete with washed sand.

  • PDF

고강도 경량 자기충전콘크리트의 성능평가 (Properties of High Strength Lightweight Self-Compacting Concrete)

  • 최연왕;문대중;안성일;최욱;조선규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.413-416
    • /
    • 2003
  • Experimental tests on the high strength self-compacting concrete with light-weight fine aggregate and light-weight coarse aggregate(LHSSC) were performed with slump-flow, reaching time to the slump-flow of 500mm, V-funnel dropping time and U-box difference level and compressive strength. LHSCC with light-weight fine aggregate of 75% and light-weight coarse aggregate of 100% was only satisfied with the property conditions of second self-compacting concrete(SCC), like as flowability, resistance to segregation and filling ability. The 28-day compressive strength of LHSCC indicated above 300kgf/$\textrm{cm}^2$ in all concrete mixtures, and it was increased to increase the replacement ratio of light-weight fine aggregate or to decrease the replacement ratio of light-weight coarse aggregate. Therefore, for satisfying the properties of fresh SCC and hardened concrete with above 350kgf/$\textrm{cm}^2$, it would expected that the replacement ratio of light-weight fine aggregate and light-weight coarse aggregate will be determined with 50~75% and 25~50%, respectively.

  • PDF

섬유종류 및 마감방법에 따른 무근콘크리트의 균열제어 방법 (The Control Methods of Crack on Concrete with Fiber reinforced and Finishing)

  • 이태규;김규용;강연우;김순묵;김수봉;정재영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.260-261
    • /
    • 2014
  • When press concrete with high W/B was hardened, it should consider a crack to make stress by drying shrinkage. For control of crack, wire-mesh used to reinforce concrete in site. Actually, it reported failure case in lack of quality control. This study conducted experiment to apply fiber reinforced press concrete. it was evaluated on fresh property, compressive strength and shrinkage crack of press concrete with fiber.

  • PDF