• Title/Summary/Keyword: frequency-response

Search Result 5,570, Processing Time 0.039 seconds

Design of a New VSS-Adaptive Filter for a Potential Application of Active Noise Control to Intake System (흡기계 능동소음제어를 위한 적응형 필터 알고리즘의 개발)

  • Kim, Eui-Youl;Kim, Byung-Hyun;Kim, Ho-Wuk;Lee, Sang-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.2
    • /
    • pp.146-155
    • /
    • 2012
  • The filtered-x LMS(FX-LMS) algorithm has been applied to the active noise control(ANC) system in an acoustic duct. This algorithm is designed based on the FIR(finite impulse response) filter, but it has a slow convergence problem because of a large number of zero coefficients. In order to improve the convergence performance, the step size of the LMS algorithm was modified from fixed to variable. However, this algorithm is still not suitable for the ANC system of a short acoustic duct since the reference signal is affected by the backward acoustic wave propagated from a secondary source. Therefore, the recursive filtered-u LMS algorithm(FU-LMS) based on infinite impulse response(IIR) is developed by considering the backward acoustic propagation. This algorithm, unfortunately, generally has a stability problem. The stability problem was improved by using an error smoothing filter. In this paper, the recursive LMS algorithm with variable step size and smoothing error filter is designed. This recursive LMS algorithm, called FU-VSSLMS algorithm, uses an IIR filter. With fast convergence and good stability, this algorithm is suitable for the ANC system in a short acoustic duct such as the intake system of an automotive. This algorithm is applied to the ANC system of a short acoustic duct. The disturbance signals used as primary noise source are a sinusoidal signal embedded in white noise and the chirp signal of which the instantaneous frequency is variable. Test results demonstrate that the FU-VSSLMS algorithm has superior convergence performance to the FX-LMS algorithm and FX-LMS algorithm. It is successfully applied to the ANC system in a short duct.

An implementation of NDIR type $CO_2$ gas sample chamber and measuring hardware for capnograph system in consideration of the time response characteristics (시간응답특성을 고려한 2광원 1센서 방식의 capnograph 시스템용 NDIR식 $CO_2$ 가스 챔버 설계 및 측정 회로의 구현)

  • Park, I.Y.;Lee, I.K.;Lee, S.K.;Kang, K.M.;Kang, S.W.;Cho, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.279-285
    • /
    • 2001
  • The capnograph system for determining the partial pressure of carbon dioxide in the blood of a patient was developed based on the NDIR(non-dispersive infrared) absorption technology. NDIR gas analyzing method requires an optical absorption chamber and signal processing hardware. In this paper, we have designed and implemented NDIR type $CO_2$ gas chamber in consideration of the time response characteristics and lamp chopping frequency. And we have implemented signal processing hardware using two infrared sources to reduce the thermal background effect. The implemented gas chamber and signal processing hardware were tested in the temperature variation experiment and human expiratory experiment. The results showed that the system could produce a stable output signal and a good $CO_2$ gas concentration curve like a typical capnogram.

  • PDF

Modeling and CAE Simulation of Chassis Driveline Test Bench for Vehicle NVH Improvement (차량 NVH개선 설계를 위한 샤시 구동계의 Driveline Test Bench 구성 및 CAE 해석)

  • Kim, Kee-Joo;Ju, Hyung-Jun;Lee, Yong-Heon;Bae, Dae-Sung;Sung, Chang-Won;Baik, Young-Nam;Sohn, Il-Seon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.1
    • /
    • pp.114-119
    • /
    • 2009
  • The authors have investigated the NVH problems of drive system in full vehicle test. However it is difficult to define the NVH problems of driveline system. Since it is hard to measure the rotating part and it is vague that only the drive system induces the NVH problem. Vibration in a driveline is presented in this paper. In the experiment, the rear sub-frame and propeller shafts and axle were composed and mounted with rubber each other. For applying the vibration input instead of the torsional vibration effect of an engine, the shaker was taken. In particular, torsional vibration due to fluctuating forced vibration excitation across the joint between driveline and rear sub-frame was carefully examined. Accordingly, the joint response was checked from experiments and the FE-simulation using FRF (frequency response function) analysis was performed. All test results were signal processed and validated against numerical simulations. In present study, the new test bench for measuring the vibration signal and simulating the vehicle chassis system was proposed. The modal value and the mode shape of components were analyzed using the CAE model to identify the important components affecting driveline noise and vibration. It could be reached that the simplified test bench could be well established and be used for design guide and development of the vehicle chassis components.

Electroacupuncture of $GB_{43}$ Modulates Neuronal Activities in Medial Vestibular Nuclei of Rats (협계(俠谿)에 대한 전침자극이 흰쥐의 내측 전정신경핵 자발활동성에 미치는 효과)

  • Kim, Jae-Hyo;Park, Byung-Rim;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.25 no.3
    • /
    • pp.117-135
    • /
    • 2008
  • Objectives: It is known that the vestibular imbalance leads to vestibular symptoms such as nausea, vomiting, vertigo and postural disturbance. Since the non-labyrinthine inputs from the limbs and viscera converge on the vestibular nucleus neurons receiving signal from peripheral vestibular endorgan, acupuncture to the periphery may influence the activities of vestibular nuclear neurons and produce a therapeutic effect on the vestibulacr symptoms. The present study was to examine a modification and characteristics of the static and dynamic activities of medial vestibular nucleus (MVN) neurons following electroacupuncture (EA) of GB43' acupoint. Methods: In 54 Sprague-Dawley adult male rats weighing 250${\sim}$300g, spontaneous firing discharges and dynamic responses induced by sinusoidal whole body rotation about vertical axis at 0.2 Hz were observed in MVN of rats during EA of GB43' acupoint, located between the left 4th and 5th toe, which is the territory of sural and peroneal nerves, with 0.2 ms, 40 Hz and 600${\pm}$200 ${\mu}A$. Results: EA of the left GB43' acupoint induced modifications of spontaneous firing rates in 45% of MVN neurons recorded, and the percentage of modified neurons was 44% in type I, 52% in type II and 46% in non-type neurons. The excitatory or inhibitory responses of spontaneous firing discharges were predominant in the ipsilateral MVN neurons during EA. The excitatory response was abolished after EA but the inhibitory response was prolonged after EA in the ipsilateral MVN. The neurons of MVN showing modified spontaneous firing discharges by EA showed lower frequency (${\geq}$10 spikes/sec) of mean spontaneous firing rates than non affected ones. Conclusion: These results suggest that the neuronal activities of MVN neurons were influenced by EA of GB43' acupoint and the effects of EA may be related to the convergence of the peripheral vestibular inputs and ascending somatosensory inputs on MVN.

  • PDF

Fatigue crack effect on magnetic flux leakage for A283 grade C steel

  • Ahmad, M.I.M.;Arifin, A.;Abdullah, S.;Jusoh, W.Z.W.;Singh, S.S.K.
    • Steel and Composite Structures
    • /
    • v.19 no.6
    • /
    • pp.1549-1560
    • /
    • 2015
  • This paper presents the characterization of fatigue crack in the A283 Grade C steel using the MMM method by identifying the effects of magnetic flux leakage towards the crack growth rate, da/dN, and crack length. The previous and current research on the relation between MMM parameters and fatigue crack effect is still unclear and requires specific analysis to validate that. This method is considered to be a passive magnetic method among other Non-Destructive Testing (NDT) methods. The tension-tension fatigue test was conducted with a testing frequency of 10 Hz with 4 kN loaded, meanwhile the MMM response signals were captured using a MMM instrument. A correlation between the crack growth rate and magnetic flux leakage produces a sigmoid shape curve with a constant values which present the gradient, m value is in the ranges of 1.4357 to 4.0506, and the y-intercept, log C in the ranges of $4{\times}10^{-7}$ to 0.0303. Moreover, a linear relation was obtained between the crack length and magnetic flux leakage which present the R-Squared values is at 0.830 to 0.978. Therefore, MMM method has their own capability to investigate and characterize the fatigue crack effects as a main source of fracture mechanism for ferrous-based materials.

Comparative Study on Wave Induced Fatigue Analysis Methods for Steel Catenary Riser (파랑하중에 의한 Steel Catenary Riser 피로손상 평가 방법의 비교검토)

  • Lee, Jeong-Dae;Lee, Sung-Je;Jang, Chang-Hwan;Jun, Seock-Hee;Oh, Yeong-Tae
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.3
    • /
    • pp.222-235
    • /
    • 2015
  • The purpose of this study is to suggest guidelines for riser fatigue analysis in terms of selection of reasonable analysis method. Three analysis methods (spectral, regular wave, rain-flow counting) are introduced and compared. As the riser systems give non-linear response, the time-domain analysis method is more preferred than frequency-domain analysis method. The spectral fatigue analysis method, however, is still useful for identifying fatigue prone areas. Once stress RAO is established, fatigue damage can be calculated very quickly. The regular wave method and the rain-flow counting method are more time consuming but give more exact results compare to spectral method. In case of regular wave method, a set of regular waves which represent random sea states is considered for dynamic analysis. The rain-flow counting method is the most intuitive and exact method because it refers time history stresses containing most of non-linear effects of the riser system. However, it is not common for early design stage to use rain-flow counting method because of its high cost. In this study, it was confirmed that the regular wave method is the most cost effective way in specific cases. However, if the system is highly non-linear, it seems that the regular wave method gives less accurate results than rain-flow counting method. Therefore, it is imperative that the engineers select appropriate analysis method based on design stage and given engineering period. This paper also discusses the theoretical background of each calculation method and hydrodynamic aspects of marine riser systems. A steel catenary riser (SCR) line on FPSO was considered and marine dynamic program (OrcaFlex) was used for static and dynamic analysis.

Basic Studies for the Development of the $NO_2$ Gas Sensor Using Functional Organic Ultrathin Film (기능성 유기 초박막을 이용한 $NO_2$ 가스센서 개발을 위한 기초 연구)

  • Sohn, B.C.;Rim, B.O.;Kim, Y.I.;Sohn, T.W.;Shin, D.M.;Ju, J.B.;Chung, G.Y.;Kim, Y.K.;Kang, W.H.;Lee, B.H.
    • Journal of the Korean Applied Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.125-131
    • /
    • 1995
  • Ultra thin films of Tetra-3-hexadecylsulphamoylcopperphthalocyanine(HDSM-CuPc) were formed on various substrates by Langmuir-Blodgett method, where HDSM-CuPc was synthesized by attaching long-chain alkylamine(hexa-decylamine) to CuPc. The reaction product was identified with FT-IR, UV-visible absorption spectroscopies, elemental analysis and thin layer chromatography. The formation of Ultrathin Langmuir-Blodgett(LB) films of HDSM-CuPc was confirmed by FT-IR and UV-visible spectroscopies. A quartz piezoelectric crystal coated with LB films of HDSM-CuPc was examined as a gas sensor for $N0_2$ gas. HDSM-CuPc LB films were transferred to a quartz crystal microbalance(QCM) in the form of Z-type multilayers. Response characteristics of film-coated QCM to $NO_2$ gas concentrations over a range of $100{\sim}600ppm$ have been tested with a thickness of $5{\sim}20$ layers of HDSM-CuPc. Changes in frequency by adsorption of $NO_2$ were increased With the number of LB layers and $NO_2$ concentration, but the response time was slow.

Seismic Response Control of Adjacent Structures by Semi-Active Fuzzy Control of Magneto-Rheological Damper (MR 감쇠기의 준능동 퍼지제어기법을 이용한 인접구조물의 지진응답제어)

  • Kim, Min-Seob;Ok, Seung-Yong;Park, Kwan-Soon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.39-50
    • /
    • 2009
  • In this paper, a method for reducing seismic responses of adjacent buildings is studied that involves connecting two buildings with energy-dissipating devices, such as MR dampers. For the vibration control of the adjacent buildings, a fuzzy control technique with semi-active MR dampers is proposed. A fuzzy controller, which can appropriately modulate the damping forces by controlling the input voltage in real time, is designed according to the proposed method. To verify the validity of the proposed method, numerical simulations are performed. In the numerical simulations, historical earthquake records with diverse frequency contents and different peak values are used. For the purpose of comparison, an uncontrolled system, a passive control system and a semi-active fuzzy control system are considered. The comparative results prove the effectiveness of the proposed control technique, i.e. the numerical results show that the fuzzy controlled semi-active MR dampers can effectively reduce the earthquake responses of the adjacent structures.

Effectiveness of Nursing Interviews on Initial Contacts with In- patients (입원시 정보수집을 위한 간호면담 방법의 효과에 대한 연구)

  • 이평숙
    • Journal of Korean Academy of Nursing
    • /
    • v.7 no.1
    • /
    • pp.88-98
    • /
    • 1977
  • This study was designed to identify a more effective method of nursing interview in gathering informations by comparing the two, the structured and unstructured methods. May through October, 1976, 40patients on psychiatric wards of Korea University Hospital and National Mental Hospital, Seoul, were sampled and interviewed on their admission/within one week of admission. Both methods were used simultaneously by different interviewers ; 48 hour interval were kept between the two approaches of interview. Contents of informations gathered were grouped according to the criteria developed by the researcher, frequency, percentile score and the means were scored, and the two methods were compared; the amount of information gathered, number of questions used, time spent and the general response towards the methodologies. Results of the study are summarized as follows ; 1. 1. 5 times as many informations were gathered through the structured interview. (1366 ; 849) 2. 68.32% of informations gathered through the unstructured interview and 42.46% of the structured interview revealed to be overlapping; through structured interview, more unique informations (57.54%) were gathered. 3. The average of 33.25 minutes were consumed for the structured interview while 95, 50 minutes for the unstructured. Much higher time consumption is revealed in the unstructured. 4. Majority of patients showed positive response towards both approaches of interview (90% each), however, interviewers responded to experience of certain degree of tension (stress) in the unstructured method (35%) 5. The average of 0.88 question were used to gather one information in the structured while 1.87questions for the unstructctured were used. 6. The average of 0.97 minutes were consumed to gather one information in the structured while 4.50minutes for the unstructured. 7. The average of 1.11 minutes were consumed for one question for the structured while 2.41 minutes for the unstructured. The results of the study revealed that the structured interview were more effective in gathering informations; a larger quantity of informations were gathered in shorter time. Recommendations for further in investigations are as follows ; 1. Comparative analysis of informations gathered through the two methods by experienced professional nurse- interviewers is recommended. 2. Comparative analysis of the quality of informations is recommended. 3. Comparative analysis of the interviewing process (interactions) in relation to the characteristics of patients'health problems is recommended.

  • PDF

Estimation of Effect Zone for the Establishment of Damage-Minimizing Plan of Chemical Plants (화학공장의 사고피해 최소화 대책수립을 위한 영향범위 평가)

  • Lee, Hern-Chang;Han, Seong-Hwan;Cho, Ji-Hoon;Shin, Dong-Il;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.69-74
    • /
    • 2011
  • As a way to propose a method for the establishment of practical damage-minimizing plan for chemical plants, the release scenario was established by using API-581 BRD and the effect zone was estimated by the KS-RBI program supporting the quantitative cause analysis. And the risk assessment was performed. As a result, we found that to minimize the damage of a chemical plant, it is effective to use four release hole diameters (small, medium, large and rupture) and release time estimated according to the classes of detection and isolation systems. In addition, it can be safely said that through appling the damage areas considering weighted average by failure frequency and worst-case simultaneously, industrial sites can come up with the effective emergency response plan.