DOI QR코드

DOI QR Code

Seismic Response Control of Adjacent Structures by Semi-Active Fuzzy Control of Magneto-Rheological Damper

MR 감쇠기의 준능동 퍼지제어기법을 이용한 인접구조물의 지진응답제어

  • 김민섭 (동국대학교 건축공학과) ;
  • 옥승용 (서울대학교 교량설계핵심기술연구단) ;
  • 박관순 (동국대학교 건축공학과)
  • Published : 2009.06.30

Abstract

In this paper, a method for reducing seismic responses of adjacent buildings is studied that involves connecting two buildings with energy-dissipating devices, such as MR dampers. For the vibration control of the adjacent buildings, a fuzzy control technique with semi-active MR dampers is proposed. A fuzzy controller, which can appropriately modulate the damping forces by controlling the input voltage in real time, is designed according to the proposed method. To verify the validity of the proposed method, numerical simulations are performed. In the numerical simulations, historical earthquake records with diverse frequency contents and different peak values are used. For the purpose of comparison, an uncontrolled system, a passive control system and a semi-active fuzzy control system are considered. The comparative results prove the effectiveness of the proposed control technique, i.e. the numerical results show that the fuzzy controlled semi-active MR dampers can effectively reduce the earthquake responses of the adjacent structures.

인접건물 사이에 감쇠기 형태의 에너지 소산장치를 설치하고 연결함으로써, 지진 응답을 줄이고 내진 성능을 향상시킬 수 있는 방법에 대하여 연구를 수행하였다. 서로 인접한 건물 간의 진동제어를 위하여 준능동 MR 감쇠기를 이용하는 퍼지 제어기법을 제시하고, MR 감쇠기의 감쇠력 조절을 시간에 따라 제어할 수 있도록 제시한 방법으로 제어기를 설계하였다. 제시한 방법의 타당성을 검증하기 위하여 수치모사를 수행하였으며, 다양한 역사지진의 지진응답 해석을 통해서 비제어시, 수동제어 및 준능동 퍼지제어 등에 대한 최대응답을 비교 분석하였다. 수치모사 결과 제시한 방법은, 다양한 주파수 성분을 가진 여러 가지 지진에 대해 매우 효과적인 제진 성능을 보이는 것으로 나타났다.

Keywords

References

  1. Christenson, R.E., Spencer, Jr. B.F. and Johnson, E.A., “Coupled building control using active and smart damping strategies,” Proceedings of the 5th International Conference on Application of Artificial Intelligence to Civil and Structural Engineering, Oxford, England, September 1999
  2. Ni, Y.Q., Ko, J.M. and Ying, Z.G., “Random seismic response analysis of adjacent buildings coupled with non-linear hysteretic dampers,” Journal of Sound and Vibration, Vol. 246, No. 3, 403-417, 2001 https://doi.org/10.1006/jsvi.2001.3679
  3. Bhaskararao, A.V. and Jangid, R.S., “Harmonic response of adjacent structures connected with a friction damper,” Journal of Sound and Vibration, Vol. 292, 710-725, 2006 https://doi.org/10.1016/j.jsv.2005.08.029
  4. 옥승용, 박관순, 고현무, “인접구조물의 진동제어를 위한 선형 감쇠시스템의 최적설계,” 한국지진공학회 논문집, 제 10권, 제 3호, 85-100, 2006 https://doi.org/10.5000/EESK.2006.10.3.085
  5. 옥승용, 김동석, 박관순, 고현무, “선형 점성 감쇠기가 장착된 인접구조물의 진동제어를 위한 유전자 알고리즘 기반 최적설계,” 한국지진공학회 논문집, 제 11권, 제 1호, 11-21, 2007. https://doi.org/10.5000/EESK.2007.11.1.011
  6. Basili, M. and De Angelis, M., “A reduced order model for optimal design of 2-mdof adjacent structures connected by hysteretic dampers,” Journal of Sound and Vibration 306, 297–317, 2007 https://doi.org/10.1016/j.jsv.2007.05.012
  7. 성은희, “인접 구조물간의 진동제어를 위한 복합제어시스템의 최적설계,” 석사학위, 동국대학교, 2008
  8. Spencer, Jr. B.F., Carlson, J.D., Sain, M.K., and Yang, G., “On the current status of magnetorheological dampers: seismic protection of full-scale structures,” Proceedings of 1997 American Control Conference, Albuquerque, NM, 458-462, 1997
  9. 박관순, 고현무, 옥승용, 서충원, “MR Damper가 장착된 교량 구조물의 준능동 퍼지제어,” 대한토목학회 논문집, 제22권, 제4-A호, 847-857, 2002
  10. Chopra, A.K., Dynamics of structures - theory and applications to earthquake engineering, 2nd ed, Prentice-Hall, New Jersey, 876, 2001
  11. Jansen, L.M. and Dyke, S.J., “Semiactive control strategies for MR dampers: comparative study,” Journal of Engineering Mechanics, Vol. 126, No. 8, 795-803, 2000 https://doi.org/10.1061/(ASCE)0733-9399(2000)126:8(795)
  12. Dyke, S.J., Yi, F. and Carlson, J.D., “Application of magnetorheological dampers to seismically excited structures,” Proc. International Modal Analysis Conference, Kissimmee, Fla., 1999
  13. Yoshida, O. and Dyke, S.J., “Seismic control of a nonlinear benchmark building using smart dampers,” Journal of Engineering Mechanics, ASCE, Vol. 130, No. 4, 386-392, 2004 https://doi.org/10.1061/(ASCE)0733-9399(2004)130:4(386)
  14. Passino KM, Yurkovich S., Fuzzy control, Reading/New York: Addison-29, Wesley / Longman, 475, 1998
  15. 옥승용, “가변오리피스 감쇠기를 사용한 교량의 반능동적 진동 제어에 관한 연구,” 석사학위논문, 서울대학교, 11, 1999
  16. Symans, M.D., and Kelly, S.W., “Fuzzy logic control of bridge structures using intelligent semi-active seismic isolation systems,” Earthquake Engineering and Structural Dynamics, Vol. 28, No. 1, 37-60, 1999 https://doi.org/10.1002/(SICI)1096-9845(199901)28:1<37::AID-EQE803>3.0.CO;2-Z