• Title/Summary/Keyword: frequency-response

Search Result 5,570, Processing Time 0.033 seconds

Correlation of acoustic features and electrophysiological outcomes of stimuli at the level of auditory brainstem (자극음의 음향적 특성과 청각 뇌간에서의 전기생리학적 반응의 상관성)

  • Chun, Hyungi;Han, Woojae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.1
    • /
    • pp.63-73
    • /
    • 2016
  • It is widely acknowledged that the human auditory system is organized tonotopically and people generally listen to sounds as a function of frequency distribution through the auditory system. However, it is still unclear how acoustic features of speech sounds are indicated to the human brain in terms of speech perception. Thus, the purpose of this study is to investigate whether two sounds with similar high-frequency characteristics in the acoustic analysis show similar results at the level of auditory brainstem. Thirty three young adults with normal hearing participated in the study. As stimuli, two Korean monosyllables (i.e., /ja/ and /cha/) and four frequencies of toneburst (i.e., 500, 1000, 2000, and 4000 Hz) were used to elicit the auditory brainstem response (ABR). Measures of monosyllable and toneburst were highly replicable and the wave V of waveform was detectable in all subjects. In the results of Pearson correlation analysis, the /ja/ syllable had a high correlation with 4000 Hz of toneburst which means that its acoustic characteristics (i.e., 3671~5384 Hz) showed the same results in the brainstem. However, the /cha/ syllable had a high correlation with 1000 and 2000 Hz of toneburst although it has acoustical distribution of 3362~5412 Hz. We concluded that there was disagreement between acoustic features and physiology outcomes at the auditory brainstem level. This finding suggests that an acoustical-perceptual mapping study is needed to scrutinize human speech perception.

Channel estimation scheme of terrestrial DTV transmission employing unique-word based SC-FDE (Unique-word 채용한 SC-FDE 기반 지상파 DTV 전송의 채널 추정 기법)

  • Shin, Dong-Chul;Kim, Jae-Kil;Ahn, Jae-Min
    • Journal of Broadcast Engineering
    • /
    • v.16 no.2
    • /
    • pp.207-215
    • /
    • 2011
  • A signal passed through multi-path channel suffers ISI(Inter-Symbol Interference) and severe distortions caused by channel delay spread and noise components at the SC-FDE(Single Carrier with Frequency Domain Equalizer) transmission. Conventional UW(Unique-Word) based SC-FDE iterative channel estimation improves channel estimation performance by smoothing estimated CIR(Channel Impulse Response) of the noise components outside the channel length at time domain and restoring the broken cyclic property through UW reconstruction. In this paper, we propose channel estimation scheme through noise suppression within channel length. To suppress the noise, we estimate noise standard deviation as estimated CIR of the noise components outside the channel length and make criteria of the noise standard deviation gain that doesn't affect the original signal samples. When estimated CIR samples within channel length are less than the criteria value using the noise standard deviation and gain, the noise components are removed. Simulation results show that the proposed channel estimation scheme brings good channel MSE(Mean Square Error) and good BER(Bit Error Rate) performance.

Respiratory Sinus Arrhythmia: Methods of Measurement and Interpretations of Tonic and Dynamic Vagal Cardiac Drive Index in Psychophysiology of Emotions

  • Estate M.Sokhadze;Lee, Jong-Mi;Park, Mi-Kyung;Sohn, Jin-Hun
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.81-87
    • /
    • 2000
  • Beat-to-beat changes in heart period (heart period variability, HPV) are mediated by fluctuations in autonomic activity. Spectral analysis is used to quantify such fluctuations in the range of 0.15-0.40 Hz (high frequency, HF), which are influenced primarily by parasympathetic factors. These fluctuations are often referred to as RSA (respiratory sinus arrhythmia), the physiological phenomenon extracted by spectral analysis and other methods including histograms of heart rate ( HR), deviations of HR etc. Respiratory sinus arrhythmia indexing with peak-to-valley method suggested by Grossman et at., (1981) yields a simple range statistic and is quantified on breath-by-breath basis, thus being quite sensitive and less dependent on recording time as compared to spectral analysis. It is strongly recommended to use at least 1 min epoch to asses HF component of HPV and at least 2 min fer low frequency (LF) of HPV and even 5 min far valid clinical assessment. Peak-to-valley statistic is limited to RSA index only, but has its pragmatic advantages. Most important is possibility of its application far relatively small epoch analysis. We used short periods (20,30, 40 sec only) and off-line analysis of RSA using ECG and respiration curve this method of assessment and proved that this method is more practically effective. The RSA index was not so far dependent on respiration pattern differences and reflected actual vagal control of HR and were accompanied by low HR under some high stress conditions and in an aversive affective visual stimulation experiments. Another factor that might modulate cardiac chronotropic response is the interaction of sympathetic and parasympathetic inputs on sino-atrial (SA) node level, because responses to vagal influences are known to be proportional to ongoing sympathetic activity, that is so called accentuated antagonism. Since sympathetic outflow (increment of influences on SA) under negative emotions or stress was high in almost all physiological responses, vagal effects on HR could be therefore potentiated, leading to masking of output cardiac response seen in HPV, In the case of moderate sympathetic activation, on the other hand, autonomic interactions in cardiac control appear to be minimal. Thus RSA index appears to be an effective alternative method to assess and measure spectral HPV.

  • PDF

Evaluation of Oil Infiltration Behavior in Porous Media Using Dielectric Response (유전율에 의한 지반 매질내 유류침투거동 분석)

  • Kim Man-Il;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.15 no.1
    • /
    • pp.29-39
    • /
    • 2005
  • For detecting a ground contamination survey, soil sampling method have been used a drilling or coring technique in general. However these methods are very difficult to systematically real-time monitoring of variation of contamination degree in field. ]'n this research frequency Domain Reflectometry (FDR) system was suggested and carried out to experimental approaches for determination of oil contamination on surface and underground. Experimental method using FDR method was discussed with feasibility of measurement in the laboratory column test. It is determined to degree of oil contamination due to response of dielectric constant re-lated with volumetric water content(θ/sub w/) and volumetric oil content( θ/sub al/ ) of saturated and unsaturated soil media. And physical properties such as effective porosity and oil residual ratio of saturated soil media were also measured through real-time monitoring works using installed FDR measurement sensors, which are defected characteristics of oil movement in the saturated soil media under the soil column tests. In the results of these experiments, a range of effective porosity was estimated to about 0.35 compared with initial porosity 0.40 of manufactured saturated soil media, which is also calculated to about 87.5% to the ratio of initial porosity to effective porosity. Finally oil residual ratio which is compared with volumetric water content and volumetric oil content was calculated about 62.5%.

Detection of Precise Crop Locations under Vinyl Mulch using Non-integral Moving Average Applied to Thermal Distribution

  • Cho, Yongjin;Yun, Yeji;Lee, Kyou-Seung;Lee, Dong-Hoon
    • Journal of Biosystems Engineering
    • /
    • v.42 no.2
    • /
    • pp.117-125
    • /
    • 2017
  • Purpose: Damage to pulse crops by wild birds is a serious problem. The damage is to such an extent that the rate of damage during the period between seeding and cotyledon stages reaches 54.6% on an average. In this study, a crop-position detection method was developed wherein infrared (IR) sensors were used to determine the cotyledon position under a vinyl mulch. Methods: IR sensors that helped measure the temperature were used to locate the cotyledons below the vinyl mulch. A single IR sensor module was installed at three locations of the crops (peanut, red lettuce, and crown daisy) in the cotyledon stage. The representative thermal response of a $16{\times}4$ pixel area was detected using this sensor in the case where the distance from the target was 25 cm. A spatial image was applied to the two-dimensional temperature distribution using a non-integral moving-average method. The collected data were first processed by taking the moving average via interpolation to determine the frame where the variance was the lowest for a resolution unit of 1.02 cm. Results: The temperature distribution was plotted corresponding to a distance of 10 cm between the crops. A clear leaf pattern of the crop was visually confirmed. However, the temperature distribution after the normalization was unclear. The image conversion and frequency-conversion graphs were obtained based on the moving average by averaging the points corresponding to a frequency of 40 Hz for 8 pixels. The most optimized resolutions at locations 1, 2, and 3 were found on 3.4, 4.1, and 5.6 Pixels, respectively. Conclusions: In this study, to solve the problem of damage caused by birds to crops in the cotyledon stage after seeding, the vinyl mulch is punched after seeding. The crops in the cotyledon stage could be accurately located using the proposed method. By conducting the experiments using the single IR sensor and a sliding mechanical device with the help of a non-integral interpolation method, the crops in the cotyledon stage could be precisely located.

The basic experiments for the fabrication of the SPUDT type Inter using the SFIT type filter (SFIT형태를 이용한 SPUDT형 필터제작에 관한 기초실험)

  • You, Il-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1916-1923
    • /
    • 2007
  • We have studied to obtain the SAW filter for the passband was formed on the Langasite substrate and was evaporated by Aluminum-Copper alloy and thin we performed computer-simulated by simulator. We cm fabricate that the block weighted type IDT as an input transducer of the filter and the withdrawal weighted type IDT as an output transducer of the filter from the results of our computer-simulation. Also, we have performed to obtain the properly design conditions about phase shift of the SAW filter for WCDMA. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness and the width of reflector are $5000\;{\AA}$ and $3.6{\mu}m$ respectively. And we have employed that the distances from the hot electrode to the reflector are $2.0{\mu}m$, $2.4{\mu}m$ and the distance from the hot electrode to the ground is $1.5{\mu}m$ respectively. Frequency response of the fabricated SAW filter has the property that the center frequency is about 190MHz and bandwidth at the 3dB is probably 7,8MHz. And we could obtain that return loss is less then -18dB, ripple characteristics is probably 3dB and triple transit echo is less then -25dB after when we have matched impedance.

Development of Performance Analysis 80 kW High-efficiency Permanent Magnet Generator for Radar System Power Supply (레이더 체계 전원공급용 80 kW급 고효율 영구자석형 발전기 개발 및 성능분석)

  • Ryu, Ji-Ho;Cho, Chong-Hyeon;Chong, Min-Kil;Park, Sung-Jin;Kang, Kwang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.60-71
    • /
    • 2019
  • Electrical power supply is needed to operate the radar system in the field. In addition, it should not cause performance deterioration under the environmental factors due to characteristics of military equipment, and should not cause malfunction due to electromagnetic waves generated in radar, and then should not cause malfunction in radar equipment. Therefore, By applying a permanent magnet to the rotor of the generator, light weighting and high efficiency of generator were achieved. As a result, electrical performance test of the generator, the rated output power was 80.8 kW, the maximum output power was 88.1 kW, and the output power efficiency was 98.1 % under the full load condition. When the load capacity of the generator was changed from no load to full load, the maximum voltage variation was 3.6 % and the frequency variation was 0.3 %. As a result of the transient response test for measuring the output power of the generator according to the load characteristics change, the maximum voltage variation of 7.9 %, frequency variation of 0.5 % were confirmed, and the transient response time was 2.1 seconds. Environmental tests were conducted in accordance with MIL-STD-810G and MIL-STD-461F to evaluate the operability of the generator groups. Normal operation of radar system generator group was confirmed under high temperature and low temperature environment conditions. Electromagnetic tests were conducted to check if electromagnetic wave generated from both radar system and generator group in operation caused any performance deterioration to each other. As a result, it was confirmed that the performance deterioration due to electromagnetic wave inflow, radiation, and conduction did not occur. It is expected that it should be possible to provide high efficiency power supply and stable power supply by applying to various military system as well as radar system.

Seismic Performance Evaluation of Concrete Anchors used in Power Plant Equipment by Shaking Table Tests (진동대 실험을 통한 발전기기용 콘크리트 앵커의 성능평가)

  • Lee, Sang-Moon;Jeon, Bub-Gyu;Jung, Woo-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.21-28
    • /
    • 2021
  • The main purpose of this study is to assess the safety of the fixed anchorages subjected to the seismic motion for an operating facilities in the actual power plant. Thus, the experimental study was conducted to investigate the load response in the event of an actual seismic to the anchorages of a nonstructural components. Since there are economic and spatial constraints to study nonstructural components that actually have various forms, alternative test specimens of steel frames with mass were built and the shaking table test was carried out. In order to evaluate the dynamic characteristics and seismic performance, the natural frequency of the target structure was identified through the shaking table test and then the load response characteristics of the anchorage were evaluated by generating an artificial seismic effect like actual seismic. Finally, the structural stiffness was reinforced by fixing the steel frame to the test specimen using bolts, thereby reducing the load transmitted to the anchorage. It will be carried out on the reliability verification of the experiments and areas that have not been carried out due to the site conditions through the analytical approach in the future.

Analytical Study on Vibrational Properties of High Damping Polymer Concrete (고 감쇠 폴리머 콘크리트의 진동 특성에 관한 해석적 연구)

  • Kim, Jeong-Jin;Kim, Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.119-125
    • /
    • 2020
  • Research on high-attenuation concrete for the vibration reduction performance by mixing epoxy-based synthetic resins and aggregates is actively being conducted. The curing time of high-attenuation concrete is very short because water is not used, and the physical and dynamic properties are very excellent. therefore, it is expected to be widely used in building structures requiring reduction of interior-floor noise and vibration. Furthermore, A way to expand the applicability of the high-damping concrete mixed with polymer in the field of reinforcement material have been variously studied. In order to replace polymer concrete with ordirnary concrete and existing anti-vibration reinforcement material, it is necessary to review overall vibration reduction performance considering physical properties, dynamic properties, productivity and field applicability. In this study, the physical and dynamic properties of polymer concrete by epoxy mixing ratio compared with ordirnary concrete. As a result, the elastic modulus was similar. On the other hand, polymer concrete for the compressive, tensile, and flexural strengths was quite more excellent. In particular, the measured tensile strength of polymer concrete was 4-10 times higher than that of ordirnary concrete. it was a big difference, and the frequency response function and damping ratio was studied through modal test and finite element analysis model. The dynamic stiffness of polymer concrete was 20% greater than that of ordirnary concrete, and the damping ratio of polymer concrete was approximately 3 times more than that of ordirnary concrete.

Vibrational Properties of High Damping Polymer Concrete with Hybrid Damper (복합구조 댐퍼를 적용한 고 감쇠 폴리머 콘크리트의 진동 특성에 관한 연구)

  • Kim, Jeong-Jin;Choi, Kyung-Suk;We, Joon-Woo;Seok, Won-Kyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.135-142
    • /
    • 2020
  • In the case of a concrete structure, vibration problems occur under various conditions because of its low damping performance. To solve this problem, a study on the high damping performance of the polymer concrete with hybrid damper has recently been increased. Since water is not used in polymer concrete, the curing time is short. Also, the physical properties and dynamic properties of polymer concrete are quite excellent. So polymer concrete is widely expected to be used for structural materials. The hybrid damper is the structural system that consists of steel balls and viscous fluid inside the pipe which is embedded in polymer concrete. It can reduce the structural vibrations through the energy dissipation mechanism of viscous fluid and steel balls. In this study, the physical and dynamic properties of polymer concrete with hybrid damper were compared with ordinary concrete. As a result, the elasticity coefficient and the strength of the polymer concrete with hybrid damper were so much excellent. In particular, the tensile strength was 6.5 to 10 times higher than ordinary concrete. The frequency response function and damping ratio were also compared. As a result, the dynamic Stiffness of the polymer concrete was 25% greater than that of ordinary concrete. The damping ratio of the polymer concrete was approximately 3 times higher than that of ordinary concrete. Although the dynamic stiffness of the hybrid damper showed similar tendency, the damping ratio was 3.5 times higher than that of ordinary concrete. Therefore, the polymer concrete with hybrid damper was superior to ordinary concrete.