• 제목/요약/키워드: frequency-phase method

검색결과 1,650건 처리시간 0.034초

A Numerically Controlled Oscillator with a Fine Phase Tuner and a Rounding Processor

  • Lim, In-Gi;Kim, Whan-Woo
    • ETRI Journal
    • /
    • 제26권6호
    • /
    • pp.657-660
    • /
    • 2004
  • We propose a fine phase tuner and a rounding processor for a numerically controlled oscillator (NCO), yielding a reduced phase error in generating a digital sine waveform. By using the fine phase tuner presented in this paper, when the ratio of the desired sine wave frequency to the clock frequency is expressed as a fraction, an accurate adjustment in representing the fractional value can be achieved with simple hardware. In addition, the proposed rounding processor reduces the effects of phase truncation on the output spectrum. Logic simulation results of the NCO using these techniques show that the noise spectrum and mean square error (MSE) for eight output bits of a 3.125 MHz sine waveform are reduced by 8.68 dB and 5.5 dB, respectively, compared to those of the truncation method, and 2.38 dB and 0.83 dB, respectively, compared to those of Paul's scheme.

  • PDF

직렬형 단상 하이브리드 능동 전력필터의 새로운 제어법 (A New Control Method of Series Single-Phase Hybrid Active Power Filter)

  • 김진선;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.149-151
    • /
    • 2005
  • This paper deals with the novel control algorithm of single-phase hybrid active power filter for the compensation of harmonic current components in nonlinear R-L load with passive active power filters. To construct two-axes coordinate, an imaginary second phase was made by giving time delay to line current. In this proposed method, the new signal, which was the delayed through the filtering by the phase-delay property of low-pass filter, is used as the secondary phase. Because two phases have different phase, instantaneous calculation of harmonic current is possible. In this paper, a reference voltage is created by multiplying gain of filter by compensation current using the rotating reference frames that synchronizes with source-frequency, not applying to instantaneous reactive power theory which has been used with the existing fixed reference frames. This paper shows the experimental results, which provide a high accuracy and extremely fast response of single-phase hybrid active Bower filter under the operation with the proposed control method.

  • PDF

저주파 잡음 상향 변화 이득 해석을 이용한 K 밴드 저잡음 국부 발진기의 설계 (Low Noise Local Oscillator Design in K Band using Baseband Noise Upconversion Gain Analysis)

  • 이영택;이문규;임종식;염인복;장동필;남상욱
    • 한국전자파학회논문지
    • /
    • 제12권3호
    • /
    • pp.462-469
    • /
    • 2001
  • 본 논문에서는 저주파 잡음이 상향변환 이득 해석을 이용한 K 밴드 국부발진기를 설계 및 제작하였다. 상향 변환 이득을 해석하고, 그에 따른 위상잡음을 예측하기 위하여 Two Signal Method(TSM)을 확장하였다. 제시된 이론의 유용성을 검증하기 위해 저 상향변환 이득을 갖는 회로의 동작점을 선택하여 free-running 발진기를 설계하였다. 측정결과 발진주파수는 23.42 GHz였고, 위상잡음은 1MHz offset에서 -105.2 dBc/Hz로 우수한 특성을 보였다. 그리고 같은 회로를 부고조파로 주입시켜 부고조파 주입동기 발진기로 동작시켰으며, 이 경우에도 낮은 부고조파 입력 파워에서 이상적인 체배기의 위상잡음 특성을 보였다.

  • PDF

Metaheuristic 알고리즘을 적용한 위상회전 기법에 의한 PAPR 감소에 관한 연구 (A Study on the PAPR Reduction Using Phase Rotation Method Applying Metaheuristic Algorithm)

  • 유선용;박비호;김완태;조성준
    • 대한전자공학회논문지TC
    • /
    • 제46권5호
    • /
    • pp.26-35
    • /
    • 2009
  • OFDM (Orthogonal Frequency Division Multiplexing) 시스템은 주파수 선택적 페이딩 (frequency selective fading)과 협대역 간섭 (narrowband interference)에 강한 전송 방식으로 대용량 데이터 통신에 적합하다. 하지만 독립적으로 변조된 다수의 부반송파들이 동위상으로 중첩되면서 신호의 진폭이 증가하여 PAPR (Peak-to-Average Power Ratio)이 증가하는 문제가 발생한다. PAPR 문제를 해결하기 위해 제안된 위상회전 기법은 OFDM 신호에 위상 가중치를 곱하여 신호의 비선형 왜곡 없이 PAPR을 감소시킬 수 있지만, 위상 가중치를 탐색하는 과정에서 계산의 복잡도가 부블록 수에 따라 지수적으로 증가하는 단점이 있다. 따라서 위상회전 기법의 위상 탐색 과정에 계산의 복잡도를 감소시키면서 효율적으로 위상 가중치를 구할 수 있는 기술의 연구가 필요하다. 본 논문에서는 최적해를 구하기 위하여 사용되는 Metaheuristic 알고리즘을 위상탐색 과정에 적용하기 위한 모델링 과정을 제시하고 PTS 기법에 최적화함으로써 PAPR을 감소시키는 구조를 제안한다. 이 구조는 PTS 기법의 위상 탐색 과정에서 계산 복잡도가 지수적으로 증가하는 문제를 해결하고 PAPR 감소 성능도 보장할 수 있다. 제안하는 알고리즘을 통신 시스템에 적용하였을 때 PAPR 감소 효율을 시뮬레이션을 통해 분석했다.

다기능 레이더용 주파수합성기 개발 (Development of the Frequency Synthesizer for Multi-function Radar)

  • 이희민;최재흥;한일탁
    • 한국정보통신학회논문지
    • /
    • 제22권8호
    • /
    • pp.1099-1106
    • /
    • 2018
  • 본 논문은 장거리 다기능레이더용 주파수합성기 개발에 관한 것으로 다기능레이더 체계의 기능 및 성능을 보장하기 위해 필요한 주파수합성기 성능지표를 도출하고 분석하였다. 다기능레이더는 위상배열 전자 스캔 방식을 적용한 레이더체계이고, 주파수합성기는 STALO를 포함하여 다기능레이더에 필요한 다양한 주파수신호를 합성하는 역할을 수행한다. 다기능레이더 요구사항 분석을 통해 최적의 주파수합성 방식을 선택하고, 회로크기를 포함한 성능 및 기능을 최적화하였다. 도출된 MFR용 주파수합성기 개발규격을 만족하기 위해 DDS-driven Offset-PLL(Phase Locked Loop) 방식을 사용하여 낮은 위상 잡음과 빠른 주파수 고정 시간, 우수한 불요파 특성을 갖는 주파수 합성기를 설계 및 제작하였다. 제작된 다기능 레이더용 주파수합성기는 위상잡음 -131dBc/Hz@100kHz 이하, 주파수 고정시간 $4.1{\mu}s$ 이하의 성능을 측정하였다.

단위 역률을 갖는 3상 BUCK 다이오드 정류기에서의 DC 리플-전압 저감 (DC Ripple-Voltage Suppression in three Phase BUCK DIODE Rectifiers with Unity Power Factor)

  • 이동윤;송중호;최주엽;최익;김광배;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2653-2655
    • /
    • 1999
  • A technique to suppress the low frequency ripple voltage of the DC output voltage in three-phase buck diode rectifiers is presented. A pulse frequency modulation method is employed to regulate the output voltage of the rectifier and guarantee zero-current switching of the switch over the wide operating range. The pulse frequency control method used in this paper shows generally good performance such as low THD of the input line current and unity power factor. In addition, the pulse frequency method can be effectively used to suppress the low frequency voltage ripple appeared in the dc output voltage. The proposed technique illustrates its validity and effectiveness through the respective simulations and experiments.

  • PDF

기본파 성분의 정확한 측정을 위한 해석적 방법 (An Analytic Method for Measuring Accurate Fundamental Frequency Components)

  • 남순열;강상희;박종근
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권4호
    • /
    • pp.175-182
    • /
    • 2002
  • This paper proposes an analytic method for measuring the accurate fundamental frequency component of a fault current signal distorted with a DC-offset, a characteristic frequency component, and harmonics. The proposed algorithm is composed of four stages: sine filer, linear filter, Prony's method, and measurement. The sine filter and the linear filter eliminate harmonics and the fundamental frequency component, respectively. Then Prony's method is used to estimate the parameters of the DC-offset and the characteristic frequency component. Finally, the fundamental frequency component is measured by compensating the sine-filtered signal with the estimated parameters. The performance evaluation of the proposed method is presented for a-phase to around faults on a 345 kV 200 km overhead transmission line. The EMTP is used to generate fault current signals under different fault locations and fault inception angles. It is shown that the analytic method accurately measures the fundamental frequency component regardless of the characteristic frequency component as well as the DC-offset.

Phase Compensation of Fuzzy Control Systems and Realization of Neuro-fuzzy Compenastors

  • Tanaka, Kazuo;Sano, Manabu
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1993년도 Fifth International Fuzzy Systems Association World Congress 93
    • /
    • pp.845-848
    • /
    • 1993
  • This paper proposes a design method of fuzzy phase-lead compensator and its self-learning by neural network. The main feature of the fuzzy phase-lead compensator is to have parameters for effectively compensating phase characteristics of control systems. An important theorem which is related to phase-lead compensation is derived by introducing concept of frequency characteristics. We propose a design procedure of fuzzy phase-lead compensators for linear controlled objects. Furthermore, we realize a neuro-fuzzy compensator for unknown or nonlinear controlled objects by using Widrow-Hoff learning rule.

  • PDF

PLL기법에 기반한 PWM 컨버터 전원 위상각 검출에 관한 연구 (A Study on the phase angle detection of power source for PWM converter based on PLL method)

  • 최철;이상훈;김철우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.284-288
    • /
    • 2005
  • This paper proposes the direct detection method of phase angle for the power source, which is based on the PLL method. The proposed method using a bidirectional photo-coupler is used to directly detect the zero crossing of phase voltage and calculate the angular frequency in the controller based on a M/T algorithm. Through the method, the additional installation space in the traditional method using a potential transformer can be minimized and it can be easy to design. The paper presents straightforward schematic circuits, design and experimental results.

  • PDF

3상 변압기를 이용한 절연형 멀티레벨 인버터 (Isolated Multi-level Inverter Using 3-Phase Transformers)

  • 김태진;박성준;김철우;송성근
    • 전력전자학회논문지
    • /
    • 제12권2호
    • /
    • pp.139-148
    • /
    • 2007
  • 본 논문에서는 3상 저주파 변압기를 이용한 절연형 멀티레벨 인버터를 제안한다. 제안된 인버터는 3상 절연형 변압기를 이용함으로 비절연형 멜티레벨 인버터와 달리 단일 직류 전원을 사용할 수 있는 장점이 있으며, 기존의 단상 변압기를 이용한 3상 멀티레벨 인버터에 비하여 변압기의 수를 줄일 수 있다. 또한 출력 기본주파수와 동일한 스위칭 주파수로 동작하는 스위칭 각 제어 방식을 통하여 출력 전압의 저차 고조파 성분과 스위치 손실을 줄일 수 있었다. Matlab을 이용한 시뮬레이션 및 실험을 통하여 제안된 방식의 타당성을 검증 하였다.